Compare commits

..

9 Commits

Author SHA1 Message Date
Dillon Miller
2b040d9ae8 MSA-1184: A device handler for Aeotec Model zw095-a Home Energy Monitor. I have been using it for several weeks and have enhanced and refined it to the point where it is ready for general use by others. This device handler has been posted on the support site of the manufacturer.
https://aeotec.freshdesk.com/support/solutions/articles/6000122372-using-hem-gen5-with-smartthings-hub-s-custom-device-type

Thanks,
-Dillon
2016-04-15 11:15:57 -05:00
Yaima
33ef75091b Merge pull request #783 from Yaima/master
Fixes broken htmlTile
2016-04-14 16:05:55 -07:00
Yaima Valdivia
1bcad614ec Fixes broken htmlTile 2016-04-14 16:03:58 -07:00
Luke Bredeson
3ab83350f3 Merge pull request #761 from lbredeso/hue-event-subscription-improvements
EX-3: Improve Hue (Connect) event subscriptions
2016-04-14 16:58:01 -05:00
Vinay Rao
d91fea89df Merge pull request #779 from SmartThingsCommunity/staging
Rolling down hotfix from staging to master
2016-04-13 23:28:57 -05:00
Vinay Rao
d28d27c4ed Merge pull request #778 from SmartThingsCommunity/production
Rolling down hotfix from production to staging
2016-04-13 22:34:01 -05:00
Dylan Bijnagte
be8c84306a Merge pull request #770 from Bijnagte/INTL-525
INTL-525 translation refresh
2016-04-11 15:57:46 -05:00
dylanbijnagte
a6105188ea INTL-525 translation refresh 2016-04-11 13:44:40 -05:00
Luke Bredeson
237d6a79e9 EX-3: Improve Hue (Connect) event subscriptions 2016-04-05 13:28:45 -05:00
10 changed files with 616 additions and 68 deletions

