* Fibaro Swipe ZW5
|
||||
*
|
||||
* Copyright 2016 Fibar Group S.A.
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
|
||||
* in compliance with the License. You may obtain a copy of the License at:
|
||||
*
|
||||
* http://www.apache.org/licenses/LICENSE-2.0
|
||||
*
|
||||
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
|
||||
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
*/
|
||||
metadata {
|
||||
definition (name: "Fibaro Swipe ZW5", namespace: "fibargroup", author: "Fibar Group S.A.") {
|
||||
capability "Actuator"
|
||||
capability "Battery"
|
||||
capability "Button"
|
||||
capability "Configuration"
|
||||
capability "Sensor"
|
||||
|
||||
fingerprint deviceId: "0x1801", inClusters: "0x5E, 0x85, 0x59, 0x80, 0x5B, 0x70, 0x56, 0x5A, 0x7A, 0x72, 0x8E, 0x73, 0x98, 0x86, 0x84", outClusters: ""
|
||||
}
|
||||
|
||||
simulator {
|
||||
// TODO: define status and reply messages here
|
||||
}
|
||||
|
||||
tiles {
|
||||
standardTile("button", "device.button", width: 2, height: 2) {
|
||||
state "default", label: "", icon: "st.unknown.zwave.remote-controller", backgroundColor: "#ffffff"
|
||||
}
|
||||
valueTile("battery", "device.battery", inactiveLabel: false, decoration: "flat", width: 1, height: 1) {
|
||||
state "battery", label:'${currentValue}% battery', unit:"%"
|
||||
}
|
||||
main "button"
|
||||
details(["button", "battery"])
|
||||
}
|
||||
}
|
||||
|
||||
// parse events into attributes
|
||||
def parse(String description) {
|
||||
log.debug "Parsing '${description}'"
|
||||
|
||||
if (description.startsWith("Err 106")) {
|
||||
if (state.sec) {
|
||||
result = createEvent(descriptionText:description, displayed:false)
|
||||
} else {
|
||||
result = createEvent(
|
||||
descriptionText: "FGGC failed to complete the network security key exchange. If you are unable to receive data from it, you must remove it from your network and add it again.",
|
||||
eventType: "ALERT",
|
||||
name: "secureInclusion",
|
||||
value: "failed",
|
||||
displayed: true,
|
||||
)
|
||||
}
|
||||
} else if (description == "updated") {
|
||||
return null
|
||||
} else {
|
||||
def cmd = zwave.parse(description, [0x5A: 1, 0x5B: 1, 0x72: 2, 0x80: 1, 0x84: 2, 0x86: 1])
|
||||
|
||||
if (cmd) {
|
||||
log.debug "Parsed '${cmd}'"
|
||||
zwaveEvent(cmd)
|
||||
}
|
||||
}
|
||||
|
||||
}
|
||||
|
||||
//security
|
||||
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
|
||||
def encapsulatedCommand = cmd.encapsulatedCommand([0x5A: 1, 0x5B: 1, 0x84: 2])
|
||||
if (encapsulatedCommand) {
|
||||
return zwaveEvent(encapsulatedCommand)
|
||||
} else {
|
||||
log.warn "Unable to extract encapsulated cmd from $cmd"
|
||||
createEvent(descriptionText: cmd.toString())
|
||||
}
|
||||
}
|
||||
|
||||
//crc16
|
||||
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd)
|
||||
{
|
||||
def versions = [0x72: 2, 0x80: 1, 0x86: 1]
|
||||
def version = versions[cmd.commandClass as Integer]
|
||||
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
|
||||
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
|
||||
if (!encapsulatedCommand) {
|
||||
log.debug "Could not extract command from $cmd"
|
||||
} else {
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.centralscenev1.CentralSceneNotification cmd) {
|
||||
if (!state.seqNumber || state.seqNumber != cmd.sequenceNumber) {
|
||||
def sceneNumberMapping = [1: "Up", 2: "Down", 3: "Left", 4: "Right"]
|
||||
