Garage Door use case works + implemented code review feedback
Implementing code review feedback + inverted the signedY to match Centralite like behavior.
Implementing code review feedback + inverted the signedY to match Centralite like behavior.
The code can only correctly handle the accelerometer readings when they
are all received in the same message. Individual reads of the attributes
results in individual read attribute responses which led to events with
incorrect values. The most straightforward fix is to not read the attributes
in the first place and rely on attribute reporting to report the values
at the appropriate time.
Resolves:
https://smartthings.atlassian.net/browse/DVCSMP-1315
accelerometer attribute. Sometimes, however, they are all sent in the same
Attribute Report. When that happens, only the accelerometer attribute was
being handled and the x,y,z attributes were not. Now they are all handled
if they arrive in the same message.
Resolves:
https://smartthings.atlassian.net/browse/DVCSMP-1271
ZigBee locks report battery percentage remaining in .5% increments. However
the Low Battery Handler Smart App in Hello Home expects it to be an integer.
https://smartthings.atlassian.net/browse/DVCSMP-1189
Detect and mark device offline within 5 minutes.
Show Device offline in device tile.
Show Device offline in Recent Activity.
Log the current IP address to Recent Activity.
Log the changed IP address to Recent Activity.
Support 'Turning on' and 'Turning off' (blindly changing the state of
device to ON or OFF without confirming bulb responded correctly)
Turn on / off through Wemo-App reflected timely in SmartThings
App/Ecosystem.
Manual turn on / off of device is reflected timely in SmartThings
App/Ecosystem.
Lower case createEvent
Bug Fixes
Bug fixes
setOffline
Minor cosmetic fixes
- Show batteryStatus tile insteady of battery tile to be able to display both when sensor is USB powered or battery powered
- Remove background for illuminance. This can be added when we have best practice of showing colors for lux.
- Instead of using powerSupply:failed, configurationGet cmd is sent and then the configure() is triggered by configurationReport to determine powerSupply (USB Cable/Battery)
- Instead of querying battery level on wake up, battery report is put in association group 2 that is configured to report every 6 hours by default
- Update configure() to send both unsecure and secure configuration commands when sensor is joined normally or securely