mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-08 05:31:56 +00:00
MSA-2116: FortrezZ OFFICIAL MiMOlite device handler for users to have as default. This handler provides use the interface for the relay and and signal input. Status tile's show either voltage or open/close status depending on the type of device connected. Device handler allows user to configure the Relay output between Latched & Momentary Toggle. The output can also be configured for a time delay up to 3 seconds. Configure tile added for users to press when requesting configuration changes.
This commit is contained in:
@@ -0,0 +1,204 @@
|
||||
/**
|
||||
* FortrezZ Flow Meter Interface
|
||||
*
|
||||
* Copyright 2016 FortrezZ, LLC
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
|
||||
* in compliance with the License. You may obtain a copy of the License at:
|
||||
*
|
||||
* http://www.apache.org/licenses/LICENSE-2.0
|
||||
*
|
||||
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
|
||||
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
* Based on Todd Wackford's MimoLite Garage Door Opener
|
||||
*/
|
||||
metadata {
|
||||
// Automatically generated. Make future change here.
|
||||
definition (name: "FortrezZ MIMOlite", namespace: "fortrezz", author: "FortrezZ, LLC") {
|
||||
capability "Configuration"
|
||||
capability "Switch"
|
||||
capability "Refresh"
|
||||
capability "Contact Sensor"
|
||||
capability "Voltage Measurement"
|
||||
|
||||
attribute "powered", "string"
|
||||
|
||||
command "on"
|
||||
command "off"
|
||||
|
||||
fingerprint deviceId: "0x1000", inClusters: "0x72,0x86,0x71,0x30,0x31,0x35,0x70,0x85,0x25,0x03"
|
||||
}
|
||||
|
||||
simulator {
|
||||
// Simulator stuff
|
||||
|
||||
}
|
||||
|
||||
preferences {
|
||||
input "RelaySwitchDelay", "decimal", title: "Delay between relay switch on and off in seconds. Only Numbers 0 to 3.0 allowed. 0 value will remove delay and allow relay to function as a standard switch", description: "Numbers 0 to 3.1 allowed.", defaultValue: 0, required: false, displayDuringSetup: true
|
||||
}
|
||||
|
||||
|
||||
// UI tile definitions
|
||||
tiles (scale: 2) {
|
||||
standardTile("switch", "device.switch", width: 4, height: 4, canChangeIcon: false, decoration: "flat") {
|
||||
state "on", label: "On", action: "off", icon: "http://swiftlet.technology/wp-content/uploads/2016/06/Switch-On-104-edit.png", backgroundColor: "#53a7c0"
|
||||
state "off", label: 'Off', action: "on", icon: "http://swiftlet.technology/wp-content/uploads/2016/06/Switch-Off-104-edit.png", backgroundColor: "#ffffff"
|
||||
}
|
||||
standardTile("contact", "device.contact", width: 2, height: 2, inactiveLabel: false) {
|
||||
state "open", label: '${name}', icon: "st.contact.contact.open", backgroundColor: "#ffa81e"
|
||||
state "closed", label: '${name}', icon: "st.contact.contact.closed", backgroundColor: "#79b821"
|
||||
}
|
||||
standardTile("refresh", "device.switch", width: 2, height: 2, inactiveLabel: false, decoration: "flat") {
|
||||
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
|
||||
}
|
||||
standardTile("powered", "device.powered", width: 2, height: 2, inactiveLabel: false) {
|
||||
state "powerOn", label: "Power On", icon: "st.switches.switch.on", backgroundColor: "#79b821"
|
||||
state "powerOff", label: "Power Off", icon: "st.switches.switch.off", backgroundColor: "#ffa81e"
|
||||
}
|
||||
standardTile("configure", "device.configure", width: 2, height: 2, inactiveLabel: false, decoration: "flat") {
|
||||
state "configure", label:'', action:"configuration.configure", icon:"st.secondary.configure"
|
||||
}
|
||||
valueTile("voltage", "device.voltage", width: 2, height: 2) {
|
||||
state "val", label:'${currentValue}v', unit:"", defaultState: true
|
||||
}
|
||||
valueTile("voltageCounts", "device.voltageCounts", width: 2, height: 2) {
|
||||
state "val", label:'${currentValue}', unit:"", defaultState: true
|
||||
}
|
||||
main (["switch"])
|
||||
details(["switch", "contact", "voltage", "powered", "refresh","configure"])
|
||||
}
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
//log.debug "description is: ${description}"
|
||||
|
||||
def result = null
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x84: 1, 0x30: 1, 0x70: 1, 0x31: 5])
|
||||
|
||||
//log.debug "command value is: $cmd.CMD"
|
||||
|
||||
if (cmd.CMD == "7105") { //Mimo sent a power loss report
|
||||
log.debug "Device lost power"
|
||||
sendEvent(name: "powered", value: "powerOff", descriptionText: "$device.displayName lost power")
|
||||
} else {
|
||||
sendEvent(name: "powered", value: "powerOn", descriptionText: "$device.displayName regained power")
|
||||
}
|
||||
//log.debug "${device.currentValue('contact')}" // debug message to make sure the contact tile is working
|
||||
if (cmd) {
|
||||
result = createEvent(zwaveEvent(cmd))
|
||||
}
|
||||
log.debug "Parse returned ${result?.descriptionText} $cmd.CMD"
|
||||
return result
|
||||
}
|
||||
|
||||
def updated() {
|
||||
log.debug "Settings Updated..."
|
||||
configure()
|
||||
}
|
||||
//notes about zwaveEvents:
|
||||
// these are special overloaded functions which MUST be returned with a map similar to (return [name: "switch", value: "on"])
|
||||
// not doing so will produce a null on the parse function, this will mess you up in the future.
