CHF-406
Updated HealthCheck Implementation for Z-wave Dimmer (GE 12718, GE 12724, GE 12729) with checkInterval of 32min
This commit is contained in:
2
devicetypes/smartthings/dimmer-switch.src/.st-ignore
Normal file
2
devicetypes/smartthings/dimmer-switch.src/.st-ignore
Normal file
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
45
devicetypes/smartthings/dimmer-switch.src/README.md
Normal file
45
devicetypes/smartthings/dimmer-switch.src/README.md
Normal file
@@ -0,0 +1,45 @@
|
||||
# Z-wave Dimmer Switch
|
||||
|
||||
|
||||
|
||||
Works with:
|
||||
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (GE 12724)](http://products.z-wavealliance.org/products/1197)
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (Toggle) (GE 12729)](http://products.z-wavealliance.org/products/1201)
|
||||
* [GE Z-Wave Plug-in Smart Dimmer (GE 12718)](http://products.z-wavealliance.org/products/1191)
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
* [Troubleshooting](#Troubleshooting)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Switch Level** - it's defined to accept two parameters, the level and the rate of dimming
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Indicator** - gives you the ability to set the indicator LED light on a Z-Wave switch
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Polling** - represents that poll() can be implemented for the device
|
||||
* **Refresh** - _refresh()_ command for status updates
|
||||
* **Sensor** - detects sensor events
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
|
||||
## Device Health
|
||||
|
||||
Z-Wave Smart Dimmers (In-Wall, In-Wall(Toggle), Plug-In) are polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Check-in interval = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [General Z-Wave Dimmer/Switch Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200955890-Troubleshooting-GE-in-wall-switch-or-dimmer-won-t-respond-to-commands-or-automations-Z-Wave-)
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (GE 12724) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200902600-GE-In-Wall-Paddle-Dimmer-Switch-GE-12724-Z-Wave-)
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (Toggle) (GE 12729) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/207568463-GE-In-Wall-Smart-Toggle-Dimmer-GE-12729-Z-Wave-)
|
||||
* [GE Z-Wave Plug-in Smart Dimmer (GE 12718) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202088474-GE-Plug-In-Smart-Dimmer-GE-12718-Z-Wave-)
|
||||
@@ -20,6 +20,7 @@ metadata {
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Health Check"
|
||||
|
||||
fingerprint mfr:"0063", prod:"4457", deviceJoinName: "Z-Wave Wall Dimmer"
|
||||
fingerprint mfr:"0063", prod:"4944", deviceJoinName: "Z-Wave Wall Dimmer"
|
||||
@@ -82,6 +83,8 @@ metadata {
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
switch (ledIndicator) {
|
||||
case "on":
|
||||
indicatorWhenOn()
|
||||
@@ -215,6 +218,13 @@ def poll() {
|
||||
zwave.switchMultilevelV1.switchMultilevelGet().format()
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
log.debug "refresh() is called"
|
||||
def commands = []
|
||||
|
||||