Merge pull request #1706 from SmartThingsCommunity/staging

Rolling up staging to production for deploy
This commit is contained in:
Vinay Rao
2017-02-22 13:44:57 -08:00
committed by GitHub
18 changed files with 80 additions and 44 deletions

View File

@@ -7,6 +7,7 @@
metadata { metadata {
// Automatically generated. Make future change here. // Automatically generated. Make future change here.
definition (name: "Hue Bridge", namespace: "smartthings", author: "SmartThings") { definition (name: "Hue Bridge", namespace: "smartthings", author: "SmartThings") {
capability "Bridge"
capability "Health Check" capability "Health Check"
attribute "networkAddress", "string" attribute "networkAddress", "string"

View File

@@ -14,6 +14,7 @@ metadata {
capability "Refresh" capability "Refresh"
capability "Sensor" capability "Sensor"
capability "Health Check" capability "Health Check"
capability "Light"
} }
simulator { simulator {

View File

@@ -13,6 +13,7 @@ metadata {
capability "Refresh" capability "Refresh"
capability "Sensor" capability "Sensor"
capability "Health Check" capability "Health Check"
capability "Light"
} }
simulator { simulator {

View File

@@ -36,6 +36,7 @@ metadata {
capability "Switch" capability "Switch"
capability "Refresh" capability "Refresh"
capability "Contact Sensor" capability "Contact Sensor"
capability "Light"
attribute "powered", "string" attribute "powered", "string"

View File

@@ -24,6 +24,7 @@ metadata {
capability "Refresh" capability "Refresh"
capability "Actuator" capability "Actuator"
capability "Sensor" capability "Sensor"
capability "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "4257050-ZHAC" fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "4257050-ZHAC"
@@ -79,7 +80,8 @@ def parse(String description) {
*/ */
event.value = event.value / 10 event.value = event.value / 10
} }
return event
return event ? createEvent(event) : event
} }
def setLevel(value) { def setLevel(value) {

View File

@@ -4,6 +4,7 @@ metadata {
capability "Actuator" capability "Actuator"
capability "Switch" capability "Switch"
capability "Sensor" capability "Sensor"
capability "Outlet"
fingerprint profileId: "0104", inClusters: "0006, 0004, 0003, 0000, 0005", outClusters: "0019", manufacturer: "Compacta International, Ltd", model: "ZBMPlug15", deviceJoinName: "SmartPower Outlet V1" fingerprint profileId: "0104", inClusters: "0006, 0004, 0003, 0000, 0005", outClusters: "0019", manufacturer: "Compacta International, Ltd", model: "ZBMPlug15", deviceJoinName: "SmartPower Outlet V1"
} }

View File

@@ -83,9 +83,8 @@ def parse(String description) {
if (event) { if (event) {
if (event.name == "power") { if (event.name == "power") {
event.value = event.value / 10 def value = (event.value as Integer) / 10
event.descriptionText = '{{ device.displayName }} power is {{ value }} Watts' event = createEvent(name: event.name, value: value, descriptionText: '{{ device.displayName }} power is {{ value }} Watts', translatable: true)
event.translatable = true
} else if (event.name == "switch") { } else if (event.name == "switch") {
def descriptionText = event.value == "on" ? '{{ device.displayName }} is On' : '{{ device.displayName }} is Off' def descriptionText = event.value == "on" ? '{{ device.displayName }} is On' : '{{ device.displayName }} is Off'
event = createEvent(name: event.name, value: event.value, descriptionText: descriptionText, translatable: true) event = createEvent(name: event.name, value: event.value, descriptionText: descriptionText, translatable: true)
@@ -106,7 +105,7 @@ def parse(String description) {
log.debug "${cluster}" log.debug "${cluster}"
} }
} }
return event return event ? createEvent(event) : event
} }
def off() { def off() {

