From 03e0b95d3f05f0399d0349b72f3cdea36a8ff9f5 Mon Sep 17 00:00:00 2001 From: Rich Bira Date: Mon, 24 Jul 2017 09:42:55 -0700 Subject: [PATCH] MSA-2127: Fibaro Door/ Window 2 is a new contact sensor that was released in Europe in June 2017 and will be released in the USA on August 1st. D/W 2 has integrated temperature sensor and we revised how parameters are adjusted. --- .../fibaro-door-window-sensor-2.groovy | 462 ++++++++++++++++++ 1 file changed, 462 insertions(+) create mode 100644 devicetypes/fibargroup/fibaro-door-window-sensor-2.src/fibaro-door-window-sensor-2.groovy diff --git a/devicetypes/fibargroup/fibaro-door-window-sensor-2.src/fibaro-door-window-sensor-2.groovy b/devicetypes/fibargroup/fibaro-door-window-sensor-2.src/fibaro-door-window-sensor-2.groovy new file mode 100644 index 0000000..d5eab91 --- /dev/null +++ b/devicetypes/fibargroup/fibaro-door-window-sensor-2.src/fibaro-door-window-sensor-2.groovy @@ -0,0 +1,462 @@ +/** + * Fibaro Door/Window Sensor 2 + * + * Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except + * in compliance with the License. You may obtain a copy of the License at: + * + * http://www.apache.org/licenses/LICENSE-2.0 + * + * Unless required by applicable law or agreed to in writing, software distributed under the License is distributed + * on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License + * for the specific language governing permissions and limitations under the License. + * + */ +metadata { + definition (name: "Fibaro Door/Window Sensor 2", namespace: "Fibargroup", author: "Fibar Group S.A.") { + capability "Contact Sensor" + capability "Tamper Alert" + capability "Temperature Measurement" + capability "Configuration" + capability "Battery" + capability "Sensor" + capability "Health Check" + + attribute "temperatureAlarm", "string" + + fingerprint mfr: "010F", prod: "0702" + fingerprint deviceId: "0x0701", inClusters:"0x5E,0x59,0x22,0x80,0x56,0x7A,0x73,0x98,0x31,0x85,0x70,0x5A,0x72,0x8E,0x71,0x86,0x84" + fingerprint deviceId: "0x0701", inClusters:"0x5E,0x59,0x22,0x80,0x56,0x7A,0x73,0x31,0x85,0x70,0x5A,0x72,0x8E,0x71,0x86,0x84" + } + + tiles (scale: 2) { + multiAttributeTile(name:"FGDW", type:"lighting", width:6, height:4) { + tileAttribute("device.contact", key:"PRIMARY_CONTROL") { + attributeState("open", label:"open", icon:"st.contact.contact.open", backgroundColor:"#e86d13") + attributeState("closed", label:"closed", icon:"st.contact.contact.closed", backgroundColor:"#00a0dc") + } + tileAttribute("device.multiStatus", key:"SECONDARY_CONTROL") { + attributeState("multiStatus", label:'${currentValue}') + } + } + + valueTile("tamper", "device.tamper", inactiveLabel: false, width: 2, height: 2, decoration: "flat") { + state "tamper", label:'Tamper:\n ${currentValue}' + } + + valueTile("temperature", "device.temperature", inactiveLabel: false, width: 2, height: 2) { + state "temperature", label:'${currentValue}°', + backgroundColors:[ + [value: 31, color: "#153591"], + [value: 44, color: "#1e9cbb"], + [value: 59, color: "#90d2a7"], + [value: 74, color: "#44b621"], + [value: 84, color: "#f1d801"], + [value: 95, color: "#d04e00"], + [value: 96, color: "#bc2323"] + ] + } + + valueTile("battery", "device.battery", inactiveLabel: false, width: 2, height: 2, decoration: "flat") { + state "battery", label:'${currentValue}%\n battery', unit:"%" + } + + standardTile("temperatureAlarm", "device.temperatureAlarm", inactiveLabel: false, width: 2, height: 2, decoration: "flat") { + state "default", label: "No temp. alarm", backgroundColor:"#ffffff" + state "clear", label:'', backgroundColor:"#ffffff", icon: "st.alarm.temperature.normal" + state "underheat", label:'underheat', backgroundColor:"#1e9cbb", icon: "st.alarm.temperature.freeze" + state "overheat", label:'overheat', backgroundColor:"#d04e00", icon: "st.alarm.temperature.overheat" + } + + main "FGDW" + details(["FGDW","tamper","temperature","battery","temperatureAlarm"]) + } + + preferences { + + input ( + title: "Fibaro Door/Window Sensor 2", + description: "Tap to view the manual.", + image: "http://manuals.fibaro.com/wp-content/uploads/2017/05/dws2.jpg", + url: "http://manuals.fibaro.com/content/manuals/en/FGDW-002/FGDW-002-EN-T-v1.0.pdf", + type: "href", + element: "href" + ) + + input ( + title: "Wake up interval", + description: "How often should your device automatically sync with the HUB. The lower the value, the shorter the battery life.\n0 or 1-18 (in hours)", + type: "paragraph", + element: "paragraph" + ) + + input ( + name: "wakeUpInterval", + title: null, + type: "number", + range: "0..18", + defaultValue: 6, + required: false + ) + + parameterMap().findAll{(it.num as Integer) != 54}.each { + input ( + title: "${it.num}. ${it.title}", + description: it.descr, + type: "paragraph", + element: "paragraph" + ) + + input ( + name: it.key, + title: null, + description: "Default: $it.def" , + type: it.type, + options: it.options, + range: (it.min != null && it.max != null) ? "${it.min}..${it.max}" : null, + defaultValue: it.def, + required: false + ) + } + + input ( name: "logging", title: "Logging", type: "boolean", required: false ) + } +} + +def updated() { + if ( state.lastUpdated && (now() - state.lastUpdated) < 500 ) return + logging("${device.displayName} - Executing updated()","info") + + if ( settings.temperatureHigh as Integer == 0 && settings.temperatureLow as Integer == 0 ) { + sendEvent(name: "temperatureAlarm", value: null, displayed: false) + } else if ( settings.temperatureHigh != null || settings.temperatureHigh != null ) { + sendEvent(name: "temperatureAlarm", value: "clear", displayed: false) + } + + syncStart() + state.lastUpdated = now() +} + +def configure() { + def cmds = [] + cmds << zwave.batteryV1.batteryGet() + cmds << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 1) + encapSequence(cmds,1000) +} + +private syncStart() { + boolean syncNeeded = false + Integer settingValue = null + parameterMap().each { + if(settings."$it.key" != null || it.num == 54) { + if (state."$it.key" == null) { state."$it.key" = [value: null, state: "synced"] } + if ( (it.num as Integer) == 54 ) { + settingValue = (((settings."temperatureHigh" as Integer) == 0) ? 0 : 1) + (((settings."temperatureLow" as Integer) == 0) ? 0 : 2) + } else if ( (it.num as Integer) in [55,56] ) { + settingValue = (((settings."$it.key" as Integer) == 0) ? state."$it.key".value : settings."$it.key") as Integer + } else { + settingValue = settings."$it.key" as Integer + } + if (state."$it.key".value != settingValue || state."$it.key".state != "synced" ) { + state."$it.key".value = settingValue + state."$it.key".state = "notSynced" + syncNeeded = true + } + } + } + + if(settings.wakeUpInterval != null) { + if (state.wakeUpInterval == null) { state.wakeUpInterval = [value: null, state: "synced"] } + if (state.wakeUpInterval.value != ((settings.wakeUpInterval as Integer) * 3600)) { + sendEvent(name: "checkInterval", value: (settings.wakeUpInterval as Integer) * 3600 * 4 + 120, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID]) + state.wakeUpInterval.value = ((settings.wakeUpInterval as Integer) * 3600) + state.wakeUpInterval.state = "notSynced" + syncNeeded = true + } + } else { + sendEvent(name: "checkInterval", value: 21600 * 4 + 120, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID]) + } + + if ( syncNeeded ) { + logging("${device.displayName} - sync needed.", "info") + multiStatusEvent("Sync pending. Please wake up the device by pressing the tamper button.", true) + } +} + +private syncNext() { + logging("${device.displayName} - Executing syncNext()","info") + def cmds = [] + for ( param in parameterMap() ) { + if ( state."