|
||||
// Perhaps can use 'createEvent()' and return that as long as a map is inside it.
|
||||
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd) {
|
||||
log.debug "switchBinaryReport ${cmd}"
|
||||
if (cmd.value) // if the switch is on it will not be 0, so on = true
|
||||
{
|
||||
return [name: "switch", value: "on"] // change switch value to on
|
||||
}
|
||||
else // if the switch sensor report says its off then do...
|
||||
{
|
||||
return [name: "switch", value: "off"] // change switch value to off
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
// working on next for the analogue and digital stuff.
|
||||
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd) // basic set is essentially our digital sensor for SIG1
|
||||
{
|
||||
log.debug "sent a BasicSet command"
|
||||
//refresh()
|
||||
delayBetween([zwave.sensorMultilevelV5.sensorMultilevelGet().format()])// requests a report of the anologue input voltage
|
||||
[name: "contact", value: cmd.value ? "open" : "closed"]}
|
||||
//[name: "contact", value: cmd.value ? "open" : "closed", type: "digital"]}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.sensorbinaryv1.SensorBinaryReport cmd)
|
||||
{
|
||||
log.debug "sent a sensorBinaryReport command"
|
||||
refresh()
|
||||
[name: "contact", value: cmd.value ? "open" : "closed"]
|
||||
}
|
||||
|
||||
|
||||
|
||||
def zwaveEvent (physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd) // sensorMultilevelReport is used to report the value of the analog voltage for SIG1
|
||||
{
|
||||
log.debug "sent a SensorMultilevelReport"
|
||||
def ADCvalue = cmd.scaledSensorValue
|
||||
sendEvent(name: "voltageCounts", value: ADCvalue)
|
||||
|
||||
CalculateVoltage(cmd.scaledSensorValue)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
// Handles all Z-Wave commands we aren't interested in
|
||||
log.debug("Un-parsed Z-Wave message ${cmd}")
|
||||
[:]
|
||||
}
|
||||
|
||||
def CalculateVoltage(ADCvalue)
|
||||
{
|
||||
def map = [:]
|
||||
|
||||
def volt = (((1.5338*(10**-16))*(ADCvalue**5)) - ((1.2630*(10**-12))*(ADCvalue**4)) + ((3.8111*(10**-9))*(ADCvalue**3)) - ((4.7739*(10**-6))*(ADCvalue**2)) + ((2.8558*(10**-3))*(ADCvalue)) - (2.2721*(10**-2)))
|
||||
|
||||
//def volt = (((3.19*(10**-16))*(ADCvalue**5)) - ((2.18*(10**-12))*(ADCvalue**4)) + ((5.47*(10**-9))*(ADCvalue**3)) - ((5.68*(10**-6))*(ADCvalue**2)) + (0.0028*ADCvalue) - (0.0293))
|
||||
//log.debug "$cmd.scale $cmd.precision $cmd.size $cmd.sensorType $cmd.sensorValue $cmd.scaledSensorValue"
|
||||
def voltResult = volt.round(1)// + "v"
|
||||
|
||||
map.name = "voltage"
|
||||
map.value = voltResult
|
||||
map.unit = "v"
|
||||
return map
|
||||
}
|
||||
|
||||
|
||||
def configure() {
|
||||
def x = (RelaySwitchDelay*10).toInteger()
|
||||
log.debug "Configuring.... " //setting up to monitor power alarm and actuator duration
|
||||
|
||||
delayBetween([
|
||||
zwave.associationV1.associationSet(groupingIdentifier:3, nodeId:[zwaveHubNodeId]).format(), // FYI: Group 3: If a power dropout occurs, the MIMOlite will send an Alarm Command Class report
|
||||
// (if there is enough available residual power)
|
||||
zwave.associationV1.associationSet(groupingIdentifier:2, nodeId:[zwaveHubNodeId]).format(), // periodically send a multilevel sensor report of the ADC analog voltage to the input
|
||||
zwave.associationV1.associationSet(groupingIdentifier:4, nodeId:[zwaveHubNodeId]).format(), // when the input is digitally triggered or untriggered, snd a binary sensor report
|
||||
zwave.configurationV1.configurationSet(configurationValue: [x], parameterNumber: 11, size: 1).format() // configurationValue for parameterNumber means how many 100ms do you want the relay
|
||||
// to wait before it cycles again / size should just be 1 (for 1 byte.)
|
||||
//zwave.configurationV1.configurationGet(parameterNumber: 11).format() // gets the new parameter changes. not currently needed. (forces a null return value without a zwaveEvent funciton
|
||||
])
|
||||
}
|
||||
|
||||
def on() {
|
||||
delayBetween([
|
||||
zwave.basicV1.basicSet(value: 0xFF).format(), // physically changes the relay from on to off and requests a report of the relay
|
||||
refresh()// to make sure that it changed (the report is used elsewhere, look for switchBinaryReport()
|
||||
])
|
||||
}
|
||||
|
||||
def off() {
|
||||
delayBetween([
|
||||
zwave.basicV1.basicSet(value: 0x00).format(), // physically changes the relay from on to off and requests a report of the relay
|
||||
refresh()// to make sure that it changed (the report is used elsewhere, look for switchBinaryReport()
|
||||
])
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
log.debug "REFRESH!"
|
||||
delayBetween([
|
||||
zwave.switchBinaryV1.switchBinaryGet().format(), //requests a report of the relay to make sure that it changed (the report is used elsewhere, look for switchBinaryReport()
|
||||
zwave.sensorMultilevelV5.sensorMultilevelGet().format()// requests a report of the anologue input voltage
|
||||
|
||||
])
|
||||
}
|
||||
Reference in New Issue