View File

@@ -0,0 +1,442 @@
/*
* Aeon HEM Gen5(zwave plus)
*
* Copyright 2016 Dillon A. Miller
*
* v0.8 of Aeon HEM Gen5(zwave plus) code, released 04/15/2016 for Aeotec Model zw095-a
* This Gen5 device handler is not backward compatible with the Aeon V1 or V2 device. If your model number is not zw095-a, don't use it.
*
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
* in compliance with the License. You may obtain a copy of the License at:
*
* http://www.apache.org/licenses/LICENSE-2.0
*
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
* for the specific language governing permissions and limitations under the License.
*
* Some code used from various SmartThings device handlers created by:
* Brock Haymond, Barry A. Burke, and Robert Vandervoort. Portions of the metering code came from ElasticDev.
*
* Link to find the latest version of the Device Handler code:
* https://gist.github.com/DuncanIdahoCT/deb2bafdd28af4fce3073b9d9f4ecafa
*
* General notes:
* You may need to change the device type to this device handler after you pair it to your hub. I'm not sure why it doesn't always automatically pair using this handler even though the fingerprint matches...
* Also, you need to hit the button on the back of the HEM Gen5 a couple (two-three) times to get it to flash the red light on the front rapidly to ensure it's in inclusion mode. It isn't in the right mode if it's just flashing slow.
* Once the red light is solid, look in your things list and find it, could be just called z-wave, then change it's name and device type using the graph api to this custom handler to make it start working.
* The config with default intervals will send right away after you set the HEM Gen5 to this handler, please wait a few minutes before sending the config again or changing the intervals under preferences.
* The purpose of the config button is just really to resend the config with monitor interval prefs, as sometimes the config isn't fully applied, See the list of config items at the bottom of this code.
* You may need to send the config a few times, with about 2 minutes delay between to get all the properties to take. Not sure why-but if you look in the debug log in the graph api for this device you can see if they all applied.
* I had to unplug and replug my device after extensive testing and repeatedly setting the config over and over. Could be it works for you the first time, or you may need to pull power and re plug too in order to get all the Pole 1/2 data to show in the app.
*
* Known Issues:
* Issue 1:
* Not sure if this is the device handler or just a general SmartThings IOS App issue but sometimes when you set the preferences, it just spins in the app.
* If you are watching the log you can see it did set the preferences. Not sure why the app gets stuck, but just reload the app and should be fine.
* Issue 2:
* Not really a problem, more like a limitation; the clamps 1/2 data packets are sent to the ST hub based on monitor intervals for reports groups 1-3 which you can set in the device preferences.
* What this means is that, if you are paying attention to the tile data, you'll notice the center Total values don't quite work out to be the sum of Pole 1/2 values.
* This is simply because the base HEM data can be "polled" whereas the clamp 1/2 data is sent. And only sent on a schedule.
*
* Change log:
* v0.1 - released 04/04/16:
* Added support for secure inclusion and command encapsulation
* v0.2 - released 04/05/16:
* Added configuration settings using some preference variables that you can control from the app
* v0.3 - released 04/05/16:
* Added clamp1 and clamp2 data display, may have to hit configure a few times (wait at least 2 minute each time) to make the top left and right boxes show data from the clamps.
* v0.4 - released 04/06/16:
* Changed the "main" tile to display a clean total kWh, although the ST app seems to make everything on the main Things list all CAPS so it's actually displayed as KWH...
* v0.5 - released 04/07/16:
* Changed the main thing list device icon to st.Lighting.light14 cause it has a leaf!.
* v0.6 - released 04/07/16:
* Added a cost per kWh preference and a cost tile that is calculated on kWh.
* Also added a timestamp of last reset button tap to work with above cost feature.
* v0.7 - released 04/08/16:
* Removed individual value tile polling actions and polling function.
* Cleaned up and well-formed code
* v0.8 - released 04/15/16:
* Slightly adjusted the size of the tiles to fit all tiles into the App screen without scrolling.
* Further commented and cleaned up the code in preparation for submission to SmartThings as an official device handler.
* Submitted for consideration by SmartThings.
*
* To do:
* Features:
* Color code tiles or tile values for hi/low usage conditions.
* Possibly integrate a second tile set page with peak/min usage of watts and/or amps values over time.
* Integrate PlotWatt or other online Energy tracking API based service.
* Fixes:
* Determine why app sometimes freezes when setting preferences, I have seen this with other devices, e.g. Arrival Sensor, Jasco Wall Switches, etc...
*
*/
// metadata
metadata {
definition (name: "Aeon HEM Gen5(zwave plus)", namespace: "DuncanIdahoCT", author: "Dillon A. Miller") {
capability "Energy Meter"
capability "Power Meter"
capability "Configuration"
capability "Polling"
capability "Refresh"
capability "Sensor"
command "reset"
fingerprint deviceId: "0x3101", inClusters: "0x98"
fingerprint inClusters: "0x5E,0x86,0x72,0x32,0x56,0x60,0x70,0x59,0x85,0x7A,0x73,0xEF,0x5A", outClusters: "0x82"
}
// simulator
simulator {
for (int i = 0; i <= 10000; i += 1000) {
status "power ${i} W":
new physicalgraph.zwave.Zwave().meterV3.meterReport(scaledMeterValue: i, precision: 3, meterType: 1, scale: 2, size: 4).incomingMessage()
}
for (int i = 0; i <= 100; i += 10) {
status "energy ${i} kWh":
new physicalgraph.zwave.Zwave().meterV3.meterReport(scaledMeterValue: i, precision: 3, meterType: 1, scale: 0, size: 4).incomingMessage()
}
}
// tile definitions
tiles (scale: 2) {
// This tile is not displayed on the tile screen for this device but rather in the Things list.
valueTile("list-energy", "device.energy") {
state "default", label:'${currentValue} kWh', icon: "st.Lighting.light14"
}
// Tiles with a digit below relate to Clamp 1 and Clamp 2. Tiles with no digit are totals for clamps or volts.
valueTile("current1", "device.current1", decoration: "flat", width: 2, height: 2) {
state "default", label:'Pole 1\n${currentValue}\nAmps'
}
valueTile("current", "device.current", decoration: "flat", width: 2, height: 2) {
state "default", label:'Total\n${currentValue}\nAmps'
}
valueTile("current2", "device.current2", decoration: "flat", width: 2, height: 2) {
state "default", label:'Pole 2\n${currentValue}\nAmps'
}
valueTile("power1", "device.power1", decoration: "flat", width: 2, height: 2) {
state "default", label:'Pole 1\n${currentValue}\nWatts'
}
valueTile("power", "device.power", decoration: "flat", width: 2, height: 2) {
state "default", label:'Total\n${currentValue}\nWatts'
}
valueTile("power2", "device.power2", decoration: "flat", width: 2, height: 2) {