def keyAttributesMapping = [0: "single", 3: "double"]
|
||||
|
||||
log.debug "Central Scene Notification received: sequenceNumber: ${cmd.sequenceNumber}, sceneNumber: ${cmd.sceneNumber}, keyAttributes: ${cmd.keyAttributes}"
|
||||
|
||||
state.seqNumber = cmd.sequenceNumber
|
||||
|
||||
return gestureEvent(sceneNumberMapping.get(cmd.sceneNumber.intValue()), keyAttributesMapping.get(cmd.keyAttributes.intValue()))
|
||||
} else {
|
||||
log.debug "Same Central Scene Notification received multiple times: sequenceNumber: ${cmd.sequenceNumber}, sceneNumber: ${cmd.sceneNumber}, keyAttributes: ${cmd.keyAttributes}"
|
||||
}
|
||||
|
||||
state.seqNumber = cmd.sequenceNumber
|
||||
}
|
||||
|
||||
def gestureEvent(gesture, keyAttribute) {
|
||||
return createEvent(name: "button", value: "${gesture}", data: [flicks: "${keyAttribute}"], descriptionText: "${device.displayName} gesture ${gesture}(${keyAttribute})", isStateChange: true)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerSpecificReport cmd) {
|
||||
log.debug "manufacturerId: ${cmd.manufacturerId}"
|
||||
log.debug "manufacturerName: ${cmd.manufacturerName}"
|
||||
log.debug "productId: ${cmd.productId}"
|
||||
log.debug "productTypeId: ${cmd.productTypeId}"
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.DeviceSpecificReport cmd) {
|
||||
log.debug "deviceIdData: ${cmd.deviceIdData}"
|
||||
log.debug "deviceIdDataFormat: ${cmd.deviceIdDataFormat}"
|
||||
log.debug "deviceIdDataLengthIndicator: ${cmd.deviceIdDataLengthIndicator}"
|
||||
log.debug "deviceIdType: ${cmd.deviceIdType}"
|
||||
|
||||
if (cmd.deviceIdType == 1 && cmd.deviceIdDataFormat == 1) {//serial number in binary format
|
||||
String serialNumber = "h'"
|
||||
|
||||
cmd.deviceIdData.each{ data ->
|
||||
serialNumber += "${String.format("%02X", data)}"
|
||||
}
|
||||
|
||||
updateDataValue("serialNumber", serialNumber)
|
||||
log.debug "${device.displayName} - serial number: ${serialNumber}"
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.versionv1.VersionReport cmd) {
|
||||
updateDataValue("version", "${cmd.applicationVersion}.${cmd.applicationSubVersion}")
|
||||
log.debug "applicationVersion: ${cmd.applicationVersion}"
|
||||
log.debug "applicationSubVersion: ${cmd.applicationSubVersion}"
|
||||
log.debug "zWaveLibraryType: ${cmd.zWaveLibraryType}"
|
||||
log.debug "zWaveProtocolVersion: ${cmd.zWaveProtocolVersion}"
|
||||
log.debug "zWaveProtocolSubVersion: ${cmd.zWaveProtocolSubVersion}"
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.wakeupv2.WakeUpNotification cmd)
|
||||
{
|
||||
def event = createEvent(descriptionText: "${device.displayName} woke up", displayed: false)
|
||||
def cmds = []
|
||||
if (!state.lastbatt || (new Date().time) - state.lastbatt > 24*60*60*1000) {
|
||||
log.debug("Device has been configured sending >> batteryGet()")
|
||||
cmds << encap(zwave.batteryV1.batteryGet())
|
||||
cmds << "delay 1200"
|
||||
}
|
||||
|
||||
cmds << encap(zwave.wakeUpV1.wakeUpNoMoreInformation())
|
||||
[event, response(cmds)]
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
|
||||
def map = [:]
|
||||
map.name = "battery"
|
||||
map.value = cmd.batteryLevel == 255 ? 1 : cmd.batteryLevel.toString()
|
||||
map.unit = "%"
|
||||
map.displayed = true
|
||||
//Store time of last battery update so we don't ask every wakeup, see WakeUpNotification handler
|
||||
state.lastbatt = now()
|
||||
