[CHF-571] [CHF-568] Revert untested Health Check on Keen Home & EcoNet Vents

This commit is contained in:
jackchi
2017-04-03 16:47:15 -07:00
parent ae41b4adbe
commit d51ec9e518
2 changed files with 5 additions and 5 deletions

View File

@@ -11,7 +11,7 @@ metadata {
capability "Sensor"
capability "Temperature Measurement"
capability "Battery"
capability "Health Check"
// capability "Health Check"
command "getLevel"
command "getOnOff"
@@ -476,7 +476,7 @@ def configure() {
// Device-Watch allows 2 check-in misses from device + ping (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 2 * 10 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
// sendEvent(name: "checkInterval", value: 2 * 10 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
// get ZigBee ID by hidden tile because that's the only way we can do it
setZigBeeIdTile()

View File

@@ -26,13 +26,13 @@ metadata {
capability "Sensor"
capability "Polling"
capability "Configuration"
capability "Health Check"
// capability "Health Check"
command "open"
command "close"
fingerprint deviceId: "0x1100", inClusters: "0x26,0x72,0x86,0x77,0x80,0x20"
fingerprint mfr:"0157", prod:"0100", model:"0100", deviceJoinName: "EcoNet Controls Z-Wave Vent"
// fingerprint mfr:"0157", prod:"0100", model:"0100", deviceJoinName: "EcoNet Controls Z-Wave Vent"
}
simulator {
@@ -88,7 +88,7 @@ def parse(String description) {
//send the command to stop polling
def updated() {
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
// sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
response("poll stop")
}