MSA-1925: The DH is developed by SmartThings and the only changes are made within Tiles and UI.

This commit is contained in:
Fredrik Westman
2017-04-28 02:03:16 -07:00
parent 7e8baeeb0b
commit 90d8534b46

View File

@@ -0,0 +1,182 @@
/**
* SmartSense Open/Closed Sensor
*
* Copyright 2014 SmartThings
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
*/
import physicalgraph.zigbee.clusters.iaszone.ZoneStatus
metadata {
definition(name: "Sensative ZB Strips", namespace: "sensative", author: "SmartThings") {
capability "Battery"
capability "Configuration"
capability "Contact Sensor"
capability "Refresh"
capability "Temperature Measurement"
capability "Health Check"
capability "Sensor"
command "enrollResponse"
fingerprint inClusters: "0000,0001,0003,0402,0500,0020,0B05", outClusters: "0019", manufacturer: "Sensative", model: "Strips-001"
fingerprint inClusters: "0000,0001,0003,0402,0500,0020,0B05", outClusters: "0019", manufacturer: "Sensative", model: "Strips-001"
fingerprint inClusters: "0000,0001,0003,0020,0402,0500,0B05", outClusters: "0019", manufacturer: "Sensativee", model: "Strips-001", deviceJoinName: "Sensative ZB Strips"
}
simulator {
}
preferences {
input title: "Temperature Offset", description: "This feature allows you to correct any temperature variations by selecting an offset. Ex: If your sensor consistently reports a temp that's 5 degrees too warm, you'd enter \"-5\". If 3 degrees too cold, enter \"+3\".", displayDuringSetup: false, type: "paragraph", element: "paragraph"
input "tempOffset", "number", title: "Degrees", description: "Adjust temperature by this many degrees", range: "*..*", displayDuringSetup: false
}
tiles(scale: 2) {
multiAttributeTile(name: "contact", type: "generic", width: 6, height: 4) {
tileAttribute("device.contact", key: "PRIMARY_CONTROL") {
attributeState "open", label: '${name}', icon: "st.contact.contact.open", backgroundColor: "#e86d13"
attributeState "closed", label: '${name}', icon: "st.contact.contact.closed", backgroundColor: "#00A0DC"
}
}
valueTile("temperature", "device.temperature", inactiveLabel: false, width: 2, height: 2) {
state "temperature", label: '${currentValue}°F',
backgroundColors: [
[value: 31, color: "#153591"],
[value: 44, color: "#1e9cbb"],
[value: 59, color: "#90d2a7"],
[value: 74, color: "#44b621"],
[value: 84, color: "#f1d801"],
[value: 95, color: "#d04e00"],
[value: 96, color: "#bc2323"]
]
}
valueTile("battery", "device.battery", decoration: "flat", inactiveLabel: false, width: 2, height: 2) {
state "battery", label: 'Battery\n${currentValue}%', unit: ""
}
standardTile("refresh", "device.refresh", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "default", action: "refresh.refresh", icon: "st.secondary.refresh"
}
main(["contact"])
details(["contact", "battery", "temperature", "refresh"])
}
}
def parse(String description) {
log.debug "description: $description"
Map map = zigbee.getEvent(description)
if (!map) {
if (description?.startsWith('zone status')) {
map = parseIasMessage(description)
} else {
Map descMap = zigbee.parseDescriptionAsMap(description)
if (descMap?.clusterInt == 0x0001 && descMap.commandInt != 0x07 && descMap?.value) {
map = getBatteryResult(Integer.parseInt(descMap.value, 16))
} else if (descMap?.clusterInt == zigbee.TEMPERATURE_MEASUREMENT_CLUSTER && descMap.commandInt == 0x07) {
if (descMap.data[0] == "00") {
log.debug "TEMP REPORTING CONFIG RESPONSE: $descMap"
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
} else {
log.warn "TEMP REPORTING CONFIG FAILED- error code: ${descMap.data[0]}"
}
}
}
} else if (map.name == "temperature") {
if (tempOffset) {
map.value = (int) map.value + (int) tempOffset
}
map.descriptionText = temperatureScale == 'C' ? '{{ device.displayName }} was {{ value }}°C' : '{{ device.displayName }} was {{ value }}°F'
map.translatable = true
}
log.debug "Parse returned $map"
def result = map ? createEvent(map) : [:]
if (description?.startsWith('enroll request')) {
List cmds = zigbee.enrollResponse()
log.debug "enroll response: ${cmds}"
result = cmds?.collect { new physicalgraph.device.HubAction(it) }
}
return result
}
private Map parseIasMessage(String description) {
ZoneStatus zs = zigbee.parseZoneStatus(description)
return zs.isAlarm1Set() ? getContactResult('open') : getContactResult('closed')
}
private Map getBatteryResult(rawValue) {
log.debug 'Battery'
def linkText = getLinkText(device)
def result = [:]
def volts = rawValue / 10
if (!(rawValue == 0 || rawValue == 255)) {
def minVolts = 2.1
def maxVolts = 3.0
def pct = (volts - minVolts) / (maxVolts - minVolts)
def roundedPct = Math.round(pct * 100)
if (roundedPct <= 0)
roundedPct = 1
result.value = Math.min(100, roundedPct)
result.descriptionText = "${linkText} battery was ${result.value}%"
result.name = 'battery'
}
return result
}
private Map getContactResult(value) {
log.debug 'Contact Status'
def linkText = getLinkText(device)
def descriptionText = "${linkText} was ${value == 'open' ? 'opened' : 'closed'}"
return [
name : 'contact',
value : value,
descriptionText: descriptionText
]
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
return zigbee.readAttribute(0x001, 0x0020) // Read the Battery Level
}
def refresh() {
log.debug "Refreshing Temperature and Battery"
def refreshCmds = zigbee.readAttribute(zigbee.TEMPERATURE_MEASUREMENT_CLUSTER, 0x0000) +
zigbee.readAttribute(zigbee.POWER_CONFIGURATION_CLUSTER, 0x0020)
return refreshCmds + zigbee.enrollResponse()
}
def configure() {
// Device-Watch allows 2 check-in misses from device + ping (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 2 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
log.debug "Configuring Reporting, IAS CIE, and Bindings."
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
// battery minReport 30 seconds, maxReportTime 6 hrs by default
return refresh() + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) // send refresh cmds as part of config
}