Compare commits

..

5 Commits

Author SHA1 Message Date
Mattias Svännel
6880817cc6 MSA-2000: ClassicGOD:Fibaro Wall Plug ZW5 2017-05-23 10:34:23 -07:00
Duncan McKee
10964873cd Merge pull request #2001 from mckeed/DVCSMP-2493
DVCSMP-2493 Notify Multi-Channel Control app when root device is deleted
2017-05-23 13:33:55 -04:00
Zach Varberg
20f086fe69 Merge pull request #2023 from varzac/fix-multisensor-npe
[DVCSMP-2668] Fix NPE for smartsense multi
2017-05-23 09:08:47 -05:00
Zach Varberg
97c9ec7a95 Fix NPE for smartsense multi
There was a common NPE caused by assuming there would be additional
attributes reported with one acceleration value.  This corrects it to
instead properly handle the case where there weren't additional
attributes.

This resolves: https://smartthings.atlassian.net/browse/DVCSMP-2668
2017-05-22 11:52:13 -05:00
Duncan McKee
52c57f66fb DVCSMP-2493 Notify Multi-Channel Control app when root device is deleted 2017-03-06 13:31:32 -05:00
4 changed files with 375 additions and 4 deletions

View File

@@ -0,0 +1,368 @@
/**
* Fibaro Wall Plug ZW5
* Requires: Fibaro Double Switch 2 Child Device
*
* Copyright 2017 Artur Draga
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
*/
metadata {
definition (name: "Fibaro Wall Plug ZW5", namespace: "ClassicGOD", author: "Artur Draga") {
capability "Switch"
capability "Energy Meter"
capability "Power Meter"
capability "Configuration"
capability "Health Check"
command "reset"
command "refresh"
fingerprint deviceId: "0x1001", inClusters:"0x5E,0x22,0x59,0x56,0x7A,0x32,0x71,0x73,0x98,0x31,0x85,0x70,0x72,0x5A,0x8E,0x25,0x86"
fingerprint deviceId: "0x1001", inClusters:"0x5E,0x22,0x59,0x56,0x7A,0x32,0x71,0x73,0x31,0x85,0x70,0x72,0x5A,0x8E,0x25,0x86"
}
tiles (scale: 2) {
multiAttributeTile(name:"switch", type: "lighting", width: 3, height: 4, canChangeIcon: true){
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
attributeState "off", label: 'Off', action: "switch.on", icon: "st.switches.switch.off", backgroundColor: "#ffffff", nextState:"turningOn"
attributeState "on", label: 'On', action: "switch.off", icon: "st.switches.switch.on", backgroundColor: "#00a0dc", nextState:"turningOff"
attributeState "turningOn", label:'Turning On', action:"switch.off", icon:"st.switches.switch.on", backgroundColor:"#00a0dc", nextState:"turningOff"
attributeState "turningOff", label:'Turning Off', action:"switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff", nextState:"turningOn"
}
tileAttribute("device.combinedMeter", key:"SECONDARY_CONTROL") {
attributeState("combinedMeter", label:'${currentValue}')
}
}
valueTile("power", "device.power", decoration: "flat", width: 2, height: 2) {
state "power", label:'${currentValue}\nW', action:"refresh"
}
valueTile("energy", "device.energy", decoration: "flat", width: 2, height: 2) {
state "energy", label:'${currentValue}\nkWh', action:"refresh"
}
valueTile("reset", "device.energy", decoration: "flat", width: 2, height: 2) {
state "reset", label:'reset\nkWh', action:"reset"
}
}
preferences {
input ( name: "logging", title: "Logging", type: "boolean", required: false )
parameterMap().each {
input (
name: it.key,
title: "${it.num}. ${it.title}",
description: it.descr,
type: it.type,
options: it.options,
range: (it.min != null && it.max != null) ? "${it.min}..${it.max}" : null,
defaultValue: it.def,
required: false
)
}
}
}
//UI and tile functions
def on() {
encap(zwave.basicV1.basicSet(value: 255))
}
def off() {
encap(zwave.basicV1.basicSet(value: 0))
}
def reset() {
def cmds = []
cmds << zwave.meterV3.meterReset()
cmds << zwave.meterV3.meterGet(scale: 0)
cmds << zwave.meterV3.meterGet(scale: 2)
encapSequence(cmds,1000)
}
def refresh() {
def cmds = []
cmds << zwave.meterV3.meterGet(scale: 0)
cmds << zwave.meterV3.meterGet(scale: 2)
cmds << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 4)
encapSequence(cmds,1000)
}
//Configuration and synchronization
def updated() {
if ( state.lastUpdated && (now() - state.lastUpdated) < 500 ) return
def cmds = []
logging("${device.displayName} - Executing updated()","info")
def Integer cmdCount = 0
parameterMap().each {
if(settings."$it.key" != null) {
if (state."$it.key" == null) { state."$it.key" = [value: null, state: "synced"] }
if (state."$it.key".value != settings."$it.key" as Integer || state."$it.key".state == "notSynced") {
state."$it.key".value = settings."$it.key" as Integer
state."$it.key".state = "notSynced"
cmds << zwave.configurationV2.configurationSet(configurationValue: intToParam(state."$it.key".value, it.size), parameterNumber: it.num, size: it.size)
cmds << zwave.configurationV2.configurationGet(parameterNumber: it.num)
cmdCount = cmdCount + 1
}
}
}
if ( cmdCount > 0 ) {
logging("${device.displayName} - sending config.", "info")
