Compare commits

...

10 Commits

Author SHA1 Message Date
João Borges
8a175bdac0 MSA-1574: descricao 2016-11-08 04:52:55 -06:00
Jack Chi
f7dbabb6c8 Merge pull request #1430 from skt123/wemo_bulb
[CHF-441] Added Health Check Implementation for WeMo LED Bulb
2016-11-07 22:18:52 -08:00
Jack Chi
7016e234d2 Merge pull request #1431 from skt123/osram_rt5/6_tunable_white
[CHF-442] Added Health Check Implementation for following Osram RT5/6 Tunable White
2016-11-07 22:17:54 -08:00
Jack Chi
cf119b1d15 Merge pull request #1433 from parijatdas/leviton_universal_dimmer
[CHF-455] Implementation of HealthCheck for Leviton Universal Dimmer DZMX1-LZ (Z-wave)
2016-11-07 22:16:05 -08:00
Jack Chi
3e88f3c4bd Merge pull request #1432 from parijatdas/leviton_switch
[CHF-454] [CHF-456] Implementation of HealthCheck for Leviton Switch DZS15-1LZ (Z-wave) and Leviton Outlet DZR15-1LZ (Z-wave)
2016-11-07 22:13:37 -08:00
sushant.k1
8ca20ce87e Added Health Check Implementation for following WeMo LED Bulb 2016-11-08 10:57:49 +05:30
sushant.k1
c1d520a578 Added Health Check Implementation for following Osram RT5/6 Tunable White 2016-11-08 10:53:44 +05:30
Parijat Das
c0bb0554d8 Added fingerprint of Leviton Outlet and Leviton Switch with health check already implemented and modified readme file accordingly 2016-11-08 09:12:48 +05:30
Parijat Das
b6790729c6 Added fingerprint of Leviton Universal Dimmer with health check already implemented 2016-11-08 09:06:36 +05:30
Juan Pablo Risso
bd1ace96de DVCSMP-2178 - Add thermostats to Logitech Harmony (#1408) 2016-11-04 16:41:41 -04:00
9 changed files with 92 additions and 20 deletions

View File

@@ -1,10 +1,11 @@
# OSRAM Lightify LED On/Off/Dim
# Zigbee Dimmer
Works with:
* [OSRAM Lightify LED On/Off/Dim](https://shop.smartthings.com/#!/products/osram-led-smart-bulb-on-off-dim)
* [WeMo LED Bulb](https://support.smartthings.com/hc/en-us/articles/204259040-Belkin-WeMo-LED-Bulb-F7C033-)
## Table of contents
@@ -23,14 +24,16 @@ Works with:
## Device Health
A Category C1 Zigbee dimmer with maxReportTime of 5 mins.
Check-in interval is double the value of maxReportTime.
A Zigbee dimmer with maxReportTime of 5 mins.
Check-in interval is double the value of maxReportTime.
This gives the device twice the amount of time to respond before it is marked as offline.
Check-in interval = 12 mins
Enrolls with default periodic reporting until newer 5 min interval is confirmed
It then enrolls the device with updated checkInterval i.e. 12 mins
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Other troubleshooting tips are listed as follows:
* [Troubleshooting:](https://support.smartthings.com/hc/en-us/articles/207191763-OSRAM-LIGHTIFY-LED-Smart-Connected-Light-A19-On-Off-Dim)
* [OSRAM Lightify LED On/Off/Dim Troubleshooting:](https://support.smartthings.com/hc/en-us/articles/207191763-OSRAM-LIGHTIFY-LED-Smart-Connected-Light-A19-On-Off-Dim)
* [WeMo LED Bulb Troubleshooting:](https://support.smartthings.com/hc/en-us/articles/204259040-Belkin-WeMo-LED-Bulb-F7C033-)

