mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-08 05:31:56 +00:00
Implemented of Health Check for Aeon Siren.
This commit is contained in:
2
devicetypes/smartthings/aeon-siren.src/.st-ignore
Normal file
2
devicetypes/smartthings/aeon-siren.src/.st-ignore
Normal file
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
37
devicetypes/smartthings/aeon-siren.src/README.md
Normal file
37
devicetypes/smartthings/aeon-siren.src/README.md
Normal file
@@ -0,0 +1,37 @@
|
||||
# Aeon Siren
|
||||
|
||||
Cloud Execution
|
||||
|
||||
Works with:
|
||||
|
||||
* [Aeon Labs Siren (Gen 5)](https://www.smartthings.com/works-with-smartthings/aeon-labs/aeon-labs-siren-gen-5)
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Alarm** - allows for interacting with devices that serve as alarms
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
|
||||
## Device Health
|
||||
|
||||
Aeon Labs Siren (Gen 5) is polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
* __32min__ checkInterval
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [Aeon Labs Siren (Gen 5) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/204555240-Aeon-Labs-Siren-Gen-5-)
|
||||
@@ -20,10 +20,11 @@ metadata {
|
||||
capability "Actuator"
|
||||
capability "Alarm"
|
||||
capability "Switch"
|
||||
capability "Health Check"
|
||||
|
||||
command "test"
|
||||
|
||||
fingerprint deviceId: "0x1005", inClusters: "0x5E,0x98"
|
||||
fingerprint deviceId: "0x1005", inClusters: "0x5E,0x98", deviceJoinName: "Aeon Labs Siren (Gen 5)"
|
||||
}
|
||||
|
||||
simulator {
|
||||
@@ -58,6 +59,9 @@ metadata {
|
||||
}
|
||||
|
||||
def updated() {
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
if(!state.sound) state.sound = 1
|
||||
if(!state.volume) state.volume = 3
|
||||
|
||||
@@ -148,3 +152,10 @@ def test() {
|
||||
private secure(physicalgraph.zwave.Command cmd) {
|
||||
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
secure(zwave.basicV1.basicGet())
|
||||
}
|
||||
Reference in New Issue
Block a user