$param.key"?.value != null && state."$param.key"?.state in ["notSynced","inProgress"] ) { + multiStatusEvent("Sync in progress. (param: ${param.num})", true) + state."$param.key"?.state = "inProgress" + cmds << response(encap(zwave.configurationV2.configurationSet(configurationValue: intToParam(state."$param.key".value, param.size), parameterNumber: param.num, size: param.size))) + cmds << response(encap(zwave.configurationV2.configurationGet(parameterNumber: param.num))) + break + } + } + if (cmds) { + runIn(10, "syncCheck") + sendHubCommand(cmds,1000) + } else { + runIn(1, "syncCheck") + } +} + +private syncCheck() { + logging("${device.displayName} - Executing syncCheck()","info") + def failed = [] + def incorrect = [] + def notSynced = [] + parameterMap().each { + if (state."$it.key"?.state == "incorrect" ) { + incorrect << it + } else if ( state."$it.key"?.state == "failed" ) { + failed << it + } else if ( state."$it.key"?.state in ["inProgress","notSynced"] ) { + notSynced << it + } + } + + if (failed) { + multiStatusEvent("Sync failed! Verify parameter: ${failed[0].num}", true, true) + } else if (incorrect) { + multiStatusEvent("Sync mismatch! Verify parameter: ${incorrect[0].num}", true, true) + } else if (notSynced) { + multiStatusEvent("Sync incomplete! Wake up the device again by pressing the tamper button.", true, true) + } else { + sendHubCommand(response(encap(zwave.wakeUpV1.wakeUpNoMoreInformation()))) + if (device.currentValue("multiStatus")?.contains("Sync")) { multiStatusEvent("Sync OK.", true, true) } + } +} + +private multiStatusEvent(String statusValue, boolean force = false, boolean display = false) { + if (!device.currentValue("multiStatus")?.contains("Sync") || device.currentValue("multiStatus") == "Sync OK." || force) { + sendEvent(name: "multiStatus", value: statusValue, descriptionText: statusValue, displayed: display) + } +} + +def zwaveEvent(physicalgraph.zwave.commands.wakeupv2.WakeUpNotification cmd) { + logging("${device.displayName} woke up", "info") + def cmds = [] + sendEvent(descriptionText: "$device.displayName woke up", isStateChange: true) + if ( state.wakeUpInterval?.state == "notSynced" && state.wakeUpInterval?.value != null ) { + cmds << zwave.wakeUpV2.wakeUpIntervalSet(seconds: state.wakeUpInterval.value as Integer, nodeid: zwaveHubNodeId) + state.wakeUpInterval.state = "synced" + } + cmds << zwave.batteryV1.batteryGet() + cmds << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 1) + runIn(1,"syncNext") + [response(encapSequence(cmds,1000))] +} + +def zwaveEvent(physicalgraph.zwave.commands.configurationv2.ConfigurationReport cmd) { + def paramKey = parameterMap().find( {it.num == cmd.parameterNumber } ).key + logging("${device.displayName} - Parameter ${paramKey} value is ${cmd.scaledConfigurationValue} expected " + state."$paramKey".value, "info") + state."$paramKey".state = (state."$paramKey".value == cmd.scaledConfigurationValue) ? "synced" : "incorrect" + syncNext() +} + +def zwaveEvent(physicalgraph.zwave.commands.applicationstatusv1.ApplicationRejectedRequest cmd) { + logging("${device.displayName} - rejected request!","warn") + for ( param in parameterMap() ) { + if ( state."$param.key"?.state == "inProgress" ) { + state."