Compare commits

...

8 Commits

Author SHA1 Message Date
Kevin Shuk
5c70da54a4 Merge pull request #1378 from surfous/DVCSMP-2155-ZigBee-switch-power-dh-hchk
DVCSMP-2155 ZigBee switch power DH health check
2016-10-28 10:44:36 -07:00
Vinay Rao
687c64d29d Merge pull request #1305 from ShilpaMathew/DEVC-489-2
DEVC-489: Add fingerprint for Leviton 73A00-3ZB
2016-10-27 14:51:12 -07:00
Kevin Shuk
c9d1b168f7 DVCSMP-2155 ZigBee switch power DH health check
* Add capability Health Check
* specify 5 minute reporting interval to `zigbee.onOffConfig()`
* set the checkInterval attribute in `configure()` (as it sets the reporting interval)
* implements `ping()` by sending the `zigbee.onOffRefresh()` command

For the Google Home project, supports specifically
* GE/Jasco ZigBee Plug-in Smart Switch (45853)
* GE/Jasco ZigBee In-Wall Smart Switch (45856)

The DH itself supports those, plus the Smartthings Outlet V4
* `fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 000F, 0B04", outClusters: "0019"`

and two other generic fingerprints:
* `fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0B04"`
* `fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0702"`
2016-10-27 14:29:20 -07:00
Jack Chi
2f87309fdf Merge pull request #1383 from pchomal/zigbeeDimmer_power
CHF-435 Implementation of Health Check for Zigbee Dimmer (GE Plug-In/In-Wall Smart Dimmer)
2016-10-26 21:58:51 -07:00
Jack Chi
37524f17b2 Merge pull request #1395 from jackchi/health-configure-to-updated
[CHF-429] Device Health enrollment refactored into updated()
2016-10-26 14:19:22 -07:00
jackchi
47522facc7 [CHF-429] Device Health enrollment refactored into updated() from configure() 2016-10-26 10:04:51 -07:00
piyush.c
72b2016b7d CHF-435
Implementation of Health Check for Zigbee Dimmer (GE Plug-In/In-Wall Smart Dimmer)
2016-10-24 14:26:22 +05:30
ShilpaMathew
6a1a2b0ed9 Add fingerprint for Leviton 73A00-3ZB 2016-09-27 14:49:25 -07:00
15 changed files with 241 additions and 49 deletions

View File

@@ -59,6 +59,15 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "${device} updated"
configureHealthCheck()
}
// Parse incoming device messages to generate events
def parse(String description) {
log.debug "description is $description"
@@ -96,6 +105,14 @@ def refresh() {
zigbee.onOffRefresh() + zigbee.levelRefresh()
}
def configureHealthCheck() {
log.debug "configureHealthCheck"
unschedule("healthPoll")
runEvery5Minutes("healthPoll")
// Device-Watch allows 2 check-in misses from device
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def healthPoll() {
log.debug "healthPoll()"
def cmds = zigbee.onOffRefresh() + zigbee.levelRefresh()
@@ -103,9 +120,5 @@ def healthPoll() {
}
def configure() {
unschedule()
runEvery5Minutes("healthPoll")
// Device-Watch allows 2 check-in misses from device
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
zigbee.onOffRefresh() + zigbee.levelRefresh()
refresh()
}

View File

@@ -74,6 +74,15 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "${device} updated"
configureHealthCheck()
}
// Parse incoming device messages to generate events
def parse(String description) {
log.debug "description is $description"
@@ -140,10 +149,14 @@ def refresh() {
zigbee.onOffRefresh() + zigbee.electricMeasurementPowerRefresh()
}
def configure() {
def configureHealthCheck() {
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def configure() {
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
refresh() + zigbee.onOffConfig(0, 300) + powerConfig()

View File

@@ -84,6 +84,15 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "${device} updated"
configureHealthCheck()
}
def parse(String description) {
log.debug "description: $description"
@@ -303,11 +312,13 @@ def refresh() {
return refreshCmds + enrollResponse()
}
def configure() {
def configureHealthCheck() {
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def configure() {
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
// battery minReport 30 seconds, maxReportTime 6 hrs by default
return refresh() + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) // send refresh cmds as part of config

View File

@@ -88,6 +88,15 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "${device} updated"
configureHealthCheck()
}
def parse(String description) {
log.debug "description: $description"
@@ -318,11 +327,13 @@ def refresh() {
return refreshCmds + enrollResponse()
}
def configure() {
def configureHealthCheck() {
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def configure() {
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
// battery minReport 30 seconds, maxReportTime 6 hrs by default
return refresh() + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) // send refresh cmds as part of config

View File

@@ -115,6 +115,34 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "updated called"
log.info "garage value : $garageSensor"
if (garageSensor == "Yes") {
def descriptionText = "Updating device to garage sensor"
if (device.latestValue("status") == "open") {
sendEvent(name: 'status', value: 'garage-open', descriptionText: descriptionText, translatable: true)
}
else if (device.latestValue("status") == "closed") {
sendEvent(name: 'status', value: 'garage-closed', descriptionText: descriptionText, translatable: true)
}
}
else {
def descriptionText = "Updating device to open/close sensor"
if (device.latestValue("status") == "garage-open") {
sendEvent(name: 'status', value: 'open', descriptionText: descriptionText, translatable: true)
}
else if (device.latestValue("status") == "garage-closed") {
sendEvent(name: 'status', value: 'closed', descriptionText: descriptionText, translatable: true)
}
}
configureHealthCheck()
}
def parse(String description) {
Map map = [:]
if (description?.startsWith('catchall:')) {
@@ -246,29 +274,6 @@ private Map parseIasMessage(String description) {
return resultMap
}
def updated() {
log.debug "updated called"
log.info "garage value : $garageSensor"
if (garageSensor == "Yes") {
def descriptionText = "Updating device to garage sensor"
if (device.latestValue("status") == "open") {
sendEvent(name: 'status', value: 'garage-open', descriptionText: descriptionText, translatable: true)
}
else if (device.latestValue("status") == "closed") {
sendEvent(name: 'status', value: 'garage-closed', descriptionText: descriptionText, translatable: true)
}
}
else {
def descriptionText = "Updating device to open/close sensor"
if (device.latestValue("status") == "garage-open") {
sendEvent(name: 'status', value: 'open', descriptionText: descriptionText, translatable: true)
}
else if (device.latestValue("status") == "garage-closed") {
sendEvent(name: 'status', value: 'closed', descriptionText: descriptionText, translatable: true)
}
}
}
def getTemperature(value) {
def celsius = Integer.parseInt(value, 16).shortValue() / 100
if(getTemperatureScale() == "C"){
@@ -411,11 +416,13 @@ def refresh() {
return refreshCmds + enrollResponse()
}
def configure() {
def configureHealthCheck(){
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def configure() {
log.debug "Configuring Reporting"
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity

View File

@@ -75,6 +75,15 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "${device} updated"
configureHealthCheck()
}
def parse(String description) {
log.debug "description: $description"
@@ -265,11 +274,12 @@ def refresh() {
return refreshCmds + enrollResponse()
}
def configure() {
def configureHealthCheck() {
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def configure() {
log.debug "Configuring Reporting, IAS CIE, and Bindings."
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity

View File

@@ -69,6 +69,15 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "${device} updated"
configureHealthCheck()
}
def parse(String description) {
log.debug "description: $description"
@@ -268,11 +277,13 @@ def refresh()
zigbee.readAttribute(0x0001, 0x0020)
}
def configure() {
def configureHealthCheck() {
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def configure() {
log.debug "Configuring Reporting and Bindings."
def humidityConfigCmds = [
"zdo bind 0x${device.deviceNetworkId} 1 1 0xFC45 {${device.zigbeeId}} {}", "delay 500",

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,41 @@
# GE Plug-In/In-Wall Smart Dimmer (ZigBee)
Works with:
* [GE In-Wall Smart Dimmer (ZigBee)](https://shop.smartthings.com/#!/products/ge-in-wall-smart-dimmer-switch)
* [GE Plug-In Smart Dimmer (ZigBee)](https://www.smartthings.com/works-with-smartthings/ge/ge-plug-in-smart-dimmer-zigbee)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Troubleshooting](#Troubleshooting)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
* **Refresh** - _refresh()_ command for status updates
* **Power Meter** - ability to check the power meter(energy consumption) of device
* **Sensor** - represents the device sensor capability
* **Switch** - can detect state (possible values: on/off)
* **Switch Level** - represents current light level, usually 0-100 in percent
* **Health Check** - indicates ability to get device health notifications
## Device Health
A Zigbee dimmer with maxReportTime of 5 mins.
Check-in interval is double the value of maxReportTime.
This gives the device twice the amount of time to respond before it is marked as offline.
Enrolls with default periodic reporting until newer 5 min interval is confirmed
It then enrolls the device with updated checkInterval i.e. 12 mins
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [GE Z-Wave In-Wall Smart Dimmer (GE 45857) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/204988564-GE-In-Wall-Smart-Dimmer-45857GE-ZigBee-)
* [GE Zigbee Plug-in Smart Dimmer (GE 45852) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205239280-GE-Plug-In-Smart-Dimmer-45852GE-ZigBee-)

View File

@@ -21,6 +21,7 @@ metadata {
capability "Sensor"
capability "Switch"
capability "Switch Level"
capability "Health Check"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B04"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702"
@@ -70,8 +71,20 @@ def parse(String description) {
}
}
else {
log.warn "DID NOT PARSE MESSAGE for description : $description"
log.debug zigbee.parseDescriptionAsMap(description)
def cluster = zigbee.parse(description)
if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07) {
if (cluster.data[0] == 0x00){
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
else {
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
}
}
else {
log.warn "DID NOT PARSE MESSAGE for description : $description"
log.debug zigbee.parseDescriptionAsMap(description)
}
}
}
@@ -87,11 +100,22 @@ def setLevel(value) {
zigbee.setLevel(value)
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
return zigbee.onOffRefresh()
}
def refresh() {
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.simpleMeteringPowerRefresh() + zigbee.electricMeasurementPowerRefresh() + zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.simpleMeteringPowerConfig() + zigbee.electricMeasurementPowerConfig()
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.simpleMeteringPowerRefresh() + zigbee.electricMeasurementPowerRefresh() + zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.simpleMeteringPowerConfig() + zigbee.electricMeasurementPowerConfig()
}
def configure() {
log.debug "Configuring Reporting and Bindings."
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
refresh()
}

View File

@@ -48,6 +48,15 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "${device} updated"
configureHealthCheck()
}
// Parse incoming device messages to generate events
def parse(String description) {
log.debug "description is $description"
@@ -100,12 +109,13 @@ def refresh() {
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.onOffConfig(0, 300) + zigbee.levelConfig()
}
def configure() {
log.debug "Configuring Reporting and Bindings."
def configureHealthCheck() {
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def configure() {
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.onOffConfig(0, 300) + zigbee.levelConfig()
}

View File

@@ -70,6 +70,16 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "${device} updated"
configureHealthCheck()
}
//Globals
private getATTRIBUTE_HUE() { 0x0000 }
private getATTRIBUTE_SATURATION() { 0x0001 }
@@ -138,16 +148,17 @@ def ping() {
}
def refresh() {
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_COLOR_TEMPERATURE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION) + zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.colorTemperatureConfig() + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE, 0x20, 1, 3600, 0x01) + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION, 0x20, 1, 3600, 0x01)
}
def configure() {
log.debug "Configuring Reporting and Bindings."
def configureHealthCheck() {
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
def configure() {
refresh()
}

View File

@@ -20,6 +20,7 @@ metadata {
capability "Power Meter"
capability "Sensor"
capability "Switch"
capability "Health Check"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0B04"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0702"
@@ -77,10 +78,26 @@ def on() {
}
def refresh() {
zigbee.onOffRefresh() + zigbee.simpleMeteringPowerRefresh() + zigbee.electricMeasurementPowerRefresh() + zigbee.onOffConfig() + zigbee.simpleMeteringPowerConfig() + zigbee.electricMeasurementPowerConfig()
Integer reportIntervalMinutes = 5
zigbee.onOffRefresh() + zigbee.simpleMeteringPowerRefresh() + zigbee.electricMeasurementPowerRefresh() + zigbee.onOffConfig(0,reportIntervalMinutes * 60) + zigbee.simpleMeteringPowerConfig() + zigbee.electricMeasurementPowerConfig()
}
def configure() {
log.debug "Configuring Reporting and Bindings."
refresh()
log.debug "in configure()"
configureHealthCheck()
}
def configureHealthCheck() {
Integer hcIntervalMinutes = 12
refresh()
sendEvent(name: "checkInterval", value: hcIntervalMinutes * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
def updated() {
log.debug "in updated()"
configureHealthCheck()
}
def ping() {
return zigbee.onOffRefresh()
}

View File

@@ -21,6 +21,7 @@ metadata {
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0006", outClusters: "0003, 0006, 0019, 0406", manufacturer: "Leviton", model: "ZSS-10", deviceJoinName: "Leviton Switch"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0006", outClusters: "000A", manufacturer: "HAI", model: "65A21-1", deviceJoinName: "Leviton Wireless Load Control Module-30amp"
}
// simulator metadata

View File

@@ -69,6 +69,15 @@ metadata {
}
}
def installed() {
log.debug "${device} installed"
}
def updated() {
log.debug "${device} updated"
configureHealthCheck()
}
// Parse incoming device messages to generate events
def parse(String description) {
log.debug "description is $description"
@@ -121,16 +130,17 @@ def ping() {
}
def refresh() {
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh() + zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.colorTemperatureConfig()
}
def configure() {
log.debug "Configuring Reporting and Bindings."
def configureHealthCheck() {
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
def configure() {
refresh()
}