mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-09 13:21:53 +00:00
Added Health Check Implementation for following Z-wave switches:
1. Plug-In Smart Switch (GE 12719) 2. In-Wall Smart Outlet (GE 12721) 3. In-Wall Smart Switch (GE 12722) 4. In-Wall Smart Toggle Switch (GE 12727) Added Health Check Implementation for following Z-wave switches: 1. Plug-In Smart Switch (GE 12719) 2. In-Wall Smart Outlet (GE 12721) 3. In-Wall Smart Switch (GE 12722) 4. In-Wall Smart Toggle Switch (GE 12727)
This commit is contained in:
2
devicetypes/smartthings/zwave-switch.src/.st-ignore
Normal file
2
devicetypes/smartthings/zwave-switch.src/.st-ignore
Normal file
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
49
devicetypes/smartthings/zwave-switch.src/README.md
Normal file
49
devicetypes/smartthings/zwave-switch.src/README.md
Normal file
@@ -0,0 +1,49 @@
|
||||
# Z-Wave Switch
|
||||
|
||||
|
||||
Works with:
|
||||
|
||||
* [GE Z-Wave Plug-In Smart Switch (12719)](http://products.z-wavealliance.org/products/1193)
|
||||
* [GE Z-Wave In-Wall Smart Outlet (12721)](http://products.z-wavealliance.org/products/1195)
|
||||
* [GE Z-Wave In-Wall Smart Switch (12722)](http://products.z-wavealliance.org/products/1196)
|
||||
* [GE Z-Wave In-Wall Smart Toggle Switch (12727)](http://products.z-wavealliance.org/products/1200)
|
||||
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
* [Troubleshooting](#Troubleshooting)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Indicator** - gives you the ability to set the indicator LED light on a Z-Wave switch
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Polling** - represents that poll() can be implemented for the device
|
||||
* **Refresh** - _refresh()_ command for status updates
|
||||
* **Sensor** - detects sensor events
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
|
||||
## Device Health
|
||||
|
||||
Z-Wave Switches (Plug-In, In-Wall(Toggle Switch, Switch, Outlet)) are polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [General Z-Wave Dimmer/Switch Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200955890-Troubleshooting-GE-in-wall-switch-or-dimmer-won-t-respond-to-commands-or-automations-Z-Wave-)
|
||||
* [GE Z-Wave Plug-In Smart Switch (12719) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200903070-GE-Plug-In-Smart-Switch-GE-12719-Z-Wave)
|
||||
* [GE Z-Wave In-Wall Smart Outlet (12721) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200903020-GE-In-Wall-Smart-Outlet-GE-12721-Z-Wave)
|
||||
* [GE Z-Wave In-Wall Smart Switch (12722) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200902540-GE-In-Wall-Smart-Switch-GE-12722-Z-Wave)
|
||||
* [GE Z-Wave In-Wall Smart Toggle Switch (12727) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/207568933-GE-In-Wall-Smart-Toggle-Switch-GE-12727-Z-Wave)
|
||||
|
||||
|
||||
@@ -19,6 +19,7 @@ metadata {
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Health Check"
|
||||
|
||||
fingerprint mfr:"0063", prod:"4952", deviceJoinName: "Z-Wave Wall Switch"
|
||||
fingerprint mfr:"0063", prod:"5257", deviceJoinName: "Z-Wave Wall Switch"
|
||||
@@ -64,6 +65,8 @@ metadata {
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
switch (ledIndicator) {
|
||||
case "on":
|
||||
indicatorWhenOn()
|
||||
@@ -156,6 +159,13 @@ def poll() {
|
||||
])
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
**/
|
||||
def ping() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
delayBetween([
|
||||
zwave.switchBinaryV1.switchBinaryGet().format(),
|
||||
|
||||
Reference in New Issue
Block a user