Compare commits

...

23 Commits

Author SHA1 Message Date
Vinay Rao
7e8baeeb0b Merge pull request #1948 from SmartThingsCommunity/staging
Rolling down staging hotfix to master
2017-04-25 15:57:52 -07:00
Vinay Rao
62991f8d23 Merge pull request #1946 from SmartThingsCommunity/production
Rolling down production to staging
2017-04-25 15:27:16 -07:00
Stephen Stack
ad824a9dd8 Merge pull request #1934 from SmartThingsCommunity/multi-sensor-accel-fix
DVCSMP-2573: Acceleration axis validation (Multi sensor DTH)
2017-04-25 15:11:54 -05:00
Vinay Rao
11f2775568 Merge pull request #1944 from dkirker/DVCSMP-2579
DVCSMP-2579 Move Centralite Door/Window sensor from multi-sensor DTH to open-closed-sensor DTH
2017-04-25 12:02:56 -07:00
Vinay Rao
83b65c0d87 Merge pull request #1923 from dkirker/DVCSMP-2585
DVCSMP-2585 Fix NullPointerException when pairing because color is unset
2017-04-25 12:01:23 -07:00
Vinay Rao
e641759a47 Merge pull request #1942 from dkirker/DVCSMP-2598
DVCSMP-2598 Fix Wattvision throwing HttpResponseException
2017-04-25 11:33:00 -07:00
Donald Kirker
7820b39b2b DVCSMP-2579 Move Centralite Door/Window sensor from multi-sensor DTH to open-closed-sensor DTH. 2017-04-25 03:18:54 -07:00
Donald Kirker
6a76a8ee39 DVCSMP-2598 Fix start_time and end_time date range
Add descriptive error for Wattvision API errors
2017-04-24 16:19:20 -07:00
Stephen Stack
980bef6879 DVCSMP-2573: Acceleration axis validation (Multi sensor DTH)
In certain cases the SmartSense Multi Sensors are
missing the Y and Z axis, causing an exception
during .parseAxis(). This change checks that all
3 axis are present before processing the rest of
the message.
2017-04-24 16:51:03 -05:00
Zach Varberg
120935f14e Merge pull request #1940 from varzac/sengled-button-level-fix
[DVCSMP-2597] Fix sengled use of FF for max level
2017-04-24 16:01:36 -05:00
Donald Kirker
c864fc521e DVCSMP-2585 Fix NullPointerException when pairing because color is unset
Also tweak default config values in config value range checking (affects initial pairing of device)
2017-04-24 10:57:07 -07:00
Jack Chi
032f4a92d4 Merge pull request #1937 from parijatdas/smartalert_siren
[CHF-590] Health Check smartalert-siren
2017-04-25 01:58:13 +09:00
Jack Chi
6d528683e6 Merge pull request #1904 from pchomal/plantlink_hc
[CHF-561] Health Check Plant Link
2017-04-25 01:51:24 +09:00
Zach Varberg
8bcbe7b924 Fix sengled use of FF for max level
This works around the fact that sengled element touches can get back
into a state of reporting an invalid value (of FF) if the physical
button on the bulb is used to cycle back to the 100% state.  Here we
interpret FF as FE for sengled and then issue a move to level command to
put it in a state where it will report FE until the level is changed
again.

