DVCSMP-668

- Show batteryStatus tile insteady of battery tile to be able to display both when sensor is USB powered or battery powered
- Remove background for illuminance. This can be added when we have best practice of showing colors for lux.
- Instead of using powerSupply:failed, configurationGet cmd is sent and then the configure() is triggered by configurationReport to determine powerSupply (USB Cable/Battery)
- Instead of querying battery level on wake up, battery report is put in association group 2 that is configured to report every 6 hours by default
- Update configure() to  send both unsecure and secure configuration commands when sensor is joined normally or securely
This commit is contained in:
Warodom Khamphanchai
2015-10-21 15:33:51 -07:00
parent ef21fd4257
commit 794ff6b68a

View File

@@ -24,6 +24,7 @@ metadata {
capability "Battery"
attribute "tamper", "enum", ["detected", "clear"]
attribute "batteryStatus", "string"
attribute "powerSupply", "enum", ["USB Cable", "Battery"]
fingerprint deviceId: "0x2101", inClusters: "0x5E,0x86,0x72,0x59,0x85,0x73,0x71,0x84,0x80,0x30,0x31,0x70,0x7A", outClusters: "0x5A"
@@ -101,17 +102,7 @@ metadata {
}
valueTile("illuminance", "device.illuminance", inactiveLabel: false, width: 2, height: 2) {
state "illuminance", label:'${currentValue} ${unit}', unit:"lux",
backgroundColors:[
[value: 0, color: "#000000"],
[value: 1, color: "#060053"],
[value: 3, color: "#3E3900"],
[value: 12, color: "#8E8400"],
[value: 24, color: "#C5C08B"],
[value: 36, color: "#DAD7B6"],
[value: 128, color: "#F3F2E9"],
[value: 1000, color: "#FFFFFF"]
]
state "illuminance", label:'${currentValue} ${unit}', unit:"lux"
}
valueTile("ultravioletIndex", "device.ultravioletIndex", inactiveLabel: false, width: 2, height: 2) {
@@ -122,18 +113,21 @@ metadata {
state "battery", label:'${currentValue}% battery', unit:""
}
valueTile("batteryStatus", "device.batteryStatus", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "batteryStatus", label:'${currentValue}', unit:""
}
valueTile("powerSupply", "device.powerSupply", height: 2, width: 2, decoration: "flat") {
state "powerSupply", label:'${currentValue} powered', backgroundColor:"#ffffff"
}
main(["motion", "temperature", "humidity", "illuminance", "ultravioletIndex"])
details(["motion", "temperature", "humidity", "illuminance", "ultravioletIndex", "battery", "powerSupply"])
details(["motion", "temperature", "humidity", "illuminance", "ultravioletIndex", "batteryStatus"])
}
}
def updated() {
log.debug "Updated with settings: ${settings}"
log.debug "${device.displayName} is now ${device.latestValue("powerSupply")}"
if (device.latestValue("powerSupply") == "USB Cable") { //case1: USB powered
@@ -142,8 +136,10 @@ def updated() {
// setConfigured("false") is used by WakeUpNotification
setConfigured("false") //wait until the next time device wakeup to send configure command after user change preference
} else { //case3: power source is not identified, ask user to properly pair the sensor again
sendEvent( name: "powerSupply", value: "failed", isStateChange: true, displayed: true,
descriptionText: "This sensor failed to update it's power supply source. Unplug and plug-in the USB cable again or reinsert batteries to the sensor")
log.warn "power source is not identified, check it sensor is powered by USB, if so > configure()"
def request = []
request << zwave.configurationV1.configurationGet(parameterNumber: 101)
response(commands(request))
}
}
@@ -173,12 +169,6 @@ def zwaveEvent(physicalgraph.zwave.commands.wakeupv1.WakeUpNotification cmd) {
log.debug("late configure")
result << response(configure())
} else {
//Only ask for battery if we haven't had a BatteryReport in a while
if (!state.lastbatt || (new Date().time) - state.lastbatt > 24*60*60*1000) {
log.debug("Device has been configured sending >> batteryGet()")
cmds << zwave.securityV1.securityMessageEncapsulation().encapsulate(zwave.batteryV1.batteryGet()).format()
cmds << "delay 1200"
}
log.debug("Device has been configured sending >> wakeUpNoMoreInformation()")
cmds << zwave.wakeUpV1.wakeUpNoMoreInformation().format()
result << response(cmds)
@@ -221,6 +211,7 @@ def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerS
}
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def result = []
def map = [ name: "battery", unit: "%" ]
if (cmd.batteryLevel == 0xFF) {
map.value = 1
@@ -230,7 +221,11 @@ def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
map.value = cmd.batteryLevel
}
state.lastbatt = now()
createEvent(map)
result << createEvent(map)
if (device.latestValue("powerSupply") != "USB Cable"){
result << createEvent(name: "batteryStatus", value: "${map.value} % battery", displayed: false)
}
result
}
def zwaveEvent(physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd){
@@ -305,17 +300,23 @@ def zwaveEvent(physicalgraph.zwave.commands.notificationv3.NotificationReport cm
}
def zwaveEvent(physicalgraph.zwave.commands.configurationv2.ConfigurationReport cmd) {
log.debug "ConfigurationReport: $cmd"
def result = []
def value
if (cmd.configurationValue[0] == 0) {
if (cmd.parameterNumber == 9 && cmd.configurationValue[0] == 0) {
