@@ -403,39 +403,21 @@ def refresh() {
if (device.getDataValue("manufacturer") == "SmartThings") { if (device.getDataValue("manufacturer") == "SmartThings") {
log.debug "Refreshing Values for manufacturer: SmartThings " log.debug "Refreshing Values for manufacturer: SmartThings "
refreshCmds = refreshCmds + [ /* These values of Motion Threshold Multiplier(0x01) and Motion Threshold (0x0276)
/* These values of Motion Threshold Multiplier(01) and Motion Threshold (7602) seem to be giving pretty accurate results for the XYZ co-ordinates for this manufacturer.
seem to be giving pretty accurate results for the XYZ co-ordinates for this manufacturer. Separating these out in a separate if-else because I do not want to touch Centralite part
Separating these out in a separate if-else because I do not want to touch Centralite part as of now.
as of now. */
*/ refreshCmds += zigbee.writeAttribute(0xFC02, 0x0000, 0x20, 0x01, [mfgCode: manufacturerCode])
refreshCmds += zigbee.writeAttribute(0xFC02, 0x0002, 0x21, 0x0276, [mfgCode: manufacturerCode])
"zcl mfg-code ${manufacturerCode}", "delay 200",
"zcl global write 0xFC02 0 0x20 {01}", "delay 200",
"send 0x${device.deviceNetworkId} 1 1", "delay 400",
"zcl mfg-code ${manufacturerCode}", "delay 200",
"zcl global write 0xFC02 2 0x21 {7602}", "delay 200",
"send 0x${device.deviceNetworkId} 1 1", "delay 400",
]
} else { } else {
refreshCmds = refreshCmds + [ refreshCmds += zigbee.writeAttribute(0xFC02, 0x0000, 0x20, 0x02, [mfgCode: manufacturerCode])
/* sensitivity - default value (8) */
"zcl mfg-code ${manufacturerCode}", "delay 200",
"zcl global write 0xFC02 0 0x20 {02}", "delay 200",
"send 0x${device.deviceNetworkId} 1 1", "delay 400",
]
} }
//Common refresh commands //Common refresh commands
refreshCmds = refreshCmds + [ refreshCmds += zigbee.readAttribute(0x0402, 0x0000) +
"st rattr 0x${device.deviceNetworkId} 1 0x402 0", "delay 200", zigbee.readAttribute(0x0001, 0x0020) +
"st rattr 0x${device.deviceNetworkId} 1 1 0x20", "delay 200", zigbee.readAttribute(0xFC02, 0x0010, [mfgCode: manufacturerCode])
"zcl mfg-code ${manufacturerCode}", "delay 200",
"zcl global read 0xFC02 0x0010",
"send 0x${device.deviceNetworkId} 1 1","delay 400"
]
return refreshCmds + enrollResponse() return refreshCmds + enrollResponse()
} }
@@ -443,38 +425,15 @@ def refresh() {
def configure() { def configure() {
sendEvent(name: "checkInterval", value: 7200, displayed: false) sendEvent(name: "checkInterval", value: 7200, displayed: false)
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
log.debug "Configuring Reporting" log.debug "Configuring Reporting"
def configCmds = [ def configCmds = enrollResponse() +
"zcl global write 0x500 0x10 0xf0 {${zigbeeEui}}", "delay 200", zigbee.batteryConfig() +
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500", zigbee.temperatureConfig() +
zigbee.configureReporting(0xFC02, 0x0010, 0x18, 10, 3600, 0x01, [mfgCode: manufacturerCode]) +
"zdo bind 0x${device.deviceNetworkId} ${endpointId} 1 1 {${device.zigbeeId}} {}", "delay 200", zigbee.configureReporting(0xFC02, 0x0012, 0x29, 1, 3600, 0x0001, [mfgCode: manufacturerCode]) +
"zcl global send-me-a-report 1 0x20 0x20 30 21600 {01}", "delay 200", //checkin time 6 hrs zigbee.configureReporting(0xFC02, 0x0013, 0x29, 1, 3600, 0x0001, [mfgCode: manufacturerCode]) +
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500", zigbee.configureReporting(0xFC02, 0x0014, 0x29, 1, 3600, 0x0001, [mfgCode: manufacturerCode])
"zdo bind 0x${device.deviceNetworkId} ${endpointId} 1 0x402 {${device.zigbeeId}} {}", "delay 200",
"zcl global send-me-a-report 0x402 0 0x29 30 3600 {6400}", "delay 200",
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
"zdo bind 0x${device.deviceNetworkId} ${endpointId} 1 0xFC02 {${device.zigbeeId}} {}", "delay 200",
"zcl mfg-code ${manufacturerCode}", "delay 200",
"zcl global send-me-a-report 0xFC02 0x0010 0x18 10 3600 {01}", "delay 200",
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
"zcl mfg-code ${manufacturerCode}", "delay 200",
"zcl global send-me-a-report 0xFC02 0x0012 0x29 1 3600 {0100}", "delay 200",
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
"zcl mfg-code ${manufacturerCode}", "delay 200",
"zcl global send-me-a-report 0xFC02 0x0013 0x29 1 3600 {0100}", "delay 200",
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
"zcl mfg-code ${manufacturerCode}", "delay 200",
"zcl global send-me-a-report 0xFC02 0x0014 0x29 1 3600 {0100}", "delay 200",
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500"
]