@@ -0,0 +1,213 @@
/**
* Econet EV100 Vent
*
* Copyright 2014 SmartThings
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
*/
metadata {
// Automatically generated. Make future change here.
definition (name: "EcoNet Vent", namespace: "smartthings", author: "SmartThings") {
capability "Switch Level"
capability "Actuator"
capability "Switch"
capability "Battery"
capability "Refresh"
capability "Sensor"
capability "Polling"
capability "Configuration"
command "open"
command "close"
fingerprint deviceId: "0x1100", inClusters: "0x26,0x72,0x86,0x77,0x80,0x20"
}
simulator {
status "on": "command: 2603, payload: FF"
status "off": "command: 2603, payload: 00"
status "09%": "command: 2603, payload: 09"
status "10%": "command: 2603, payload: 0A"
status "33%": "command: 2603, payload: 21"
status "66%": "command: 2603, payload: 42"
status "99%": "command: 2603, payload: 63"
// reply messages
reply "2001FF,delay 100,2602": "command: 2603, payload: FF"
reply "200100,delay 100,2602": "command: 2603, payload: 00"
reply "200119,delay 100,2602": "command: 2603, payload: 19"
reply "200132,delay 100,2602": "command: 2603, payload: 32"
reply "20014B,delay 100,2602": "command: 2603, payload: 4B"
reply "200163,delay 100,2602": "command: 2603, payload: 63"
}
tiles {
standardTile("switch", "device.switch", width: 2, height: 2, canChangeIcon: true) {
state "on", action:"switch.off", icon:"st.vents.vent-open-text", backgroundColor:"#53a7c0"
state "off", action:"switch.on", icon:"st.vents.vent-closed", backgroundColor:"#ffffff"
}
valueTile("battery", "device.battery", inactiveLabel: false, decoration: "flat") {
state "battery", label:'${currentValue}% battery', unit:""
}
controlTile("levelSliderControl", "device.level", "slider", height: 1, width: 3, inactiveLabel: false) {
state "level", action:"switch level.setLevel"
}
standardTile("refresh", "device.switch", inactiveLabel: false, decoration: "flat") {
state "default", label:"", action:"refresh.refresh", icon:"st.secondary.refresh"
}
main(["switch"])
details(["switch","battery","refresh","levelSliderControl"])
}
}
def parse(String description) {
def result = []
def cmd = zwave.parse(description, [0x20: 1, 0x26: 3, 0x70: 1, 0x32:3])
if (cmd) {
result = zwaveEvent(cmd)
log.debug("'$description' parsed to $result")
} else {
log.debug("Couldn't zwave.parse '$description'")
}
result
}
//send the command to stop polling
def updated() {
response("poll stop")
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
dimmerEvents(cmd) + [ response("poll stop") ] // we get a BasicReport when the hub starts polling
}
//parse manufacture name and store it
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerSpecificReport cmd) {
if (state.manufacturer != cmd.manufacturerName) {
updateDataValue("manufacturer", cmd.manufacturerName)
}
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd) {
dimmerEvents(cmd)
}
def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelReport cmd) {
dimmerEvents(cmd)
}
def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv3.SwitchMultilevelReport cmd) {
dimmerEvents(cmd)
}
def dimmerEvents(physicalgraph.zwave.Command cmd) {
def text = "$device.displayName is ${cmd.value ? "open" : "closed"}"
def switchEvent = createEvent(name: "switch", value: (cmd.value ? "on" : "off"), descriptionText: text)
def levelEvent = createEvent(name:"level", value: cmd.value, unit:"%")
[switchEvent, levelEvent]
}
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def map = [ name: "battery", unit: "%" ]
if (cmd.batteryLevel == 0xFF) {
map.value = 1
map.descriptionText = "${device.displayName} has a low battery"
map.isStateChange = true
} else {
map.value = cmd.batteryLevel
}
state.lastbat = new Date().time
createEvent(map)
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
def linkText = device.label ?: device.name
[linkText: linkText, descriptionText: "$linkText: $cmd", displayed: false]
}
def on() {
delayBetween([
zwave.basicV1.basicSet(value: 0xFF).format(),
zwave.switchMultilevelV1.switchMultilevelGet().format()
])
}
def open() {
on()
}
def off() {
delayBetween([
zwave.basicV1.basicSet(value: 0x00).format(),
zwave.switchMultilevelV1.switchMultilevelGet().format()
])
}
def close() {
off()
}
def setLevel(value) {
delayBetween([
zwave.basicV1.basicSet(value: value).format(),
zwave.switchMultilevelV1.switchMultilevelGet().format()
])
}
def setLevel(value, duration) {
setLevel(value)
}
def refresh() {
delayBetween([
zwave.switchMultilevelV1.switchMultilevelGet().format(),
zwave.batteryV1.batteryGet().format()
], 2200)
}
//poll for battery once a day
def poll() {
if (secondsPast(state.lastbatt, 36*60*60)) {
return zwave.batteryV1.batteryGet().format()
} else {
return zwave.switchMultilevelV1.switchMultilevelGet().format()
}
}
def configure() {
[
zwave.manufacturerSpecificV1.manufacturerSpecificGet().format()
]
refresh()
}
//check last message so battery poll doesn't happen all the time
private Boolean secondsPast(timestamp, seconds) {
if (!(timestamp instanceof Number)) {
if (timestamp instanceof Date) {
timestamp = timestamp.time
} else if ((timestamp instanceof String) && timestamp.isNumber()) {
timestamp = timestamp.toLong()
} else {
return true
}
}
return (new Date().time - timestamp) > (seconds * 1000)
}
//Warn message for unkown events
def createEvents(physicalgraph.zwave.Command cmd) {
log.warn "UNEXPECTED COMMAND: $cmd"
}