Compare commits

..

1 Commits

Author SHA1 Message Date
David Wang 11a8996931 MSA-1867: LINGAN RGBW Buid Device Handlers 2017-03-31 02:28:38 -07:00
26 changed files with 113 additions and 226 deletions
@@ -1,2 +0,0 @@
.st-ignore
README.md
@@ -1,41 +0,0 @@
# Fibaro Door Window Sensor ZW5
Cloud Execution
Works with:
* [Fibaro Door/Window Sensor ZW5](https://www.smartthings.com/works-with-smartthings/sensors/fibaro-doorwindow-sensor)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Battery](#battery-specification)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Battery** - defines device uses a battery
* **Contact Sensor** - can detect contact (possible values: open,closed)
* **Sensor** - detects sensor events
* **Tamper Alert** - detects tampers
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
* **Health Check** - indicates ability to get device health notifications
## Device Health
Fibaro Door/Window Sensor ZW5 is a Z-wave sleepy device and wakes up every 4 hours.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*4*60 + 2)mins = 482 mins.
* __482min__ checkInterval
## Battery Specification
One 1/2AA 3.6V battery is required.
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [Fibaro Door/Window Sensor ZW5 Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/204075194-Fibaro-Door-Window-Sensor)
@@ -20,7 +20,6 @@ metadata {
capability "Sensor"
capability "Configuration"
capability "Tamper Alert"
capability "Health Check"
fingerprint deviceId: "0x0701", inClusters: "0x5E, 0x85, 0x59, 0x22, 0x20, 0x80, 0x70, 0x56, 0x5A, 0x7A, 0x72, 0x8E, 0x71, 0x73, 0x98, 0x2B, 0x9C, 0x30, 0x86, 0x84", outClusters: ""
}
@@ -200,9 +199,7 @@ def zwaveEvent(physicalgraph.zwave.commands.deviceresetlocallyv1.DeviceResetLoca
def configure() {
log.debug "Executing 'configure'"
// Device wakes up every 4 hours, this interval allows us to miss one wakeup notification before marking offline
sendEvent(name: "checkInterval", value: 8 * 60 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
def cmds = []
cmds += zwave.wakeUpV2.wakeUpIntervalSet(seconds:21600, nodeid: zwaveHubNodeId)//FGK's default wake up interval
@@ -12,7 +12,7 @@
*
*/
metadata {
definition (name: "Dimmer Switch", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Dimmer Switch", namespace: "smartthings", author: "SmartThings") {
capability "Switch Level"
capability "Actuator"
capability "Indicator"
@@ -43,8 +43,8 @@ metadata {
}
tiles {
standardTile("temperature", "device.temperature", width: 2, height: 2, decoration: "flat") {
state("temperature", label:'${currentValue}°', unit:"F", icon: "st.thermostat.ac.air-conditioning",
valueTile("temperature", "device.temperature", width: 2, height: 2) {
state("temperature", label:'${currentValue}°', unit:"F",
backgroundColors:[
// Celsius
[value: 0, color: "#153591"],
@@ -70,7 +70,7 @@ metadata {
state "heat", action:"switchMode", nextState: "updating", icon: "st.thermostat.heat"
state "cool", action:"switchMode", nextState: "updating", icon: "st.thermostat.cool"
state "auto", action:"switchMode", nextState: "updating", icon: "st.thermostat.auto"
state "emergency heat", action:"switchMode", icon: "st.thermostat.emergency-heat" // emergency heat = auxHeatOnly
state "emergency heat", label:"auxHeatOnly", action:"switchMode", icon: "st.thermostat.emergency-heat" // emergency heat = auxHeatOnly
state "updating", label:"Working", icon: "st.secondary.secondary"
}
standardTile("fanMode", "device.thermostatFanMode", inactiveLabel: false, decoration: "flat") {
@@ -185,11 +185,6 @@ def generateEvent(Map results) {
isChange = isStateChange(device, name, value.toString())
event['isStateChange'] = isChange
event['displayed'] = false
} else if (name == "thermostatMode") {
def mode = value.toString()
mode = (mode == "auxHeatOnly") ? "emergency heat" : mode
isChange = isStateChange(device, name, mode)
event << [value: mode, isStateChange: isChange, displayed: isDisplayed]
} else {
isChange = isStateChange(device, name, value.toString())
isDisplayed = isChange
@@ -1,2 +0,0 @@
.st-ignore
README.md
@@ -1,40 +0,0 @@
# Everspring Flood Sensor
Cloud Execution
Works with:
* [Everspring Water Detector](https://www.smartthings.com/works-with-smartthings/sensors/everspring-water-detector)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Battery](#battery-specification)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Water Sensor** - can detect presence of water (dry or wet)
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
* **Sensor** - detects sensor events
* **Battery** - defines device uses a battery
* **Health Check** - indicates ability to get device health notifications
## Device Health
Everspring Water Detector is a Z-wave sleepy device and wakes up every 4 hours.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*4*60 + 2)mins = 482 mins.