View File

@@ -23,6 +23,7 @@ Works with:
* **Switch** - can detect state (possible values: on/off) * **Switch** - can detect state (possible values: on/off)
* **Switch Level** - represents current light level, usually 0-100 in percent * **Switch Level** - represents current light level, usually 0-100 in percent
* **Health Check** - indicates ability to get device health notifications * **Health Check** - indicates ability to get device health notifications
* **Light** - indicates that the device belongs to Light category.
## Device Health ## Device Health

View File

@@ -22,6 +22,7 @@ metadata {
capability "Switch" capability "Switch"
capability "Switch Level" capability "Switch Level"
capability "Health Check" capability "Health Check"
capability "Light"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B04" fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B04"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702" fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702"

View File

@@ -21,6 +21,7 @@ metadata {
capability "Sensor" capability "Sensor"
capability "Switch" capability "Switch"
capability "Health Check" capability "Health Check"
capability "Light"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0B04" fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0B04"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0702" fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0702"

View File

@@ -6,6 +6,12 @@ Works with:
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW)](https://www.smartthings.com/works-with-smartthings/outlets/leviton-plug-in-lamp-dimmer-module) * [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW)](https://www.smartthings.com/works-with-smartthings/outlets/leviton-plug-in-lamp-dimmer-module)
* [Leviton Universal Dimmer (DZMX1-LZ)](https://www.smartthings.com/works-with-smartthings/switches-and-dimmers/leviton-universal-dimmer) * [Leviton Universal Dimmer (DZMX1-LZ)](https://www.smartthings.com/works-with-smartthings/switches-and-dimmers/leviton-universal-dimmer)
* [Leviton 1000W Incandescent Dimmer](https://www.smartthings.com/works-with-smartthings/leviton/leviton-1000w-incandescent-dimmer)
* [Leviton 600W Incandescent Dimmer](https://www.smartthings.com/works-with-smartthings/leviton/leviton-600w-incandescent-dimmer)
* [Enerwave In-Wall Dimmer](https://www.smartthings.com/works-with-smartthings/enerwave/enerwave-in-wall-dimmer-zw500d)
* [Leviton 3-Speed Fan Controller](https://www.smartthings.com/works-with-smartthings/leviton/leviton-3-speed-fan-controller)
* [Leviton Magnetic Low Voltage Dimmer](https://www.smartthings.com/works-with-smartthings/leviton/leviton-magnetic-low-voltage-dimmer)
* [Remotec Technology Plug-In Dimmer](https://www.smartthings.com/works-with-smartthings/remotec-technology/remotec-technology-plug-in-dimmer)
## Table of contents ## Table of contents
@@ -41,3 +47,8 @@ Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link: Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices) * [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton Universal Dimmer (DZMX1-LZ) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices) * [Leviton Universal Dimmer (DZMX1-LZ) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton 1000W Incandescent Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton 600W Incandescent Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton 3-Speed Fan Controller Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Enerwave In-Wall Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/204854176-How-to-connect-Enerwave-switches-and-dimmers)
* [Remotec Technology Plug-In Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202295150-Remotec-Technology-Plug-In-Dimmer-ZDS-100-)

View File

@@ -20,6 +20,7 @@ metadata {
capability "Polling" capability "Polling"
capability "Refresh" capability "Refresh"
capability "Sensor" capability "Sensor"
capability "Light"
fingerprint inClusters: "0x26", deviceJoinName: "Z-Wave Dimmer" fingerprint inClusters: "0x26", deviceJoinName: "Z-Wave Dimmer"
fingerprint mfr:"001D", prod:"1902", deviceJoinName: "Z-Wave Dimmer" fingerprint mfr:"001D", prod:"1902", deviceJoinName: "Z-Wave Dimmer"
@@ -28,6 +29,8 @@ metadata {
fingerprint mfr:"001D", prod:"1001", model:"0334", deviceJoinName: "Leviton 3-Speed Fan Controller" fingerprint mfr:"001D", prod:"1001", model:"0334", deviceJoinName: "Leviton 3-Speed Fan Controller"
fingerprint mfr:"001D", prod:"0602", model:"0334", deviceJoinName: "Leviton Magnetic Low Voltage Dimmer" fingerprint mfr:"001D", prod:"0602", model:"0334", deviceJoinName: "Leviton Magnetic Low Voltage Dimmer"
fingerprint mfr:"001D", prod:"0401", model:"0334", deviceJoinName: "Leviton 600W Incandescent Dimmer" fingerprint mfr:"001D", prod:"0401", model:"0334", deviceJoinName: "Leviton 600W Incandescent Dimmer"
fingerprint mfr:"0111", prod:"8200", model:"0200", deviceJoinName: "Remotec Technology Plug-In Dimmer"
fingerprint mfr:"1104", prod:"001D", model:"0501", deviceJoinName: "Leviton 1000W Incandescant Dimmer"
} }
simulator { simulator {