This resolves: https://smartthings.atlassian.net/browse/DVCSMP-2597
2017-04-24 09:49:02 -05:00
Parijat Das
69dd13f333 Added healthcheck for SmartAlert Siren 2017-04-24 12:36:53 +05:30
Vinay Rao
016425b7c8 Merge pull request #1935 from workingmonk/bug/dimmer_light
ICP-731 Wrong icon for dimmer
2017-04-21 17:16:41 -07:00
Vinay Rao
c164b201ca ICP-731 wrong icon for dimmer 2017-04-21 17:16:12 -07:00
Vinay Rao
030dd47b69 Merge pull request #1933 from jackchi/health-arrival-sensor-ha
[CHF-602] Health Check Arrival Sensor HA
2017-04-21 14:16:54 -07:00
Vinay Rao
cc68534b47 Merge pull request #1932 from jackchi/health-arrival-sensor
[CHF-601] Health Check Arrival Sensor (2015 Model)
2017-04-21 14:16:35 -07:00
jackchi
5e07494dff [CHF-602] Health Check Arrival Sensor HA 2017-04-22 04:28:50 +09:00
jackchi
573630232f [CHF-601] Health Check Arrival Sensor (2015 Model) 2017-04-22 04:19:29 +09:00
piyush.c
29c7049d60 [CHF-561] Health Check Plant Link 2017-04-21 10:35:55 +05:30
Donald Kirker
fc32031555 Move revision history to README.md 2017-04-19 18:25:21 -07:00
23 changed files with 330 additions and 53 deletions

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,44 @@
# Express Controls EZMultiPli
Works with:
* [Express Controls EZMultiPli](https://www.smartthings.com/works-with-smartthings/)
## Table of contents
* [Release Notes](#release-notes)
* [Capabilities](#capabilities)
* [Troubleshooting](#troubleshooting)
## Release Notes
* **2017-04-19** - _dkirker_ - Update default config values in config value range check functions, use lux if lum option is null, fix NullPointerException on initial pairing when color data has not been set (and set the default color data!)
* **2017-04-10** - _DrZwave_ (with help from Donald Kirker) - changed fingerprint to the new format, lowered the OnTime and other parameters to be "more in line with ST user expectations", get the luminance in LUX so it reports in lux all the time.
* **2016-10-06** - _erocm1231_ - Added "updated" method to run when configuration options are changed. Depending on model of unit, luminance is being reported as a relative percentace or as a lux value. Added the option to configure this in the handler.
* **2016-01-28** - _erocm1231_ - Changed the configuration method to use scaledConfiguration so that it properly formatted negative numbers. Also, added configurationGet and a configurationReport method so that config values can be verified.
* **2015-12-04** - _erocm1231_ - added range value to preferences as suggested by @Dela-Rick.
* **2015-11-26** - _erocm1231_ - Fixed null condition error when adding as a new device.
* **2015-11-24** - _erocm1231_ - Added refresh command. Made a few changes to how the handler maps colors to the LEDs. Fixed the device not having its on/off status updated when colors are changed.
* **2015-11-23** - _erocm1231_ - Changed the look to match SmartThings v2 devices.
* **2015-11-21** - _erocm1231_ - Made code much more efficient. Also made it compatible when setColor is passed a hex value. Mapping of special colors: Soft White - Default - Yellow, White - Concentrate - White, Daylight - Energize - Teal, Warm White - Relax - Yellow
* **2015-11-19** - _erocm1231_ - Fixed a couple incorrect colors, changed setColor to be more compatible with other apps
* **2015-11-18** - _erocm1231_ - Added to setColor for compatibility with Smart Lighting
* **v0.1.0** - _DrZWave_ - chose better icons, Got color LED to work - first fully functional version
* **v0.0.9** - _jrs_ - got the temp and luminance to work. Motion works. Debugging the color wheel.
* **v0.0.8** - _DrZWave_ 2/25/2015 - change the color control to be tiles since there are only 8 colors.
* **v0.0.7** - _jrs_ - 02/23/2015 - Jim Sulin
## Capabilities
* **Actuator** - represents that a Device has commands
* **Sensor** - detects sensor events
* **Motion Sensor** - can detect motion
* **Temperature Measurement** - defines device measures current temperature
* **Illuminance Measurement** - gives the illuminance reading from devices that support it
* **Switch** - can detect state (possible values: on/off)
* **Color Control** - represents that the color attributes of a device can be controlled (hue, saturation, color value
* **Configuration** - configure() command called when device is installed or device preferences updated
* **Refresh** - refresh() command for status updates
## Troubleshooting