state "default", label:'Pole 2\n${currentValue}\nWatts'
}
valueTile("voltage", "device.voltage", decoration: "flat", width: 2, height: 1) {
state "default", label:'${currentValue} V'
}
valueTile("energy", "device.energy", decoration: "flat", width: 2, height: 1) {
state "default", label:'${currentValue} kWh'
}
valueTile("cost", "device.cost", decoration: "flat", width: 2, height: 1) {
state "default", label:'\$${currentValue}'
}
valueTile("lastresetlabel", "device.lastresettime", decoration: "flat", width: 3, height: 1) {
state "default", label:'Last Reset Timestamp'
}
valueTile("lastresettime", "device.lastresettime", decoration: "flat", width: 3, height: 1) {
state "default", label:'${currentValue}'
}
standardTile("configure", "device.power", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "configure", label:'', action:"configuration.configure", icon:"st.secondary.configure"
}
standardTile("reset", "device.energy", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "default", label:'reset kWh', action:"reset"
}
standardTile("refresh", "device.power", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
}
main "list-energy"
details(["current1","current","current2","power1","power","power2","voltage","energy","cost","lastresetlabel","lastresettime","configure","reset","refresh"])
}
preferences {
input "kWhCost", "string",
title: "Cost in \$/kWh",
description: "Your Electric Bill Cost Per kWh",
defaultValue: "0.19514" as String,
required: false,
displayDuringSetup: true
input "monitorInterval1", "integer",
title: "Volts & kWh Report",
description: "Interval (secs) for Volts & kWh Report",
defaultValue: 60,
range: "1..4294967295?",
required: false,
displayDuringSetup: true
input "monitorInterval2", "integer",
title: "Amps Report",
description: "Interval (secs) for Amps Report",
defaultValue: 30,
range: "1..4294967295?",
required: false,
displayDuringSetup: true
input "monitorInterval3", "integer",
title: "Watts Report",
description: "Interval (secs) for Watts Report",
defaultValue: 6,
range: "1..4294967295?",
required: false,
displayDuringSetup: true
}
}
def updated(){
if (state.sec && !isConfigured()) {
// in case we miss the SCSR
response(configure())
}
}
def parse(String description){
def result = null
if (description.startsWith("Err 106")) {
state.sec = 0
result = createEvent( name: "secureInclusion", value: "failed", isStateChange: true,
descriptionText: "This sensor failed to complete the network security key exchange. If you are unable to control it via SmartThings, you must remove it from your network and add it again.")
} else if (description != "updated") {
def cmd = zwave.parse(description, [0x32: 3, 0x56: 1, 0x59: 1, 0x5A: 1, 0x60: 3, 0x70: 1, 0x72: 2, 0x73: 1, 0x82: 1, 0x85: 2, 0x86: 2, 0x8E: 2, 0xEF: 1])
if (cmd) {
result = zwaveEvent(cmd)
}
}
//log.debug "Parsed '${description}' to ${result.inspect()}"
return result
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand([0x32: 3, 0x56: 1, 0x59: 1, 0x5A: 1, 0x60: 3, 0x70: 1, 0x72: 2, 0x73: 1, 0x82: 1, 0x85: 2, 0x86: 2, 0x8E: 2, 0xEF: 1])
state.sec = 1
//log.debug "encapsulated: ${encapsulatedCommand}"
if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
} else {
log.warn "Unable to extract encapsulated cmd from $cmd"
createEvent(descriptionText: cmd.toString())
}
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityCommandsSupportedReport cmd) {
response(configure())
}
def zwaveEvent(physicalgraph.zwave.commands.configurationv1.ConfigurationReport cmd) {
log.debug "---CONFIGURATION REPORT V1--- ${device.displayName} parameter ${cmd.parameterNumber} with a byte size of ${cmd.size} is set to ${cmd.configurationValue}"
}
def zwaveEvent(physicalgraph.zwave.commands.associationv2.AssociationReport cmd) {
log.debug "---ASSOCIATION REPORT V2--- ${device.displayName} groupingIdentifier: ${cmd.groupingIdentifier}, maxNodesSupported: ${cmd.maxNodesSupported}, nodeId: ${cmd.nodeId}, reportsToFollow: ${cmd.reportsToFollow}"
}
def zwaveEvent(physicalgraph.zwave.commands.meterv3.MeterReport cmd) {
def meterTypes = ["Unknown", "Electric", "Gas", "Water"]
def electricNames = ["energy", "energy", "power", "count", "voltage", "current", "powerFactor", "unknown"]
def electricUnits = ["kWh", "kVAh", "W", "pulses", "V", "A", "Power Factor", ""]
//NOTE ScaledPreviousMeterValue does not always contain a value
def previousValue = cmd.scaledPreviousMeterValue ?: 0
//Here is where all HEM polled values are defined. Scale(0-7) is in reference to the Aeon Labs HEM Gen5 data for kWh, kVAh, W, V, A, and M.S.T. respectively.
//If scale 7 (M.S.T.) is polled, you would receive Scale2(0-1) which is kVar, and kVarh respectively. We are ignoring the Scale2 ranges in this device handler.
def map = [ name: electricNames[cmd.scale], unit: electricUnits[cmd.scale], displayed: state.display]
switch(cmd.scale) {
case 0: //kWh
previousValue = device.currentValue("energy") ?: cmd.scaledPreviousMeterValue ?: 0
BigDecimal costDecimal = cmd.scaledMeterValue * (kWhCost as BigDecimal)
def costDisplay = String.format("%5.2f",costDecimal)
sendEvent(name: "cost", value: costDisplay, unit: "", descriptionText: "Display Cost: \$${costDisp}")
map.value = cmd.scaledMeterValue
break;
case 1: //kVAh (not used in the U.S.)
map.value = cmd.scaledMeterValue
break;
case 2: //Watts
previousValue = device.currentValue("power") ?: cmd.scaledPreviousMeterValue ?: 0
map.value = Math.round(cmd.scaledMeterValue)
break;
case 3: //pulses
map.value = Math.round(cmd.scaledMeterValue)
break;
case 4: //Volts
previousValue = device.currentValue("voltage") ?: cmd.scaledPreviousMeterValue ?: 0
map.value = cmd.scaledMeterValue
break;
case 5: //Amps
previousValue = device.currentValue("current") ?: cmd.scaledPreviousMeterValue ?: 0
map.value = cmd.scaledMeterValue
break;
case 6: //Power Factor
case 7: //Scale2 values (not currently implimented or needed)
map.value = cmd.scaledMeterValue
break;
default:
break;
}
createEvent(map)
}
def zwaveEvent(physicalgraph.zwave.commands.multichannelv3.MultiChannelCmdEncap cmd) {
//This is where the HEM clamp1 and clamp2 (subdevice) report values are defined. Scale(2,5) is in reference to the Aeon Labs HEM Gen5 (subdevice) data for W, and A respectively.
//Z-Wave Command Class 0x60 (multichannelv3) is necessary to interpret the subdevice data from the HEM clamps.
//In addition, "cmd.commandClass == 50" and "encapsulatedCommand([0x30: 1, 0x31: 1])" below is necessary to properly receive and inturpret the encasulated subdevice data sent to the SmartThings hub by the HEM.
//The numbered "command class" references: 50, 0x30v1, and 0x31v1 do not seem to be true Z-Wave Command Classes and any correlation is seemingly coincidental.
//It should also be noted that without the above, the data received will not be processed here under the 0x60 (multichannelv3) command class and you will see unhandled messages from the HEM along with references to command class 50 as well as Meter Types 33, and 161.
//sourceEndPoint 1, and 2 are the Clamps 1, and 2.
def dispValue
def newValue
def formattedValue
def MAX_AMPS = 220
def MAX_WATTS = 24000
