mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-15 05:10:50 +00:00
Merge pull request #1342 from james-smartthings/DVCSMP-2013-temperature-scale-change-bug-fix
DVCSMP-2013 - Temperature Scale Change bug fix
This commit is contained in:
@@ -148,14 +148,12 @@ def generateEvent(Map results) {
|
||||
handlerName: name]
|
||||
|
||||
if (name=="temperature" || name=="heatingSetpoint" || name=="coolingSetpoint" ) {
|
||||
def sendValue = convertTemperatureIfNeeded(value.toDouble(), "F", 1) //API return temperature value in F
|
||||
sendValue = location.temperatureScale == "C"? roundC(sendValue) : sendValue
|
||||
def sendValue = location.temperatureScale == "C"? roundC(convertFtoC(value.toDouble())) : value.toInteger()
|
||||
isChange = isTemperatureStateChange(device, name, value.toString())
|
||||
isDisplayed = isChange
|
||||
event << [value: sendValue, unit: temperatureScale, isStateChange: isChange, displayed: isDisplayed]
|
||||
} else if (name=="maxCoolingSetpoint" || name=="minCoolingSetpoint" || name=="maxHeatingSetpoint" || name=="minHeatingSetpoint") {
|
||||
def sendValue = convertTemperatureIfNeeded(value.toDouble(), "F", 1) //API return temperature value in F
|
||||
sendValue = location.temperatureScale == "C"? roundC(sendValue) : sendValue
|
||||
def sendValue = location.temperatureScale == "C"? roundC(convertFtoC(value.toDouble())) : value.toInteger()
|
||||
event << [value: sendValue, unit: temperatureScale, displayed: false]
|
||||
} else if (name=="heatMode" || name=="coolMode" || name=="autoMode" || name=="auxHeatMode"){
|
||||
isChange = isStateChange(device, name, value.toString())
|
||||
@@ -253,7 +251,6 @@ void setCoolingSetpoint(setpoint) {
|
||||
def maxCoolingSetpoint = device.currentValue("maxCoolingSetpoint")
|
||||
def minCoolingSetpoint = device.currentValue("minCoolingSetpoint")
|
||||
|
||||
|
||||
if (coolingSetpoint > maxCoolingSetpoint) {
|
||||
coolingSetpoint = maxCoolingSetpoint
|
||||
} else if (coolingSetpoint < minCoolingSetpoint) {
|
||||
@@ -283,7 +280,6 @@ void setCoolingSetpoint(setpoint) {
|
||||
}
|
||||
|
||||
void resumeProgram() {
|
||||
|
||||
log.debug "resumeProgram() is called"
|
||||
sendEvent("name":"thermostatStatus", "value":"resuming schedule", "description":statusText, displayed: false)
|
||||
def deviceId = device.deviceNetworkId.split(/\./).last()
|
||||
@@ -354,7 +350,6 @@ def switchFanMode() {
|
||||
}
|
||||
|
||||
def switchToFanMode(nextMode) {
|
||||
|
||||
log.debug "switching to fan mode: $nextMode"
|
||||
def returnCommand
|
||||
|
||||
@@ -520,63 +515,56 @@ def fanAuto() {
|
||||
}
|
||||
|
||||
def generateSetpointEvent() {
|
||||
|
||||
log.debug "Generate SetPoint Event"
|
||||
|
||||
def mode = device.currentValue("thermostatMode")
|
||||
log.debug "Current Mode = ${mode}"
|
||||
|
||||
def heatingSetpoint = device.currentValue("heatingSetpoint")
|
||||
log.debug "Heating Setpoint = ${heatingSetpoint}"
