mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-11 13:21:51 +00:00
Compare commits
18 Commits
MSA-1951-1
...
PROD_2017.
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
b645872d8f | ||
|
|
d3731b49fe | ||
|
|
da139056e1 | ||
|
|
d864c5e3b3 | ||
|
|
7064ce972a | ||
|
|
936ee59242 | ||
|
|
79a6a6472e | ||
|
|
919111ed22 | ||
|
|
fc1f1508ad | ||
|
|
7f3cd0cdaa | ||
|
|
423c25df53 | ||
|
|
df8e435fcc | ||
|
|
144314d9ae | ||
|
|
8eed22ca0c | ||
|
|
d626c5f2a1 | ||
|
|
1dae5d3936 | ||
|
|
807ff53c6d | ||
|
|
453dbbdde3 |
2
devicetypes/smartthings/aeon-multisensor.src/.st-ignore
Normal file
2
devicetypes/smartthings/aeon-multisensor.src/.st-ignore
Normal file
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
48
devicetypes/smartthings/aeon-multisensor.src/README.md
Normal file
48
devicetypes/smartthings/aeon-multisensor.src/README.md
Normal file
@@ -0,0 +1,48 @@
|
||||
# Aeon Multisensor
|
||||
|
||||
Cloud Execution
|
||||
|
||||
Works with:
|
||||
|
||||
* [Aeotec MultiSensor (DSB05-ZWUS)](https://www.smartthings.com/products/aeotec-multisensor-5)
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
* [Battery](#battery-specification)
|
||||
* [Troubleshooting](#troubleshooting)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Motion Sensor** - can detect motion
|
||||
* **Temperature Measurement** - defines device measures current temperature
|
||||
* **Relative Humidity Measurement** - allow reading the relative humidity from devices that support it
|
||||
* **Illuminance Measurement** - gives the illuminance reading from devices that support it
|
||||
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
|
||||
* **Sensor** - detects sensor events
|
||||
* **Battery** - defines device uses a battery
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
|
||||
|
||||
## Device Health
|
||||
|
||||
Aeon Labs MultiSensor is polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
* __32min__ checkInterval
|
||||
|
||||
## Battery Specification
|
||||
|
||||
Four AAA batteries are required.
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [Aeon MultiSensor Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206157226-How-to-connect-Aeon-Labs-MultiSensors)
|
||||
@@ -20,6 +20,7 @@ metadata {
|
||||
capability "Illuminance Measurement"
|
||||
capability "Sensor"
|
||||
capability "Battery"
|
||||
capability "Health Check"
|
||||
|
||||
fingerprint deviceId: "0x2001", inClusters: "0x30,0x31,0x80,0x84,0x70,0x85,0x72,0x86"
|
||||
}
|
||||
@@ -93,6 +94,16 @@ metadata {
|
||||
}
|
||||
}
|
||||
|
||||
def installed(){
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
|
||||
// Parse incoming device messages to generate events
|
||||
def parse(String description)
|
||||
{
|
||||
@@ -179,6 +190,13 @@ def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
[:]
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
secure(zwave.batteryV1.batteryGet())
|
||||
}
|
||||
|
||||
def configure() {
|
||||
delayBetween([
|
||||
// send binary sensor report instead of basic set for motion
|
||||
|
||||
@@ -61,6 +61,8 @@ metadata {
|
||||
def installed() {
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
response(secure(zwave.basicV1.basicGet()))
|
||||
}
|
||||
|
||||
def updated() {
|
||||
@@ -163,4 +165,4 @@ private secure(physicalgraph.zwave.Command cmd) {
|
||||
* */
|
||||
def ping() {
|
||||
secure(zwave.basicV1.basicGet())
|
||||
}
|
||||
}
|
||||
|
||||
@@ -16,7 +16,7 @@
|
||||
* Date: 2013-03-05
|
||||
*/
|
||||
metadata {
|
||||
definition (name: "SmartAlert Siren", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "x.com.st.smokedetector") {
|
||||
definition (name: "SmartAlert Siren", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "x.com.st.d.sensor.smoke") {
|
||||
capability "Actuator"
|
||||
capability "Switch"
|
||||
capability "Sensor"
|
||||
|
||||
@@ -113,9 +113,9 @@ def updated() {
|
||||
|
||||
def configure() {
|
||||
commands([
|
||||
zwave.manufacturerSpecificV2.manufacturerSpecificGet(),
|
||||
zwave.batteryV1.batteryGet()
|
||||
], 6000)
|
||||
zwave.sensorBinaryV2.sensorBinaryGet(sensorType: zwave.sensorBinaryV2.SENSOR_TYPE_DOOR_WINDOW),
|
||||
zwave.manufacturerSpecificV2.manufacturerSpecificGet()
|
||||
], 1000)
|
||||
}
|
||||
|
||||
def sensorValueEvent(value) {
|
||||
@@ -190,11 +190,17 @@ def zwaveEvent(physicalgraph.zwave.commands.wakeupv1.WakeUpNotification cmd)
|
||||
