Added health-check for Zigbee Lock

This commit is contained in:
Parijat Das
2017-03-29 18:15:20 -07:00
parent f05daf2f34
commit 515fab9fa4
3 changed files with 59 additions and 0 deletions

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,46 @@
# Zigbee Lock
Cloud Execution
Works with:
* [Yale Push Button Deadbolt (YRD210-HA)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-push-button-deadbolt-yrd210)
* [Yale Touchscreen Lever (YRL220-ZB)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-touchscreen-lever-yrl220)
* [Yale Touchscreen Deadbolt (YRD220-HA))](https://www.smartthings.com/works-with-smartthings/door-locks/yale-touchscreen-deadbolt-yrd220)
* [Yale Key Free Touchscreen Deadbolt (YRD240-HA)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-key-free-touchscreen-deadbolt-yrd240)
* [Yale Push Button Lever Lock (YRL210-HA)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-push-button-lever-lock-yrl210)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Battery](#battery-specification)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Lock** - allows for the control of a lock device
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - detects sensor events
* **Battery** - defines device uses a battery
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
* **Health Check** - indicates ability to get device health notifications
## Device Health
Yale Push Button Deadbolt (YRD210-HA) is a Zigbee device and checks in every 1 hour.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*60 + 2)mins = 122 mins.
* __122min__ checkInterval
## Battery Specification
Four AA 1.5V batteries are required.
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the sensor from SmartThings can be found in the following link:
* [Yale Locks Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205138400)

View File

@@ -24,6 +24,7 @@ import physicalgraph.zigbee.zcl.DataType
capability "Sensor"
capability "Battery"
capability "Configuration"
capability "Health Check"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0004,0005,0009,0020,0101,0402,0B05,FDBD", outClusters: "000A,0019", manufacturer: "Kwikset", model: "SMARTCODE_DEADBOLT_5", deviceJoinName: "Kwikset 5-Button Deadbolt"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0004,0005,0009,0020,0101,0402,0B05,FDBD", outClusters: "000A,0019", manufacturer: "Kwikset", model: "SMARTCODE_LEVER_5", deviceJoinName: "Kwikset 5-Button Lever"
@@ -83,6 +84,9 @@ def uninstalled() {
}
def configure() {
// Device-Watch allows 2 check-in misses from device + ping (plus 2 min lag time)
sendEvent(name: "checkInterval", value: 2 * 60 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
def cmds =
zigbee.configureReporting(CLUSTER_DOORLOCK, DOORLOCK_ATTR_LOCKSTATE,
DataType.ENUM8, 0, 3600, null) +
@@ -92,6 +96,13 @@ def configure() {
return refresh() + cmds // send refresh cmds as part of config
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
zigbee.readAttribute(CLUSTER_DOORLOCK, DOORLOCK_ATTR_LOCKSTATE)
}
def refresh() {
def cmds =