View File

@@ -2,27 +2,6 @@
// Motion Sensor - Temperature - Light level - 8 Color Indicator LED - Z-Wave Range Extender - Wall Powered
// driver for SmartThings
// The EZMultiPli is also known as the HSM200 from HomeSeer.com
//
// 2017-04-10 - DrZwave (with help from Don Kirker) - changed fingerprint to the new format, lowered the OnTime
// and other parameters to be "more in line with ST user expectations", get the luminance in LUX so it reports in lux all the time.
// 2016-10-06 - erocm1231 - Added "updated" method to run when configuration options are changed. Depending on model of unit, luminance is being
// reported as a relative percentace or as a lux value. Added the option to configure this in the handler.
// 2016-01-28 - erocm1231 - Changed the configuration method to use scaledConfiguration so that it properly formatted negative numbers.
// Also, added configurationGet and a configurationReport method so that config values can be verified.
// 2015-12-04 - erocm1231 - added range value to preferences as suggested by @Dela-Rick.
// 2015-11-26 - erocm1231 - Fixed null condition error when adding as a new device.
// 2015-11-24 - erocm1231 - Added refresh command. Made a few changes to how the handler maps colors to the LEDs. Fixed
// the device not having its on/off status updated when colors are changed.
// 2015-11-23 - erocm1231 - Changed the look to match SmartThings v2 devices.
// 2015-11-21 - erocm1231 - Made code much more efficient. Also made it compatible when setColor is passed a hex value.
// Mapping of special colors: Soft White - Default - Yellow, White - Concentrate - White,
// Daylight - Energize - Teal, Warm White - Relax - Yellow
// 2015-11-19 - erocm1231 - Fixed a couple incorrect colors, changed setColor to be more compatible with other apps
// 2015-11-18 - erocm1231 - Added to setColor for compatibility with Smart Lighting
// v0.1.0 - DrZWave - chose better icons, Got color LED to work - first fully functional version
// v0.0.9 - jrs - got the temp and luminance to work. Motion works. Debugging the color wheel.
// v0.0.8 - DrZWave 2/25/2015 - change the color control to be tiles since there are only 8 colors.
// v0.0.7 - jrs - 02/23/2015 - Jim Sulin
metadata {
definition (name: "EZmultiPli", namespace: "DrZWave", author: "Eric Ryherd", oauth: true) {
@@ -131,7 +110,6 @@ metadata {
} // end metadata
// Parse incoming device messages from device to generate events
def parse(String description){
//log.debug "==> New Zwave Event: ${description}"
@@ -145,7 +123,7 @@ def parse(String description){
def statusTextmsg = ""
if (device.currentState('temperature') != null && device.currentState('illuminance') != null) {
statusTextmsg = "${device.currentState('temperature').value} ° - ${device.currentState('illuminance').value} ${(lum == "" || lum == null || lum == 1) ? "%" : "LUX"}"
statusTextmsg = "${device.currentState('temperature').value} ° - ${device.currentState('illuminance').value} ${(lum == 1) ? "%" : "LUX"}"
sendEvent("name":"statusText", "value":statusTextmsg, displayed:false)
}
if (result != [null] && result != []) log.debug "Parse returned ${result}"
@@ -168,7 +146,7 @@ def zwaveEvent(physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelR
break;
case 0x03 : // SENSOR_TYPE_LUMINANCE_VERSION_1
map.value = cmd.scaledSensorValue.toInteger().toString()
if(lum == "" || lum == null || lum == 1) map.unit = "%"
if(lum == 1) map.unit = "%"
else map.unit = "lux"
map.name = "illuminance"
log.debug "Luminance report"
@@ -203,7 +181,8 @@ def zwaveEvent(physicalgraph.zwave.commands.notificationv3.NotificationReport cm
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
if (cmd.value == 0 && device.latestState("color").value != "#ffffff") {
// The EZMultiPli sets the color back to #ffffff on "off" or at init, so update the ST device to reflect this.
if (device.latestState("color") == null || (cmd.value == 0 && device.latestState("color").value != "#ffffff")) {
sendEvent(name: "color", value: "#ffffff", displayed: true)
}
[name: "switch", value: cmd.value ? "on" : "off", type: "digital"]
@@ -296,12 +275,12 @@ def zwaveEvent(physicalgraph.zwave.Command cmd) {
// ensure we are passing acceptable param values for LiteMin & TempMin configs
def checkLiteTempInput(value) {
if (value == null) {
value=60
value=6
}
def liteTempVal = value.toInteger()
switch (liteTempVal) {
case { it < 0 }:
return 60 // bad value, set to default
return 6 // bad value, set to default
break
case { it > 127 }:
return 127 // bad value, greater then MAX, set to MAX
@@ -314,12 +293,12 @@ def checkLiteTempInput(value) {
// ensure we are passing acceptable param value for OnTime config
def checkOnTimeInput(value) {
if (value == null) {
value=10
value=2
}
def onTimeVal = value.toInteger()
switch (onTimeVal) {
case { it < 0 }:
return 10 // bad value set to default
return 2 // bad value set to default
break
case { it > 127 }:
return 127 // bad value, greater then MAX, set to MAX