sendEvent(name: "combinedMeter", value: "SYNC IN PROGRESS.", displayed: false)
runIn((5+cmdCount*2), syncCheck)
}
state.lastUpdated = now()
if (cmds) { response(encapSequence(cmds,1000)) }
}
def syncCheck() {
logging("${device.displayName} - Executing syncCheck()","info")
def Integer count = 0
if (device.currentValue("combinedMeter")?.contains("SYNC") && device.currentValue("combinedMeter") != "SYNC OK.") {
parameterMap().each {
if (state."$it.key".state == "notSynced" ) {
count = count + 1
}
}
}
if (count == 0) {
logging("${device.displayName} - Sync Complete","info")
sendEvent(name: "combinedMeter", value: "SYNC OK.", displayed: false)
} else {
logging("${device.displayName} Sync Incomplete","info")
if (device.currentValue("combinedMeter") != "SYNC FAILED!") {
sendEvent(name: "combinedMeter", value: "SYNC INCOMPLETE.", displayed: false)
}
}
}
//event handlers related to configuration and sync
def zwaveEvent(physicalgraph.zwave.commands.configurationv2.ConfigurationReport cmd) {
def paramKey = parameterMap().find( {it.num == cmd.parameterNumber } ).key
logging("${device.displayName} - Parameter ${paramKey} value is ${cmd.scaledConfigurationValue} expected " + state."$paramKey".value, "info")
if (state."$paramKey".value == cmd.scaledConfigurationValue) {
state."$paramKey".state = "synced"
}
}
def zwaveEvent(physicalgraph.zwave.commands.applicationstatusv1.ApplicationRejectedRequest cmd) {
logging("${device.displayName} - rejected request!","warn")
if (device.currentValue("combinedMeter") == "SYNC IN PROGRESS.") {
sendEvent(name: "combinedMeter", value: "SYNC FAILED!", displayed: false)
}
}
//event handlers
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
//ignore
}
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd) {
logging("${device.displayName} - SwitchBinaryReport received, value: ${cmd.value}","info")
sendEvent([name: "switch", value: (cmd.value == 0 ) ? "off": "on"])
}
def zwaveEvent(physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd) {
logging("${device.displayName} - SensorMultilevelReport received, value: ${cmd.scaledSensorValue} scale: ${cmd.scale}","info")
if (cmd.sensorType == 4) {
sendEvent([name: "power", value: cmd.scaledSensorValue, unit: "W"])
updateCombinedMeter()
}
}
def zwaveEvent(physicalgraph.zwave.commands.meterv3.MeterReport cmd) {
logging("${device.displayName} - MeterReport received, value: ${cmd.scaledMeterValue} scale: ${cmd.scale}","info")
switch (cmd.scale) {
case 0:
sendEvent([name: "energy", value: cmd.scaledMeterValue, unit: "kWh"])
break
case 2:
sendEvent([name: "power", value: cmd.scaledMeterValue, unit: "W"])
break
}
updateCombinedMeter()
}
//other
private updateCombinedMeter() {
if (!device.currentValue("combinedMeter")?.contains("SYNC") || device.currentValue("combinedMeter") == "SYNC OK." || device.currentValue("combinedMeter") == null ) {
sendEvent([name: "combinedMeter", value: "${device.currentValue("power")} W / ${device.currentValue("energy")} kWh", displayed: false])
}
}
/*
####################
## Z-Wave Toolkit ##
####################
*/
def parse(String description) {
def result = []
logging("${device.displayName} - Parsing: ${description}")
if (description.startsWith("Err 106")) {
result = createEvent(
descriptionText: "Failed to complete the network security key exchange. If you are unable to receive data from it, you must remove it from your network and add it again.",
eventType: "ALERT",
name: "secureInclusion",
value: "failed",
displayed: true,
)
} else if (description == "updated") {
return null
} else {
def cmd = zwave.parse(description, cmdVersions())
if (cmd) {
logging("${device.displayName} - Parsed: ${cmd}")
zwaveEvent(cmd)
}
}
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand(cmdVersions())
if (encapsulatedCommand) {
logging("${device.displayName} - Parsed SecurityMessageEncapsulation into: ${encapsulatedCommand}")
zwaveEvent(encapsulatedCommand)
} else {
log.warn "Unable to extract secure cmd from $cmd"
createEvent(descriptionText: cmd.toString())
}
}
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
def version = cmdVersions()[cmd.commandClass as Integer]
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
if (!encapsulatedCommand) {
log.warn "Could not extract crc16 command from $cmd"
} else {
logging("${device.displayName} - Parsed Crc16Encap into: ${encapsulatedCommand}")
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.commands.multichannelv3.MultiChannelCmdEncap cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand(cmdVersions())
if (encapsulatedCommand) {
logging("${device.displayName} - Parsed MultiChannelCmdEncap ${encapsulatedCommand}")
zwaveEvent(encapsulatedCommand, cmd.sourceEndPoint as Integer)
}
}