createEvent(map)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.deviceresetlocallyv1.DeviceResetLocallyNotification cmd) {
|
||||
log.info "${device.displayName}: received command: $cmd - device has reset itself"
|
||||
}
|
||||
|
||||
// handle commands
|
||||
def configure() {
|
||||
log.debug "Executing 'configure'"
|
||||
|
||||
def cmds = []
|
||||
|
||||
cmds += zwave.manufacturerSpecificV1.manufacturerSpecificGet()
|
||||
cmds += zwave.manufacturerSpecificV2.deviceSpecificGet()
|
||||
cmds += zwave.versionV1.versionGet()
|
||||
//set parameter 12 to 0 to enable double flicks for gestures 1-4
|
||||
cmds += zwave.configurationV1.configurationSet(parameterNumber: 12, size: 1, scaledConfigurationValue: 0)
|
||||
cmds += zwave.wakeUpV2.wakeUpIntervalSet(seconds:21600, nodeid:zwaveHubNodeId)//FGGC's default wake up interval
|
||||
cmds += zwave.batteryV1.batteryGet()
|
||||
cmds += zwave.associationV2.associationSet(groupingIdentifier:1, nodeId:[zwaveHubNodeId])
|
||||
|
||||
cmds += zwave.wakeUpV2.wakeUpNoMoreInformation()
|
||||
|
||||
encapSequence(cmds, 500)
|
||||
}
|
||||
|
||||
private secure(physicalgraph.zwave.Command cmd) {
|
||||
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
|
||||
}
|
||||
|
||||
private crc16(physicalgraph.zwave.Command cmd) {
|
||||
//zwave.crc16encapV1.crc16Encap().encapsulate(cmd).format()
|
||||
"5601${cmd.format()}0000"
|
||||
}
|
||||
|
||||
private encapSequence(commands, delay=200) {
|
||||
delayBetween(commands.collect{ encap(it) }, delay)
|
||||
}
|
||||
|
||||
private encap(physicalgraph.zwave.Command cmd) {
|
||||
def secureClasses = [0x5A, 0x5B, 0x70, 0x84, 0x85, 0x8E]
|
||||
|
||||
//todo: check if secure inclusion was successful
|
||||
//if not do not send security-encapsulated command
|
||||
if (secureClasses.find{ it == cmd.commandClassId }) {
|
||||
secure(cmd)
|
||||
} else {
|
||||
crc16(cmd)
|
||||
}
|
||||
}
|
||||
@@ -14,6 +14,7 @@
|
||||
*
|
||||
*/
|
||||
|
||||
//@Deprecated: Moved to ZLL Dimmer Bulb
|
||||
metadata {
|
||||
definition (name: "Cree Bulb", namespace: "smartthings", author: "SmartThings") {
|
||||
|
||||
@@ -24,7 +25,7 @@ metadata {
|
||||
capability "Switch"
|
||||
capability "Switch Level"
|
||||
|
||||
fingerprint profileId: "C05E", inClusters: "0000,0003,0004,0005,0006,0008,1000", outClusters: "0000,0019"
|
||||
//fingerprint profileId: "C05E", inClusters: "0000,0003,0004,0005,0006,0008,1000", outClusters: "0000,0019"
|
||||
}
|
||||
|
||||
// simulator metadata
|
||||
|
||||
@@ -138,7 +138,6 @@ def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerS
|
||||
log.debug "productTypeId: ${cmd.productTypeId}"
|
||||
def msr = String.format("%04X-%04X-%04X", cmd.manufacturerId, cmd.productTypeId, cmd.productId)
|
||||
updateDataValue("MSR", msr)
|
||||
updateDataValue("manufacturer", cmd.manufacturerName)
|
||||
createEvent([descriptionText: "$device.displayName MSR: $msr", isStateChange: false])
|
||||
}
|
||||
|
||||
|
||||
@@ -129,7 +129,6 @@ def refresh() {
|
||||
}
|
||||
|
||||
def configure() {
|
||||
sendEvent(name: "checkInterval", value: 1200, displayed: false)
|
||||
zigbee.onOffConfig() + powerConfig() + refresh()
|
||||
}
|
||||
|
||||
|
||||
@@ -311,8 +311,6 @@ def refresh() {
|
||||
}
|
||||
|
||||
def configure() {
|
||||
sendEvent(name: "checkInterval", value: 7200, displayed: false)
|
||||
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting, IAS CIE, and Bindings."