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,33 @@
# Osotech Plant Link
Cloud Execution
Works with:
* [OSO Technologies PlantLink Soil Moisture Sensor](https://www.smartthings.com/works-with-smartthings/oso-technologies/oso-technologies-plantlink-soil-moisture-sensor)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Sensor** - detects sensor events
* **Health Check** - indicates ability to get device health notifications
## Device Health
Plant Link sensor is a ZigBee sleepy device and checks in every 15 minutes.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
* __32min__ checkInterval
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the sensor is out of range.
Pairing needs to be tried again by placing the sensor closer to the hub.
Instructions related to pairing, resetting and removing the different motion sensors from SmartThings can be found in the following links
for the different models:
* [OSO Technologies PlantLink Soil Moisture Sensor Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206868986-PlantLink-Soil-Moisture-Sensor)

View File

@@ -24,6 +24,7 @@ import groovy.json.JsonBuilder
metadata {
definition (name: "PlantLink", namespace: "OsoTech", author: "Oso Technologies") {
capability "Sensor"
capability "Health Check"
command "setStatusIcon"
command "setPlantFuelLevel"
@@ -70,6 +71,16 @@ metadata {
}
}
def updated() {
// Device-Watch allows 2 check-in misses from device
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def installed() {
// Device-Watch allows 2 check-in misses from device
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def setStatusIcon(value){
def status = ''
switch (value) {
@@ -161,4 +172,4 @@ def parseDescriptionAsMap(description) {
map += []
}
}
}
}

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,50 @@
# Arrival Sensor HA (2016+ Model)
Cloud Execution
Works with:
* [Samsung SmartThings Arrival Sensor](https://support.smartthings.com/hc/en-us/articles/212417083-Samsung-SmartThings-Arrival-Sensor)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Battery](#battery)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Tone** - beep command to allow an audible tone
* **Actuator** - device has commands
* **Presence Sensor** - device tells presence with enum - {present, not present}
* **Sensor** - device has attributes
* **Battery** - defines device uses a battery
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
* **Health Check** - indicates ability to get device health notifications
## Device Health
Arrival Sensor ZigBee is an untracked device. Sends broadcast of battery level every 20 seconds.
Disconnects when Hub goes OFFLINE.
## Battery
Uses 1 CR2032 Battery
* [Changing the Battery](https://support.smartthings.com/hc/en-us/articles/200907400-How-to-change-the-battery-in-the-SmartSense-Presence-Sensor-and-Samsung-SmartThings-Arrival-Sensor)
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the arrival sensor is out of range.
Pairing needs to be tried again by placing the sensor closer to the hub.
* [Samsung SmartThings Arrival Sensor Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205382134-Samsung-SmartThings-Arrival-Sensor-2015-model-)
If the arrival sensor doesn't update its status, here are a few things you can try to debug.
* [Troubleshooting: Samsung SmartThings Arrival Sensor won't update its status](https://support.smartthings.com/hc/en-us/articles/200846514-Troubleshooting-Samsung-SmartThings-Arrival-Sensor-won-t-update-its-status)