View File

@@ -1,10 +1,11 @@
# OSRAM Lightify Tunable 60 White
# ZigBee White Color Temperature Bulb
Works with:
* [OSRAM Lightify Tunable 60 White](http://www.osram.com/osram_com/tools-and-services/tools/lightify---smart-connected-light/lightify-for-home---what-is-light-to-you/lightify-products/lightify-classic-a60-tunable-white/index.jsp)
* [OSRAM LIGHTIFY RT5/6 Tunable White](https://www.smartthings.com/works-with-smartthings/light-bulbs/osram-lightify-rt56-tunable-white)
## Table of contents
@@ -24,14 +25,16 @@ Works with:
## Device Health
A Category C1 OSRAM Lightify Tunable 60 White with maxReportTime of 5 mins.
Check-in interval is double the value of maxReportTime.
Zigbee Bulb with maxReportTime of 5 mins.
Check-in interval is double the value of maxReportTime.
This gives the device twice the amount of time to respond before it is marked as offline.
Check-in interval = 12 mins
Enrolls with default periodic reporting until newer 5 min interval is confirmed
It then enrolls the device with updated checkInterval i.e. 12 mins
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Other troubleshooting tips are listed as follows:
* [Troubleshooting:](https://support.smartthings.com/hc/en-us/articles/204576454-OSRAM-LIGHTIFY-Tunable-White-60-Bulb)
* [OSRAM Lightify Tunable 60 White Troubleshooting](https://support.smartthings.com/hc/en-us/articles/204576454-OSRAM-LIGHTIFY-Tunable-White-60-Bulb)
* [OSRAM LIGHTIFY RT5/6 Tunable White Troubleshooting](https://support.smartthings.com/hc/en-us/articles/214191863-How-to-connect-OSRAM-LIGHTIFY-Bulbs)

View File

@@ -33,7 +33,7 @@ metadata {
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300", outClusters: "0019"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B04", outClusters: "0019"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY BR Tunable White", deviceJoinName: "OSRAM LIGHTIFY LED Flood BR30 Tunable White"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY RT Tunable White", deviceJoinName: "OSRAM LIGHTIFY LED Recessed Kit RT 5/6 Tunable White"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY RT Tunable White", deviceJoinName: "OSRAM LIGHTIFY RT5/6 Tunable White"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "Classic A60 TW", deviceJoinName: "OSRAM LIGHTIFY LED Tunable White 60W"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY A19 Tunable White", deviceJoinName: "OSRAM LIGHTIFY LED Tunable White 60W"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "Classic B40 TW - LIGHTIFY", deviceJoinName: "OSRAM LIGHTIFY Classic B40 Tunable White"

View File

@@ -4,7 +4,8 @@
Works with:
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW)](http://www.leviton.com/OA_HTML/ProductDetail.jsp?partnumber=DZPD3-1LW)
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW)](https://www.smartthings.com/works-with-smartthings/outlets/leviton-plug-in-lamp-dimmer-module)
* [Leviton Universal Dimmer (DZMX1-LZ)](https://www.smartthings.com/works-with-smartthings/switches-and-dimmers/leviton-universal-dimmer)
## Table of contents
@@ -24,7 +25,7 @@ Works with:
## Device Health
A Category C5 Leviton Plug-in Lamp Dimmer Module (DZPA1-1LW) (Z-Wave) polled by the hub.
Leviton Plug-in Lamp Dimmer Module (DZPA1-1LW) (Z-wave) and Leviton Universal Dimmer (DZMX1-LZ) (Z-Wave) are polled by the hub.
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
@@ -36,4 +37,5 @@ it is not polled for 5 minutes by the hub. This can delay up the process of bein
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton Universal Dimmer (DZMX1-LZ) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)

View File

@@ -23,6 +23,7 @@ metadata {
fingerprint inClusters: "0x26", deviceJoinName: "Z-Wave Dimmer"
fingerprint mfr:"001D", prod:"1902", deviceJoinName: "Z-Wave Dimmer"
fingerprint mfr:"001D", prod:"1B03", model:"0334", deviceJoinName: "Leviton Universal Dimmer"
}
simulator {

View File

@@ -4,8 +4,10 @@
Works with:
* [Leviton Appliance Module (DZPA1-1LW)](https://support.smartthings.com/hc/en-us/articles/205881176-Leviton-Appliance-Module-DZPA1-1LW-)
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave)](https://support.smartthings.com/hc/en-us/articles/200903080-GE-Plug-In-Outdoor-Smart-Switch-GE-12720-Z-Wave-)
* [Leviton Appliance Module (DZPA1-1LW)](https://www.smartthings.com/works-with-smartthings/outlets/leviton-appliance-module)
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave)](https://www.smartthings.com/works-with-smartthings/outlets/ge-plug-in-outdoor-smart-switch)
* [Leviton Outlet (DZR15-1LZ)](https://www.smartthings.com/works-with-smartthings/outlets/leviton-outlet)
* [Leviton Switch (DZS15-1LZ)](https://www.smartthings.com/works-with-smartthings/switches-and-dimmers/leviton-switch)
## Table of contents
@@ -23,7 +25,7 @@ Works with:
## Device Health
A Category C5 Leviton Appliance Module (DZPA1-1LW) and GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) polled by the hub.
Leviton Appliance Module (DZPA1-1LW), GE Plug-In Outdoor Smart Switch (GE 12720), Leviton Outlet (DZR15-1LZ) and Leviton Switch (DZS15-1LZ) (Z-Wave) are polled by the hub.
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
@@ -35,5 +37,7 @@ it is not polled for 5 minutes by the hub. This can delay up the process of bein
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [Leviton Appliance Module (DZPA1-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205881176-Leviton-Appliance-Module-DZPA1-1LW-)
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200903080-GE-Plug-In-Outdoor-Smart-Switch-GE-12720-Z-Wave-)
* [Leviton Appliance Module (DZPA1-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200903080-GE-Plug-In-Outdoor-Smart-Switch-GE-12720-Z-Wave-)
* [Leviton Outlet (DZR15-1LZ) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton Switch (DZS15-1LZ) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)