value = "USB Cable"
if (!isConfigured()) {
log.debug("ConfigurationReport: configuring device")
result << response(configure())
}
result << createEvent(name: "batteryStatus", value: value, displayed: false)
result << createEvent(name: "powerSupply", value: value, displayed: false)
}else if (cmd.parameterNumber == 9 && cmd.configurationValue[0] == 1) {
value = "Battery"
result << createEvent(name: "powerSupply", value: value, displayed: false)
} else if (cmd.parameterNumber == 101){
result << response(configure())
}
if (cmd.configurationValue[0] == 1) {value = "Battery"}
result << createEvent(name: "powerSupply", value: value, displayed: false)
result
}
@@ -326,45 +327,49 @@ def zwaveEvent(physicalgraph.zwave.Command cmd) {
def configure() {
// This sensor joins as a secure device if you double-click the button to include it
if (!state.sec) {
log.debug "${device.displayName} not sending configure until secure"
return []
} else {
log.debug "${device.displayName} is configuring its settings"
def request = []
log.debug "${device.displayName} is configuring its settings"
def request = []
//1. automatic report flags
// param 101 -103 [4 bytes] 128: light sensor, 64 humidity, 32 temperature sensor, 2 ultraviolet sensor, 1 battery sensor -> send command 227 to get all reports
request << zwave.configurationV1.configurationSet(parameterNumber: 101, size: 4, scaledConfigurationValue: 227)
//1. set association groups for hub
request << zwave.associationV1.associationSet(groupingIdentifier:1, nodeId:zwaveHubNodeId)
//2. no-motion report x seconds after motion stops (default 20 secs)
request << zwave.configurationV1.configurationSet(parameterNumber: 3, size: 2, scaledConfigurationValue: timeOptionValueMap[motionDelayTime] ?: 20)
request << zwave.associationV1.associationSet(groupingIdentifier:2, nodeId:zwaveHubNodeId)
//3. motionSensitivity 3 levels: 64-normal (default), 127-maximum, 0-minimum
request << zwave.configurationV1.configurationSet(parameterNumber: 6, size: 1,
scaledConfigurationValue:
motionSensitivity == "normal" ? 64 :
motionSensitivity == "maximum" ? 127 :
motionSensitivity == "minimum" ? 0 : 64)
//2. automatic report flags
// param 101 -103 [4 bytes] 128: light sensor, 64 humidity, 32 temperature sensor, 2 ultraviolet sensor, 1 battery sensor -> send command 227 to get all reports
request << zwave.configurationV1.configurationSet(parameterNumber: 101, size: 4, scaledConfigurationValue: 226) //association group 1
//4. report every x minutes (threshold reports don't work on battery power, default 8 mins)
request << zwave.configurationV1.configurationSet(parameterNumber: 111, size: 4, scaledConfigurationValue: timeOptionValueMap[reportInterval] ?: 8*60)
request << zwave.configurationV1.configurationSet(parameterNumber: 102, size: 4, scaledConfigurationValue: 1) //association group 2
//5. report automatically on threshold change
request << zwave.configurationV1.configurationSet(parameterNumber: 40, size: 1, scaledConfigurationValue: 1)
//3. no-motion report x seconds after motion stops (default 20 secs)
request << zwave.configurationV1.configurationSet(parameterNumber: 3, size: 2, scaledConfigurationValue: timeOptionValueMap[motionDelayTime] ?: 20)
//6. query sensor data
request << zwave.batteryV1.batteryGet()
request << zwave.sensorBinaryV2.sensorBinaryGet(sensorType: 0x0C) //motion
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x01) //temperature
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x03) //illuminance
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x05) //humidity
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x1B) //ultravioletIndex
//4. motionSensitivity 3 levels: 64-normal (default), 127-maximum, 0-minimum
request << zwave.configurationV1.configurationSet(parameterNumber: 6, size: 1,
scaledConfigurationValue:
motionSensitivity == "normal" ? 64 :
motionSensitivity == "maximum" ? 127 :
motionSensitivity == "minimum" ? 0 : 64)
setConfigured("true")
//5. report every x minutes (threshold reports don't work on battery power, default 8 mins)
request << zwave.configurationV1.configurationSet(parameterNumber: 111, size: 4, scaledConfigurationValue: timeOptionValueMap[reportInterval] ?: 8*60) //association group 1
commands(request) + ["delay 10000", zwave.wakeUpV1.wakeUpNoMoreInformation().format()]
}
request << zwave.configurationV1.configurationSet(parameterNumber: 112, size: 4, scaledConfigurationValue: 6*60*60) //association group 2
//6. report automatically on threshold change
request << zwave.configurationV1.configurationSet(parameterNumber: 40, size: 1, scaledConfigurationValue: 1)
//7. query sensor data
request << zwave.batteryV1.batteryGet()
request << zwave.sensorBinaryV2.sensorBinaryGet(sensorType: 0x0C) //motion
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x01) //temperature
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x03) //illuminance
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x05) //humidity
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x1B) //ultravioletIndex
setConfigured("true")
commands(request) + ["delay 20000", zwave.wakeUpV1.wakeUpNoMoreInformation().format()]
}