View File

@@ -1,3 +1,5 @@
import groovy.json.JsonOutput
/**
* Copyright 2017 SmartThings
*
@@ -19,6 +21,7 @@ metadata {
capability "Sensor"
capability "Battery"
capability "Configuration"
capability "Health Check"
fingerprint inClusters: "0000,0001,0003,000F,0020", outClusters: "0003,0019",
manufacturer: "SmartThings", model: "tagv4", deviceJoinName: "Arrival Sensor"
@@ -58,6 +61,11 @@ def updated() {
startTimer()
}
def installed() {
// Arrival sensors only goes OFFLINE when Hub is off
sendEvent(name: "DeviceWatch-Enroll", value: JsonOutput.toJson([protocol: "zigbee", scheme:"untracked"]), displayed: false)
}
def configure() {
def cmds = zigbee.readAttribute(zigbee.POWER_CONFIGURATION_CLUSTER, 0x0020) + zigbee.batteryConfig(20, 20, 0x01)
log.debug "configure -- cmds: ${cmds}"

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,49 @@
# Arrival Sensor (2015 Model)
Cloud Execution
Works with:
* [Arrival Sensor](https://www.smartthings.com/products/samsung-smartthings-arrival-sensor)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Battery](#battery)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Tone** - beep command to allow an audible tone
* **Actuator** - device has commands
* **Signal Strength** - device can read the strength of signal- lqi: Link Quality Indication, rssi: Received Signal Strength Indication
* **Presence Sensor** - device tells presence with enum - {present, not present}
* **Sensor** - device has attributes
* **Battery** - defines device uses a battery
* **Health Check** - indicates ability to get device health notifications
## Device Health
Arrival Sensor ZigBee is an untracked device. Disconnects when Hub goes OFFLINE.
## Battery
Uses 1 CR2032 Battery
* [Changing the Battery](https://support.smartthings.com/hc/en-us/articles/200907400-How-to-change-the-battery-in-the-SmartSense-Presence-Sensor-and-Samsung-SmartThings-Arrival-Sensor)
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the arrival sensor is out of range.
Pairing needs to be tried again by placing the sensor closer to the hub.
* [Samsung SmartThings Arrival Sensor Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205382134-Samsung-SmartThings-Arrival-Sensor-2015-model-)
If the arrival sensor doesn't update its status, here are a few things you can try to debug.
* [Troubleshooting: Samsung SmartThings Arrival Sensor won't update its status](https://support.smartthings.com/hc/en-us/articles/200846514-Troubleshooting-Samsung-SmartThings-Arrival-Sensor-won-t-update-its-status)

View File

@@ -1,3 +1,5 @@
import groovy.json.JsonOutput
/**
* Copyright 2015 SmartThings
*
@@ -19,6 +21,7 @@ metadata {
capability "Presence Sensor"
capability "Sensor"
capability "Battery"
capability "Health Check"
fingerprint profileId: "FC01", deviceId: "019A"
fingerprint profileId: "FC01", deviceId: "0131", inClusters: "0000,0003", outClusters: "0003"
@@ -111,6 +114,11 @@ def beep() {
]
}
def installed() {
// Arrival sensors only goes OFFLINE when Hub is off
sendEvent(name: "DeviceWatch-Enroll", value: JsonOutput.toJson([protocol: "zigbee", scheme:"untracked"]), displayed: false)
}
def parse(String description) {
def results
if (isBatteryMessage(description)) {

View File

@@ -12,7 +12,7 @@
*
*/
metadata {
definition (name: "Dimmer Switch", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Dimmer Switch", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.light") {
capability "Switch Level"
capability "Actuator"
capability "Indicator"

View File

@@ -21,7 +21,7 @@ Works with:
## Device Health
Plant Link sensor is a Z-wave sleepy device and checks in every 15 minutes.
Plant Link sensor is a ZigBee sleepy device and checks in every 15 minutes.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
* __32min__ checkInterval