* __482min__ checkInterval
## Battery Specification
Three AA 1.5V batteries are required.
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [Everspring Water Detector Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202088304-Everspring-Water-Detector)
@@ -17,7 +17,6 @@ metadata {
capability "Configuration"
capability "Sensor"
capability "Battery"
capability "Health Check"
fingerprint deviceId: "0xA102", inClusters: "0x86,0x72,0x85,0x84,0x80,0x70,0x9C,0x20,0x71"
}
@@ -139,8 +138,6 @@ def zwaveEvent(physicalgraph.zwave.Command cmd)
def configure()
{
// Device wakes up every 4 hours, this interval allows us to miss one wakeup notification before marking offline
sendEvent(name: "checkInterval", value: 8 * 60 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
if (!device.currentState("battery")) {
sendEvent(name: "battery", value:100, unit:"%", descriptionText:"(Default battery event)", displayed:false)
}
@@ -20,7 +20,6 @@ metadata {
definition(name: "Wattvision", namespace: "smartthings", author: "Steve Vlaminck") {
capability "Power Meter"
capability "Refresh"
capability "Sensor"
attribute "powerContent", "string"
}
@@ -18,7 +18,7 @@
metadata {
definition (name: "Wemo Light Switch", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Wemo Light Switch", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Switch"
capability "Polling"
@@ -16,7 +16,7 @@
* Date: 2015-10-11
*/
metadata {
definition (name: "Wemo Switch", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.smartplug") {
definition (name: "Wemo Switch", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Switch"
capability "Polling"
@@ -13,7 +13,7 @@
*/
metadata {
definition (name: "ZigBee Dimmer", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "ZigBee Dimmer", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Configuration"
capability "Refresh"
@@ -1,46 +0,0 @@
# Zigbee Lock
Cloud Execution
Works with:
* [Yale Push Button Deadbolt (YRD210-HA)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-push-button-deadbolt-yrd210)
* [Yale Touchscreen Lever (YRL220-ZB)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-touchscreen-lever-yrl220)
* [Yale Touchscreen Deadbolt (YRD220-HA))](https://www.smartthings.com/works-with-smartthings/door-locks/yale-touchscreen-deadbolt-yrd220)
* [Yale Key Free Touchscreen Deadbolt (YRD240-HA)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-key-free-touchscreen-deadbolt-yrd240)
* [Yale Push Button Lever Lock (YRL210-HA)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-push-button-lever-lock-yrl210)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Battery](#battery-specification)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Lock** - allows for the control of a lock device
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - detects sensor events
* **Battery** - defines device uses a battery
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
* **Health Check** - indicates ability to get device health notifications
## Device Health
Yale Push Button Deadbolt (YRD210-HA) is a Zigbee device and checks in every 1 hour.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*60 + 2)mins = 122 mins.
* __122min__ checkInterval
## Battery Specification
Four AA 1.5V batteries are required.
