Support config on both temp-humidty firmwares
This solves an issue with invalid configuration of the reporting for humidity on the smartsense-temp-humidity-sensor. This issue was masked by the fact that the device has a default configuration for reporting humidity, but the configuration has never been valid as it used an incorrect dataType for the configuration. This resolves: https://smartthings.atlassian.net/browse/DPROT-263 This resolves: https://smartthings.atlassian.net/browse/EBF-1205 This resolves: https://smartthings.atlassian.net/browse/DVCSMP-2420
This commit is contained in:
@@ -135,10 +135,7 @@ def refresh() {
|
||||
return zigbee.readAttribute(0xFC45, 0x0000, ["mfgCode": 0x104E]) + // New firmware
|
||||
zigbee.readAttribute(0xFC45, 0x0000, ["mfgCode": 0xC2DF]) + // Original firmware
|
||||
zigbee.readAttribute(zigbee.TEMPERATURE_MEASUREMENT_CLUSTER, 0x0000) +
|
||||
zigbee.readAttribute(zigbee.POWER_CONFIGURATION_CLUSTER, 0x0020) +
|
||||
zigbee.configureReporting(0xFC45, 0x0000, DataType.INT16, 30, 3600, 100) +
|
||||
zigbee.batteryConfig() +
|
||||
zigbee.temperatureConfig(30, 300)
|
||||
zigbee.readAttribute(zigbee.POWER_CONFIGURATION_CLUSTER, 0x0020)
|
||||
}
|
||||
|
||||
def configure() {
|
||||
@@ -150,5 +147,10 @@ def configure() {
|
||||
|
||||
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
// battery minReport 30 seconds, maxReportTime 6 hrs by default
|
||||
return refresh()
|
||||
return refresh() +
|
||||
zigbee.configureReporting(0xFC45, 0x0000, DataType.UINT16, 30, 3600, 100, ["mfgCode": 0x104E]) + // New firmware
|
||||
zigbee.configureReporting(0xFC45, 0x0000, DataType.UINT16, 30, 3600, 100, ["mfgCode": 0xC2DF]) + // Original firmware
|
||||
zigbee.batteryConfig() +
|
||||
zigbee.temperatureConfig(30, 300)
|
||||
|
||||
}
|
||||
|
||||