Pass unhandled messages up to the cloud
Currently these DTHs return null when they parse a message that they don't have specific handling for. This ends up sending the message up to the cloud as an event, which prevented us from potentially parsing that message in the cloud. By instead returning an empty map we can instead send the message up to the cloud to be parsed there. This allows us to add handling in the cloud for new message without requiring and AppEngine deploy for them to work. This resolves: https://smartthings.atlassian.net/browse/DPROT-200
This commit is contained in:
@@ -79,6 +79,7 @@ def parse(String description) {
|
||||
log.debug "description is $description"
|
||||
|
||||
def finalResult = zigbee.getKnownDescription(description)
|
||||
def event = [:]
|
||||
|
||||
//TODO: Remove this after getKnownDescription can parse it automatically
|
||||
if (!finalResult && description!="updated")
|
||||
@@ -88,10 +89,11 @@ def parse(String description) {
|
||||
log.info "final result = $finalResult"
|
||||
if (finalResult.type == "update") {
|
||||
log.info "$device updates: ${finalResult.value}"
|
||||
event = null
|
||||
}
|
||||
else if (finalResult.type == "power") {
|
||||
def powerValue = (finalResult.value as Integer)/10
|
||||
sendEvent(name: "power", value: powerValue, descriptionText: '{{ device.displayName }} power is {{ value }} Watts', translatable: true )
|
||||
event = createEvent(name: "power", value: powerValue, descriptionText: '{{ device.displayName }} power is {{ value }} Watts', translatable: true)
|
||||
/*
|
||||
Dividing by 10 as the Divisor is 10000 and unit is kW for the device. AttrId: 0302 and 0300. Simplifying to 10
|
||||
power level is an integer. The exact power level with correct units needs to be handled in the device type
|
||||
@@ -100,7 +102,7 @@ def parse(String description) {
|
||||
}
|
||||
else {
|
||||
def descriptionText = finalResult.value == "on" ? '{{ device.displayName }} is On' : '{{ device.displayName }} is Off'
|
||||
sendEvent(name: finalResult.type, value: finalResult.value, descriptionText: descriptionText, translatable: true)
|
||||
event = createEvent(name: finalResult.type, value: finalResult.value, descriptionText: descriptionText, translatable: true)
|
||||
}
|
||||
}
|
||||
else {
|
||||
@@ -109,10 +111,11 @@ def parse(String description) {
|
||||
if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07){
|
||||
if (cluster.data[0] == 0x00) {
|
||||
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
|
||||
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
event = createEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
else {
|
||||
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
|
||||
event = null
|
||||
}
|
||||
}
|
||||
else {
|
||||
@@ -120,6 +123,7 @@ def parse(String description) {
|
||||
log.debug "${cluster}"
|
||||
}
|
||||
}
|
||||
return event
|
||||
}
|
||||
|
||||
def off() {
|
||||
|
||||
Reference in New Issue