$param.key"?.state = "failed" + break + } + } +} + +def zwaveEvent(physicalgraph.zwave.commands.alarmv2.AlarmReport cmd) { + logging("${device.displayName} - AlarmReport received, zwaveAlarmType: ${cmd.zwaveAlarmType}, zwaveAlarmEvent: ${cmd.zwaveAlarmEvent}", "info") + def lastTime = new Date().format("yyyy MMM dd EEE h:mm:ss a", location.timeZone) + switch (cmd.zwaveAlarmType) { + case 6: + sendEvent(name: "contact", value: (cmd.zwaveAlarmEvent == 22)? "open":"closed"); + if (cmd.zwaveAlarmEvent == 22) { multiStatusEvent("Contact Open - $lastTime") } + break; + case 7: + sendEvent(name: "tamper", value: (cmd.zwaveAlarmEvent == 3)? "detected":"clear"); + if (cmd.zwaveAlarmEvent == 3) { multiStatusEvent("Tamper - $lastTime") } + break; + case 4: + if (device.currentValue("temperatureAlarm")?.value != null) { + switch (cmd.zwaveAlarmEvent) { + case 0: sendEvent(name: "temperatureAlarm", value: "clear"); break; + case 2: sendEvent(name: "temperatureAlarm", value: "overheat"); break; + case 6: sendEvent(name: "temperatureAlarm", value: "underheat"); break; + }; + }; + break; + default: logging("${device.displayName} - Unknown zwaveAlarmType: ${cmd.zwaveAlarmType}","warn"); + } +} + +def zwaveEvent(physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd) { + logging("${device.displayName} - SensorMultilevelReport received, sensorType: ${cmd.sensorType}, scaledSensorValue: ${cmd.scaledSensorValue}", "info") + switch (cmd.sensorType) { + case 1: + def cmdScale = cmd.scale == 1 ? "F" : "C" + sendEvent(name: "temperature", unit: getTemperatureScale(), value: convertTemperatureIfNeeded(cmd.scaledSensorValue, cmdScale, cmd.precision), displayed: true) + break + default: + logging("${device.displayName} - Unknown sensorType: ${cmd.sensorType}","warn") + break + } +} + +def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) { + logging("${device.displayName} - BatteryReport received, value: ${cmd.batteryLevel}", "info") + sendEvent(name: "battery", value: cmd.batteryLevel.toString(), unit: "%", displayed: true) +} + +def parse(String description) { + def result = [] + logging("${device.displayName} - Parsing: ${description}") + if (description.startsWith("Err 106")) { + result = createEvent( + descriptionText: "Failed to complete the network security key exchange. If you are unable to receive data from it, you must remove it from your network and add it again.", + eventType: "ALERT", + name: "secureInclusion", + value: "failed", + displayed: true, + ) + } else if (description == "updated") { + return null + } else { + def cmd = zwave.parse(description, cmdVersions()) + if (cmd) { + logging("${device.displayName} - Parsed: ${cmd}") + zwaveEvent(cmd) + } + } +} + +def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) { + def encapsulatedCommand = cmd.encapsulatedCommand(cmdVersions()) + if (encapsulatedCommand) { + logging("${device.displayName} - Parsed SecurityMessageEncapsulation into: ${encapsulatedCommand}") + zwaveEvent(encapsulatedCommand) + } else { + log.warn "Unable to extract secure cmd from $cmd" + } +} + +def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) { + def version = cmdVersions()[cmd.commandClass as Integer] + def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass) + def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data) + if (encapsulatedCommand) { + logging("${device.displayName} - Parsed Crc16Encap into: ${encapsulatedCommand}") + zwaveEvent(encapsulatedCommand) + } else { + log.warn "Could not extract crc16 command from $cmd" + } +} + +private logging(text, type = "debug") { + if (settings.logging == "true") { + log."$type" text + } +} + +private secEncap(physicalgraph.zwave.Command cmd) { + logging("${device.displayName} - encapsulating command using Secure Encapsulation, command: $cmd","info") + zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format() +} + +private crcEncap(physicalgraph.zwave.Command cmd) { + logging("${device.displayName} - encapsulating command using CRC16 Encapsulation, command: $cmd","info") + zwave.crc16EncapV1.crc16Encap().encapsulate(cmd).format() +} + +private encap(physicalgraph.zwave.Command cmd) { + if (zwaveInfo.zw.contains("s")) { + secEncap(cmd) + } else