cmds << command(zwave.manufacturerSpecificV2.manufacturerSpecificGet())
|
||||
cmds << "delay 1200"
|
||||
}
|
||||
|
||||
if (device.currentValue("contact") == null) { // Incase our initial request didn't make it
|
||||
cmds << command(zwave.sensorBinaryV2.sensorBinaryGet(sensorType: zwave.sensorBinaryV2.SENSOR_TYPE_DOOR_WINDOW))
|
||||
}
|
||||
|
||||
if (!state.lastbat || now() - state.lastbat > 53*60*60*1000) {
|
||||
cmds << command(zwave.batteryV1.batteryGet())
|
||||
} else {
|
||||
} else { // If we check the battery state we will send NoMoreInfo in the handler for BatteryReport so that we definitely get the report
|
||||
cmds << zwave.wakeUpV1.wakeUpNoMoreInformation().format()
|
||||
}
|
||||
|
||||
[event, response(cmds)]
|
||||
}
|
||||
|
||||
|
||||
@@ -86,13 +86,13 @@ import physicalgraph.zwave.commands.doorlockv1.*
|
||||
import physicalgraph.zwave.commands.usercodev1.*
|
||||
|
||||
def installed() {
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
// Device-Watch pings if no device events received for 1 hour (checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 1 * 60 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
|
||||
def updated() {
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
// Device-Watch pings if no device events received for 1 hour (checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 1 * 60 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
try {
|
||||
if (!state.init) {
|
||||
state.init = true
|
||||
@@ -152,6 +152,10 @@ def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityCommandsSupported
|
||||
|
||||
def zwaveEvent(DoorLockOperationReport cmd) {
|
||||
def result = []
|
||||
|
||||
unschedule("followupStateCheck")
|
||||
unschedule("stateCheck")
|
||||
|
||||
def map = [ name: "lock" ]
|
||||
if (cmd.doorLockMode == 0xFF) {
|
||||
map.value = "locked"
|
||||
@@ -365,7 +369,7 @@ def zwaveEvent(UserCodeReport cmd) {
|
||||
code = state["set$name"] ?: decrypt(state[name]) ?: "****"
|
||||
state.remove("set$name".toString())
|
||||
} else {
|
||||
map = [ name: "codeReport", value: cmd.userIdentifier, data: [ code: code ] ]
|
||||
map = [ name: "codeReport", value: cmd.userIdentifier, data: [ code: code ], isStateChange: true ]
|
||||
map.descriptionText = "$device.displayName code $cmd.userIdentifier is set"
|
||||
map.displayed = (cmd.userIdentifier != state.requestCode && cmd.userIdentifier != state.pollCode)
|
||||
map.isStateChange = true
|
||||
@@ -456,11 +460,12 @@ def zwaveEvent(physicalgraph.zwave.commands.timev1.TimeGet cmd) {
|
||||
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd) {
|
||||
// The old Schlage locks use group 1 for basic control - we don't want that, so unsubscribe from group 1
|
||||
def result = [ createEvent(name: "lock", value: cmd.value ? "unlocked" : "locked") ]
|
||||
result << response(zwave.associationV1.associationRemove(groupingIdentifier:1, nodeId:zwaveHubNodeId))
|
||||
if (state.assoc != zwaveHubNodeId) {
|
||||
result << response(zwave.associationV1.associationGet(groupingIdentifier:2))
|
||||
}
|
||||
result
|
||||
def cmds = [
|
||||
zwave.associationV1.associationRemove(groupingIdentifier:1, nodeId:zwaveHubNodeId).format(),
|
||||
"delay 1200",
|
||||
zwave.associationV1.associationGet(groupingIdentifier:2).format()
|
||||
]
|
||||
[result, response(cmds)]
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
|
||||
@@ -530,11 +535,18 @@ def unlockwtimeout() {
|
||||
lockAndCheck(DoorLockOperationSet.DOOR_LOCK_MODE_DOOR_UNSECURED_WITH_TIMEOUT)
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
refresh()
|
||||
runIn(30, followupStateCheck)
|
||||
secure(zwave.doorLockV1.doorLockOperationGet())
|
||||
}
|
||||
|
||||
def followupStateCheck() {
|
||||
runEvery1Hour(stateCheck)
|
||||
stateCheck()
|
||||
}
|
||||
|
||||
def stateCheck() {
|
||||
sendHubCommand(new physicalgraph.device.HubAction(secure(zwave.doorLockV1.doorLockOperationGet())))
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
|
||||
@@ -16,7 +16,7 @@
|
||||
* Date: 2014-07-15
|
||||
*/
|
||||
metadata {
|
||||
definition (name: "Z-Wave Siren", namespace: "smartthings", author: "SmartThings") {
|
||||
definition (name: "Z-Wave Siren", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "x.com.st.d.sensor.smoke") {
|
||||
capability "Actuator"
|
||||
capability "Alarm"
|
||||
capability "Battery"
|
||||
|
||||
Reference in New Issue
Block a user