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the sensor from SmartThings can be found in the following link:
* [Yale Locks Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205138400)
@@ -24,7 +24,6 @@ import physicalgraph.zigbee.zcl.DataType
capability "Sensor"
capability "Battery"
capability "Configuration"
capability "Health Check"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0004,0005,0009,0020,0101,0402,0B05,FDBD", outClusters: "000A,0019", manufacturer: "Kwikset", model: "SMARTCODE_DEADBOLT_5", deviceJoinName: "Kwikset 5-Button Deadbolt"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0004,0005,0009,0020,0101,0402,0B05,FDBD", outClusters: "000A,0019", manufacturer: "Kwikset", model: "SMARTCODE_LEVER_5", deviceJoinName: "Kwikset 5-Button Lever"
@@ -84,9 +83,6 @@ def uninstalled() {
}
def configure() {
// Device-Watch allows 2 check-in misses from device + ping (plus 2 min lag time)
sendEvent(name: "checkInterval", value: 2 * 60 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
def cmds =
zigbee.configureReporting(CLUSTER_DOORLOCK, DOORLOCK_ATTR_LOCKSTATE,
DataType.ENUM8, 0, 3600, null) +
@@ -96,13 +92,6 @@ def configure() {
return refresh() + cmds // send refresh cmds as part of config
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
zigbee.readAttribute(CLUSTER_DOORLOCK, DOORLOCK_ATTR_LOCKSTATE)
}
def refresh() {
def cmds =
zigbee.readAttribute(CLUSTER_DOORLOCK, DOORLOCK_ATTR_LOCKSTATE) +
@@ -40,6 +40,7 @@ metadata {
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY BR RGBW", deviceJoinName: "SYLVANIA Smart BR30 RGBW"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY RT RGBW", deviceJoinName: "SYLVANIA Smart RT5/6 RGBW"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY FLEX OUTDOOR RGBW", deviceJoinName: "SYLVANIA Smart Outdoor RGBW Flex"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0300", outClusters: "0000, 0003, 0006", manufacturer: "LINGAN", model: "LIGHTIFY A01 RGBW", deviceJoinName: "LINGAN LIGHTIFY LED Smart Connected Light"
}
// UI tile definitions
@@ -25,7 +25,6 @@ metadata {
capability "Refresh"
capability "Actuator"
capability "Sensor"
capability "Configuration"
fingerprint manufacturer: "015D", prod: "0651", model: "F51C", deviceJoinName: "Zooz ZEN 20 Power Strip"
}
@@ -66,10 +65,6 @@ def updated() {
}
}
def configure() {
refresh()
}
//////////////////////
// Event Generation //
@@ -112,17 +107,15 @@ def zwaveBinaryEvent(cmd, endpoint) {
def result = []
def children = childDevices
def childDevice = children.find{it.deviceNetworkId.endsWith("$endpoint")}
if (childDevice) {
childDevice.sendEvent(name: "switch", value: cmd.value ? "on" : "off")
childDevice.sendEvent(name: "switch", value: cmd.value ? "on" : "off")
if (cmd.value) {
// One on and the strip is on
result << createEvent(name: "switch", value: "on")
} else {
// All off and the strip is off
if (!children.any { it.currentValue("switch") == "on" }) {
result << createEvent(name: "switch", value: "off")
}
if (cmd.value) {
// One on and the strip is on
result << createEvent(name: "switch", value: "on")
} else {
// All off and the strip is off
if (! children.any { it.currentValue("switch") == "on" }) {
result << createEvent(name: "switch", value: "off")
}
}
result
@@ -12,7 +12,7 @@
*
*/
metadata {
definition (name: "Z-Wave Dimmer Switch Generic", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Z-Wave Dimmer Switch Generic", namespace: "smartthings", author: "SmartThings") {
capability "Switch Level"
capability "Actuator"
capability "Health Check"
@@ -16,7 +16,7 @@
*
*/
metadata {
definition (name: "Z-Wave Metering Dimmer", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Z-Wave Metering Dimmer", namespace: "smartthings", author: "SmartThings") {
