This changes our smartsense DTHs that don't use the ZigBee library for
everything to have larger delays between ZigBee messages. This is to
reduce the network load to try to work around some of the poorer
behaving ZigBee routers we support.
This resolves: https://smartthings.atlassian.net/browse/DPROT-223
The bug causing level events not to be created happens when the setLevel
command runs in the cloud but the Device Type Handler is running locally
in the hub. Since state is not synced from the cloud to the hub the
`state.trigger` value was never set to `"setLevel"` on the hub which means
no level events would be created. The change is to not be reliant on state.
Instead we just don't create level events if the level is 0 since there is
no legitimate way for the level to be 0.
https://smartthings.atlassian.net/browse/DVCSMP-2219
updating parse
deleting unused code
updating the config method
adding logic to refresh after the dimming is complete for any rate specified by the user
multi tiles for ge link