Added health-check for Z-wave Water Valve

This commit is contained in:
Parijat Das
2017-03-23 21:12:09 -07:00
parent fbdaeea9ae
commit 12bb6c0492
3 changed files with 56 additions and 0 deletions

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,38 @@
# Z-Wave Water Valve
Cloud Execution
Works with:
* [Leak Intelligence Leak Gopher Water Shutoff Valve](https://www.smartthings.com/works-with-smartthings/other/leak-intelligence-leak-gopher-water-shutoff-valve)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Troubleshooting](#Troubleshooting)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Health Check** - indicates ability to get device health notifications
* **Valve** - allows for the control of a valve device
* **Polling** - represents that poll() can be implemented for the device
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - detects sensor events
## Device Health
SmartThings platform will ping the device after `checkInterval` seconds of inactivity in last attempt to reach the device before marking it `OFFLINE`
* __32min__ checkInterval
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [Leak Intelligence Leak Gopher Water Shutoff Valve Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/209631423-Leak-Gopher-Z-Wave-Valve-Control)

View File

@@ -14,12 +14,14 @@
metadata {
definition (name: "Z-Wave Water Valve", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Health Check"
capability "Valve"
capability "Polling"
capability "Refresh"
capability "Sensor"
fingerprint deviceId: "0x1006", inClusters: "0x25"
fingerprint mfr:"0173", prod:"0003", model:"0002", deviceJoinName: "Leak Intelligence Leak Gopher Water Shutoff Valve"
}
// simulator metadata
@@ -53,7 +55,14 @@ metadata {
}
def installed() {
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
def updated() {
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
response(refresh())
}
@@ -114,6 +123,13 @@ def poll() {
zwave.switchBinaryV1.switchBinaryGet().format()
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
refresh()
}
def refresh() {
log.debug "refresh() is called"
def commands = [zwave.switchBinaryV1.switchBinaryGet().format()]