Compare commits

...

20 Commits

Author SHA1 Message Date
Vinay Rao
a7cd9e072b Merge pull request #1078 from SmartThingsCommunity/staging
Rolling up staging to production for deploy
2016-07-26 13:45:49 -07:00
Vinay Rao
b5843acc38 Merge pull request #1067 from SmartThingsCommunity/master
Rolling up master to staging
2016-07-19 16:00:31 -07:00
Vinay Rao
863c49ffd4 Merge pull request #1066 from SmartThingsCommunity/staging
Rolling down staging hotfix to production
2016-07-19 15:55:53 -07:00
Vinay Rao
4e5d1f6ad0 Merge pull request #1065 from SmartThingsCommunity/staging
Rolling up staging to production for deploy
2016-07-19 15:09:07 -07:00
Vinay Rao
2f0d8d814b Merge pull request #1064 from SmartThingsCommunity/production
Rolling down production hotfix to staging
2016-07-19 15:06:43 -07:00
Vinay Rao
a86eba494f Merge pull request #1063 from tslagle13/add-capability-SS-open/closed
Add capability sensor to SS Open/Closed
2016-07-18 15:46:21 -07:00
tslagle13
2549372bb7 Add capability sensor to SS Open/Closed
There are some integrations out there using the "Actuator" and "Sensor" Capabilities and this doesn't show up for them.
2016-07-18 15:20:06 -07:00
Vinay Rao
38cdde7479 Merge pull request #1057 from SmartThingsCommunity/DVCSMP-1892
DVCSMP-1892 Fix error in Z-Wave Door/Window Sensor wake up handler
2016-07-14 10:54:36 -07:00
Duncan McKee
853f616cc8 DVCSMP-1892 Fix error in Z-Wave Door/Window Sensor wake up handler 2016-07-14 13:51:36 -04:00
Vinay Rao
2b3a4e1278 Merge pull request #1055 from SmartThingsCommunity/staging
Rolling down staging hotfix to master
2016-07-13 19:45:29 -07:00
Vinay Rao
825e693efd Merge pull request #1054 from SmartThingsCommunity/production
Rolling down prod hotfix to staging
2016-07-13 19:44:57 -07:00
Vinay Rao
686c8f7337 Merge pull request #1053 from rappleg/FixFalseBatteryNotificationOnNewerGroovyVersion
PRP-192 Fix false low battery notifications on Groovy 2.4.4
2016-07-13 19:40:55 -07:00
rappleg
11f4e42fe9 PRP-192 Fix false low battery notifications on Groovy 2.4.4 2016-07-13 21:22:57 -05:00
Steve Vlaminck
bc459ae178 Merge pull request #1051 from vlaminck/GWU-exception-fix
fix divide by zero exception [DVCSMP-1891]
2016-07-13 10:01:10 -05:00
vlaminck
1392b6e1a5 fix divide by zero exception 2016-07-13 09:27:23 -05:00
Vinay Rao
3db96faa00 Merge pull request #1049 from SmartThingsCommunity/master
Rolling up master to staging
2016-07-12 15:04:26 -07:00
Vinay Rao
399fbcb676 Merge pull request #1048 from SmartThingsCommunity/staging
Rolling down staging hotfix to master
2016-07-12 15:03:28 -07:00
Jack Chi
3472ee329d Merge pull request #1036 from jackchi/healthcheck-zwave-aeon
[CHF-138] Adds HealthCheck to Z-Wave Sensors
2016-07-11 11:21:30 -07:00
Juan Pablo Risso
577b127287 PRP-151 Harmony cloud fix + PENG-161 - Allow setLevel (#1035)
* PRP-151 - Harmony Cloud

Added is IP

Try around Integer.parseInt

declare int p outside try

* Remove unsubscribe & unschedule

* PENG-161 - Allow setLevel for switch capability

Last version
2016-07-11 10:04:32 -04:00
jackchi
5f41af35e2 [CHF-138] Adds HealthCheck to Z-Wave Sensors 2016-07-08 15:36:58 -07:00
14 changed files with 103 additions and 80 deletions

View File

@@ -22,6 +22,7 @@ metadata {
capability "Configuration"
capability "Sensor"
capability "Battery"
capability "Health Check"
attribute "tamper", "enum", ["detected", "clear"]
attribute "batteryStatus", "string"
@@ -326,6 +327,9 @@ def zwaveEvent(physicalgraph.zwave.Command cmd) {
}
def configure() {
// allow device user configured or default 16 min to check in; double the periodic reporting interval
sendEvent(name: "checkInterval", value: 2* timeOptionValueMap[reportInterval] ?: 2*8*60, displayed: false)
// This sensor joins as a secure device if you double-click the button to include it
log.debug "${device.displayName} is configuring its settings"
def request = []

View File

@@ -20,6 +20,9 @@ metadata {
capability "Configuration"
capability "Sensor"
capability "Battery"
capability "Health Check"
command "configureAfterSecure"
fingerprint deviceId: "0x0701", inClusters: "0x5E,0x86,0x72,0x59,0x85,0x73,0x71,0x84,0x80,0x30,0x31,0x70,0x98,0x7A", outClusters:"0x5A"
}
@@ -245,6 +248,8 @@ def configureAfterSecure() {
def configure() {
// log.debug "configure()"
//["delay 30000"] + secure(zwave.securityV1.securityCommandsSupportedGet())
// allow device 16 min to check in; double the periodic reporting interval
sendEvent(name: "checkInterval", value: 2*8*60, displayed: false)
}
private setConfigured() {