if (cmd.commandClass == 50) { //50 is likely a manufacturer specific code, Z-Wave specifies this as a "Basic Window Covering" so it's not a true Z-Wave Command Class.
def encapsulatedCommand = cmd.encapsulatedCommand([0x30: 1, 0x31: 1]) // The documentation on working with Z-Wave subdevices and the technical specs from Aeon Labs do not explain this adequately, but it's necessary.
//log.debug ("Command from endpoint ${cmd.sourceEndPoint}: ${encapsulatedCommand}")
if (encapsulatedCommand) {
if (cmd.sourceEndPoint == 1) {
if (encapsulatedCommand.scale == 2 ) {
newValue = Math.round(encapsulatedCommand.scaledMeterValue)
if (newValue > MAX_WATTS) { return }
formattedValue = newValue
dispValue = "${formattedValue}"
sendEvent(name: "power1", value: dispValue as String, unit: "", descriptionText: "L1 Power: ${formattedValue} Watts")
}
if (encapsulatedCommand.scale == 5 ) {
newValue = Math.round(encapsulatedCommand.scaledMeterValue * 100) / 100
if (newValue > MAX_AMPS) { return }
formattedValue = String.format("%5.2f", newValue)
dispValue = "${formattedValue}"
sendEvent(name: "current1", value: dispValue as String, unit: "", descriptionText: "L1 Current: ${formattedValue} Amps")
}
}
else if (cmd.sourceEndPoint == 2) {
if (encapsulatedCommand.scale == 2 ) {
newValue = Math.round(encapsulatedCommand.scaledMeterValue)
if (newValue > MAX_WATTS) { return }
formattedValue = newValue
dispValue = "${formattedValue}"
sendEvent(name: "power2", value: dispValue as String, unit: "", descriptionText: "L2 Power: ${formattedValue} Watts")
}
if (encapsulatedCommand.scale == 5 ) {
newValue = Math.round(encapsulatedCommand.scaledMeterValue * 100) / 100
if (newValue > MAX_AMPS) { return }
formattedValue = String.format("%5.2f", newValue)
dispValue = "${formattedValue}"
sendEvent(name: "current2", value: dispValue as String, unit: "", descriptionText: "L2 Current: ${formattedValue} Amps")
}
}
}
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
//This will log any unhandled command output to the debug window.
log.debug "Unhandled: $cmd"
createEvent(descriptionText: cmd.toString(), isStateChange: false)
}
def refresh() {
def request = [
//This is where the tile action "refresh" is defined. Refresh is very basic. It simply gets and displays the latest values from the HEM exclusive of the clamp subdevices.
zwave.meterV3.meterGet(scale: 0), //kWh
zwave.meterV3.meterGet(scale: 2), //Wattage
zwave.meterV3.meterGet(scale: 4), //Volts
zwave.meterV3.meterGet(scale: 5), //Amps
]
commands(request)
}
def reset() {
//This is where the tile action "reset" is defined. Reset is only meant to be used once a month on the end/beginning of your electric utility billing cycle.
//Tapping reset will send the meter reset command to HEM and zero out the kWh data so you can start fresh.
//This will also clear the cost data and reset the last reset timestamp. Finally it will poll for latest values from the HEM.
//This has no impact on Pole1 or Pole2 (clamp1 and clamp2 subdevice) tile data as that is sent via reports from the HEM.
def dateString = new Date().format("M/d/YY", location.timeZone)
def timeString = new Date().format("h:mm a", location.timeZone)
state.lastresettime = dateString+" @ "+timeString
sendEvent(name: "lastresettime", value: state.lastresettime)
def request = [
zwave.meterV3.meterReset(),
zwave.meterV3.meterGet(scale: 0), //kWh
zwave.meterV3.meterGet(scale: 2), //Wattage
zwave.meterV3.meterGet(scale: 4), //Volts
zwave.meterV3.meterGet(scale: 5), //Amps
]
commands(request)
}
def configure() {
//This is where the tile action "configure" is defined. Configure resends the configuration commands below (using the variables set by the preferences section above) to the HEM Gen5 device.
//If you're watching the debug log when you tap configure, you should see the full configuration report come back slowly over about a minute.
//If you don't see the full configuration report (seven messages) followed by the association report, tap configure again.
def monitorInt1 = 60
if (monitorInterval1) {
monitorInt1=monitorInterval1.toInteger()
}
def monitorInt2 = 30
if (monitorInterval2) {
monitorInt2=monitorInterval2.toInteger()
}
def monitorInt3 = 6
if (monitorInterval3) {
monitorInt3=monitorInterval3.toInteger()
}
log.debug "Sending configure commands - kWhCost '${kWhCost}', monitorInterval1 '${monitorInt1}', monitorInterval2 '${monitorInt2}', monitorInterval3 '${monitorInt3}'"
def request = [
// Reset switch configuration to defaults.
//zwave.configurationV1.configurationSet(parameterNumber: 255, size: 1, scaledConfigurationValue: 1),
// Disable selective reporting, so always update based on schedule below <set to 1 to reduce network traffic>.
zwave.configurationV1.configurationSet(parameterNumber: 3, size: 1, scaledConfigurationValue: 1),
// (DISABLED by first option) Don't send unless watts have changed by 50 <default>.
zwave.configurationV1.configurationSet(parameterNumber: 4, size: 2, scaledConfigurationValue: 10),
// (DISABLED by first option) Or by 10% <default>.
zwave.configurationV1.configurationSet(parameterNumber: 8, size: 1, scaledConfigurationValue: 5),
// Which reports need to send in Report group 1.
zwave.configurationV1.configurationSet(parameterNumber: 101, size: 4, scaledConfigurationValue: 6149),
// Which reports need to send in Report group 2.
zwave.configurationV1.configurationSet(parameterNumber: 102, size: 4, scaledConfigurationValue: 1572872),
// Which reports need to send in Report group 3.
zwave.configurationV1.configurationSet(parameterNumber: 103, size: 4, scaledConfigurationValue: 770),
// Interval to send Report group 1.
zwave.configurationV1.configurationSet(parameterNumber: 111, size: 4, scaledConfigurationValue: monitorInt1),
// Interval to send Report group 2.
zwave.configurationV1.configurationSet(parameterNumber: 112, size: 4, scaledConfigurationValue: monitorInt2),
// Interval to send Report group 3.
zwave.configurationV1.configurationSet(parameterNumber: 113, size: 4, scaledConfigurationValue: monitorInt3),
// Report which configuration commands were sent to and received by the HEM Gen5 successfully.
zwave.configurationV1.configurationGet(parameterNumber: 3),
zwave.configurationV1.configurationGet(parameterNumber: 4),
zwave.configurationV1.configurationGet(parameterNumber: 8),
zwave.configurationV1.configurationGet(parameterNumber: 101),
zwave.configurationV1.configurationGet(parameterNumber: 102),
zwave.configurationV1.configurationGet(parameterNumber: 103),
zwave.configurationV1.configurationGet(parameterNumber: 111),
zwave.configurationV1.configurationGet(parameterNumber: 112),
zwave.configurationV1.configurationGet(parameterNumber: 113),
zwave.associationV2.associationGet(groupingIdentifier: 1)
]
commands(request)
}
private setConfigured() {
updateDataValue("configured", "true")
}
private isConfigured() {
getDataValue("configured") == "true"
}
private command(physicalgraph.zwave.Command cmd) {
if (state.sec) {
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
} else {
cmd.format()
}
}
private commands(commands, delay=500) {
delayBetween(commands.collect{ command(it) }, delay)
}