|
||||
def configCmds = [
|
||||
|
||||
@@ -323,8 +323,6 @@ def refresh() {
|
||||
}
|
||||
|
||||
def configure() {
|
||||
sendEvent(name: "checkInterval", value: 7200, displayed: false)
|
||||
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting, IAS CIE, and Bindings."
|
||||
|
||||
|
||||
@@ -441,8 +441,6 @@ def refresh() {
|
||||
}
|
||||
|
||||
def configure() {
|
||||
sendEvent(name: "checkInterval", value: 7200, displayed: false)
|
||||
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting"
|
||||
|
||||
|
||||
@@ -300,7 +300,6 @@ def getTemperature(value) {
|
||||
}
|
||||
|
||||
def configure() {
|
||||
sendEvent(name: "checkInterval", value: 7200, displayed: false)
|
||||
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting, IAS CIE, and Bindings."
|
||||
|
||||
@@ -252,7 +252,6 @@ def refresh()
|
||||
}
|
||||
|
||||
def configure() {
|
||||
sendEvent(name: "checkInterval", value: 7200, displayed: false)
|
||||
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
def configCmds = [
|
||||
|
||||
@@ -110,7 +110,7 @@ def installed() {
|
||||
sendEvent(name: "multilineText", value: "Line 1 YES\nLine 2 YES\nLine 3 NO")
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def parse() {
|
||||
// This is a simulated device. No incoming data to parse.
|
||||
}
|
||||
|
||||
|
||||
@@ -22,9 +22,8 @@ metadata {
|
||||
capability "Switch"
|
||||
capability "Switch Level"
|
||||
|
||||
//fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0000,0019"
|
||||
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0019"
|
||||
//fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0000,0019", manufacturer: "CREE", model: "Connected A-19 60W Equivalent", deviceJoinName: "Cree Connected Bulb"
|
||||
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0000,0019"
|
||||
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0000,0019", manufacturer: "CREE", model: "Connected A-19 60W Equivalent", deviceJoinName: "Cree Connected Bulb"
|
||||
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "Classic A60 W clear", deviceJoinName: "OSRAM LIGHTIFY LED Smart Connected Light"
|
||||
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000, 0B04, FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "Classic A60 W clear - LIGHTIFY", deviceJoinName: "OSRAM LIGHTIFY LED Smart Connected Light"
|
||||
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0019", manufacturer: "Philips", model: "LWB006", deviceJoinName: "Philips Hue White"
|
||||
|
||||
@@ -95,17 +95,11 @@ def zwaveEvent(physicalgraph.zwave.commands.hailv1.Hail cmd) {
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerSpecificReport cmd) {
|
||||
log.debug "manufacturerId: ${cmd.manufacturerId}"
|
||||
log.debug "manufacturerName: ${cmd.manufacturerName}"
|
||||
log.debug "productId: ${cmd.productId}"
|
||||
log.debug "productTypeId: ${cmd.productTypeId}"
|
||||
def msr = String.format("%04X-%04X-%04X", cmd.manufacturerId, cmd.productTypeId, cmd.productId)
|
||||
updateDataValue("MSR", msr)
|
||||
updateDataValue("manufacturer", cmd.manufacturerName)
|
||||
createEvent([descriptionText: "$device.displayName MSR: $msr", isStateChange: false])
|
||||
if (state.manufacturer != cmd.manufacturerName) {
|
||||
updateDataValue("manufacturer", cmd.manufacturerName)
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
// Handles all Z-Wave commands we aren't interested in
|
||||
[:]
|
||||
|
||||
@@ -273,7 +273,7 @@ def scheduleCheck(evt) {
|
||||
else {
|
||||
if(people){
|
||||
//don't turn off lights if anyone is home
|
||||
if(someoneIsHome){
|
||||
if(someoneIsHome()){
|
||||
log.debug("Stopping Check for Light")
|
||||