Files
Zach Varberg 8bcbe7b924 Fix sengled use of FF for max level
This works around the fact that sengled element touches can get back
into a state of reporting an invalid value (of FF) if the physical
button on the bulb is used to cycle back to the 100% state.  Here we
interpret FF as FE for sengled and then issue a move to level command to
put it in a state where it will report FE until the level is changed
again.

This resolves: https://smartthings.atlassian.net/browse/DVCSMP-2597
2017-04-24 09:49:02 -05:00
..
2016-10-24 14:26:22 +05:30

GE Plug-In/In-Wall Smart Dimmer (ZigBee)

Cloud Execution

Works with:

Table of contents

Capabilities

  • Actuator - represents that a Device has commands
  • Configuration - configure() command called when device is installed or device preferences updated
  • Refresh - refresh() command for status updates
  • Power Meter - ability to check the power meter(energy consumption) of device
  • Sensor - represents the device sensor capability
  • Switch - can detect state (possible values: on/off)
  • Switch Level - represents current light level, usually 0-100 in percent
  • Health Check - indicates ability to get device health notifications
  • Light - indicates that the device belongs to Light category.

Device Health

A Zigbee Power Dimmer with reporting interval of 5 mins. SmartThings platform will ping the device after checkInterval seconds of inactivity in last attempt to reach the device before marking it OFFLINE

  • 12min checkInterval

Troubleshooting

If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range. Pairing needs to be tried again by placing the device closer to the hub. Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link: