@@ -0,0 +1,254 @@
|
||||
/**
|
||||
* Fibaro Wall Plug ZW5
|
||||
*
|
||||
* Copyright 2016 Fibar Group S.A.
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
|
||||
* in compliance with the License. You may obtain a copy of the License at:
|
||||
*
|
||||
* http://www.apache.org/licenses/LICENSE-2.0
|
||||
*
|
||||
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
|
||||
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
*/
|
||||
metadata {
|
||||
definition (name: "Fibaro Wall Plug ZW5", namespace: "fibargroup", author: "Fibar Group S.A.") {
|
||||
capability "Actuator"
|
||||
capability "Configuration"
|
||||
capability "Energy Meter"
|
||||
capability "Power Meter"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Switch"
|
||||
|
||||
command "reset"
|
||||
|
||||
fingerprint deviceId: "0x1001", inClusters: "0x5E, 0x22, 0x85, 0x59, 0x70, 0x56, 0x5A, 0x7A, 0x72, 0x32, 0x8E, 0x71, 0x73, 0x98, 0x31, 0x25, 0x86", outClusters: ""
|
||||
}
|
||||
|
||||
simulator {
|
||||
|
||||
}
|
||||
|
||||
tiles(scale: 2) {
|
||||
multiAttributeTile(name:"FGWP", type:"lighting", width:6, height:4) {//with generic type secondary control text is not displayed in Android app
|
||||
tileAttribute("device.switch", key:"PRIMARY_CONTROL") {
|
||||
attributeState("on", label: '${name}', action: "switch.off", icon:"st.switches.switch.on", backgroundColor:"#79b821")
|
||||
attributeState("off", label: '${name}', action: "switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff")
|
||||
}
|
||||
|
||||
tileAttribute("device.power", key:"SECONDARY_CONTROL") {
|
||||
attributeState("default", label:'${currentValue} W', backgroundColor:"#ffffff")
|
||||
}
|
||||
}
|
||||
|
||||
valueTile("energy", "device.energy", width: 2, height: 2) {
|
||||
state "default", label:'${currentValue} kWh'
|
||||
}
|
||||
standardTile("reset", "device.energy", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
|
||||
state "default", label:'reset kWh', action:"reset"
|
||||
}
|
||||
standardTile("refresh", "device.power", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
|
||||
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
|
||||
}
|
||||
|
||||
main "FGWP"
|
||||
details(["FGWP", "energy", "reset", "refresh"])
|
||||
}
|
||||
}
|
||||
|
||||
// parse events into attributes
|
||||
def parse(String description) {
|
||||
log.debug "Parsing '${description}'"
|
||||
|
||||
if (description.startsWith("Err 106")) {
|
||||
if (state.sec) {
|
||||
result = createEvent(descriptionText:description, displayed:false)
|
||||
} else {
|
||||
result = createEvent(
|
||||
descriptionText: "FGK failed to complete the network security key exchange. If you are unable to receive data from it, you must remove it from your network and add it again.",
|
||||
eventType: "ALERT",
|
||||
name: "secureInclusion",
|
||||
value: "failed",
|
||||
displayed: true,
|
||||
)
|
||||
}
|
||||
} else if (description == "updated") {
|
||||
return null
|
||||
} else {
|
||||
def cmd = zwave.parse(description, [0x25: 1, 0x31: 5, 0x32: 1, 0x5A: 1, 0x71: 3, 0x72: 2, 0x86: 1])
|
||||
|
||||
if (cmd) {
|
||||
log.debug "Parsed '${cmd}'"
|
||||
zwaveEvent(cmd)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
//security
|
||||
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
|
||||
def encapsulatedCommand = cmd.encapsulatedCommand([0x25: 1, 0x5A: 1])
|
||||
if (encapsulatedCommand) {
|
||||
return zwaveEvent(encapsulatedCommand)
|
||||
} else {
|
||||
log.warn "Unable to extract encapsulated cmd from $cmd"
|
||||
createEvent(descriptionText: cmd.toString())
|
||||
}
|
||||
}
|
||||
|
||||
//crc16
|
||||
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd)
|
||||
{
|
||||
def versions = [0x31: 5, 0x32: 1, 0x71: 3, 0x72: 2, 0x86: 1]
|
||||
def version = versions[cmd.commandClass as Integer]
|
||||
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
|
||||
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
|
||||
if (!encapsulatedCommand) {
|
||||
log.debug "Could not extract command from $cmd"
|
||||
} else {
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.meterv1.MeterReport cmd) {
|
||||
if (cmd.scale == 0) {
|
||||
createEvent(name: "energy", value: cmd.scaledMeterValue, unit: "kWh")
|
||||
} else if (cmd.scale == 2) {
|
||||
createEvent(name: "power", value: Math.round(cmd.scaledMeterValue), unit: "W")
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerSpecificReport cmd) {
|
||||
log.debug "manufacturerId: ${cmd.manufacturerId}"
|
||||
log.debug "manufacturerName: ${cmd.manufacturerName}"
|
||||
log.debug "productId: ${cmd.productId}"
|
||||
log.debug "productTypeId: ${cmd.productTypeId}"
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.DeviceSpecificReport cmd) {
|
||||
log.debug "deviceIdData: ${cmd.deviceIdData}"
|
||||
log.debug "deviceIdDataFormat: ${cmd.deviceIdDataFormat}"
|
||||
log.debug "deviceIdDataLengthIndicator: ${cmd.deviceIdDataLengthIndicator}"
|
||||
log.debug "deviceIdType: ${cmd.deviceIdType}"
|
||||
|
||||
if (cmd.deviceIdType == 1 && cmd.deviceIdDataFormat == 1) {//serial number in binary format
|
||||
String serialNumber = "h'"
|
||||
|
||||
cmd.deviceIdData.each{ data ->
|
||||
serialNumber += "${String.format("%02X", data)}"
|
||||
}
|
||||
|
||||
updateDataValue("serialNumber", serialNumber)
|
||||
log.debug "${device.displayName} - serial number: ${serialNumber}"
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.versionv1.VersionReport cmd) {
|
||||
updateDataValue("version", "${cmd.applicationVersion}.${cmd.applicationSubVersion}")
|
||||
log.debug "applicationVersion: ${cmd.applicationVersion}"
|
||||
log.debug "applicationSubVersion: ${cmd.applicationSubVersion}"
|
||||
log.debug "zWaveLibraryType: ${cmd.zWaveLibraryType}"
|
||||
log.debug "zWaveProtocolVersion: ${cmd.zWaveProtocolVersion}"
|
||||
log.debug "zWaveProtocolSubVersion: ${cmd.zWaveProtocolSubVersion}"
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd) {
|
||||
def map = [ displayed: true ]
|
||||
if (cmd.sensorType == 4) {
|
||||
createEvent(name: "power", value: Math.round(cmd.scaledSensorValue), unit: "W")
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd) {
|
||||
createEvent(name: "switch", value: cmd.value ? "on" : "off", type: "digital")
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.deviceresetlocallyv1.DeviceResetLocallyNotification cmd) {
|
||||
log.info "${device.displayName}: received command: $cmd - device has reset itself"
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.notificationv3.NotificationReport cmd)
|
||||
{
|
||||
if (cmd.notificationType == 0x08) {
|
||||
if (cmd.event == 0x06) {
|
||||
createEvent(descriptionText: "Warning: $device.displayName detected over-current", isStateChange: true)
|
||||
} else if (cmd.event == 0x08) {
|
||||
createEvent(descriptionText: "Warning: $device.displayName detected over-load", isStateChange: true)
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
log.debug "$device.displayName: Unhandled: $cmd"
|
||||
[:]
|
||||
}
|
||||
|
||||
// handle commands
|
||||
def configure() {
|
||||
log.debug "Executing 'configure'"
|
||||
|
||||
def cmds = []
|
||||
|
||||
cmds += zwave.manufacturerSpecificV1.manufacturerSpecificGet()
|
||||
cmds += zwave.manufacturerSpecificV2.deviceSpecificGet()
|
||||
cmds += zwave.versionV1.versionGet()
|
||||
cmds += zwave.associationV2.associationSet(groupingIdentifier:1, nodeId:[zwaveHubNodeId])
|
||||
cmds += zwave.meterV2.meterGet(scale:0)
|
||||
cmds += zwave.meterV2.meterGet(scale:2)
|
||||
cmds += zwave.switchBinaryV1.switchBinaryGet()
|
||||
|
||||
encapSequence(cmds, 500)
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
log.debug "Executing 'refresh'"
|
||||
|
||||
def cmds = []
|
||||
cmds += zwave.meterV2.meterGet(scale:0)
|
||||
cmds += zwave.meterV2.meterGet(scale:2)
|
||||
cmds += zwave.switchBinaryV1.switchBinaryGet()
|
||||
|
||||
encapSequence(cmds, 500)
|
||||
}
|
||||
|
||||
def on() {
|
||||
log.debug "Executing 'on'"
|
||||
encap(zwave.switchBinaryV1.switchBinarySet(switchValue: 0xFF))
|
||||
}
|
||||
|
||||
def off() {
|
||||
log.debug "Executing 'off'"
|
||||
encap(zwave.switchBinaryV1.switchBinarySet(switchValue: 0x00))
|
||||
}
|
||||
|
||||
def reset() {
|
||||
log.debug "Executing 'reset'"
|
||||
encap(zwave.meterV2.meterReset())
|
||||
}
|
||||
|
||||
private secure(physicalgraph.zwave.Command cmd) {
|
||||
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
|
||||
}
|
||||
|
||||
private crc16(physicalgraph.zwave.Command cmd) {
|
||||
//zwave.crc16encapV1.crc16Encap().encapsulate(cmd).format()
|
||||
"5601${cmd.format()}0000"
|
||||
}
|
||||
|
||||
private encapSequence(commands, delay=200) {
|
||||
delayBetween(commands.collect{ encap(it) }, delay)
|
||||
}
|
||||
|
||||
private encap(physicalgraph.zwave.Command cmd) {
|
||||
def secureClasses = [0x25, 0x5A, 0x70, 0x85, 0x8E]
|
||||
|
||||
//todo: check if secure inclusion was successful
|
||||
//if not do not send security-encapsulated command
|
||||
if (secureClasses.find{ it == cmd.commandClassId }) {
|
||||
secure(cmd)
|
||||
} else {
|
||||
crc16(cmd)
|
||||
}
|
||||
}
|
||||
Reference in New Issue