View File

@@ -23,14 +23,14 @@
#==============================================================================
# Korean (ko)
# Device Preferences
'''Give your device a name'''.ko=기기 이름 바꾸기
'''Give your device a name'''.ko=기기 이름 설정
'''Set Device Image'''.ko=기기 이미지 설정
'''Presence timeout (minutes)'''.ko=시간 초과. 스마트폰 위치 정보
'''Presence timeout (minutes)'''.ko=알람 유예 시간 설정 (분)
'''Tap to set'''.ko=눌러서 설정
'''Arrival Sensor'''.ko=도착알림 센서
'''${currentValue}% battery'''.ko=${currentValue}% 배터리
# Events / Notifications
'''{{ linkText }} battery was {{ value }}'''.ko={{ linkText }}남아있는 배터리 {{ value }}입니다.
'''{{ linkText }} has arrived'''.ko={{ linkText }}집에 도착했습니다.
'''{{ linkText }} has left'''.ko={{ linkText }}집을 나갔습니다.
'''{{ linkText }} battery was {{ value }}'''.ko={{ linkText }}의 남은 배터리 {{ value }}
'''{{ linkText }} has arrived'''.ko={{ linkText }} 귀가
'''{{ linkText }} has left'''.ko={{ linkText }} 외출
#==============================================================================

View File

@@ -23,10 +23,10 @@
#==============================================================================
# Korean (ko)
# Device Preferences
'''Give your device a name'''.ko=기기 이름 바꾸기
'''Give your device a name'''.ko=기기 이름 설정
'''Set Device Image'''.ko=기기 이미지 설정
# Events / Notifications
'''{{ linkText }} has left'''.ko={{ linkText }}집을 나갔습니다.
'''{{ linkText }} has arrived'''.ko={{ linkText }}집에 도착했습니다.
'''{{ linkText }} has left'''.ko={{ linkText }} 외출
'''{{ linkText }} has arrived'''.ko={{ linkText }} 귀가
'''present'''.ko=집안
'''not present'''.ko=외출

View File

@@ -22,14 +22,14 @@
#==============================================================================
# Korean (ko)
# Device Preferences
'''Give your device a name'''.ko=기기 이름 바꾸기
'''Outlet'''.ko=플러그
'''Give your device a name'''.ko=기기 이름 설정
'''Outlet'''.ko= 스마트 플러그
# Events descriptionText
'''{{ device.displayName }} is On'''.ko={{ device.displayName }}켜졌습니다.
'''{{ device.displayName }} is Off'''.ko={{ device.displayName }}꺼졌습니다.
'''{{ device.displayName }} power is {{ value }} Watts'''.ko={{ device.displayName }} 전은 {{ value }}와트입니다
'''On'''.ko=켜짐
'''{{ device.displayName }} is On'''.ko={{ device.displayName }} 켜짐
'''{{ device.displayName }} is Off'''.ko={{ device.displayName }} 꺼짐
'''{{ device.displayName }} power is {{ value }} Watts'''.ko={{ device.displayName }} 전은 {{ value }}와트입니다.
'''On'''.ko= 켜짐
'''Off'''.ko=꺼짐
'''Turning On'''.ko=켜
'''Turning Off'''.ko=끄
'''Turning On'''.ko=켜는 중
'''Turning Off'''.ko=끄는 중
#==============================================================================

View File

@@ -31,14 +31,14 @@
'''This feature allows you to correct any temperature variations by selecting an offset. Ex: If your sensor consistently reports a temp that's 5 degrees too warm, you'd enter '-5'. If 3 degrees too cold, enter '+3'.'''.ko=기준 온도를 원하는대로 몇 도 올리거나 내려서 설정할 수 있습니다.
'''Degrees'''.ko=온도
'''Adjust temperature by this many degrees'''.ko=몇 도씩 온도를 조절하십시오
'''Give your device a name'''.ko=기기 이름 바꾸기
'''Water Leak Sensor'''.ko=누수센서
'''Give your device a name'''.ko=기기 이름 설정
'''Water Leak Sensor'''.ko=누수감지 센서
'''${currentValue}% battery'''.ko=${currentValue}% 배터리
# Events descriptionText
'''{{ device.displayName }} is dry'''.ko={{ device.displayName }}가 건조
'''{{ device.displayName }} is wet'''.ko={{ device.displayName }}누수
'''{{ device.displayName }} was {{ value }}°C'''.ko={{ device.displayName }}이(가) {{ value }}°C였습니다
'''{{ device.displayName }} was {{ value }}°C'''.ko={{ device.displayName }}에서 {{ value }}°C 감지
'''{{ device.displayName }} was {{ value }}°F'''.ko={{ device.displayName }}이(가) {{ value }}°F였습니다
'''{{ device.displayName }} battery has too much power: (> 3.5) volts.'''.ko={{ device.displayName }} 배터리 전력이 너무 높습니다(3.5볼트 초과).
'''{{ device.displayName }} battery was {{ value }}%'''.ko={{ device.displayName }}남아있는 배터리 {{ value }}%입니다.
'''{{ device.displayName }} battery was {{ value }}%'''.ko={{ device.displayName }}의 남은 배터리 {{ value }}%
#==============================================================================

