@@ -403,39 +403,21 @@ def refresh() {
|
||||
|
||||
if (device.getDataValue("manufacturer") == "SmartThings") {
|
||||
log.debug "Refreshing Values for manufacturer: SmartThings "
|
||||
refreshCmds = refreshCmds + [
|
||||
/* These values of Motion Threshold Multiplier(01) and Motion Threshold (7602)
|
||||
seem to be giving pretty accurate results for the XYZ co-ordinates for this manufacturer.
|
||||
Separating these out in a separate if-else because I do not want to touch Centralite part
|
||||
as of now.
|
||||
*/
|
||||
|
||||
"zcl mfg-code ${manufacturerCode}", "delay 200",
|
||||
"zcl global write 0xFC02 0 0x20 {01}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 1", "delay 400",
|
||||
|
||||
"zcl mfg-code ${manufacturerCode}", "delay 200",
|
||||
"zcl global write 0xFC02 2 0x21 {7602}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 1", "delay 400",
|
||||
]
|
||||
/* These values of Motion Threshold Multiplier(0x01) and Motion Threshold (0x0276)
|
||||
seem to be giving pretty accurate results for the XYZ co-ordinates for this manufacturer.
|
||||
Separating these out in a separate if-else because I do not want to touch Centralite part
|
||||
as of now.
|
||||
*/
|
||||
refreshCmds += zigbee.writeAttribute(0xFC02, 0x0000, 0x20, 0x01, [mfgCode: manufacturerCode])
|
||||
refreshCmds += zigbee.writeAttribute(0xFC02, 0x0002, 0x21, 0x0276, [mfgCode: manufacturerCode])
|
||||
} else {
|
||||
refreshCmds = refreshCmds + [
|
||||
/* sensitivity - default value (8) */
|
||||
"zcl mfg-code ${manufacturerCode}", "delay 200",
|
||||
"zcl global write 0xFC02 0 0x20 {02}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 1", "delay 400",
|
||||
]
|
||||
refreshCmds += zigbee.writeAttribute(0xFC02, 0x0000, 0x20, 0x02, [mfgCode: manufacturerCode])
|
||||
}
|
||||
|
||||
//Common refresh commands
|
||||
refreshCmds = refreshCmds + [
|
||||
"st rattr 0x${device.deviceNetworkId} 1 0x402 0", "delay 200",
|
||||
"st rattr 0x${device.deviceNetworkId} 1 1 0x20", "delay 200",
|
||||
|
||||
"zcl mfg-code ${manufacturerCode}", "delay 200",
|
||||
"zcl global read 0xFC02 0x0010",
|
||||
"send 0x${device.deviceNetworkId} 1 1","delay 400"
|
||||
]
|
||||
refreshCmds += zigbee.readAttribute(0x0402, 0x0000) +
|
||||
zigbee.readAttribute(0x0001, 0x0020) +
|
||||
zigbee.readAttribute(0xFC02, 0x0010, [mfgCode: manufacturerCode])
|
||||
|
||||
return refreshCmds + enrollResponse()
|
||||
}
|
||||
@@ -443,38 +425,15 @@ def refresh() {
|
||||
def configure() {
|
||||
sendEvent(name: "checkInterval", value: 7200, displayed: false)
|
||||
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting"
|
||||
|
||||
def configCmds = [
|
||||
"zcl global write 0x500 0x10 0xf0 {${zigbeeEui}}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
|
||||
"zdo bind 0x${device.deviceNetworkId} ${endpointId} 1 1 {${device.zigbeeId}} {}", "delay 200",
|
||||
"zcl global send-me-a-report 1 0x20 0x20 30 21600 {01}", "delay 200", //checkin time 6 hrs
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
|
||||
"zdo bind 0x${device.deviceNetworkId} ${endpointId} 1 0x402 {${device.zigbeeId}} {}", "delay 200",
|
||||
"zcl global send-me-a-report 0x402 0 0x29 30 3600 {6400}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
|
||||
"zdo bind 0x${device.deviceNetworkId} ${endpointId} 1 0xFC02 {${device.zigbeeId}} {}", "delay 200",
|
||||
"zcl mfg-code ${manufacturerCode}", "delay 200",
|
||||
"zcl global send-me-a-report 0xFC02 0x0010 0x18 10 3600 {01}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
|
||||
"zcl mfg-code ${manufacturerCode}", "delay 200",
|
||||
"zcl global send-me-a-report 0xFC02 0x0012 0x29 1 3600 {0100}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
|
||||
"zcl mfg-code ${manufacturerCode}", "delay 200",
|
||||
"zcl global send-me-a-report 0xFC02 0x0013 0x29 1 3600 {0100}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
|
||||
"zcl mfg-code ${manufacturerCode}", "delay 200",
|
||||
"zcl global send-me-a-report 0xFC02 0x0014 0x29 1 3600 {0100}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500"
|
||||
]
|
||||
def configCmds = enrollResponse() +
|
||||
zigbee.batteryConfig() +
|
||||
zigbee.temperatureConfig() +
|
||||
zigbee.configureReporting(0xFC02, 0x0010, 0x18, 10, 3600, 0x01, [mfgCode: manufacturerCode]) +
|
||||
zigbee.configureReporting(0xFC02, 0x0012, 0x29, 1, 3600, 0x0001, [mfgCode: manufacturerCode]) +
|
||||
zigbee.configureReporting(0xFC02, 0x0013, 0x29, 1, 3600, 0x0001, [mfgCode: manufacturerCode]) +
|
||||
zigbee.configureReporting(0xFC02, 0x0014, 0x29, 1, 3600, 0x0001, [mfgCode: manufacturerCode])
|
||||
|
||||
return configCmds + refresh()
|
||||
}
|
||||
|
||||