Compare commits

..

5 Commits

Author SHA1 Message Date
Garth Williams
62a264bbac MSA-2129: A device handler for the Devolo Humidity Sensor 2017-07-25 15:00:44 -07:00
Jack Chi
47eedf5770 Merge pull request #2170 from pchomal/hc_changes
[DHF-14][DHF-15] Updated comments & rectified typo
2017-07-25 12:25:38 +05:30
Luke Ness
3d0dbc57a1 Merge pull request #2100 from gausnes/ZwaveSirenFix
BatteryGet has a format method not property
2017-07-24 16:05:36 -05:00
piyush.c
f96ae94d12 [DHF-14][DHF-15] Health Check Aeon Key Fob and Aeon Minimote 2017-07-19 14:18:32 +05:30
Luke Ness
5e787dd0e3 BatteryGet has a format method not property 2017-06-19 11:59:13 -05:00
5 changed files with 193 additions and 210 deletions

View File

@@ -1,204 +0,0 @@
/**
* FortrezZ Flow Meter Interface
*
* Copyright 2016 FortrezZ, LLC
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
* Based on Todd Wackford's MimoLite Garage Door Opener
*/
metadata {
// Automatically generated. Make future change here.
definition (name: "FortrezZ MIMOlite", namespace: "fortrezz", author: "FortrezZ, LLC") {
capability "Configuration"
capability "Switch"
capability "Refresh"
capability "Contact Sensor"
capability "Voltage Measurement"
attribute "powered", "string"
command "on"
command "off"
fingerprint deviceId: "0x1000", inClusters: "0x72,0x86,0x71,0x30,0x31,0x35,0x70,0x85,0x25,0x03"
}
simulator {
// Simulator stuff
}
preferences {
input "RelaySwitchDelay", "decimal", title: "Delay between relay switch on and off in seconds. Only Numbers 0 to 3.0 allowed. 0 value will remove delay and allow relay to function as a standard switch", description: "Numbers 0 to 3.1 allowed.", defaultValue: 0, required: false, displayDuringSetup: true
}
// UI tile definitions
tiles (scale: 2) {
standardTile("switch", "device.switch", width: 4, height: 4, canChangeIcon: false, decoration: "flat") {
state "on", label: "On", action: "off", icon: "http://swiftlet.technology/wp-content/uploads/2016/06/Switch-On-104-edit.png", backgroundColor: "#53a7c0"
state "off", label: 'Off', action: "on", icon: "http://swiftlet.technology/wp-content/uploads/2016/06/Switch-Off-104-edit.png", backgroundColor: "#ffffff"
}
standardTile("contact", "device.contact", width: 2, height: 2, inactiveLabel: false) {
state "open", label: '${name}', icon: "st.contact.contact.open", backgroundColor: "#ffa81e"
state "closed", label: '${name}', icon: "st.contact.contact.closed", backgroundColor: "#79b821"
}
standardTile("refresh", "device.switch", width: 2, height: 2, inactiveLabel: false, decoration: "flat") {
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
}
standardTile("powered", "device.powered", width: 2, height: 2, inactiveLabel: false) {
state "powerOn", label: "Power On", icon: "st.switches.switch.on", backgroundColor: "#79b821"
state "powerOff", label: "Power Off", icon: "st.switches.switch.off", backgroundColor: "#ffa81e"
}
standardTile("configure", "device.configure", width: 2, height: 2, inactiveLabel: false, decoration: "flat") {
state "configure", label:'', action:"configuration.configure", icon:"st.secondary.configure"
}
valueTile("voltage", "device.voltage", width: 2, height: 2) {
state "val", label:'${currentValue}v', unit:"", defaultState: true
}
valueTile("voltageCounts", "device.voltageCounts", width: 2, height: 2) {
state "val", label:'${currentValue}', unit:"", defaultState: true
}
main (["switch"])
details(["switch", "contact", "voltage", "powered", "refresh","configure"])
}
}
def parse(String description) {
//log.debug "description is: ${description}"
def result = null
def cmd = zwave.parse(description, [0x20: 1, 0x84: 1, 0x30: 1, 0x70: 1, 0x31: 5])
//log.debug "command value is: $cmd.CMD"
if (cmd.CMD == "7105") { //Mimo sent a power loss report
log.debug "Device lost power"
sendEvent(name: "powered", value: "powerOff", descriptionText: "$device.displayName lost power")
} else {
sendEvent(name: "powered", value: "powerOn", descriptionText: "$device.displayName regained power")
}
//log.debug "${device.currentValue('contact')}" // debug message to make sure the contact tile is working
if (cmd) {
result = createEvent(zwaveEvent(cmd))
}
log.debug "Parse returned ${result?.descriptionText} $cmd.CMD"
return result
}
def updated() {
log.debug "Settings Updated..."
configure()
}
//notes about zwaveEvents:
// these are special overloaded functions which MUST be returned with a map similar to (return [name: "switch", value: "on"])