View File

@@ -28,16 +28,16 @@
'''This feature allows you to correct any temperature variations by selecting an offset. Ex: If your sensor consistently reports a temp that's 5 degrees too warm, you'd enter '-5'. If 3 degrees too cold, enter '+3'.'''.ko=기준 온도를 원하는대로 몇 도 올리거나 내려서 설정할 수 있습니다.
'''Degrees'''.ko=온도
'''Adjust temperature by this many degrees'''.ko=몇 도씩 온도를 조절하십시오
'''Give your device a name'''.ko=기기 이름 바꾸기
'''Give your device a name'''.ko=기기 이름 설정
'''Motion Sensor'''.ko=모션 센서
'''motion'''.ko=동작 감지
'''motion'''.ko= 동작 감지
'''no motion'''.ko=동작 없음
'''${currentValue}% battery'''.ko=${currentValue}% 배터리
# Events descriptionText
'''{{ device.displayName }} detected motion'''.ko={{ device.displayName }} 움직임 감지하였습니다.
'''{{ device.displayName }} motion has stopped'''.ko={{ device.displayName }}움직임이 중단되었습니다
'''{{ device.displayName }} was {{ value }}°C'''.ko={{ device.displayName }}이(가){{ value }}°C였습니다.
'''{{ device.displayName }} detected motion'''.ko={{ device.displayName }}에서 움직임 감지되었습니다.
'''{{ device.displayName }} motion has stopped'''.ko={{ device.displayName }}에서 움직임이 중단되었습니다.
'''{{ device.displayName }} was {{ value }}°C'''.ko={{ device.displayName }}에서 {{ value }}°C 감지
'''{{ device.displayName }} was {{ value }}°F'''.ko={{ device.displayName }}이(가) {{ value }}°F였습니다
'''{{ device.displayName }} battery has too much power: (> 3.5) volts.'''.ko={{ device.displayName }} 배터리 전력이 너무 높습니다(3.5볼트 초과).
'''{{ device.displayName }} battery was {{ value }}%'''.ko={{ device.displayName }}남아있는 배터리 {{ value }}%입니다.
'''{{ device.displayName }} battery was {{ value }}%'''.ko={{ device.displayName }}의 남은 배터리 {{ value }}%
#==============================================================================

View File

@@ -31,20 +31,20 @@
'''Adjust temperature by this many degrees'''.ko=몇 도씩 온도를 조절하십시오
'''Do you want to use this sensor on a garage door?'''.ko=차고 문의 센서 사용 설정하기
'''Tap to set'''.ko=눌러서 설정
'''Give your device a name'''.ko=기기 이름 바꾸기
'''Multipurpose Sensor'''.ko=멀티 센서
'''Give your device a name'''.ko=기기 이름 설정
'''Multipurpose Sensor'''.ko=문 및 창 센서
# Events descriptionText
'''{{ device.displayName }} was opened'''.ko={{ device.displayName }}열림 감지하였습니다.
'''{{ device.displayName }} was closed'''.ko={{ device.displayName }}닫혔습니다.
'''{{ device.displayName }} was active'''.ko={{ device.displayName }}활성화되었습니다.
'''{{ device.displayName }} was inactive'''.ko={{ device.displayName }}비활성화되었습니다.
'''{{ device.displayName }} was {{ value }}°C'''.ko={{ device.displayName }}이(가){{ value }}°C였습니다.
'''{{ device.displayName }} was opened'''.ko={{ device.displayName }}에서 열림 감지되었습니다.
'''{{ device.displayName }} was closed'''.ko={{ device.displayName }}에서 닫힘이 감지되었습니다.
'''{{ device.displayName }} was active'''.ko={{ device.displayName }} 활성화
'''{{ device.displayName }} was inactive'''.ko={{ device.displayName }} 비활성화
'''{{ device.displayName }} was {{ value }}°C'''.ko={{ device.displayName }}에서 {{ value }}°C 감지
'''{{ device.displayName }} was {{ value }}°F'''.ko={{ device.displayName }}이(가) {{ value }}°F였습니다
'''{{ device.displayName }} battery was {{ value }}%'''.ko={{ device.displayName }}남아있는 배터리 {{ value }}%입니다.
'''{{ device.displayName }} battery was {{ value }}%'''.ko={{ device.displayName }}의 남은 배터리 {{ value }}%
'''Updating device to garage sensor'''.ko=기기-차고 센서 업데이트 중
'''Updating device to open/close sensor'''.ko=기기-열림/닫힘 센서 업데이트 중
'''Inactive'''.ko=비활성
'''Active'''.ko=활성
'''Open'''.ko=열림
'''Inactive'''.ko=비활성 상태
'''Active'''.ko=활성 상태
'''Open'''.ko= 열림이 감지될 때
'''Closed'''.ko=닫힘
'''${currentValue}% battery'''.ko=${currentValue}% 배터리

