mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-21 05:10:50 +00:00
[CHF-417] [CHF-416] Health Check devices enroll with appropriate checkInterval
This commit is contained in:
@@ -16,7 +16,7 @@
|
||||
|
||||
metadata {
|
||||
// Automatically generated. Make future change here.
|
||||
definition (name: "SmartPower Outlet", namespace: "smartthings", author: "SmartThings", category: "C1") {
|
||||
definition (name: "SmartPower Outlet", namespace: "smartthings", author: "SmartThings") {
|
||||
capability "Actuator"
|
||||
capability "Switch"
|
||||
capability "Power Meter"
|
||||
@@ -104,8 +104,21 @@ def parse(String description) {
|
||||
}
|
||||
}
|
||||
else {
|
||||
log.warn "DID NOT PARSE MESSAGE for description : $description"
|
||||
log.debug zigbee.parseDescriptionAsMap(description)
|
||||
def cluster = zigbee.parse(description)
|
||||
|
||||
if (cluster.clusterId == 0x0006 && cluster.command == 0x07){
|
||||
if (cluster.data[0] == 0x00) {
|
||||
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
|
||||
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
else {
|
||||
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
|
||||
}
|
||||
}
|
||||
else {
|
||||
log.warn "DID NOT PARSE MESSAGE for description : $description"
|
||||
log.debug "${cluster}"
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
@@ -128,8 +141,10 @@ def refresh() {
|
||||
}
|
||||
|
||||
def configure() {
|
||||
// Device-Watch allows 2 check-in misses from device
|
||||
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
|
||||
// enrolls with default periodic reporting until newer 5 min interval is confirmed
|
||||
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
zigbee.onOffConfig(0, 300) + powerConfig() + refresh()
|
||||
}
|
||||
|
||||
Reference in New Issue