|
||||
|
||||
def coolingSetpoint = device.currentValue("coolingSetpoint")
|
||||
log.debug "Cooling Setpoint = ${coolingSetpoint}"
|
||||
|
||||
def maxHeatingSetpoint = device.currentValue("maxHeatingSetpoint")
|
||||
def maxCoolingSetpoint = device.currentValue("maxCoolingSetpoint")
|
||||
def minHeatingSetpoint = device.currentValue("minHeatingSetpoint")
|
||||
def minCoolingSetpoint = device.currentValue("minCoolingSetpoint")
|
||||
|
||||
if(location.temperatureScale == "C")
|
||||
{
|
||||
maxHeatingSetpoint = roundC(maxHeatingSetpoint)
|
||||
maxCoolingSetpoint = roundC(maxCoolingSetpoint)
|
||||
minHeatingSetpoint = roundC(minHeatingSetpoint)
|
||||
minCoolingSetpoint = roundC(minCoolingSetpoint)
|
||||
heatingSetpoint = roundC(heatingSetpoint)
|
||||
coolingSetpoint = roundC(coolingSetpoint)
|
||||
if(location.temperatureScale == "C") {
|
||||
maxHeatingSetpoint = maxHeatingSetpoint > 40 ? roundC(convertFtoC(maxHeatingSetpoint)) : roundC(maxHeatingSetpoint)
|
||||
maxCoolingSetpoint = maxCoolingSetpoint > 40 ? roundC(convertFtoC(maxCoolingSetpoint)) : roundC(maxCoolingSetpoint)
|
||||
minHeatingSetpoint = minHeatingSetpoint > 40 ? roundC(convertFtoC(minHeatingSetpoint)) : roundC(minHeatingSetpoint)
|
||||
minCoolingSetpoint = minCoolingSetpoint > 40 ? roundC(convertFtoC(minCoolingSetpoint)) : roundC(minCoolingSetpoint)
|
||||
heatingSetpoint = heatingSetpoint > 40 ? roundC(convertFtoC(heatingSetpoint)) : roundC(heatingSetpoint)
|
||||
coolingSetpoint = coolingSetpoint > 40 ? roundC(convertFtoC(coolingSetpoint)) : roundC(coolingSetpoint)
|
||||
} else {
|
||||
maxHeatingSetpoint = maxHeatingSetpoint < 40 ? roundC(convertCtoF(maxHeatingSetpoint)) : maxHeatingSetpoint
|
||||
maxCoolingSetpoint = maxCoolingSetpoint < 40 ? roundC(convertCtoF(maxCoolingSetpoint)) : maxCoolingSetpoint
|
||||
minHeatingSetpoint = minHeatingSetpoint < 40 ? roundC(convertCtoF(minHeatingSetpoint)) : minHeatingSetpoint
|
||||
minCoolingSetpoint = minCoolingSetpoint < 40 ? roundC(convertCtoF(minCoolingSetpoint)) : minCoolingSetpoint
|
||||
heatingSetpoint = heatingSetpoint < 40 ? roundC(convertCtoF(heatingSetpoint)) : heatingSetpoint
|
||||
coolingSetpoint = coolingSetpoint < 40 ? roundC(convertCtoF(coolingSetpoint)) : coolingSetpoint
|
||||
}
|
||||
|
||||
log.debug "Current Mode = ${mode}"
|
||||
log.debug "Heating Setpoint = ${heatingSetpoint}"
|
||||
log.debug "Cooling Setpoint = ${coolingSetpoint}"
|
||||
|
||||
sendEvent("name":"maxHeatingSetpoint", "value":maxHeatingSetpoint, "unit":location.temperatureScale)
|
||||
sendEvent("name":"maxCoolingSetpoint", "value":maxCoolingSetpoint, "unit":location.temperatureScale)
|
||||
sendEvent("name":"minHeatingSetpoint", "value":minHeatingSetpoint, "unit":location.temperatureScale)
|
||||
sendEvent("name":"minCoolingSetpoint", "value":minCoolingSetpoint, "unit":location.temperatureScale)
|
||||
|
||||
sendEvent("name":"heatingSetpoint", "value":heatingSetpoint, "unit":location.temperatureScale)