View File

@@ -25,6 +25,7 @@ metadata {
capability "Switch Level" capability "Switch Level"
capability "Sensor" capability "Sensor"
capability "Actuator" capability "Actuator"
capability "Light"
command "reset" command "reset"

View File

@@ -21,6 +21,7 @@ metadata {
capability "Refresh" capability "Refresh"
capability "Configuration" capability "Configuration"
capability "Sensor" capability "Sensor"
capability "Light"
command "reset" command "reset"

View File

@@ -19,6 +19,7 @@ metadata {
capability "Polling" capability "Polling"
capability "Refresh" capability "Refresh"
capability "Sensor" capability "Sensor"
capability "Light"
fingerprint inClusters: "0x25", deviceJoinName: "Z-Wave Switch" fingerprint inClusters: "0x25", deviceJoinName: "Z-Wave Switch"
fingerprint mfr:"001D", prod:"1A02", model:"0334", deviceJoinName: "Leviton Appliance Module" fingerprint mfr:"001D", prod:"1A02", model:"0334", deviceJoinName: "Leviton Appliance Module"
@@ -26,6 +27,8 @@ metadata {
fingerprint mfr:"001D", prod:"1D04", model:"0334", deviceJoinName: "Leviton Outlet" fingerprint mfr:"001D", prod:"1D04", model:"0334", deviceJoinName: "Leviton Outlet"
fingerprint mfr:"001D", prod:"1C02", model:"0334", deviceJoinName: "Leviton Switch" fingerprint mfr:"001D", prod:"1C02", model:"0334", deviceJoinName: "Leviton Switch"
fingerprint mfr:"001D", prod:"0301", model:"0334", deviceJoinName: "Leviton 15A Switch" fingerprint mfr:"001D", prod:"0301", model:"0334", deviceJoinName: "Leviton 15A Switch"
fingerprint mfr:"001D", prod:"0F01", model:"0334", deviceJoinName: "Leviton 5A Incandescent Switch"
fingerprint mfr:"001D", prod:"1603", model:"0334", deviceJoinName: "Leviton 15A Split Duplex Receptacle"
fingerprint mfr:"011A", prod:"0101", model:"0102", deviceJoinName: "Enerwave On/Off Switch" fingerprint mfr:"011A", prod:"0101", model:"0102", deviceJoinName: "Enerwave On/Off Switch"
fingerprint mfr:"011A", prod:"0101", model:"0603", deviceJoinName: "Enerwave Duplex Receptacle" fingerprint mfr:"011A", prod:"0101", model:"0603", deviceJoinName: "Enerwave Duplex Receptacle"
} }

View File

@@ -20,6 +20,7 @@ metadata {
capability "Refresh" capability "Refresh"
capability "Sensor" capability "Sensor"
capability "Health Check" capability "Health Check"
capability "Light"
fingerprint mfr:"0063", prod:"4952", deviceJoinName: "Z-Wave Wall Switch" fingerprint mfr:"0063", prod:"4952", deviceJoinName: "Z-Wave Wall Switch"
fingerprint mfr:"0063", prod:"5257", deviceJoinName: "Z-Wave Wall Switch" fingerprint mfr:"0063", prod:"5257", deviceJoinName: "Z-Wave Wall Switch"

