@@ -108,11 +108,20 @@ def updated(){
|
||||
}
|
||||
}
|
||||
|
||||
def getCommandClassVersions() {
|
||||
[
|
||||
0x20: 1, // Basic
|
||||
0x26: 1, // SwitchMultilevel
|
||||
0x56: 1, // Crc16Encap
|
||||
0x70: 1, // Configuration
|
||||
]
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def result = null
|
||||
if (description != "updated") {
|
||||
log.debug "parse() >> zwave.parse($description)"
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x26: 1, 0x70: 1])
|
||||
def cmd = zwave.parse(description, commandClassVersions)
|
||||
if (cmd) {
|
||||
result = zwaveEvent(cmd)
|
||||
}
|
||||
@@ -179,6 +188,16 @@ def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelS
|
||||
[createEvent(name:"switch", value:"on"), response(zwave.switchMultilevelV1.switchMultilevelGet().format())]
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
|
||||
def versions = commandClassVersions
|
||||
def version = versions[cmd.commandClass as Integer]
|
||||
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
|
||||
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
|
||||
if (encapsulatedCommand) {
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
// Handles all Z-Wave commands we aren't interested in
|
||||
[:]
|
||||
|
||||
@@ -88,11 +88,20 @@ def updated(){
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
|
||||
def getCommandClassVersions() {
|
||||
[
|
||||
0x20: 1, // Basic
|
||||
0x26: 1, // SwitchMultilevel
|
||||
0x56: 1, // Crc16Encap
|
||||
0x70: 1, // Configuration
|
||||
]
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def result = null
|
||||
if (description != "updated") {
|
||||
log.debug "parse() >> zwave.parse($description)"
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x26: 1, 0x70: 1])
|
||||
def cmd = zwave.parse(description, commandClassVersions)
|
||||
if (cmd) {
|
||||
result = zwaveEvent(cmd)
|
||||
}
|
||||
@@ -159,6 +168,16 @@ def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelS
|
||||
[createEvent(name:"switch", value:"on"), response(zwave.switchMultilevelV1.switchMultilevelGet().format())]
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
|
||||
def versions = commandClassVersions
|
||||
def version = versions[cmd.commandClass as Integer]
|
||||
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
|
||||
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
|
||||
if (encapsulatedCommand) {
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
// Handles all Z-Wave commands we aren't interested in
|
||||
[:]
|
||||
|
||||
@@ -85,11 +85,21 @@ metadata {
|
||||
details(["switch", "power", "energy", "levelSliderControl", "refresh", "reset"])
|
||||
}
|
||||
|
||||
def getCommandClassVersions() {
|
||||
[
|
||||
0x20: 1, // Basic
|
||||
0x26: 3, // SwitchMultilevel
|
||||
0x56: 1, // Crc16Encap
|
||||
0x70: 1, // Configuration
|
||||
0x32: 3, // Meter
|
||||
]
|
||||
}
|
||||
|
||||
// parse events into attributes
|
||||
def parse(String description) {
|
||||
def result = null
|
||||
if (description != "updated") {
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x26: 3, 0x70: 1, 0x32:3])
|
||||
def cmd = zwave.parse(description, commandClassVersions)
|
||||
if (cmd) {
|
||||
result = zwaveEvent(cmd)
|
||||
log.debug("'$description' parsed to $result")
|
||||
@@ -124,6 +134,21 @@ def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv3.SwitchMultilevelR
|
||||
dimmerEvents(cmd)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
|
||||
def versions = commandClassVersions
|
||||
def version = versions[cmd.commandClass as Integer]
|
||||
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
|
||||
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
|
||||
if (encapsulatedCommand) {
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
// Handles all Z-Wave commands we aren't interested in
|
||||
[:]
|
||||
}
|
||||
|
||||
def dimmerEvents(physicalgraph.zwave.Command cmd) {
|
||||
def result = []
|
||||
def value = (cmd.value ? "on" : "off")
|
||||
|
||||
@@ -89,10 +89,19 @@ def updated() {
|
||||
} catch (e) { log.debug e }
|
||||
}
|
||||
|
||||
def getCommandClassVersions() {
|
||||
[
|
||||
0x20: 1, // Basic
|
||||
0x32: 1, // SwitchMultilevel
|
||||
0x56: 1, // Crc16Encap
|
||||
0x72: 2, // ManufacturerSpecific
|
||||
]
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def result = null
|
||||
if(description == "updated") return
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x32: 1, 0x72: 2])
|
||||
def cmd = zwave.parse(description, commandClassVersions)
|
||||
if (cmd) {
|
||||
result = zwaveEvent(cmd)
|
||||
}
|
||||
@@ -157,6 +166,16 @@ def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerS
|
||||
result
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
|
||||
def versions = commandClassVersions
|
||||
def version = versions[cmd.commandClass as Integer]
|
||||
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
|
||||
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
|
||||
if (encapsulatedCommand) {
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
log.debug "$device.displayName: Unhandled: $cmd"
|
||||
[:]
|
||||
|
||||
@@ -71,9 +71,17 @@ def updated(){
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
|
||||
def getCommandClassVersions() {
|
||||
[
|
||||
0x20: 1, // Basic
|
||||
0x56: 1, // Crc16Encap
|
||||
0x70: 1, // Configuration
|
||||
]
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def result = null
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x70: 1])
|
||||
def cmd = zwave.parse(description, commandClassVersions)
|
||||
if (cmd) {
|
||||
result = createEvent(zwaveEvent(cmd))
|
||||
}
|
||||
@@ -120,6 +128,15 @@ def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerS
|
||||
createEvent([descriptionText: "$device.displayName MSR: $msr", isStateChange: false])
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
|
||||
def versions = commandClassVersions
|
||||
def version = versions[cmd.commandClass as Integer]
|
||||
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
|
||||
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
|
||||
if (encapsulatedCommand) {
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
// Handles all Z-Wave commands we aren't interested in
|
||||
|
||||
@@ -89,9 +89,17 @@ def updated(){
|
||||
}
|
||||
}
|
||||
|
||||
def getCommandClassVersions() {
|
||||
[
|
||||
0x20: 1, // Basic
|
||||
0x56: 1, // Crc16Encap
|
||||
0x70: 1, // Configuration
|
||||
]
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def result = null
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x70: 1])
|
||||
def cmd = zwave.parse(description, commandClassVersions)
|
||||
if (cmd) {
|
||||
result = createEvent(zwaveEvent(cmd))
|
||||
}
|
||||
@@ -138,6 +146,16 @@ def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerS
|
||||
createEvent([descriptionText: "$device.displayName MSR: $msr", isStateChange: false])
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
|
||||
def versions = commandClassVersions
|
||||
def version = versions[cmd.commandClass as Integer]
|
||||
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
|
||||
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
|
||||
if (encapsulatedCommand) {
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
// Handles all Z-Wave commands we aren't interested in
|
||||
|
||||
Reference in New Issue