Clean up smartsense DTHs

This continues an effort to clean up the SmartSense DTHs and move as
much of the logic as possible into the library.  This simplifies the DTH
and has the advantage of having only a single location where issues need
to be fixed.
This commit is contained in:
Zach Varberg
2016-10-20 11:03:48 -05:00
parent db4f161e5d
commit 65d4a811b0
7 changed files with 346 additions and 1187 deletions

View File

@@ -15,7 +15,7 @@
*/
metadata {
// Automatically generated. Make future change here.
definition (name: "SmartPower Outlet", namespace: "smartthings", author: "SmartThings") {
definition(name: "SmartPower Outlet", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Switch"
capability "Power Meter"
@@ -24,9 +24,9 @@ metadata {
capability "Sensor"
capability "Health Check"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3200", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3200-Sgb", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "4257050-RZHAC", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3200", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3200-Sgb", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "4257050-RZHAC", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019"
}
@@ -44,32 +44,32 @@ metadata {
preferences {
section {
image(name: 'educationalcontent', multiple: true, images: [
"http://cdn.device-gse.smartthings.com/Outlet/US/OutletUS1.jpg",
"http://cdn.device-gse.smartthings.com/Outlet/US/OutletUS2.jpg"
])
"http://cdn.device-gse.smartthings.com/Outlet/US/OutletUS1.jpg",
"http://cdn.device-gse.smartthings.com/Outlet/US/OutletUS2.jpg"
])
}
}
// UI tile definitions
tiles(scale: 2) {
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
multiAttributeTile(name: "switch", type: "lighting", width: 6, height: 4, canChangeIcon: true) {
tileAttribute("device.switch", key: "PRIMARY_CONTROL") {
attributeState "on", label: 'On', action: "switch.off", icon: "st.switches.switch.on", backgroundColor: "#79b821", nextState: "turningOff"
attributeState "off", label: 'Off', action: "switch.on", icon: "st.switches.switch.off", backgroundColor: "#ffffff", nextState: "turningOn"
attributeState "turningOn", label: 'Turning On', action: "switch.off", icon: "st.switches.switch.on", backgroundColor: "#79b821", nextState: "turningOff"
attributeState "turningOff", label: 'Turning Off', action: "switch.on", icon: "st.switches.switch.off", backgroundColor: "#ffffff", nextState: "turningOn"
}
tileAttribute ("power", key: "SECONDARY_CONTROL") {
attributeState "power", label:'${currentValue} W'
tileAttribute("power", key: "SECONDARY_CONTROL") {
attributeState "power", label: '${currentValue} W'
}
}
standardTile("refresh", "device.power", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
state "default", label: '', action: "refresh.refresh", icon: "st.secondary.refresh"
}
main "switch"
details(["switch","refresh"])
details(["switch", "refresh"])
}
}
@@ -77,47 +77,29 @@ metadata {
def parse(String description) {
log.debug "description is $description"
def finalResult = zigbee.getKnownDescription(description)
def event = [:]
def event = zigbee.getEvent(description)
//TODO: Remove this after getKnownDescription can parse it automatically
if (!finalResult && description!="updated")
finalResult = getPowerDescription(zigbee.parseDescriptionAsMap(description))
if (finalResult) {
log.info "final result = $finalResult"
if (finalResult.type == "update") {
log.info "$device updates: ${finalResult.value}"
event = null
if (event) {
if (event.name == "power") {
event.value = event.value / 10
event.descriptionText = '{{ device.displayName }} power is {{ value }} Watts'
event.translatable = true
} else if (event.name == "switch") {
def descriptionText = event.value == "on" ? '{{ device.displayName }} is On' : '{{ device.displayName }} is Off'
event = createEvent(name: event.name, value: event.value, descriptionText: descriptionText, translatable: true)
}
else if (finalResult.type == "power") {
def powerValue = (finalResult.value as Integer)/10
event = createEvent(name: "power", value: powerValue, descriptionText: '{{ device.displayName }} power is {{ value }} Watts', translatable: true)
/*
Dividing by 10 as the Divisor is 10000 and unit is kW for the device. AttrId: 0302 and 0300. Simplifying to 10
power level is an integer. The exact power level with correct units needs to be handled in the device type
to account for the different Divisor value (AttrId: 0302) and POWER Unit (AttrId: 0300). CLUSTER for simple metering is 0702
*/
}
else {
def descriptionText = finalResult.value == "on" ? '{{ device.displayName }} is On' : '{{ device.displayName }} is Off'
event = createEvent(name: finalResult.type, value: finalResult.value, descriptionText: descriptionText, translatable: true)
}
}
else {
} else {
def cluster = zigbee.parse(description)
if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07){
if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07) {
if (cluster.data[0] == 0x00) {
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
event = createEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
else {
} else {
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
event = null
}
}
else {
} else {
log.warn "DID NOT PARSE MESSAGE for description : $description"
log.debug "${cluster}"
}
@@ -152,29 +134,3 @@ def configure() {
refresh() + zigbee.onOffConfig(0, 300) + zigbee.electricMeasurementPowerConfig()
}
private getEndpointId() {
new BigInteger(device.endpointId, 16).toString()
}
//TODO: Remove this after getKnownDescription can parse it automatically
def getPowerDescription(descMap) {
def powerValue = "undefined"
if (descMap.cluster == "0B04") {
if (descMap.attrId == "050b") {
if(descMap.value!="ffff")
powerValue = zigbee.convertHexToInt(descMap.value)
}
}
else if (descMap.clusterId == "0B04") {
if(descMap.command=="07"){
return [type: "update", value : "power (0B04) capability configured successfully"]
}
}
if (powerValue != "undefined"){
return [type: "power", value : powerValue]
}
else {
return [:]
}
}