// not doing so will produce a null on the parse function, this will mess you up in the future.
// Perhaps can use 'createEvent()' and return that as long as a map is inside it.
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd) {
log.debug "switchBinaryReport ${cmd}"
if (cmd.value) // if the switch is on it will not be 0, so on = true
{
return [name: "switch", value: "on"] // change switch value to on
}
else // if the switch sensor report says its off then do...
{
return [name: "switch", value: "off"] // change switch value to off
}
}
// working on next for the analogue and digital stuff.
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd) // basic set is essentially our digital sensor for SIG1
{
log.debug "sent a BasicSet command"
//refresh()
delayBetween([zwave.sensorMultilevelV5.sensorMultilevelGet().format()])// requests a report of the anologue input voltage
[name: "contact", value: cmd.value ? "open" : "closed"]}
//[name: "contact", value: cmd.value ? "open" : "closed", type: "digital"]}
def zwaveEvent(physicalgraph.zwave.commands.sensorbinaryv1.SensorBinaryReport cmd)
{
log.debug "sent a sensorBinaryReport command"
refresh()
[name: "contact", value: cmd.value ? "open" : "closed"]
}
def zwaveEvent (physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd) // sensorMultilevelReport is used to report the value of the analog voltage for SIG1
{
log.debug "sent a SensorMultilevelReport"
def ADCvalue = cmd.scaledSensorValue
sendEvent(name: "voltageCounts", value: ADCvalue)
CalculateVoltage(cmd.scaledSensorValue)
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
// Handles all Z-Wave commands we aren't interested in
log.debug("Un-parsed Z-Wave message ${cmd}")
[:]
}
def CalculateVoltage(ADCvalue)
{
def map = [:]
def volt = (((1.5338*(10**-16))*(ADCvalue**5)) - ((1.2630*(10**-12))*(ADCvalue**4)) + ((3.8111*(10**-9))*(ADCvalue**3)) - ((4.7739*(10**-6))*(ADCvalue**2)) + ((2.8558*(10**-3))*(ADCvalue)) - (2.2721*(10**-2)))
//def volt = (((3.19*(10**-16))*(ADCvalue**5)) - ((2.18*(10**-12))*(ADCvalue**4)) + ((5.47*(10**-9))*(ADCvalue**3)) - ((5.68*(10**-6))*(ADCvalue**2)) + (0.0028*ADCvalue) - (0.0293))
//log.debug "$cmd.scale $cmd.precision $cmd.size $cmd.sensorType $cmd.sensorValue $cmd.scaledSensorValue"
def voltResult = volt.round(1)// + "v"
map.name = "voltage"
map.value = voltResult
map.unit = "v"
return map
}
def configure() {
def x = (RelaySwitchDelay*10).toInteger()
log.debug "Configuring.... " //setting up to monitor power alarm and actuator duration
delayBetween([
zwave.associationV1.associationSet(groupingIdentifier:3, nodeId:[zwaveHubNodeId]).format(), // FYI: Group 3: If a power dropout occurs, the MIMOlite will send an Alarm Command Class report
// (if there is enough available residual power)
zwave.associationV1.associationSet(groupingIdentifier:2, nodeId:[zwaveHubNodeId]).format(), // periodically send a multilevel sensor report of the ADC analog voltage to the input
zwave.associationV1.associationSet(groupingIdentifier:4, nodeId:[zwaveHubNodeId]).format(), // when the input is digitally triggered or untriggered, snd a binary sensor report
zwave.configurationV1.configurationSet(configurationValue: [x], parameterNumber: 11, size: 1).format() // configurationValue for parameterNumber means how many 100ms do you want the relay
// to wait before it cycles again / size should just be 1 (for 1 byte.)
//zwave.configurationV1.configurationGet(parameterNumber: 11).format() // gets the new parameter changes. not currently needed. (forces a null return value without a zwaveEvent funciton
])
}
def on() {
delayBetween([
zwave.basicV1.basicSet(value: 0xFF).format(), // physically changes the relay from on to off and requests a report of the relay
refresh()// to make sure that it changed (the report is used elsewhere, look for switchBinaryReport()
])
}
def off() {
delayBetween([
zwave.basicV1.basicSet(value: 0x00).format(), // physically changes the relay from on to off and requests a report of the relay
refresh()// to make sure that it changed (the report is used elsewhere, look for switchBinaryReport()
])
}
def refresh() {
log.debug "REFRESH!"
delayBetween([
zwave.switchBinaryV1.switchBinaryGet().format(), //requests a report of the relay to make sure that it changed (the report is used elsewhere, look for switchBinaryReport()
zwave.sensorMultilevelV5.sensorMultilevelGet().format()// requests a report of the anologue input voltage
])
}

