mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-19 13:20:53 +00:00
[CHF-459] Health documentation include DTH execution location and expected checkInterval; reduced checkInterval
This commit is contained in:
@@ -1,6 +1,6 @@
|
||||
# GE Plug-In/In-Wall Smart Dimmer (ZigBee)
|
||||
|
||||
|
||||
Cloud Execution
|
||||
|
||||
Works with:
|
||||
|
||||
@@ -26,11 +26,11 @@ Works with:
|
||||
|
||||
## Device Health
|
||||
|
||||
A Zigbee dimmer with maxReportTime of 5 mins.
|
||||
Check-in interval is double the value of maxReportTime.
|
||||
This gives the device twice the amount of time to respond before it is marked as offline.
|
||||
Enrolls with default periodic reporting until newer 5 min interval is confirmed
|
||||
It then enrolls the device with updated checkInterval i.e. 12 mins
|
||||
A Zigbee Power Dimmer with reporting interval of 5 mins.
|
||||
SmartThings platform will ping the device after `checkInterval` seconds of inactivity in last attempt to reach the device before marking it `OFFLINE`
|
||||
|
||||
* __12min__ checkInterval
|
||||
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
|
||||
@@ -114,8 +114,8 @@ def refresh() {
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
|
||||
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
|
||||
// Device-Watch allows 2 check-in misses from device + ping (plus 1 min lag time)
|
||||
// enrolls with default periodic reporting until newer 5 min interval is confirmed
|
||||
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
sendEvent(name: "checkInterval", value: 2 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
refresh()
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user