|
||||
sendEvent("name":"coolingSetpoint", "value":coolingSetpoint, "unit":location.temperatureScale)
|
||||
|
||||
if (mode == "heat") {
|
||||
|
||||
sendEvent("name":"thermostatSetpoint", "value":heatingSetpoint, "unit":location.temperatureScale)
|
||||
|
||||
}
|
||||
else if (mode == "cool") {
|
||||
|
||||
sendEvent("name":"thermostatSetpoint", "value":coolingSetpoint, "unit":location.temperatureScale)
|
||||
|
||||
} else if (mode == "auto") {
|
||||
|
||||
sendEvent("name":"thermostatSetpoint", "value":"Auto")
|
||||
|
||||
} else if (mode == "off") {
|
||||
|
||||
sendEvent("name":"thermostatSetpoint", "value":"Off")
|
||||
|
||||
} else if (mode == "auxHeatOnly") {
|
||||
|
||||
sendEvent("name":"thermostatSetpoint", "value":heatingSetpoint, "unit":location.temperatureScale)
|
||||
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
void raiseSetpoint() {
|
||||
@@ -585,21 +573,31 @@ void raiseSetpoint() {
|
||||
def maxHeatingSetpoint = device.currentValue("maxHeatingSetpoint")
|
||||
def maxCoolingSetpoint = device.currentValue("maxCoolingSetpoint")
|
||||
|
||||
|
||||
if (mode == "off" || mode == "auto") {
|
||||
log.warn "this mode: $mode does not allow raiseSetpoint"
|
||||
} else {
|
||||
|
||||
def heatingSetpoint = device.currentValue("heatingSetpoint")
|
||||
def coolingSetpoint = device.currentValue("coolingSetpoint")
|
||||
def thermostatSetpoint = device.currentValue("thermostatSetpoint")
|
||||
|
||||
if (location.temperatureScale == "C") {
|
||||
maxHeatingSetpoint = maxHeatingSetpoint > 40 ? convertFtoC(maxHeatingSetpoint) : maxHeatingSetpoint
|
||||
maxCoolingSetpoint = maxCoolingSetpoint > 40 ? convertFtoC(maxCoolingSetpoint) : maxCoolingSetpoint
|
||||
heatingSetpoint = heatingSetpoint > 40 ? convertFtoC(heatingSetpoint) : heatingSetpoint
|
||||
coolingSetpoint = coolingSetpoint > 40 ? convertFtoC(coolingSetpoint) : coolingSetpoint
|
||||
thermostatSetpoint = thermostatSetpoint > 40 ? convertFtoC(thermostatSetpoint) : thermostatSetpoint
|
||||
} else {
|
||||
maxHeatingSetpoint = maxHeatingSetpoint < 40 ? convertCtoF(maxHeatingSetpoint) : maxHeatingSetpoint
|
||||
maxCoolingSetpoint = maxCoolingSetpoint < 40 ? convertCtoF(maxCoolingSetpoint) : maxCoolingSetpoint
|
||||
heatingSetpoint = heatingSetpoint < 40 ? convertCtoF(heatingSetpoint) : heatingSetpoint
|
||||
coolingSetpoint = coolingSetpoint < 40 ? convertCtoF(coolingSetpoint) : coolingSetpoint
|
||||
thermostatSetpoint = thermostatSetpoint < 40 ? convertCtoF(thermostatSetpoint) : thermostatSetpoint
|
||||
}
|
||||
|
||||
log.debug "raiseSetpoint() mode = ${mode}, heatingSetpoint: ${heatingSetpoint}, coolingSetpoint:${coolingSetpoint}, thermostatSetpoint:${thermostatSetpoint}"
|
||||
|
||||
if (device.latestState('thermostatSetpoint')) {
|
||||
targetvalue = device.latestState('thermostatSetpoint').value
|
||||