View File

@@ -33,7 +33,7 @@ metadata {
state "power", label: '${currentValue} W'
}
htmlTile(name: "powerContent", attribute: "powerContent", type: "HTML", whitelist: "www.wattvision.com" , url: '${currentValue}', width: 3, height: 2)
htmlTile(name: "powerContent", attribute: "powerContent", type: "HTML", whitelist: ["www.wattvision.com"] , url: '${currentValue}', width: 3, height: 2)
standardTile("refresh", "device.power", inactiveLabel: false, decoration: "flat") {
state "default", label: '', action: "refresh.refresh", icon: "st.secondary.refresh"

View File

@@ -60,7 +60,7 @@ def bridgeDiscovery(params=[:])
app.updateSetting("selectedHue", "")
}
subscribe(location, null, locationHandler, [filterEvents:false])
ssdpSubscribe()
//bridge discovery request every 15 //25 seconds
if((bridgeRefreshCount % 5) == 0) {
@@ -152,6 +152,10 @@ private discoverBridges() {
sendHubCommand(new physicalgraph.device.HubAction("lan discovery urn:schemas-upnp-org:device:basic:1", physicalgraph.device.Protocol.LAN))
}
void ssdpSubscribe() {
subscribe(location, "ssdpTerm.urn:schemas-upnp-org:device:basic:1", ssdpBridgeHandler)
}
private sendDeveloperReq() {
def token = app.id
def host = getBridgeIP()
@@ -161,7 +165,7 @@ private sendDeveloperReq() {
headers: [
HOST: host
],
body: [devicetype: "$token-0"]], "${selectedHue}"))
body: [devicetype: "$token-0"]], "${selectedHue}", [callback: "usernameHandler"]))
}
private discoverHueBulbs() {
@@ -171,7 +175,7 @@ private discoverHueBulbs() {
path: "/api/${state.username}/lights",
headers: [
HOST: host
]], "${selectedHue}"))
]], "${selectedHue}", [callback: "lightsHandler"]))
}
private verifyHueBridge(String deviceNetworkId, String host) {
@@ -181,7 +185,7 @@ private verifyHueBridge(String deviceNetworkId, String host) {
path: "/description.xml",
headers: [
HOST: host
]], deviceNetworkId))
]], deviceNetworkId, [callback: "bridgeDescriptionHandler"]))
}
private verifyHueBridges() {
@@ -293,8 +297,9 @@ def bulbListHandler(hub, data = "") {
}
}
def bridge = null
if (selectedHue)
bridge = getChildDevice(selectedHue)
if (selectedHue) {
bridge = getChildDevice(selectedHue)
}
bridge.sendEvent(name: "bulbList", value: hub, data: bulbs, isStateChange: true, displayed: false)
msg = "${bulbs.size()} bulbs found. ${bulbs}"
return msg
@@ -382,8 +387,9 @@ def addBridge() {
def oldDNI = it.deviceNetworkId
log.debug "updating dni for device ${it} with $newDNI - previous DNI = ${it.deviceNetworkId}"
it.setDeviceNetworkId("${newDNI}")
if (oldDNI == selectedHue)
app.updateSetting("selectedHue", newDNI)
if (oldDNI == selectedHue) {
app.updateSetting("selectedHue", newDNI)
}
newbridge = false
}
}
@@ -412,6 +418,111 @@ def addBridge() {
}
}
def ssdpBridgeHandler(evt) {
def description = evt.description
log.trace "Location: $description"
def hub = evt?.hubId
def parsedEvent = parseLanMessage(description)
parsedEvent << ["hub":hub]
def bridges = getHueBridges()
log.trace bridges.toString()
if (!(bridges."${parsedEvent.ssdpUSN.toString()}")) {
//bridge does not exist
log.trace "Adding bridge ${parsedEvent.ssdpUSN}"
bridges << ["${parsedEvent.ssdpUSN.toString()}":parsedEvent]
} else {
// update the values
def ip = convertHexToIP(parsedEvent.networkAddress)
def port = convertHexToInt(parsedEvent.deviceAddress)
def host = ip + ":" + port
log.debug "Device ($parsedEvent.mac) was already found in state with ip = $host."
def dstate = bridges."${parsedEvent.ssdpUSN.toString()}"
def dni = "${parsedEvent.mac}"
def d = getChildDevice(dni)
def networkAddress = null
if (!d) {
childDevices.each {
if (it.getDeviceDataByName("mac")) {
def newDNI = "${it.getDeviceDataByName("mac")}"
if (newDNI != it.deviceNetworkId) {
def oldDNI = it.deviceNetworkId
log.debug "updating dni for device ${it} with $newDNI - previous DNI = ${it.deviceNetworkId}"
it.setDeviceNetworkId("${newDNI}")
if (oldDNI == selectedHue) {
app.updateSetting("selectedHue", newDNI)
}
doDeviceSync()
}
}
}
} else {
if (d.getDeviceDataByName("networkAddress")) {
networkAddress = d.getDeviceDataByName("networkAddress")
} else {
networkAddress = d.latestState('networkAddress').stringValue
}
log.trace "Host: $host - $networkAddress"
if (host != networkAddress) {
log.debug "Device's port or ip changed for device $d..."
dstate.ip = ip
dstate.port = port
dstate.name = "Philips hue ($ip)"
d.sendEvent(name:"networkAddress", value: host)
d.updateDataValue("networkAddress", host)
}
}
}
}
void bridgeDescriptionHandler(physicalgraph.device.HubResponse hubResponse) {
log.trace "description.xml response (application/xml)"
def body = hubResponse.xml
if (body?.device?.modelName?.text().startsWith("Philips hue bridge")) {
def bridges = getHueBridges()
def bridge = bridges.find {it?.key?.contains(body?.device?.UDN?.text())}
if (bridge) {
bridge.value << [name:body?.device?.friendlyName?.text(), serialNumber:body?.device?.serialNumber?.text(), verified: true]
} else {
log.error "/description.xml returned a bridge that didn't exist"
}
}
}
void lightsHandler(physicalgraph.device.HubResponse hubResponse) {
if (isValidSource(hubResponse.mac)) {
def body = hubResponse.json
if (!body?.state?.on) { //check if first time poll made it here by mistake
def bulbs = getHueBulbs()
log.debug "Adding bulbs to state!"
body.each { k, v ->
bulbs[k] = [id: k, name: v.name, type: v.type, modelid: v.modelid, hub: hubResponse.hubId]
}
}
}
}
void usernameHandler(physicalgraph.device.HubResponse hubResponse) {
if (isValidSource(hubResponse.mac)) {
def body = hubResponse.json
if (body.success != null) {
if (body.success[0] != null) {
if (body.success[0].username)
state.username = body.success[0].username
}
} else if (body.error != null) {
//TODO: handle retries...
log.error "ERROR: application/json ${body.error}"
}
}
}
/**
* @deprecated This has been replaced by the combination of {@link #ssdpBridgeHandler()}, {@link #bridgeDescriptionHandler()},
* {@link #lightsHandler()}, and {@link #usernameHandler()}. After a pending event subscription migration, it can be removed.
*/
@Deprecated
def locationHandler(evt) {
def description = evt.description
log.trace "Location: $description"
@@ -447,17 +558,19 @@ def locationHandler(evt) {
def oldDNI = it.deviceNetworkId
log.debug "updating dni for device ${it} with $newDNI - previous DNI = ${it.deviceNetworkId}"
it.setDeviceNetworkId("${newDNI}")
if (oldDNI == selectedHue)
app.updateSetting("selectedHue", newDNI)
if (oldDNI == selectedHue) {
app.updateSetting("selectedHue", newDNI)
}
doDeviceSync()
}
}
}
} else {
if (d.getDeviceDataByName("networkAddress"))
networkAddress = d.getDeviceDataByName("networkAddress")
else
networkAddress = d.latestState('networkAddress').stringValue
if (d.getDeviceDataByName("networkAddress")) {
networkAddress = d.getDeviceDataByName("networkAddress")
} else {
networkAddress = d.latestState('networkAddress').stringValue
}
log.trace "Host: $host - $networkAddress"
if(host != networkAddress) {
log.debug "Device's port or ip changed for device $d..."
@@ -490,8 +603,9 @@ def locationHandler(evt) {
def body = new groovy.json.JsonSlurper().parseText(parsedEvent.body)
if (body.success != null) {
if (body.success[0] != null) {
if (body.success[0].username)
if (body.success[0].username) {
state.username = body.success[0].username
}
}
} else if (body.error != null) {
//TODO: handle retries...
@@ -516,11 +630,7 @@ def doDeviceSync(){
log.trace "Doing Hue Device Sync!"
convertBulbListToMap()
poll()
try {
subscribe(location, null, locationHandler, [filterEvents:false])
} catch (all) {
log.trace "Subscription already exist"
}
ssdpSubscribe()
discoverBridges()
}
@@ -747,15 +857,11 @@ private getId(childDevice) {
private poll() {
def host = getBridgeIP()
def uri = "/api/${state.username}/lights/"
try {
sendHubCommand(new physicalgraph.device.HubAction("""GET ${uri} HTTP/1.1
log.debug "GET: $host$uri"
sendHubCommand(new physicalgraph.device.HubAction("""GET ${uri} HTTP/1.1
HOST: ${host}
""", physicalgraph.device.Protocol.LAN, selectedHue))
} catch (all) {
log.warn "Parsing Body failed - trying again..."
doDeviceSync()
}
}
private put(path, body) {