private logging(text, type = "debug") {
if (settings.logging == "true") {
log."$type" text
}
}
private secEncap(physicalgraph.zwave.Command cmd) {
logging("${device.displayName} - encapsulating command using Secure Encapsulation, command: $cmd","info")
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
}
private crcEncap(physicalgraph.zwave.Command cmd) {
logging("${device.displayName} - encapsulating command using CRC16 Encapsulation, command: $cmd","info")
zwave.crc16EncapV1.crc16Encap().encapsulate(cmd).format() // doesn't work righ now because SmartThings...
//"5601${cmd.format()}0000"
}
private multiEncap(physicalgraph.zwave.Command cmd, Integer ep) {
logging("${device.displayName} - encapsulating command using Multi Channel Encapsulation, ep: $ep command: $cmd","info")
zwave.multiChannelV3.multiChannelCmdEncap(destinationEndPoint:ep).encapsulate(cmd)
}
private encap(physicalgraph.zwave.Command cmd) {
if (zwaveInfo.zw.contains("s")) {
secEncap(cmd)
} else if (zwaveInfo.cc.contains("56")){
crcEncap(cmd)
} else {
logging("${device.displayName} - no encapsulation supported for command: $cmd","info")
cmd.format()
}
}
private encap(physicalgraph.zwave.Command cmd, Integer ep) {
encap(multiEncap(cmd, ep))
}
private encap(List encapList) {
encap(encapList[0], encapList[1])
}
private encap(Map encapMap) {
encap(encapMap.cmd, encapMap.ep)
}
private encapSequence(cmds, Integer delay=250) {
delayBetween(cmds.collect{ encap(it) }, delay)
}
private encapSequence(cmds, Integer delay, Integer ep) {
delayBetween(cmds.collect{ encap(it, ep) }, delay)
}
private List intToParam(Long value, Integer size = 1) {
def result = []
size.times {
result = result.plus(0, (value & 0xFF) as Short)
value = (value >> 8)
}
return result
}
/*
##########################
## Device Configuration ##
##########################
*/
private Map cmdVersions() {
//[0x5E: 2, 0x59: 1, 0x80: 1, 0x56: 1, 0x7A: 3, 0x73: 1, 0x98: 1, 0x22: 1, 0x85: 2, 0x5B: 1, 0x70: 2, 0x8E: 2, 0x86: 2, 0x84: 2, 0x75: 2, 0x72: 2] //Fibaro KeyFob
//[0x5E: 2, 0x86: 1, 0x72: 2, 0x59: 1, 0x80: 1, 0x73: 1, 0x56: 1, 0x22: 1, 0x31: 5, 0x98: 1, 0x7A: 3, 0x20: 1, 0x5A: 1, 0x85: 2, 0x84: 2, 0x71: 3, 0x8E: 2, 0x70: 2, 0x30: 1, 0x9C: 1] //Fibaro Motion Sensor ZW5
//[0x5E: 2, 0x86: 1, 0x72: 1, 0x59: 1, 0x73: 1, 0x22: 1, 0x56: 1, 0x32: 3, 0x71: 1, 0x98: 1, 0x7A: 1, 0x25: 1, 0x5A: 1, 0x85: 2, 0x70: 2, 0x8E: 2, 0x60: 3, 0x75: 1, 0x5B: 1] //Fibaro Double Switch 2
[0x5E: 2, 0x22: 1, 0x59: 1, 0x56: 1, 0x7A: 1, 0x32: 3, 0x71: 1, 0x73: 1, 0x98: 1, 0x31: 5, 0x85: 2, 0x70: 2, 0x72: 2, 0x5A: 1, 0x8E: 2, 0x25: 1, 0x86: 2] //Fibaro Wall Plug ZW5
}
private parameterMap() {[
[key: "alwaysActive", num: 1, size: 1, type: "enum", options: [0: "0 - inactive", 1: "1 - activated"], def: "0", title: "Always on function", descr: null],
[key: "restoreState", num: 2, size: 1, type: "enum", options: [0: "0 - power off after power failure", 1: "1 - restore state"], def: "1", title: "Restore state after power failure", descr: null],
[key: "overloadSafety", num: 3, size: 2, type: "number", def: 0, min: 0, max: 30000 , title: "Overload safety switch", descr: null],
[key: "immediatePowerReports", num: 10, size: 1, type: "number", def: 80, min: 1, max: 100, title: "Immediate power reports", descr: null],
[key: "standardPowerReports", num: 11, size: 1, type: "number", def: 15, min: 1, max: 100, title: "Standard power reports", descr: null],
[key: "powerReportFrequency", num: 12, size: 2, type: "number", def: 30, min: 5, max: 600, title: "Power reporting interval", descr: null],
[key: "energyReport", num: 13, size: 2, type: "number", def: 10, min: 0, max: 500, title: "Energy reports", descr: null],
[key: "periodicReports", num: 14, size: 2, type: "number", def: 3600, min: 0, max: 32400, title: "Periodic power and energy reports", descr: null],
[key: "deviceEnergyConsumed", num: 15, size: 1, type: "enum", options: [0: "0 - don't measure", 1: "1 - measure"], def: "0", title: "Energy consumed by the device itself", descr: null],
[key: "powerLoad", num: 40, size: 2, type: "number", def: 25000, min: 1000, max: 30000, title: "Power load which makes the LED ring flash violet", descr: null],
[key: "ringColorOn", num: 41, size: 1, type: "enum", options: [
0: "0 - Off",
1: "1 - Load based - continuous",
2: "2 - Load based - steps",
3: "3 - White",
4: "4 - Red",
5: "5 - Green",
6: "6 - Blue",
7: "7 - Yellow",
8: "8 - Cyan",
9: "9 - Magenta"
], def: "1", title: "Ring LED color when on", descr: null],
[key: "ringColorOff", num: 42, size: 1, type: "enum", options: [
0: "0 - Off",
1: "1 - Last measured power",
3: "3 - White",
4: "4 - Red",
5: "5 - Green",
6: "6 - Blue",
7: "7 - Yellow",
8: "8 - Cyan",
9: "9 - Magenta"
], def: "0", title: "Ring LED color when off", descr: null]
]}