View File

@@ -85,7 +85,8 @@ def bridgeDiscovery(params=[:])
} }
return dynamicPage(name:"bridgeDiscovery", title:"Discovery Started!", nextPage:"bridgeBtnPush", refreshInterval:refreshInterval, uninstall: true) { return dynamicPage(name:"bridgeDiscovery", title:"Discovery Started!", nextPage:"bridgeBtnPush", refreshInterval:refreshInterval, uninstall: true) {
section("Please wait while we discover your Hue Bridge. Discovery can take five minutes or more, so sit back and relax! Select your device below once discovered.") { section("Please wait while we discover your Hue Bridge. Kindly note that you must first configure your Hue Bridge and Lights using the Philips Hue application. " +
"Discovery can take five minutes or more, so sit back and relax! Select your device below once discovered.") {
input "selectedHue", "enum", required:false, title:"Select Hue Bridge (${numFound} found)", multiple:false, options:options, submitOnChange: true input "selectedHue", "enum", required:false, title:"Select Hue Bridge (${numFound} found)", multiple:false, options:options, submitOnChange: true
} }
} }
@@ -178,7 +179,7 @@ def bulbDiscovery() {
} }
if (bulbRefreshCount > 200 && numFound == 0) { if (bulbRefreshCount > 200 && numFound == 0) {
// Time out to avoid endless discovery // Time out after 10 minutes
state.inBulbDiscovery = false state.inBulbDiscovery = false
bulbRefreshCount = 0 bulbRefreshCount = 0
return dynamicPage(name:"bulbDiscovery", title:"Light Discovery Failed!", nextPage:"", refreshInterval:0, install:true, uninstall: true) { return dynamicPage(name:"bulbDiscovery", title:"Light Discovery Failed!", nextPage:"", refreshInterval:0, install:true, uninstall: true) {
@@ -1151,7 +1152,7 @@ def setColorTemperature(childDevice, huesettings) {
def ct = hueSettings == 6500 ? 153 : Math.round(1000000/huesettings) def ct = hueSettings == 6500 ? 153 : Math.round(1000000/huesettings)
createSwitchEvent(childDevice, "on") createSwitchEvent(childDevice, "on")
put("lights/$id/state", [ct: ct, on: true]) put("lights/$id/state", [ct: ct, on: true])
return "Setting color temperature to $percent" return "Setting color temperature to $ct"
} }
def setColor(childDevice, huesettings) { def setColor(childDevice, huesettings) {

View File

@@ -346,7 +346,7 @@ def devicesList(selector = '') {
if (resp.status == 200) { if (resp.status == 200) {
return resp.data return resp.data
} else { } else {
log.error("Non-200 from device list call. ${resp.status} ${resp.data}") log.debug("No response from device list call. ${resp.status} ${resp.data}")
return [] return []
} }
} }
@@ -418,9 +418,15 @@ def updateDevices() {
} }
getChildDevices().findAll { !selectors.contains("${it.deviceNetworkId}") }.each { getChildDevices().findAll { !selectors.contains("${it.deviceNetworkId}") }.each {
log.info("Deleting ${it.deviceNetworkId}") log.info("Deleting ${it.deviceNetworkId}")
if (state.devices[it.deviceNetworkId])
state.devices[it.deviceNetworkId] = null state.devices[it.deviceNetworkId] = null
// The reason the implementation is trying to delete this bulb is because it is not longer connected to the LIFX location.
// Adding "try" will prevent this exception from happening.
// Ideally device health would show to the user that the device is not longer accessible so that the user can either force delete it or remove it from the SmartApp.
try {
deleteChildDevice(it.deviceNetworkId) deleteChildDevice(it.deviceNetworkId)
} catch (Exception e) {
log.debug("Can't remove this device because it's being used by an SmartApp")
}
} }
} }