View File

@@ -23,9 +23,9 @@
'''Minimum time between messages (optional, defaults to every message)'''.ko=메시지 전송 간격 설정
'''If outside the US please make sure to enter the proper country code'''.ko=미국 이외 국가에 거주한다면 국가 코드와 함께 입력하여 주세요.
'''Water Sensor Wet'''.ko=누수가 감지되었을 때
'''{{ triggerEvent.linkText }} has arrived at the {{ location.name }}'''.ko={{ triggerEvent.linkText }}님이 {{ location.name }}에 도착했습니다
'''{{ triggerEvent.linkText }} has arrived at {{ location.name }}'''.ko={{ triggerEvent.linkText }}님이 {{ location.name }}에 도착했습니다
'''{{ triggerEvent.linkText }} has left the {{ location.name }}'''.ko={{ triggerEvent.linkText }}님이 {{ location.name }}을(를) 떠났습니다
'''{{ triggerEvent.linkText }} has left {{ location.name }}'''.ko={{ triggerEvent.linkText }}님이 {{ location.name }}을(를) 떠났습니다
'''{{ triggerEvent.linkText }} has arrived at the {{ location.name }}'''.ko={{ location.name }}에 {{ triggerEvent.linkText }} 귀가
'''{{ triggerEvent.linkText }} has arrived at {{ location.name }}'''.ko={{ location.name }}에 {{ triggerEvent.linkText }} 귀가
'''{{ triggerEvent.linkText }} has left the {{ location.name }}'''.ko={{ location.name }}에서 {{ triggerEvent.linkText }} 외출
'''{{ triggerEvent.linkText }} has left {{ location.name }}'''.ko={{ location.name }}에서 {{ triggerEvent.linkText }} 외출
'''Assign a name'''.ko=이름 설정