Compare commits

..

2 Commits

Author SHA1 Message Date
Duncan McKee
43912b75bd DHF-7 Z-Wave Lock: Add scheduled checks in case ping() is missed 2017-05-23 16:24:27 -04:00
Duncan McKee
82d57a9f0f Add mfr fingerprints to Fibaro Motion
NVS-6
2017-05-23 16:08:47 -04:00
9 changed files with 35 additions and 88 deletions

View File

@@ -24,7 +24,10 @@ metadata {
capability "Temperature Measurement"
capability "Health Check"
fingerprint deviceId: "0x0701", inClusters: "0x5E, 0x20, 0x86, 0x72, 0x5A, 0x59, 0x85, 0x73, 0x84, 0x80, 0x71, 0x56, 0x70, 0x31, 0x8E, 0x22, 0x30, 0x9C, 0x98, 0x7A", outClusters: ""
fingerprint deviceId: "0x0701", inClusters: "0x5E, 0x20, 0x86, 0x72, 0x5A, 0x59, 0x85, 0x73, 0x84, 0x80, 0x71, 0x56, 0x70, 0x31, 0x8E, 0x22, 0x30, 0x9C, 0x98, 0x7A", outClusters: ""
fingerprint mfr:"010F", prod:"0801", model:"2001"
fingerprint mfr:"010F", prod:"0801", model:"1001"
}
simulator {

View File

@@ -1,2 +0,0 @@
.st-ignore
README.md

View File

@@ -1,48 +0,0 @@
# Aeon Multisensor
Cloud Execution
Works with:
* [Aeotec MultiSensor (DSB05-ZWUS)](https://www.smartthings.com/products/aeotec-multisensor-5)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Battery](#battery-specification)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Motion Sensor** - can detect motion
* **Temperature Measurement** - defines device measures current temperature
* **Relative Humidity Measurement** - allow reading the relative humidity from devices that support it
* **Illuminance Measurement** - gives the illuminance reading from devices that support it
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
* **Sensor** - detects sensor events
* **Battery** - defines device uses a battery
* **Health Check** - indicates ability to get device health notifications
## Device Health
Aeon Labs MultiSensor is polled by the hub.
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
* __32min__ checkInterval
## Battery Specification
Four AAA batteries are required.
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [Aeon MultiSensor Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206157226-How-to-connect-Aeon-Labs-MultiSensors)

View File

@@ -20,7 +20,6 @@ metadata {
capability "Illuminance Measurement"
capability "Sensor"
capability "Battery"
capability "Health Check"
fingerprint deviceId: "0x2001", inClusters: "0x30,0x31,0x80,0x84,0x70,0x85,0x72,0x86"
}
@@ -94,16 +93,6 @@ metadata {
}
}
def installed(){
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
def updated(){
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
// Parse incoming device messages to generate events
def parse(String description)
{
@@ -190,13 +179,6 @@ def zwaveEvent(physicalgraph.zwave.Command cmd) {
[:]
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
secure(zwave.batteryV1.batteryGet())
}
def configure() {
delayBetween([
// send binary sensor report instead of basic set for motion

View File

@@ -16,7 +16,7 @@
* Date: 2014-07-15
*/
metadata {
definition (name: "Aeon Siren", namespace: "smartthings", author: "SmartThings", ocfDeviceType: "x.com.st.d.sensor.smoke") {
definition (name: "Aeon Siren", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Alarm"
capability "Switch"

View File

@@ -47,14 +47,14 @@
capability "Sensor"
capability "Battery"
capability "Health Check"
command "resetParams2StDefaults"
command "listCurrentParams"
command "updateZwaveParam"
command "test"
command "configure"
command "resetParams2StDefaults"
command "listCurrentParams"
command "updateZwaveParam"
command "test"
command "configure"
fingerprint deviceId: "0x2001", inClusters: "0x30,0x84,0x85,0x80,0x8F,0x56,0x72,0x86,0x70,0x8E,0x31,0x9C,0xEF,0x30,0x31,0x9C"
fingerprint mfr:"010F", prod:"0800", model:"2001"
fingerprint mfr:"010F", prod:"0800", model:"1001"
}
simulator {

View File

@@ -29,7 +29,6 @@ metadata {
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3200", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "3200-Sgb", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019", manufacturer: "CentraLite", model: "4257050-RZHAC", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 000F, 0B04", outClusters: "0019", manufacturer: "SmartThings", model: "outletv4", deviceJoinName: "Outlet"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0B04,0B05", outClusters: "0019"
}

View File

@@ -27,6 +27,7 @@ metadata {
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0702"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0702, 0B05", outClusters: "0003, 000A, 0019", manufacturer: "Jasco Products", model: "45853", deviceJoinName: "GE ZigBee Plug-In Switch"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0702, 0B05", outClusters: "000A, 0019", manufacturer: "Jasco Products", model: "45856", deviceJoinName: "GE ZigBee In-Wall Switch"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 000F, 0B04", outClusters: "0019", manufacturer: "SmartThings", model: "outletv4", deviceJoinName: "Outlet"
}
tiles(scale: 2) {

View File

@@ -152,6 +152,10 @@ def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityCommandsSupported
def zwaveEvent(DoorLockOperationReport cmd) {
def result = []
unschedule(followupStateCheck)
unschedule(stateCheck)
def map = [ name: "lock" ]
if (cmd.doorLockMode == 0xFF) {
map.value = "locked"
@@ -365,7 +369,7 @@ def zwaveEvent(UserCodeReport cmd) {
code = state["set$name"] ?: decrypt(state[name]) ?: "****"
state.remove("set$name".toString())
} else {
map = [ name: "codeReport", value: cmd.userIdentifier, data: [ code: code ] ]
map = [ name: "codeReport", value: cmd.userIdentifier, data: [ code: code ], isStateChange: true ]
map.descriptionText = "$device.displayName code $cmd.userIdentifier is set"
map.displayed = (cmd.userIdentifier != state.requestCode && cmd.userIdentifier != state.pollCode)
map.isStateChange = true
@@ -456,11 +460,12 @@ def zwaveEvent(physicalgraph.zwave.commands.timev1.TimeGet cmd) {
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd) {
// The old Schlage locks use group 1 for basic control - we don't want that, so unsubscribe from group 1
def result = [ createEvent(name: "lock", value: cmd.value ? "unlocked" : "locked") ]
result << response(zwave.associationV1.associationRemove(groupingIdentifier:1, nodeId:zwaveHubNodeId))
if (state.assoc != zwaveHubNodeId) {
result << response(zwave.associationV1.associationGet(groupingIdentifier:2))
}
result
def cmds = [
zwave.associationV1.associationRemove(groupingIdentifier:1, nodeId:zwaveHubNodeId).format(),
"delay 1200",
zwave.associationV1.associationGet(groupingIdentifier:2).format()
]
[result, response(cmds)]
}
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
@@ -530,11 +535,18 @@ def unlockwtimeout() {
lockAndCheck(DoorLockOperationSet.DOOR_LOCK_MODE_DOOR_UNSECURED_WITH_TIMEOUT)
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
refresh()
runIn(30, followupStateCheck)
secure(zwave.doorLockV1.doorLockOperationGet())
}
def followupStateCheck() {
runEvery1Hour(stateCheck)
stateCheck()
}
def stateCheck() {
sendHubCommand(new physicalgraph.device.HubAction(secure(zwave.doorLockV1.doorLockOperationGet())))
}
def refresh() {