@@ -287,7 +287,8 @@ def isDescriptionPower(descMap) {
def powerValue = "undefined"
if (descMap.cluster == "0B04") {
if (descMap.attrId == "050b") {
powerValue = convertHexToInt(descMap.value)
if(descMap.value!="ffff")
powerValue = convertHexToInt(descMap.value)
}
}
else if (descMap.clusterId == "0B04") {
@@ -327,10 +328,9 @@ def levelConfig() {
//min change in value is 05
def powerConfig() {
[
//Meter (Power) Reporting
"zdo bind 0x${device.deviceNetworkId} 1 ${endpointId} 0x0B04 {${device.zigbeeId}} {}", "delay 200",
"zcl global send-me-a-report 0x0B04 0x050B 0x2A 1 600 {05}",
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 1500"
"zdo bind 0x${device.deviceNetworkId} 1 ${endpointId} 0x0B04 {${device.zigbeeId}} {}", "delay 200",
"zcl global send-me-a-report 0x0B04 0x050B 0x29 1 600 {05 00}", //The send-me-a-report is custom to the attribute type for CentraLite
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500"
]
}

View File

@@ -1,8 +1,19 @@
/**
* CentraLite Switch
* Copyright 2015 SmartThings
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
* SmartPower Outlet (CentraLite)
*
* Author: SmartThings
* Date: 2013-12-02
* Date: 2015-08-23
*/
metadata {
// Automatically generated. Make future change here.
@@ -35,18 +46,20 @@ metadata {
tiles(scale: 2) {
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
attributeState "off", label: '${name}', action: "switch.on", icon: "st.switches.switch.off", backgroundColor: "#ffffff"
attributeState "on", label: '${name}', action: "switch.off", icon: "st.switches.switch.on", backgroundColor: "#79b821"
attributeState "on", label: '${name}', action: "switch.off", icon: "st.switches.switch.on", backgroundColor: "#79b821", nextState: "turningOff"
attributeState "off", label: '${name}', action: "switch.on", icon: "st.switches.switch.off", backgroundColor: "#ffffff", nextState: "turningOn"
attributeState "turningOn", label: '${name}', action: "switch.off", icon: "st.switches.switch.on", backgroundColor: "#79b821", nextState: "turningOff"
attributeState "turningOff", label: '${name}', action: "switch.on", icon: "st.switches.switch.off", backgroundColor: "#ffffff", nextState: "turningOn"
}
tileAttribute ("power", key: "SECONDARY_CONTROL") {
attributeState "power", label:'${currentValue} W'
}
}
standardTile("refresh", "device.power", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
}
main "switch"
details(["switch","refresh"])
}
@@ -54,67 +67,88 @@ metadata {
// Parse incoming device messages to generate events
def parse(String description) {
log.debug "Parse description $description"
def name = null
def value = null
log.debug "description is $description"
// save heartbeat (i.e. last time we got a message from device)
state.heartbeat = Calendar.getInstance().getTimeInMillis()
def finalResult = zigbee.getKnownDescription(description)
if (description?.startsWith("read attr -")) {
def descMap = parseDescriptionAsMap(description)
log.debug "Read attr: $description"
if (descMap.cluster == "0006" && descMap.attrId == "0000") {
name = "switch"
value = descMap.value.endsWith("01") ? "on" : "off"
} else if (descMap.cluster.equalsIgnoreCase("0B04") && descMap.attrId.equalsIgnoreCase("050b")) {
def reportValue = descMap.value
name = "power"
//power divisor is 10
value = Integer.parseInt(reportValue, 16) / 10
//TODO: Remove this after getKnownDescription can parse it automatically
if (!finalResult && description!="updated")
finalResult = getPowerDescription(zigbee.parseDescriptionAsMap(description))
if (finalResult) {
log.info finalResult
if (finalResult.type == "update") {
log.info "$device updates: ${finalResult.value}"
}
else if (finalResult.type == "power") {
def powerValue = (finalResult.value as Integer)/10
sendEvent(name: "power", value: powerValue)
/*
Dividing by 10 as the Divisor is 10000 and unit is kW for the device. AttrId: 0302 and 0300. Simplifying to 10
power level is an integer. The exact power level with correct units needs to be handled in the device type
to account for the different Divisor value (AttrId: 0302) and POWER Unit (AttrId: 0300). CLUSTER for simple metering is 0702
*/
}
else {
sendEvent(name: finalResult.type, value: finalResult.value)
}
} else if (description?.startsWith("on/off:")) {
log.debug "Switch command"
name = "switch"
value = description?.endsWith(" 1") ? "on" : "off"
}
def result = createEvent(name: name, value: value)
log.debug "Parse returned ${result?.descriptionText}"
return result
}
def parseDescriptionAsMap(description) {
(description - "read attr - ").split(",").inject([:]) { map, param ->
def nameAndValue = param.split(":")
map += [(nameAndValue[0].trim()):nameAndValue[1].trim()]
else {
log.warn "DID NOT PARSE MESSAGE for description : $description"
log.debug zigbee.parseDescriptionAsMap(description)
}
}
// Commands to device
def on() {
'zcl on-off on'
}
def off() {
'zcl on-off off'
zigbee.off()
}
def meter() {
"st rattr 0x${device.deviceNetworkId} 1 0xB04 0x50B"
def on() {
zigbee.on()
}
def refresh() {
sendEvent(name: "heartbeat", value: "alive", displayed:false)
[
"st rattr 0x${device.deviceNetworkId} 1 0xB04 0x50B"
]
zigbee.onOffRefresh() + zigbee.refreshData("0x0B04", "0x050B")
}
def configure() {
def configCmds = [
"zdo bind 0x${device.deviceNetworkId} 1 1 6 {${device.zigbeeId}} {}", "delay 200",
"zdo bind 0x${device.deviceNetworkId} 1 1 0xB04 {${device.zigbeeId}} {}", "delay 200"
]
return configCmds + refresh() // send refresh cmds as part of config
zigbee.onOffConfig() + powerConfig() + refresh()
}
//power config for devices with min reporting interval as 1 seconds and reporting interval if no activity as 10min (600s)
//min change in value is 01
def powerConfig() {
[
"zdo bind 0x${device.deviceNetworkId} 1 ${endpointId} 0x0B04 {${device.zigbeeId}} {}", "delay 200",
"zcl global send-me-a-report 0x0B04 0x050B 0x29 1 600 {05 00}", //The send-me-a-report is custom to the attribute type for CentraLite
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500"
]
}
private getEndpointId() {
new BigInteger(device.endpointId, 16).toString()
}
//TODO: Remove this after getKnownDescription can parse it automatically
def getPowerDescription(descMap) {
def powerValue = "undefined"
if (descMap.cluster == "0B04") {
if (descMap.attrId == "050b") {
if(descMap.value!="ffff")
powerValue = zigbee.convertHexToInt(descMap.value)
}
}
else if (descMap.clusterId == "0B04") {
if(descMap.command=="07"){
return [type: "update", value : "power (0B04) capability configured successfully"]
}
}
if (powerValue != "undefined"){
return [type: "power", value : powerValue]
}
else {
return [:]
}
}