capability "Switch"
capability "Polling"
capability "Power Meter"
@@ -12,7 +12,7 @@
*
*/
metadata {
definition (name: "Z-Wave Metering Switch", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Z-Wave Metering Switch", namespace: "smartthings", author: "SmartThings") {
capability "Energy Meter"
capability "Actuator"
capability "Switch"
@@ -27,7 +27,7 @@ metadata {
command "reset"
fingerprint inClusters: "0x25,0x32"
fingerprint mfr:"0086", prod:"0003", model:"0012", deviceJoinName: "Aeon Labs Micro Smart Switch"
fingerprint mfr:"0086", prod:"0003", model:"0012", deviceJoinName: "Aeon Labs Micro Smart Switch 2E"
}
// simulator metadata
@@ -86,7 +86,7 @@ def updated() {
def parse(String description) {
def result = null
if(description == "updated") return
if(description == "updated") return
def cmd = zwave.parse(description, [0x20: 1, 0x32: 1, 0x72: 2])
if (cmd) {
result = zwaveEvent(cmd)
@@ -0,0 +1,42 @@
# Z-wave Siren
Cloud Execution
Works with:
* [FortrezZ Siren Strobe Alarm](https://www.smartthings.com/works-with-smartthings/other/fortrezz-water-valve)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Alarm** - allows for interacting with devices that serve as alarms
* **Battery** - defines device uses a battery
* **Health Check** - indicates ability to get device health notifications
* **Polling** - represents that poll() can be implemented for the device
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - detects sensor events
* **Switch** - can detect state (possible values: on/off)
## Device Health
FortrezZ Siren Strobe Alarm is polled by the hub.
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
* __32min__ checkInterval
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [FortrezZ Siren Strobe Alarm Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202294760-FortrezZ-Siren-Strobe-Alarm)
@@ -20,6 +20,7 @@ metadata {
capability "Actuator"
capability "Alarm"
capability "Battery"
capability "Health Check"
capability "Polling"
capability "Refresh"
capability "Sensor"
@@ -27,6 +28,7 @@ metadata {
fingerprint inClusters: "0x20,0x25,0x86,0x80,0x85,0x72,0x71"
fingerprint mfr:"0084", prod:"0313", model:"010B", deviceJoinName: "FortrezZ Siren Strobe Alarm"
}
simulator {
@@ -58,6 +60,11 @@ metadata {
}
}
def updated(){
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
def createEvents(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def map = [ name: "battery", unit: "%" ]
if (cmd.batteryLevel == 0xFF) {
@@ -119,6 +126,13 @@ def both() {
on()
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
refresh()
}
def refresh() {
log.debug "sending battery refresh command"
zwave.batteryV1.batteryGet().format()
@@ -12,7 +12,7 @@
*
*/
metadata {
definition (name: "Z-Wave Switch Generic", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Z-Wave Switch Generic", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Health Check"
capability "Switch"
@@ -12,7 +12,7 @@
*
*/
metadata {
definition (name: "Z-Wave Switch Secure", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Z-Wave Switch Secure", namespace: "smartthings", author: "SmartThings") {
capability "Switch"
capability "Refresh"
capability "Polling"
@@ -12,7 +12,7 @@
*
*/
metadata {
definition (name: "Z-Wave Switch", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "oic.d.switch") {
definition (name: "Z-Wave Switch", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Indicator"
capability "Switch"
@@ -42,9 +42,9 @@ metadata {
status "auto" : "command: 4003, payload: 03"
status "emergencyHeat" : "command: 4003, payload: 04"
status "auto" : "command: 4403, payload: 00" // "fanAuto"