targetvalue = location.temperatureScale == "F"? targetvalue.toInteger() : targetvalue.toDouble()
|
||||
} else {
|
||||
targetvalue = 0
|
||||
}
|
||||
targetvalue = thermostatSetpoint ? thermostatSetpoint : 0
|
||||
targetvalue = location.temperatureScale == "F"? targetvalue + 1 : targetvalue + 0.5
|
||||
|
||||
if ((mode == "heat" || mode == "auxHeatOnly") && targetvalue > maxHeatingSetpoint) {
|
||||
@@ -622,20 +620,29 @@ void lowerSetpoint() {
|
||||
def minHeatingSetpoint = device.currentValue("minHeatingSetpoint")
|
||||
def minCoolingSetpoint = device.currentValue("minCoolingSetpoint")
|
||||
|
||||
|
||||
if (mode == "off" || mode == "auto") {
|
||||
log.warn "this mode: $mode does not allow lowerSetpoint"
|
||||
} else {
|
||||
def heatingSetpoint = device.currentValue("heatingSetpoint")
|
||||
def coolingSetpoint = device.currentValue("coolingSetpoint")
|
||||
def thermostatSetpoint = device.currentValue("thermostatSetpoint")
|
||||
log.debug "lowerSetpoint() mode = ${mode}, heatingSetpoint: ${heatingSetpoint}, coolingSetpoint:${coolingSetpoint}, thermostatSetpoint:${thermostatSetpoint}"
|
||||
if (device.latestState('thermostatSetpoint')) {
|
||||
targetvalue = device.latestState('thermostatSetpoint').value
|
||||
targetvalue = location.temperatureScale == "F"? targetvalue.toInteger() : targetvalue.toDouble()
|
||||
|
||||
if (location.temperatureScale == "C") {
|
||||
minHeatingSetpoint = minHeatingSetpoint > 40 ? convertFtoC(minHeatingSetpoint) : minHeatingSetpoint
|
||||
minCoolingSetpoint = minCoolingSetpoint > 40 ? convertFtoC(minCoolingSetpoint) : minCoolingSetpoint
|
||||
heatingSetpoint = heatingSetpoint > 40 ? convertFtoC(heatingSetpoint) : heatingSetpoint
|
||||
coolingSetpoint = coolingSetpoint > 40 ? convertFtoC(coolingSetpoint) : coolingSetpoint
|
||||
thermostatSetpoint = thermostatSetpoint > 40 ? convertFtoC(thermostatSetpoint) : thermostatSetpoint
|
||||
} else {
|
||||
targetvalue = 0
|
||||
minHeatingSetpoint = minHeatingSetpoint < 40 ? convertCtoF(minHeatingSetpoint) : minHeatingSetpoint
|
||||
minCoolingSetpoint = minCoolingSetpoint < 40 ? convertCtoF(minCoolingSetpoint) : minCoolingSetpoint
|
||||
heatingSetpoint = heatingSetpoint < 40 ? convertCtoF(heatingSetpoint) : heatingSetpoint
|
||||
coolingSetpoint = coolingSetpoint < 40 ? convertCtoF(coolingSetpoint) : coolingSetpoint
|
||||
thermostatSetpoint = thermostatSetpoint < 40 ? convertCtoF(thermostatSetpoint) : thermostatSetpoint
|
||||
}
|
||||
log.debug "lowerSetpoint() mode = ${mode}, heatingSetpoint: ${heatingSetpoint}, coolingSetpoint:${coolingSetpoint}, thermostatSetpoint:${thermostatSetpoint}"
|
||||
|
||||
targetvalue = thermostatSetpoint ? thermostatSetpoint : 0
|
||||
targetvalue = location.temperatureScale == "F"? targetvalue - 1 : targetvalue - 0.5
|
||||
|
||||
if ((mode == "heat" || mode == "auxHeatOnly") && targetvalue < minHeatingSetpoint) {
|
||||
@@ -653,7 +660,6 @@ void lowerSetpoint() {
|
||||
|
||||
