CHF-435
Implementation of Health Check for Zigbee Dimmer (GE Plug-In/In-Wall Smart Dimmer)
This commit is contained in:
@@ -0,0 +1,2 @@
|
|||||||
|
.st-ignore
|
||||||
|
README.md
|
||||||
41
devicetypes/smartthings/zigbee-dimmer-power.src/README.md
Normal file
41
devicetypes/smartthings/zigbee-dimmer-power.src/README.md
Normal file
@@ -0,0 +1,41 @@
|
|||||||
|
# GE Plug-In/In-Wall Smart Dimmer (ZigBee)
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
Works with:
|
||||||
|
|
||||||
|
* [GE In-Wall Smart Dimmer (ZigBee)](https://shop.smartthings.com/#!/products/ge-in-wall-smart-dimmer-switch)
|
||||||
|
* [GE Plug-In Smart Dimmer (ZigBee)](https://www.smartthings.com/works-with-smartthings/ge/ge-plug-in-smart-dimmer-zigbee)
|
||||||
|
|
||||||
|
## Table of contents
|
||||||
|
|
||||||
|
* [Capabilities](#capabilities)
|
||||||
|
* [Health](#device-health)
|
||||||
|
* [Troubleshooting](#Troubleshooting)
|
||||||
|
|
||||||
|
## Capabilities
|
||||||
|
|
||||||
|
* **Actuator** - represents that a Device has commands
|
||||||
|
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
|
||||||
|
* **Refresh** - _refresh()_ command for status updates
|
||||||
|
* **Power Meter** - ability to check the power meter(energy consumption) of device
|
||||||
|
* **Sensor** - represents the device sensor capability
|
||||||
|
* **Switch** - can detect state (possible values: on/off)
|
||||||
|
* **Switch Level** - represents current light level, usually 0-100 in percent
|
||||||
|
* **Health Check** - indicates ability to get device health notifications
|
||||||
|
|
||||||
|
## Device Health
|
||||||
|
|
||||||
|
A Zigbee dimmer with maxReportTime of 5 mins.
|
||||||
|
Check-in interval is double the value of maxReportTime.
|
||||||
|
This gives the device twice the amount of time to respond before it is marked as offline.
|
||||||
|
Enrolls with default periodic reporting until newer 5 min interval is confirmed
|
||||||
|
It then enrolls the device with updated checkInterval i.e. 12 mins
|
||||||
|
|
||||||
|
## Troubleshooting
|
||||||
|
|
||||||
|
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||||
|
Pairing needs to be tried again by placing the device closer to the hub.
|
||||||
|
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||||
|
* [GE Z-Wave In-Wall Smart Dimmer (GE 45857) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/204988564-GE-In-Wall-Smart-Dimmer-45857GE-ZigBee-)
|
||||||
|
* [GE Zigbee Plug-in Smart Dimmer (GE 45852) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205239280-GE-Plug-In-Smart-Dimmer-45852GE-ZigBee-)
|
||||||
@@ -21,6 +21,7 @@ metadata {
|
|||||||
capability "Sensor"
|
capability "Sensor"
|
||||||
capability "Switch"
|
capability "Switch"
|
||||||
capability "Switch Level"
|
capability "Switch Level"
|
||||||
|
capability "Health Check"
|
||||||
|
|
||||||
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B04"
|
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B04"
|
||||||
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702"
|
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702"
|
||||||
@@ -70,8 +71,20 @@ def parse(String description) {
|
|||||||
}
|
}
|
||||||
}
|
}
|
||||||
else {
|
else {
|
||||||
log.warn "DID NOT PARSE MESSAGE for description : $description"
|
def cluster = zigbee.parse(description)
|
||||||
log.debug zigbee.parseDescriptionAsMap(description)
|
if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07) {
|
||||||
|
if (cluster.data[0] == 0x00){
|
||||||
|
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
|
||||||
|
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||||
|
}
|
||||||
|
else {
|
||||||
|
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
|
||||||
|
}
|
||||||
|
}
|
||||||
|
else {
|
||||||
|
log.warn "DID NOT PARSE MESSAGE for description : $description"
|
||||||
|
log.debug zigbee.parseDescriptionAsMap(description)
|
||||||
|
}
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
@@ -87,11 +100,22 @@ def setLevel(value) {
|
|||||||
zigbee.setLevel(value)
|
zigbee.setLevel(value)
|
||||||
}
|
}
|
||||||
|
|
||||||
|
/**
|
||||||
|
* PING is used by Device-Watch in attempt to reach the Device
|
||||||
|
* */
|
||||||
|
def ping() {
|
||||||
|
return zigbee.onOffRefresh()
|
||||||
|
}
|
||||||
|
|
||||||
def refresh() {
|
def refresh() {
|
||||||
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.simpleMeteringPowerRefresh() + zigbee.electricMeasurementPowerRefresh() + zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.simpleMeteringPowerConfig() + zigbee.electricMeasurementPowerConfig()
|
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.simpleMeteringPowerRefresh() + zigbee.electricMeasurementPowerRefresh() + zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.simpleMeteringPowerConfig() + zigbee.electricMeasurementPowerConfig()
|
||||||
}
|
}
|
||||||
|
|
||||||
def configure() {
|
def configure() {
|
||||||
log.debug "Configuring Reporting and Bindings."
|
log.debug "Configuring Reporting and Bindings."
|
||||||
|
|
||||||
|
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
|
||||||
|
// enrolls with default periodic reporting until newer 5 min interval is confirmed
|
||||||
|
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||||
refresh()
|
refresh()
|
||||||
}
|
}
|
||||||
|
|||||||