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,39 @@
# Smartalert Siren
Cloud Execution
Works with:
* [FortrezZ Siren Strobe Alarm](https://www.smartthings.com/works-with-smartthings/other/fortrezz-water-valve)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Switch** - can detect state (possible values: on/off)
* **Sensor** - detects sensor events
* **Alarm** - allows for interacting with devices that serve as alarms
* **Health Check** - indicates ability to get device health notifications
## Device Health
FortrezZ Siren Strobe Alarm is polled by the hub.
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
* __32min__ checkInterval
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [FortrezZ Siren Strobe Alarm Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202294760-FortrezZ-Siren-Strobe-Alarm)

View File

@@ -21,10 +21,12 @@ metadata {
capability "Switch"
capability "Sensor"
capability "Alarm"
capability "Health Check"
command "test"
fingerprint deviceId: "0x1100", inClusters: "0x26,0x71"
fingerprint mfr:"0084", prod:"0313", model:"010B", deviceJoinName: "FortrezZ Siren Strobe Alarm"
}
simulator {
@@ -68,6 +70,16 @@ metadata {
}
}
def installed() {
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
def updated() {
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
def on() {
[
zwave.basicV1.basicSet(value: 0xFF).format(),
@@ -149,3 +161,10 @@ def createEvents(physicalgraph.zwave.commands.basicv1.BasicReport cmd)
def zwaveEvent(physicalgraph.zwave.Command cmd) {
log.warn "UNEXPECTED COMMAND: $cmd"
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
secure(zwave.basicV1.basicGet())
}

View File

@@ -33,7 +33,6 @@ metadata {
fingerprint inClusters: "0000,0001,0003,0402,0500,0020,0B05,FC02", outClusters: "0019", manufacturer: "CentraLite", model: "3320"
fingerprint inClusters: "0000,0001,0003,0402,0500,0020,0B05,FC02", outClusters: "0019", manufacturer: "CentraLite", model: "3321"
fingerprint inClusters: "0000,0001,0003,0402,0500,0020,0B05,FC02", outClusters: "0019", manufacturer: "CentraLite", model: "3321-S", deviceJoinName: "Multipurpose Sensor"
fingerprint inClusters: "0000,0001,0003,0020,0402,0500,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3323-G", deviceJoinName: "Centralite Micro Door Sensor"
fingerprint inClusters: "0000,0001,0003,000F,0020,0402,0500,FC02", outClusters: "0019", manufacturer: "SmartThings", model: "multiv4", deviceJoinName: "Multipurpose Sensor"
attribute "status", "string"
@@ -192,6 +191,10 @@ private List<Map> parseAxis(List<Map> attrData) {
def y = hexToSignedInt(attrData.find { it.attrInt == 0x0013 }?.value)
def z = hexToSignedInt(attrData.find { it.attrInt == 0x0014 }?.value)
if ([x, y ,z].any { it == null }) {
return []
}
def xyzResults = [:]
if (device.getDataValue("manufacturer") == "SmartThings") {
// This mapping matches the current behavior of the Device Handler for the Centralite sensors
@@ -372,6 +375,10 @@ def updated() {
}
private hexToSignedInt(hexVal) {
if (!hexVal) {
return null
}
def unsignedVal = hexToInt(hexVal)
unsignedVal > 32767 ? unsignedVal - 65536 : unsignedVal
}

View File

@@ -31,6 +31,7 @@ metadata {
fingerprint inClusters: "0000,0001,0003,0402,0500,0020,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3300-S"
fingerprint inClusters: "0000,0001,0003,0402,0500,0020,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3300"
fingerprint inClusters: "0000,0001,0003,0020,0402,0500,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3320-L", deviceJoinName: "Iris Contact Sensor"
fingerprint inClusters: "0000,0001,0003,0020,0402,0500,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3323-G", deviceJoinName: "Centralite Micro Door Sensor"
}
simulator {