View File

@@ -0,0 +1,188 @@
/**
* Devolo Humidity Sensor
*
* Copyright 2017 Garth Williams
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
*
* Based on definition (name: "Aeon Multisensor 6", namespace: "smartthings", author: "SmartThings")
*
*/
metadata {
definition (name: "Devolo Humidity Sensor", namespace: "garth", author: "Garth Williams") {
capability "Temperature Measurement"
capability "Relative Humidity Measurement"
capability "Configuration"
capability "Sensor"
capability "Battery"
capability "Health Check"
attribute "batteryStatus", "string"
fingerprint mfr: "0175", prod: "0002", model: "0020"
}
simulator {
for (int i = 0; i <= 100; i += 20) {
status "temperature ${i}F": new physicalgraph.zwave.Zwave().securityV1.securityMessageEncapsulation().encapsulate(
new physicalgraph.zwave.Zwave().sensorMultilevelV2.sensorMultilevelReport(
scaledSensorValue: i, precision: 1, sensorType: 1, scale: 1)
).incomingMessage()
}
for (int i = 0; i <= 100; i += 20) {
status "humidity ${i}%": new physicalgraph.zwave.Zwave().securityV1.securityMessageEncapsulation().encapsulate(
new physicalgraph.zwave.Zwave().sensorMultilevelV2.sensorMultilevelReport(scaledSensorValue: i, sensorType: 5)
).incomingMessage()
}
for (int i in [0, 5, 10, 15, 50, 99, 100]) {
status "battery ${i}%": new physicalgraph.zwave.Zwave().securityV1.securityMessageEncapsulation().encapsulate(
new physicalgraph.zwave.Zwave().batteryV1.batteryReport(batteryLevel: i)
).incomingMessage()
}
status "low battery alert": new physicalgraph.zwave.Zwave().securityV1.securityMessageEncapsulation().encapsulate(
new physicalgraph.zwave.Zwave().batteryV1.batteryReport(batteryLevel: 255)
).incomingMessage()
status "wake up" : "command: 8407, payload: "
}
preferences {
}
tiles(scale: 2) {
valueTile("temperature", "device.temperature", inactiveLabel: false, width: 2, height: 2) {
state "temperature", label:'${currentValue}°',
backgroundColors:[
[value: 32, color: "#153591"],
[value: 44, color: "#1e9cbb"],
[value: 59, color: "#90d2a7"],
[value: 74, color: "#44b621"],
[value: 84, color: "#f1d801"],
[value: 92, color: "#d04e00"],
[value: 98, color: "#bc2323"]
]
}
valueTile("humidity", "device.humidity", inactiveLabel: false, width: 2, height: 2) {
state "humidity", label:'${currentValue}% humidity', unit:""
}
valueTile("battery", "device.battery", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "battery", label:'${currentValue}% battery', unit:""
}
valueTile("batteryStatus", "device.batteryStatus", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "batteryStatus", label:'${currentValue}', unit:""
}
main(["temperature", "humidity"])
details(["temperature", "humidity", "batteryStatus"])
}
}
def parse(String description) {
log.debug "parse() >> description: $description"
def result = null
if (description.startsWith("Err 106")) {
log.debug "parse() >> Err 106"
result = createEvent( name: "secureInclusion", value: "failed", isStateChange: true,
descriptionText: "This sensor failed to complete the network security key exchange. If you are unable to control it via SmartThings, you must remove it from your network and add it again.")
} else if (description != "updated") {
log.debug "parse() >> zwave.parse(description)"
def cmd = zwave.parse(description, [0x31: 5, 0x30: 2, 0x84: 1])
if (cmd) {
result = zwaveEvent(cmd)
}
}
log.debug "After zwaveEvent(cmd) >> Parsed '${description}' to ${result.inspect()}"
return result
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand([0x31: 5, 0x30: 2, 0x84: 1])
state.sec = 1
log.debug "encapsulated: ${encapsulatedCommand}"
if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
} else {
log.warn "Unable to extract encapsulated cmd from $cmd"
createEvent(descriptionText: cmd.toString())
}
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityCommandsSupportedReport cmd) {
log.info "Executing zwaveEvent 98 (SecurityV1): 03 (SecurityCommandsSupportedReport) with cmd: $cmd"
state.sec = 1
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.NetworkKeyVerify cmd) {
state.sec = 1
log.info "Executing zwaveEvent 98 (SecurityV1): 07 (NetworkKeyVerify) with cmd: $cmd (node is securely included)"
def result = [createEvent(name:"secureInclusion", value:"success", descriptionText:"Secure inclusion was successful", isStateChange: true)]
result
}
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def result = []
def map = [ name: "battery", unit: "%" ]
if (cmd.batteryLevel == 0xFF) {
map.value = 1
map.descriptionText = "${device.displayName} battery is low"
map.isStateChange = true
} else {
map.value = cmd.batteryLevel
}
state.lastbatt = now()
result << createEvent(map)
if (device.latestValue("powerSupply") != "USB Cable"){
result << createEvent(name: "batteryStatus", value: "${map.value} % battery", displayed: false)
}
result
}
def zwaveEvent(physicalgraph.zwave.commands.sensormultilevelv5.SensorMultilevelReport cmd){
def map = [:]
switch (cmd.sensorType) {
case 1:
map.name = "temperature"
def cmdScale = cmd.scale == 1 ? "F" : "C"
map.value = convertTemperatureIfNeeded(cmd.scaledSensorValue, cmdScale, cmd.precision)
map.unit = getTemperatureScale()
break
case 5:
map.name = "humidity"
map.value = cmd.scaledSensorValue.toInteger()
map.unit = "%"
break
default:
map.descriptionText = cmd.toString()
}
createEvent(map)
}
def zwaveEvent(physicalgraph.zwave.commands.configurationv2.ConfigurationReport cmd) {
log.debug "ConfigurationReport: $cmd"
def result = []
def value
if (cmd.parameterNumber == 9 && cmd.configurationValue[0] == 1) {
value = "Battery"
result << createEvent(name: "powerSupply", value: value, displayed: false)
} else if (cmd.parameterNumber == 101){
result << response(configure())
}
result
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
log.debug "General zwaveEvent cmd: ${cmd}"
createEvent(descriptionText: cmd.toString(), isStateChange: false)
}