//called by raiseSetpoint() and lowerSetpoint()
|
||||
void alterSetpoint(temp) {
|
||||
|
||||
def mode = device.currentValue("thermostatMode")
|
||||
|
||||
if (mode == "off" || mode == "auto") {
|
||||
@@ -666,6 +672,18 @@ void alterSetpoint(temp) {
|
||||
def targetHeatingSetpoint
|
||||
def targetCoolingSetpoint
|
||||
|
||||
def temperatureScaleHasChanged = false
|
||||
|
||||
if (location.temperatureScale == "C") {
|
||||
if ( heatingSetpoint > 40.0 || coolingSetpoint > 40.0 ) {
|
||||
temperatureScaleHasChanged = true
|
||||
}
|
||||
} else {
|
||||
if ( heatingSetpoint < 40.0 || coolingSetpoint < 40.0 ) {
|
||||
temperatureScaleHasChanged = true
|
||||
}
|
||||
}
|
||||
|
||||
//step1: check thermostatMode, enforce limits before sending request to cloud
|
||||
if (mode == "heat" || mode == "auxHeatOnly"){
|
||||
if (temp.value > coolingSetpoint){
|
||||
@@ -707,17 +725,18 @@ void alterSetpoint(temp) {
|
||||
sendEvent("name": "thermostatSetpoint", "value": coolingSetpoint.toString(), displayed: false)
|
||||
}
|
||||
}
|
||||
|
||||
if ( temperatureScaleHasChanged )
|
||||
generateSetpointEvent()
|
||||
generateStatusEvent()
|
||||
}
|
||||
}
|
||||
|
||||
def generateStatusEvent() {
|
||||
|
||||
def mode = device.currentValue("thermostatMode")
|
||||
def heatingSetpoint = device.currentValue("heatingSetpoint")
|
||||
def coolingSetpoint = device.currentValue("coolingSetpoint")
|
||||
def temperature = device.currentValue("temperature")
|
||||
|
||||
def statusText
|
||||
|
||||
log.debug "Generate Status Event for Mode = ${mode}"
|
||||
@@ -727,36 +746,25 @@ def generateStatusEvent() {
|
||||
log.debug "HVAC Mode = ${mode}"
|
||||
|
||||
if (mode == "heat") {
|
||||
|
||||
if (temperature >= heatingSetpoint)
|
||||
statusText = "Right Now: Idle"
|
||||
else
|
||||
statusText = "Heating to ${heatingSetpoint} ${location.temperatureScale}"
|
||||
|
||||
} else if (mode == "cool") {
|
||||
|
||||
if (temperature <= coolingSetpoint)
|
||||
statusText = "Right Now: Idle"
|
||||
else
|
||||
statusText = "Cooling to ${coolingSetpoint} ${location.temperatureScale}"
|
||||
|
||||
} else if (mode == "auto") {
|
||||
|
||||
statusText = "Right Now: Auto"
|
||||
|
||||
} else if (mode == "off") {
|
||||
|
||||
statusText = "Right Now: Off"
|
||||
|
||||
} else if (mode == "auxHeatOnly") {
|
||||
|
||||
statusText = "Emergency Heat"
|
||||
|
||||
} else {
|
||||
|
||||
statusText = "?"
|
||||
|
||||
}
|
||||
|
||||
log.debug "Generate Status Event = ${statusText}"
|
||||
sendEvent("name":"thermostatStatus", "value":statusText, "description":statusText, displayed: true)
|
||||
}
|
||||
@@ -770,7 +778,7 @@ def roundC (tempC) {
|
||||
}
|
||||
|
||||
def convertFtoC (tempF) {
|
||||
return String.format("%.1f", (Math.round(((tempF - 32)*(5/9)) * 2))/2)
|
||||
return ((Math.round(((tempF - 32)*(5/9)) * 2))/2).toDouble()
|
||||
}
|
||||
|
||||
def convertCtoF (tempC) {
|
||||
|
||||
Reference in New Issue