View File

@@ -70,19 +70,27 @@ def parse(String description) {
else {
sendEvent(event)
}
}
else {
def cluster = zigbee.parse(description)
if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07) {
if (cluster.data[0] == 0x00){
} else {
def descMap = zigbee.parseDescriptionAsMap(description)
if (descMap && descMap.clusterInt == 0x0006 && descMap.commandInt == 0x07) {
if (descMap.data[0] == "00") {
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
else {
} else {
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
}
}
else {
} else if (device.getDataValue("manufacturer") == "sengled" && descMap && descMap.clusterInt == 0x0008 && descMap.attrInt == 0x0000) {
// This is being done because the sengled element touch incorrectly uses the value 0xFF for the max level.
// Per the ZCL spec for the UINT8 data type 0xFF is an invalid value, and 0xFE should be the max. Here we
// manually handle the invalid attribute value since it will be ignored by getEvent as an invalid value.
// We also set the level of the bulb to 0xFE so future level reports will be 0xFE until it is changed by
// something else.
if (descMap.value.toUpperCase() == "FF") {
descMap.value = "FE"
}
sendHubCommand(zigbee.command(zigbee.LEVEL_CONTROL_CLUSTER, 0x00, "FE0000").collect { new physicalgraph.device.HubAction(it) }, 0)
sendEvent(zigbee.getEventFromAttrData(descMap.clusterInt, descMap.attrInt, descMap.encoding, descMap.value))
} else {
log.warn "DID NOT PARSE MESSAGE for description : $description"
log.debug zigbee.parseDescriptionAsMap(description)
}

View File

@@ -1,4 +1,4 @@
# Z-Wave Switch
# Z-Wave Lock
Cloud Execution
@@ -6,7 +6,6 @@ Works with:
* [Yale Key Free Touchscreen Deadbolt (YRD240)](https://www.smartthings.com/works-with-smartthings/yale/yale-key-free-touchscreen-deadbolt-yrd240)
## Table of contents
* [Capabilities](#capabilities)
@@ -41,5 +40,3 @@ If the device doesn't pair when trying from the SmartThings mobile app, it is po
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [General Z-Wave/ZigBee Yale Lock Troubleshooting](https://support.smartthings.com/hc/en-us/articles/205138400-How-to-connect-Yale-locks)

View File

@@ -16,7 +16,7 @@
*
*/
metadata {
definition (name: "Z-Wave Metering Dimmer", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Z-Wave Metering Dimmer", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.light") {
capability "Switch"
capability "Polling"
capability "Power Meter"

View File

@@ -136,10 +136,20 @@ def getDataForChild(child, startDate, endDate) {
def wattvisionURL = wattvisionURL(child.deviceNetworkId, startDate, endDate)
if (wattvisionURL) {
httpGet(uri: wattvisionURL) { response ->
def json = new org.json.JSONObject(response.data.toString())
child.addWattvisionData(json)
return "success"
try {
httpGet(uri: wattvisionURL) { response ->
def json = new org.json.JSONObject(response.data.toString())
child.addWattvisionData(json)
return "success"
}
} catch (groovyx.net.http.HttpResponseException httpE) {
log.error "Wattvision getDataForChild HttpResponseException: ${httpE} -> ${httpE.response.data}"
//log.debug "wattvisionURL = ${wattvisionURL}"
return "fail"
} catch (e) {
log.error "Wattvision getDataForChild General Exception: ${e}"
//log.debug "wattvisionURL = ${wattvisionURL}"
return "fail"
}
}
}
@@ -164,9 +174,14 @@ def wattvisionURL(senorId, startDate, endDate) {
if (diff > 259200000) { // 3 days in milliseconds
// Wattvision only allows pulling 3 hours of data at a time
startDate = new Date(hours: endDate.hours - 3)
} else if (diff < 10000) { // 10 seconds in milliseconds
// Wattvision throws errors when the difference between start_time and end_time is 5 seconds or less
// So we are going to make sure that we have a few more seconds of breathing room
use (groovy.time.TimeCategory) {
startDate = endDate - 10.seconds
}
}
def params = [
"sensor_id" : senorId,
"api_id" : wattvisionApiAccess.id,
@@ -480,4 +495,3 @@ def connectionSuccessful(deviceName, iconSrc) {
render contentType: 'text/html', data: html
}