Added Health Check Implementation for Zigbee Button.
This commit is contained in:
sushant.k1
2017-06-19 15:33:01 +05:30
parent d6b0f6a8ed
commit e8939a77d7
3 changed files with 55 additions and 0 deletions

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,43 @@
# ZigBee Button
Cloud Execution
Works with:
* [OSRAM LIGHTIFY Dimming Switch](https://support.smartthings.com/hc/en-us/articles/115000236823-SYLVANIA-Dimming-Switch)
* [Iris Smart Button](https://support.smartthings.com/hc/en-us/articles/115000190186-Iris-Smart-Button)
* [Iris KeyFob](https://support.smartthings.com/hc/en-us/articles/217409686-Iris-Smart-Fob)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Actuator** - It represents that a device has commands.
* **Battery** - It defines that the device has a battery
* **Button** - It defines that a device has one or more buttons
* **Holdable Button** - It defines that a device has one or more holdable buttons
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - it represents that a Device has attributes.
* **Health Check** - indicates ability to get device health notifications
## Device Health
SmartThings platform will ping the device after `checkInterval` seconds of inactivity in last attempt to reach the device before marking it `OFFLINE`
* __722min__ checkInterval
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
It may also happen that you need to reset the device.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [OSRAM LIGHTIFY Dimming Switch Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/115000236823-SYLVANIA-Dimming-Switch)
* [Iris Smart Button Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/115000190186-Iris-Smart-Button)
* [Iris KeyFob Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/217409686-Iris-Smart-Fob)

View File

@@ -24,6 +24,7 @@ metadata {
capability "Configuration"
capability "Refresh"
capability "Sensor"
capability "Health Check"
command "enrollResponse"
@@ -182,6 +183,13 @@ private Map parseNonIasButtonMessage(Map descMap){
}
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
refresh()
}
def refresh() {
log.debug "Refreshing Battery"
@@ -190,6 +198,8 @@ def refresh() {
}
def configure() {
// Device-Watch allows 2 check-in misses from device (plus 2 mins lag time)
sendEvent(name: "checkInterval", value: 2 * 6 * 60 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
log.debug "Configuring Reporting, IAS CIE, and Bindings."
def cmds = []
if (device.getDataValue("model") == "3450-L") {