mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-08 21:02:56 +00:00
Merge pull request #1769 from parijatdas/fortrezz_water_valve
[CHF-539] Health Check FortrezZ Water Valve
This commit is contained in:
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
39
devicetypes/smartthings/fortrezz-water-valve.src/README.md
Normal file
39
devicetypes/smartthings/fortrezz-water-valve.src/README.md
Normal file
@@ -0,0 +1,39 @@
|
||||
# FortrezZ Water Valve
|
||||
|
||||
Cloud Execution
|
||||
|
||||
Works with:
|
||||
|
||||
* [FortrezZ Water Valve](https://www.smartthings.com/works-with-smartthings/other/fortrezz-water-valve)
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
* [Troubleshooting](#troubleshooting)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
* **Valve** - allows for the control of a valve device
|
||||
* **Refresh** - _refresh()_ command for status updates
|
||||
* **Sensor** - detects sensor events
|
||||
|
||||
## Device Health
|
||||
|
||||
FortrezZ Water Valve is polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
* __32min__ checkInterval
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [FortrezZ Water Valve Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202088434-FortrezZ-Water-Valve-Shutoff)
|
||||
@@ -14,11 +14,13 @@
|
||||
metadata {
|
||||
definition (name: "Fortrezz Water Valve", namespace: "smartthings", author: "SmartThings") {
|
||||
capability "Actuator"
|
||||
capability "Health Check"
|
||||
capability "Valve"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
|
||||
fingerprint deviceId: "0x1000", inClusters: "0x25,0x72,0x86,0x71,0x22,0x70"
|
||||
fingerprint mfr:"0084", prod:"0213", model:"0215", deviceJoinName: "FortrezZ Water Valve"
|
||||
}
|
||||
|
||||
// simulator metadata
|
||||
@@ -48,6 +50,11 @@ metadata {
|
||||
}
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
log.trace description
|
||||
def result = null
|
||||
@@ -76,6 +83,13 @@ def close() {
|
||||
zwave.switchBinaryV1.switchBinarySet(switchValue: 0xFF).format()
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
zwave.switchBinaryV1.switchBinaryGet().format()
|
||||
}
|
||||
|
||||
Reference in New Issue