status "on" : "command: 4403, payload: 01" // "fanOn"
status "circulate" : "command: 4403, payload: 06" // "fanCirculate
status "fanAuto" : "command: 4403, payload: 00"
status "fanOn" : "command: 4403, payload: 01"
status "fanCirculate" : "command: 4403, payload: 06"
status "heat 60" : "command: 4303, payload: 01 09 3C"
status "heat 68" : "command: 4303, payload: 01 09 44"
@@ -74,9 +74,8 @@ metadata {
}
tiles {
// Using standardTile instead of valueTile as it renders the icon better
standardTile("temperature", "device.temperature", width: 2, height: 2) {
state("temperature", label:'${currentValue}°', icon: "st.thermostat.ac.air-conditioning",
valueTile("temperature", "device.temperature", width: 2, height: 2) {
state("temperature", label:'${currentValue}°',
backgroundColors:[
[value: 31, color: "#153591"],
[value: 44, color: "#1e9cbb"],
@@ -89,20 +88,19 @@ metadata {
)
}
standardTile("mode", "device.thermostatMode", inactiveLabel: false, decoration: "flat") {
state "off", action:"switchMode", nextState:"to_heat", icon: "st.thermostat.heating-cooling-off"
state "heat", action:"switchMode", nextState:"to_cool", icon: "st.thermostat.heat"
state "cool", action:"switchMode", nextState:"...", icon: "st.thermostat.cool"
state "auto", action:"switchMode", nextState:"...", icon: "st.thermostat.auto"
state "emergency heat", action:"switchMode", nextState:"...", icon: "st.thermostat.emergency-heat"
state "to_heat", action:"switchMode", nextState:"to_cool", icon: "st.thermostat.heat"
state "to_cool", action:"switchMode", nextState:"...", icon: "st.thermostat.cool"
state "off", label:'${name}', action:"switchMode", nextState:"to_heat"
state "heat", label:'${name}', action:"switchMode", nextState:"to_cool"
state "cool", label:'${name}', action:"switchMode", nextState:"..."
state "auto", label:'${name}', action:"switchMode", nextState:"..."
state "emergency heat", label:'${name}', action:"switchMode", nextState:"..."
state "to_heat", label: "heat", action:"switchMode", nextState:"to_cool"
state "to_cool", label: "cool", action:"switchMode", nextState:"..."
state "...", label: "...", action:"off", nextState:"off"
}
standardTile("fanMode", "device.thermostatFanMode", inactiveLabel: false, decoration: "flat") {
state "auto", action:"switchFanMode", nextState:"...", icon: "st.thermostat.fan-auto" // "fanAuto"
state "on", action:"switchFanMode", nextState:"...", icon: "st.thermostat.fan-on" // "fanOn"
state "circulate", action:"switchFanMode", nextState:"...", icon: "st.thermostat.fan-circulate" // "fanCirculate"
state "...", label: "...", nextState:"..."
state "fanAuto", label:'${name}', action:"switchFanMode"
state "fanOn", label:'${name}', action:"switchFanMode"
state "fanCirculate", label:'${name}', action:"switchFanMode"
}
controlTile("heatSliderControl", "device.heatingSetpoint", "slider", height: 1, width: 2, inactiveLabel: false) {
state "setHeatingSetpoint", action:"quickSetHeat", backgroundColor:"#d04e00"
@@ -119,8 +117,11 @@ metadata {
standardTile("refresh", "device.thermostatMode", inactiveLabel: false, decoration: "flat") {
state "default", action:"polling.poll", icon:"st.secondary.refresh"
}
standardTile("configure", "device.configure", inactiveLabel: false, decoration: "flat") {
state "configure", label:'', action:"configuration.configure", icon:"st.secondary.configure"
}
main "temperature"
details(["temperature", "mode", "fanMode", "heatSliderControl", "heatingSetpoint", "coolSliderControl", "coolingSetpoint", "refresh"])
details(["temperature", "mode", "fanMode", "heatSliderControl", "heatingSetpoint", "coolSliderControl", "coolingSetpoint", "refresh", "configure"])
}
}