View File

@@ -178,7 +178,7 @@ private List<Map> handleAcceleration(descMap) {
result += parseAxis(descMap.additionalAttrs)
}
} else if (descMap.clusterInt == 0xFC02 && descMap.attrInt == 0x0012) {
def addAttrs = descMap.additionalAttrs
def addAttrs = descMap.additionalAttrs ?: []
addAttrs << ["attrInt": descMap.attrInt, "value": descMap.value]
result += parseAxis(addAttrs)
}

View File

@@ -34,8 +34,7 @@ import physicalgraph.zigbee.zcl.DataType
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0009,000A,0101,0020", outClusters: "000A,0019", manufacturer: "Yale", model: "YRD210 PB DB", deviceJoinName: "Yale Push Button Deadbolt Lock"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0009,000A,0101,0020", outClusters: "000A,0019", manufacturer: "Yale", model: "YRD220/240 TSDB", deviceJoinName: "Yale Touch Screen Deadbolt Lock"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0009,000A,0101,0020", outClusters: "000A,0019", manufacturer: "Yale", model: "YRL210 PB LL", deviceJoinName: "Yale Push Button Lever Lock"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0009,000A,0101,0020", outClusters: "000A,0019", manufacturer: "Yale", model: "YRD226/246 TSDB", deviceJoinName: "Yale Touch Screen Deadbolt Lock"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0009,0020,0101,0B05", outClusters: "000A, 0019, 0B05", manufacturer: "Danalock", model: "V3-BTZB",deviceJoinName: "Danalock V3-BTZB"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0009,000A,0101,0020", outClusters: "000A,0019", manufacturer: "Yale", model: "YRD226/246 TSDB", deviceJoinName: "Yale Touch Screen Deadbolt Lock"
}
tiles(scale: 2) {
@@ -171,4 +170,4 @@ private Map parseReportAttributeMessage(String description) {
log.debug "parseReportAttributeMessage() --- ignoring attribute"
}
return resultMap
}
}

View File

@@ -75,6 +75,10 @@ def parse(String description) {
return result
}
def uninstalled() {
sendEvent(name: "epEvent", value: "delete all", isStateChange: true, displayed: false, descriptionText: "Delete endpoint devices")
}
def zwaveEvent(physicalgraph.zwave.commands.wakeupv1.WakeUpNotification cmd) {
[ createEvent(descriptionText: "${device.displayName} woke up", isStateChange:true),