View File

@@ -20,6 +20,7 @@ metadata {
capability "Illuminance Measurement"
capability "Sensor"
capability "Battery"
capability "Health Check"
fingerprint deviceId: "0x2001", inClusters: "0x30,0x31,0x80,0x84,0x70,0x85,0x72,0x86"
}
@@ -180,6 +181,9 @@ def zwaveEvent(physicalgraph.zwave.Command cmd) {
}
def configure() {
// allow device 10 min to check in; double the periodic reporting interval
sendEvent(name: "checkInterval", value: 2*5*60, displayed: false)
delayBetween([
// send binary sensor report instead of basic set for motion
zwave.configurationV1.configurationSet(parameterNumber: 5, size: 1, scaledConfigurationValue: 2).format(),

View File

@@ -255,7 +255,8 @@ private Map getBatteryResult(rawValue) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
result.value = Math.min(100, (int) pct * 100)
def roundedPct = Math.round(pct * 100)
result.value = Math.min(100, roundedPct)
result.descriptionText = "{{ device.displayName }} battery was {{ value }}%"
}
}

View File

@@ -271,7 +271,8 @@ private Map getBatteryResult(rawValue) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
result.value = Math.min(100, (int) pct * 100)
def roundedPct = Math.round(pct * 100)
result.value = Math.min(100, roundedPct)
result.descriptionText = "{{ device.displayName }} battery was {{ value }}%"
}
}

View File

@@ -240,7 +240,8 @@ private Map getBatteryResult(rawValue) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
result.value = Math.min(100, (int) pct * 100)
def roundedPct = Math.round(pct * 100)
result.value = Math.min(100, roundedPct)
result.descriptionText = "${linkText} battery was ${result.value}%"
}
}

View File

@@ -338,7 +338,8 @@ private Map getBatteryResult(rawValue) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
result.value = Math.min(100, (int) pct * 100)
def roundedPct = Math.round(pct * 100)
result.value = Math.min(100, roundedPct)
result.descriptionText = "{{ device.displayName }} battery was {{ value }}%"
}
}

View File

@@ -234,7 +234,8 @@ def getTemperature(value) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
result.value = Math.min(100, (int) pct * 100)
def roundedPct = Math.round(pct * 100)
result.value = Math.min(100, roundedPct)
result.descriptionText = "${linkText} battery was ${result.value}%"
}

View File

@@ -22,6 +22,7 @@ metadata {
capability "Refresh"
capability "Temperature Measurement"
capability "Health Check"
capability "Sensor"
command "enrollResponse"
@@ -229,7 +230,8 @@ private Map getBatteryResult(rawValue) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
result.value = Math.min(100, (int) pct * 100)
def roundedPct = Math.round(pct * 100)
result.value = Math.min(100, roundedPct)
result.descriptionText = "${linkText} battery was ${result.value}%"
}

View File

@@ -205,7 +205,8 @@ private Map getBatteryResult(rawValue) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
result.value = Math.min(100, (int) pct * 100)
def roundedPct = Math.round(pct * 100)
result.value = Math.min(100, roundedPct)
result.descriptionText = "${linkText} battery was ${result.value}%"
}

View File

@@ -223,7 +223,8 @@ private Map getBatteryResult(rawValue) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
result.value = Math.min(100, (int) pct * 100)
def roundedPct = Math.round(pct * 100)
result.value = Math.min(100, roundedPct)
result.descriptionText = "${linkText} battery was ${result.value}%"
}

View File

@@ -35,6 +35,7 @@ metadata {
// status messages
status "open": "command: 2001, payload: FF"
status "closed": "command: 2001, payload: 00"
status "wake up": "command: 8407, payload: "
}
// UI tile definitions
@@ -174,7 +175,7 @@ def zwaveEvent(physicalgraph.zwave.commands.wakeupv1.WakeUpNotification cmd)
if (!state.lastbat || now() - state.lastbat > 53*60*60*1000) {
cmds << command(zwave.batteryV1.batteryGet())
} else {
cmds << zwave.wakeUpV1.wakeUpNoMoreInformation()
cmds << zwave.wakeUpV1.wakeUpNoMoreInformation().format()
}
[event, response(cmds)]
}

View File

@@ -720,7 +720,7 @@ def completionPercentage() {
def now = new Date().getTime()
def timeElapsed = now - atomicState.start
def totalRunTime = totalRunTimeMillis()
def totalRunTime = totalRunTimeMillis() ?: 1
def percentComplete = timeElapsed / totalRunTime * 100
log.debug "percentComplete: ${percentComplete}"

View File

@@ -688,7 +688,7 @@ def validateCommand(device, command) {
def capabilityCommands = getDeviceCapabilityCommands(device.capabilities)
def currentDeviceCapability = getCapabilityName(device)
if (currentDeviceCapability != "" && capabilityCommands[currentDeviceCapability]) {
return command in capabilityCommands[currentDeviceCapability] ? true : false
return (command in capabilityCommands[currentDeviceCapability] || (currentDeviceCapability == "Switch" && command == "setLevel" && device.hasCommand("setLevel"))) ? true : false
} else {
// Handling other device types here, which don't accept commands
httpError(400, "Bad request.")