@@ -285,13 +286,13 @@ def zwaveEvent(physicalgraph.zwave.commands.thermostatfanmodev3.ThermostatFanMod
def map = [:]
switch (cmd.fanMode) {
case physicalgraph.zwave.commands.thermostatfanmodev3.ThermostatFanModeReport.FAN_MODE_AUTO_LOW:
map.value = "auto" // "fanAuto"
map.value = "fanAuto"
break
case physicalgraph.zwave.commands.thermostatfanmodev3.ThermostatFanModeReport.FAN_MODE_LOW:
map.value = "on" // "fanOn"
map.value = "fanOn"
break
case physicalgraph.zwave.commands.thermostatfanmodev3.ThermostatFanModeReport.FAN_MODE_CIRCULATION:
map.value = "circulate" // "fanCirculate"
map.value = "fanCirculate"
break
}
map.name = "thermostatFanMode"
@@ -308,19 +309,15 @@ def zwaveEvent(physicalgraph.zwave.commands.thermostatmodev2.ThermostatModeSuppo
if(cmd.auto) { supportedModes += "auto " }
state.supportedModes = supportedModes
// No events to be generated, return empty map
return [:]
}
def zwaveEvent(physicalgraph.zwave.commands.thermostatfanmodev3.ThermostatFanModeSupportedReport cmd) {
def supportedFanModes = ""
if(cmd.auto) { supportedFanModes += "auto " } // "fanAuto "
if(cmd.low) { supportedFanModes += "on " } // "fanOn"
if(cmd.circulation) { supportedFanModes += "circulate " } // "fanCirculate"
if(cmd.auto) { supportedFanModes += "fanAuto " }
if(cmd.low) { supportedFanModes += "fanOn " }
if(cmd.circulation) { supportedFanModes += "fanCirculate " }
state.supportedFanModes = supportedFanModes
// No events to be generated, return empty map
return [:]
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
@@ -415,13 +412,7 @@ def configure() {
delayBetween([
zwave.thermostatModeV2.thermostatModeSupportedGet().format(),
zwave.thermostatFanModeV3.thermostatFanModeSupportedGet().format(),
zwave.associationV1.associationSet(groupingIdentifier:1, nodeId:[zwaveHubNodeId]).format(),
zwave.sensorMultilevelV3.sensorMultilevelGet().format(), // current temperature
zwave.thermostatSetpointV1.thermostatSetpointGet(setpointType: 1).format(),
zwave.thermostatSetpointV1.thermostatSetpointGet(setpointType: 2).format(),
zwave.thermostatModeV2.thermostatModeGet().format(),
zwave.thermostatFanModeV3.thermostatFanModeGet().format(),
zwave.thermostatOperatingStateV1.thermostatOperatingStateGet().format()
zwave.associationV1.associationSet(groupingIdentifier:1, nodeId:[zwaveHubNodeId]).format()
], 2300)
}
@@ -462,11 +453,11 @@ def switchToMode(nextMode) {
def switchFanMode() {
def currentMode = device.currentState("thermostatFanMode")?.value
def lastTriedMode = state.lastTriedFanMode ?: currentMode ?: "off"
def supportedModes = getDataByName("supportedFanModes") ?: "auto on" // "fanAuto fanOn"
def modeOrder = ["auto", "circulate", "on"] // "fanAuto", "fanCirculate", "fanOn"
def supportedModes = getDataByName("supportedFanModes") ?: "fanAuto fanOn"
def modeOrder = ["fanAuto", "fanCirculate", "fanOn"]
def next = { modeOrder[modeOrder.indexOf(it) + 1] ?: modeOrder[0] }
def nextMode = next(lastTriedMode)
while (!supportedModes?.contains(nextMode) && nextMode != "auto") { // "fanAuto"
while (!supportedModes?.contains(nextMode) && nextMode != "fanAuto") {
nextMode = next(nextMode)
}
switchToFanMode(nextMode)
@@ -477,11 +468,11 @@ def switchToFanMode(nextMode) {
if(supportedFanModes && !supportedFanModes.contains(nextMode)) log.warn "thermostat mode '$nextMode' is not supported"
def returnCommand
if (nextMode == "auto") { // "fanAuto"
if (nextMode == "fanAuto") {
returnCommand = fanAuto()
} else if (nextMode == "on") { // "fanOn"
} else if (nextMode == "fanOn") {
returnCommand = fanOn()
} else if (nextMode == "circulate") { // "fanCirculate"
} else if (nextMode == "fanCirculate") {
returnCommand = fanCirculate()
} else {
log.debug("no fan mode '$nextMode'")