if (zwaveInfo.cc.contains("56")){ + crcEncap(cmd) + } else { + logging("${device.displayName} - no encapsulation supported for command: $cmd","info") + cmd.format() + } +} + +private encapSequence(cmds, Integer delay=250) { + delayBetween(cmds.collect{ encap(it) }, delay) +} + +private List intToParam(Long value, Integer size = 1) { + def result = [] + size.times { + result = result.plus(0, (value & 0xFF) as Short) + value = (value >> 8) + } + return result +} + +private Map cmdVersions() { + [0x5E: 2, 0x59: 1, 0x22: 1, 0x80: 1, 0x56: 1, 0x7A: 3, 0x73: 1, 0x98: 1, 0x31: 5, 0x85: 2, 0x70: 2, 0x5A: 1, 0x72: 2, 0x8E: 2, 0x71: 2, 0x86: 1, 0x84: 2] +} + +private parameterMap() {[ + [key: "doorState", num: 1, size: 1, type: "enum", options: [0: "Closed when magnet near", 1: "Opened when magnet near"], def: "0", title: "Door/window state", + descr: "Defines the state of door/window depending on the magnet position."], + [key: "ledIndications", num: 2, size: 1, type: "enum", options: [ + 1: "Indication of opening/closing", + 2: "Indication of wake up", + 4: "Indication of device tampering", + 6: "Indication of wake up & tampering", + ], + def: "6", title: "Visual LED indications", + descr: "Defines events indicated by the visual LED indicator. Disabling events might extend battery life."], + [key: "tamperDelay", num: 30, size: 2, type: "number", def: 5, min: 0, max: 32400, title: "Tamper - alarm cancellation delay", + descr: "Time period after which a tamper alarm will be cancelled.\n0-32400 - time in seconds"], + [key: "tamperCancelation", num: 31, size: 1, type: "enum", options: [0: "Do not send tamper cancellation report", 1: "Send tamper cancellation report"], def: "1", title: "Tamper – reporting alarm cancellation", + descr: "Reporting cancellation of tamper alarm to the controller and 3rd association group."], + [key: "temperatureMeasurement", num: 50, size: 2, type: "number", def: 300, min: 0, max: 32400, title: "Interval of temperature measurements", + descr: "This parameter defines how often the temperature will be measured (specific time).\n0 - temperature measurements disabled\n5-32400 - time in seconds"], + [key: "temperatureThreshold", num: 51, size: 2, type: "enum", options: [ + 0: "disabled", + 3: "0.5°F/0.3°C", + 6: "1°F/0.6°C", + 11: "2°F/1.1°C", + 17: "3°F/1.7°C", + 22: "4°F/2.2°C", + 28: "5°F/2.8°C"], + def: 11, title: "Temperature reports threshold", + descr: "Change of temperature resulting in temperature report being sent to the HUB."], + [key: "temperatureAlarm", num: 54, size: 1, type: "enum", options: [ + 0: "Temperature alarms disabled", + 1: "High temperature alarm", + 2: "Low temperature alarm", + 3: "High and low temperature alarms"], + def: "0", title: "Temperature alarm reports", + descr: "Temperature alarms reported to the Z-Wave controller. Thresholds are set in parameters 55 and 56"], + [key: "temperatureHigh", num: 55, size: 2, type: "enum", options: [ + 0: "disabled", + 200: "68°F/20°C", + 250: "77°F/25°C", + 300: "86°F/30°C", + 350: "95°F/35°C", + 400: "104°F/40°C", + 450: "113°F/45°C", + 500: "122°F/50°C", + 550: "131°F/55°C", + 600: "140°F/60°C"], + def: 350, title: "High temperature alarm threshold", + descr: "If temperature is higher than set value, overheat high temperature alarm will be triggered."], + [key: "temperatureLow", num: 56, size: 2, type: "enum", options: [ + 0: "disabled", + 6: "33°F/0.6°C", + 10: "34°F/1°C", + 22: "36°F/2.2°C", + 33: "38°F/3.3°C", + 44: "40°F/4.4°C", + 50: "41°F/5°C", + 100: "50°F/10°C", + 150: "59°F/15°C", + 200: "68°F/20°C", + 250: "77°F/25°C"], + def: 100, title: "Low temperature alarm threshold", + descr: "If temperature is lower than set value, low temperature alarm will be triggered."] + ] +} \ No newline at end of file