View File

@@ -133,8 +133,8 @@ def updated() {
}
def initialize() {
// Arrival sensors only goes OFFLINE when Hub is off
sendEvent(name: "DeviceWatch-Enroll", value: JsonOutput.toJson([protocol: "zigbee", scheme:"untracked"]), displayed: false)
// Device only goes OFFLINE when Hub is off
sendEvent(name: "DeviceWatch-Enroll", value: JsonOutput.toJson([protocol: "zwave", scheme:"untracked"]), displayed: false)
def zwMap = getZwaveInfo()
def buttons = 4 // Default for Key Fob

View File

@@ -111,7 +111,6 @@ def configure() {
return cmds
}
def installed() {
initialize()
}
@@ -121,7 +120,7 @@ def updated() {
}
def initialize() {
// Arrival sensors only goes OFFLINE when Hub is off
sendEvent(name: "DeviceWatch-Enroll", value: JsonOutput.toJson([protocol: "zigbee", scheme:"untracked"]), displayed: false)
// Device only goes OFFLINE when Hub is off
sendEvent(name: "DeviceWatch-Enroll", value: JsonOutput.toJson([protocol: "zwave", scheme:"untracked"]), displayed: false)
sendEvent(name: "numberOfButtons", value: 4)
}

View File

@@ -72,7 +72,7 @@ def createEvents(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def poll() {
if (secondsPast(state.lastbatt, 36*60*60)) {
return zwave.batteryV1.batteryGet().format
return zwave.batteryV1.batteryGet().format()
} else {
return null
}