View File

@@ -23,6 +23,8 @@ metadata {
fingerprint inClusters: "0x25", deviceJoinName: "Z-Wave Switch"
fingerprint mfr:"001D", prod:"1A02", model:"0334", deviceJoinName: "Leviton Appliance Module"
fingerprint mfr:"0063", prod:"4F50", model:"3031", deviceJoinName: "GE Plug-in Outdoor Switch"
fingerprint mfr:"001D", prod:"1D04", model:"0334", deviceJoinName: "Leviton Outlet"
fingerprint mfr:"001D", prod:"1C02", model:"0334", deviceJoinName: "Leviton Switch"
}
// simulator metadata

View File

@@ -0,0 +1,50 @@
/**
* name
*
* Copyright 2016 João Borges
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
*/
definition(
name: "name",
namespace: "namespace",
author: "João Borges",
description: "description",
category: "SmartThings Labs",
iconUrl: "https://s3.amazonaws.com/smartapp-icons/Convenience/Cat-Convenience.png",
iconX2Url: "https://s3.amazonaws.com/smartapp-icons/Convenience/Cat-Convenience@2x.png",
iconX3Url: "https://s3.amazonaws.com/smartapp-icons/Convenience/Cat-Convenience@2x.png")
preferences {
section("Title") {
// TODO: put inputs here
}
}
def installed() {
log.debug "Installed with settings: ${settings}"
initialize()
}
def updated() {
log.debug "Updated with settings: ${settings}"
unsubscribe()
initialize()
}
def initialize() {
// TODO: subscribe to attributes, devices, locations, etc.
}
// TODO: implement event handlers

View File

@@ -24,6 +24,12 @@
* switches | switch | on, off | on, off
* motionSensors | motion | | active, inactive
* contactSensors | contact | | open, closed
* thermostat | thermostat | setHeatingSetpoint, | temperature, heatingSetpoint
* | | setCoolingSetpoint(number) | coolingSetpoint, thermostatSetpoint
* | | off, heat, emergencyHeat | thermostatMode — ["emergency heat", "auto", "cool", "off", "heat"]
* | | cool, setThermostatMode | thermostatFanMode — ["auto", "on", "circulate"]
* | | fanOn, fanAuto, fanCirculate| thermostatOperatingState — ["cooling", "heating", "pending heat",
* | | setThermostatFanMode, auto | "fan only", "vent economizer", "pending cool", "idle"]
* presenceSensors | presence | | present, 'not present'
* temperatureSensors | temperature | | <numeric, F or C according to unit>
* accelerationSensors | acceleration | | active, inactive
@@ -58,6 +64,7 @@ preferences(oauthPage: "deviceAuthorization") {
input "switches", "capability.switch", title: "Which Switches?", multiple: true, required: false
input "motionSensors", "capability.motionSensor", title: "Which Motion Sensors?", multiple: true, required: false
input "contactSensors", "capability.contactSensor", title: "Which Contact Sensors?", multiple: true, required: false
input "thermostats", "capability.thermostat", title: "Which Thermostats?", multiple: true, required: false
input "presenceSensors", "capability.presenceSensor", title: "Which Presence Sensors?", multiple: true, required: false
input "temperatureSensors", "capability.temperatureMeasurement", title: "Which Temperature Sensors?", multiple: true, required: false
input "accelerationSensors", "capability.accelerationSensor", title: "Which Vibration Sensors?", multiple: true, required: false
@@ -936,7 +943,7 @@ def deleteHarmony() {
}
private getAllDevices() {
([] + switches + motionSensors + contactSensors + presenceSensors + temperatureSensors + accelerationSensors + waterSensors + lightSensors + humiditySensors + alarms + locks)?.findAll()?.unique { it.id }
([] + switches + motionSensors + contactSensors + thermostats + presenceSensors + temperatureSensors + accelerationSensors + waterSensors + lightSensors + humiditySensors + alarms + locks)?.findAll()?.unique { it.id }
}
private deviceItem(device) {