Merge pull request #572 from workingmonk/bug/battery_values

[DVCSMP-1255] Fixing issue with weird battery values
This commit is contained in:
Vinay Rao
2016-03-01 17:01:27 -08:00
4 changed files with 7 additions and 4 deletions

View File

@@ -231,7 +231,7 @@ private Map getBatteryResult(rawValue) {
def volts = rawValue / 10
def descriptionText
if (rawValue == 0) {}
if (rawValue == 0 || rawValue == 255) {}
else {
if (volts > 3.5) {
result.descriptionText = "${linkText} battery has too much power (${volts} volts)."

View File

@@ -225,7 +225,8 @@ def getTemperature(value) {
def volts = rawValue / 10
def descriptionText
if (volts > 3.5) {
if (rawValue == 0 || rawValue == 255) {}
else if (volts > 3.5) {
result.descriptionText = "${linkText} battery has too much power (${volts} volts)."
}
else {

View File

@@ -220,7 +220,8 @@ private Map getBatteryResult(rawValue) {
def volts = rawValue / 10
def descriptionText
if (volts > 3.5) {
if (rawValue == 0 || rawValue == 255) {}
else if (volts > 3.5) {
result.descriptionText = "${linkText} battery has too much power (${volts} volts)."
}
else {

View File

@@ -196,7 +196,8 @@ private Map getBatteryResult(rawValue) {
def volts = rawValue / 10
def descriptionText
if (volts > 3.5) {
if (rawValue == 0 || rawValue == 255) {}
else if (volts > 3.5) {
result.descriptionText = "${linkText} battery has too much power (${volts} volts)."
}
else {