mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-08 05:31:56 +00:00
ICP-1097 Fix Sengled Classic default level on pairing
Code brought oever from @varzac commit 8bcbe7b924
Original commit message:
> Fix sengled use of FF for max level
> This works around the fact that sengled element touches can get back
> into a state of reporting an invalid value (of FF) if the physical
> button on the bulb is used to cycle back to the 100% state. Here we
> interpret FF as FE for sengled and then issue a move to level command to
> put it in a state where it will report FE until the level is changed
> again.
>
> This resolves: https://smartthings.atlassian.net/browse/DVCSMP-2597
While the Classic does not have a physical button, since it does represent 100% as FF we want to always catch this.
This commit is contained in:
@@ -66,22 +66,29 @@ def parse(String description) {
|
||||
else {
|
||||
sendEvent(event)
|
||||
}
|
||||
}
|
||||
else {
|
||||
def cluster = zigbee.parse(description)
|
||||
|
||||
if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07) {
|
||||
if (cluster.data[0] == 0x00) {
|
||||
} else {
|
||||
def descMap = zigbee.parseDescriptionAsMap(description)
|
||||
if (descMap && descMap.clusterInt == 0x0006 && descMap.commandInt == 0x07) {
|
||||
if (descMap.data[0] == "00") {
|
||||
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
|
||||
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
else {
|
||||
} else {
|
||||
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
|
||||
}
|
||||
}
|
||||
else {
|
||||
} else if (device.getDataValue("manufacturer") == "sengled" && descMap && descMap.clusterInt == 0x0008 && descMap.attrInt == 0x0000) {
|
||||
// This is being done because the sengled element touch/classic incorrectly uses the value 0xFF for the max level.
|
||||
// Per the ZCL spec for the UINT8 data type 0xFF is an invalid value, and 0xFE should be the max. Here we
|
||||
// manually handle the invalid attribute value since it will be ignored by getEvent as an invalid value.
|
||||
// We also set the level of the bulb to 0xFE so future level reports will be 0xFE until it is changed by
|
||||
// something else.
|
||||
if (descMap.value.toUpperCase() == "FF") {
|
||||
descMap.value = "FE"
|
||||
}
|
||||
sendHubCommand(zigbee.command(zigbee.LEVEL_CONTROL_CLUSTER, 0x00, "FE0000").collect { new physicalgraph.device.HubAction(it) }, 0)
|
||||
sendEvent(zigbee.getEventFromAttrData(descMap.clusterInt, descMap.attrInt, descMap.encoding, descMap.value))
|
||||
} else {
|
||||
log.warn "DID NOT PARSE MESSAGE for description : $description"
|
||||
log.debug "${cluster}"
|
||||
log.debug "${descMap}"
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue