Compare commits

..

12 Commits

Author SHA1 Message Date
Andres
c10d33c6d8 MSA-1793: Hi,
We update the zwave version with our fingerprint data and we add the tamper alert.
Regards,
Andres V.
2017-02-17 21:41:56 -08:00
Jack Chi
51832c8db2 Merge pull request #1671 from skt123/zwave_device_filtering
[DVCSMP-2433] Device Filtering change for Z-wave devices
2017-02-14 15:14:07 -08:00
Jack Chi
f001eb0792 Merge pull request #1672 from pchomal/devicefiltering1
[DVCSMP-2431] DTH Device Filtering change for ZigBee Devices
2017-02-14 15:13:26 -08:00
piyush.c
7c5734b752 [DVCSMP-2431] DTH Device Filtering change for ZigBee Devices 2017-02-14 15:26:50 +05:30
Jack Chi
2a3c393534 Merge pull request #1670 from pchomal/devicefiltering1
[DVCSMP-2436] DTH Device Filtering change for Lifx Bulbs
2017-02-14 01:53:48 -08:00
Jack Chi
91763e7b4d Merge pull request #1591 from parijatdas/leviton_receptacle
[CHF-504] [CHF-505] Implementation of HealthCheck for Leviton 5A Incandescent Switch (VRS05-1LZ) and Leviton 15A Split Duplex Receptacle (VRR15-1LZ)
2017-02-14 01:52:34 -08:00
sushant.k1
1263b72a72 [DVCSMP-2433]
Adding "Light" capability to the following Z-wave DTHs:
1. Z-Wave Metering Dimmer
2. Z-Wave Metering Switch
3. Z-Wave Dimmer Switch Generic
4. Z-Wave Switch
5. Z-Wave Switch Generic
6. MimoLite Garage Door Controller
2017-02-14 15:13:28 +05:30
piyush.c
bf45430061 [DVCSMP-2436] DTH Device Filtering change for Lifx Bulbs 2017-02-14 15:01:17 +05:30
Jack Chi
054ccbeffe Merge pull request #1590 from pchomal/dimmerswitch_generic
[CHF-477] Health Check implementation for Z-Wave Dimmer Switch Generic
2017-02-13 14:22:54 -08:00
piyush.c
6e28d83e96 [CHF-477]
Health Check implementation for Z-Wave Dimmer Switch Generic
2017-02-13 12:36:32 +05:30
Vinay Rao
2d82b05f90 Merge pull request #1660 from SmartThingsCommunity/staging
Rolling down staging hotfixes to master
2017-02-09 17:54:06 -06:00
Parijat Das
61356ec8a7 Added fingerprints for the following devices:
1. Leviton 5A Incandescent Switch (VRS05-1LZ)
2. Leviton 15A Split Duplex Receptacle (VRR15-1LZ)
2017-01-17 19:17:41 +05:30
13 changed files with 283 additions and 1 deletions

View File

@@ -0,0 +1,256 @@
/**
* Besense z-wave Door/window sensor
*/
metadata {
definition (name: "BeSense Door/Window Sensor", namespace: "BeSense", author: "BeSense") {
capability "Contact Sensor"
capability "Sensor"
capability "Battery"
capability "Configuration"
fingerprint mfr: "0214", prod: "0002", model: "0001", deviceJoinName: "BeSense Door/window sensor"
}
// simulator metadata
simulator {
// status messages
status "open": "command: 2001, payload: FF"
status "closed": "command: 2001, payload: 00"
status "wake up": "command: 8407, payload: "
}
// UI tile definitions
tiles(scale: 1) {
standardTile("contact", "device.contact", width: 3, height: 3, canChangeIcon: true) {
state ("open", label: '${name}', icon: "st.contact.contact.open", backgroundColor: "#ea0f46")
state ("closed", label: '${name}', icon: "st.contact.contact.closed", backgroundColor: "#27CC73")
}
valueTile("battery", "device.battery", inactiveLabel: false, decoration: "flat") {
state "battery", label:'${currentValue}% battery', unit:""
}
main "contact"
details(["contact", "battery"])
}
}
def parse(String description) {
def result = null
if (description.startsWith("Err 106")) {
if (state.sec) {
log.debug description
} else {
result = createEvent(
descriptionText: "This sensor failed to complete the network security key exchange. If you are unable to control it via SmartThings, you must remove it from your network and add it again.",
eventType: "ALERT",
name: "secureInclusion",
value: "failed",
isStateChange: true,
)
}
} else if (description != "updated") {
def cmd = zwave.parse(description, [0x20: 1, 0x25: 1, 0x30: 1, 0x31: 5, 0x80: 1, 0x84: 1, 0x71: 3, 0x9C: 1])
if (cmd) {
result = zwaveEvent(cmd)
}
}
log.debug "parsed '$description' to $result"
return result
}
def updated() {
def cmds = []
if (!state.MSR) {
cmds = [
command(zwave.manufacturerSpecificV2.manufacturerSpecificGet()),
"delay 1200",
zwave.wakeUpV1.wakeUpNoMoreInformation().format()
]
} else if (!state.lastbat) {
cmds = []
} else {
cmds = [zwave.wakeUpV1.wakeUpNoMoreInformation().format()]
}
response(cmds)
}
def configure() {
commands([
zwave.manufacturerSpecificV2.manufacturerSpecificGet(),
zwave.batteryV1.batteryGet()
], 6000)
}
def sensorValueEvent(value) {
if (value) {
createEvent(name: "contact", value: "open", descriptionText: "$device.displayName is open")
} else {
createEvent(name: "contact", value: "closed", descriptionText: "$device.displayName is closed")
}
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd)
{
sensorValueEvent(cmd.value)
}
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd)
{
sensorValueEvent(cmd.value)
}
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd)
{
sensorValueEvent(cmd.value)
}
def zwaveEvent(physicalgraph.zwave.commands.sensorbinaryv1.SensorBinaryReport cmd)
{
sensorValueEvent(cmd.sensorValue)
}
def zwaveEvent(physicalgraph.zwave.commands.sensoralarmv1.SensorAlarmReport cmd)
{
sensorValueEvent(cmd.sensorState)
}
def zwaveEvent(physicalgraph.zwave.commands.notificationv3.NotificationReport cmd)
{
def result = []
if (cmd.notificationType == 0x06 && cmd.event == 0x16) {
result << sensorValueEvent(1)
} else if (cmd.notificationType == 0x06 && cmd.event == 0x17) {
result << sensorValueEvent(0)
} else if (cmd.notificationType == 0x07) {
if (cmd.v1AlarmType == 0x07) { // special case for nonstandard messages from Monoprice door/window sensors
result << sensorValueEvent(cmd.v1AlarmLevel)
} else if (cmd.event == 0x01 || cmd.event == 0x02) {
result << sensorValueEvent(1)
} else if (cmd.event == 0x03) {
result << createEvent(descriptionText: "$device.displayName covering was removed", isStateChange: true)
if(!state.MSR) result << response(command(zwave.manufacturerSpecificV2.manufacturerSpecificGet()))
} else if (cmd.event == 0x05 || cmd.event == 0x06) {
result << createEvent(descriptionText: "$device.displayName detected glass breakage", isStateChange: true)
} else if (cmd.event == 0x07) {
if(!state.MSR) result << response(command(zwave.manufacturerSpecificV2.manufacturerSpecificGet()))
result << createEvent(name: "motion", value: "active", descriptionText:"$device.displayName detected motion")
}
} else if (cmd.notificationType) {
def text = "Notification $cmd.notificationType: event ${([cmd.event] + cmd.eventParameter).join(", ")}"
result << createEvent(name: "notification$cmd.notificationType", value: "$cmd.event", descriptionText: text, displayed: false)
} else {
def value = cmd.v1AlarmLevel == 255 ? "active" : cmd.v1AlarmLevel ?: "inactive"
result << createEvent(name: "alarm $cmd.v1AlarmType", value: value, displayed: false)
}
result
}
def zwaveEvent(physicalgraph.zwave.commands.wakeupv1.WakeUpNotification cmd)
{
def event = createEvent(descriptionText: "${device.displayName} woke up", isStateChange: false)
def cmds = []
if (!state.MSR) {
cmds << command(zwave.manufacturerSpecificV2.manufacturerSpecificGet())
cmds << "delay 1200"
}
if (!state.lastbat || now() - state.lastbat > 53*60*60*1000) {
cmds << command(zwave.batteryV1.batteryGet())
} else {
cmds << zwave.wakeUpV1.wakeUpNoMoreInformation().format()
}
[event, response(cmds)]
}
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def map = [ name: "battery", unit: "%" ]
if (cmd.batteryLevel == 0xFF) {
map.value = 1
map.descriptionText = "${device.displayName} has a low battery"
map.isStateChange = true
} else {
map.value = cmd.batteryLevel
}
state.lastbat = now()
[createEvent(map), response(zwave.wakeUpV1.wakeUpNoMoreInformation())]
}
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerSpecificReport cmd) {
def result = []
def msr = String.format("%04X-%04X-%04X", cmd.manufacturerId, cmd.productTypeId, cmd.productId)
log.debug "msr: $msr"
updateDataValue("MSR", msr)
retypeBasedOnMSR()
result << createEvent(descriptionText: "$device.displayName MSR: $msr", isStateChange: false)
if (msr == "011A-0601-0901") { // Enerwave motion doesn't always get the associationSet that the hub sends on join
result << response(zwave.associationV1.associationSet(groupingIdentifier:1, nodeId:zwaveHubNodeId))
} else if (!device.currentState("battery")) {
if (msr == "0086-0102-0059") {
result << response(zwave.securityV1.securityMessageEncapsulation().encapsulate(zwave.batteryV1.batteryGet()).format())
} else {
result << response(command(zwave.batteryV1.batteryGet()))
}
}
result
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
def encapsulatedCommand = cmd.encapsulatedCommand([0x20: 1, 0x25: 1, 0x30: 1, 0x31: 5, 0x80: 1, 0x84: 1, 0x71: 3, 0x9C: 1])
// log.debug "encapsulated: $encapsulatedCommand"
if (encapsulatedCommand) {
state.sec = 1
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
createEvent(descriptionText: "$device.displayName: $cmd", displayed: false)
}
private command(physicalgraph.zwave.Command cmd) {
if (state.sec == 1) {
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
} else {
cmd.format()
}
}
private commands(commands, delay=200) {
delayBetween(commands.collect{ command(it) }, delay)
}
def retypeBasedOnMSR() {
switch (state.MSR) {
case "0086-0002-002D":
log.debug "Changing device type to Z-Wave Water Sensor"
setDeviceType("Z-Wave Water Sensor")
break
case "011F-0001-0001": // Schlage motion
case "014A-0001-0001": // Ecolink motion
case "014A-0004-0001": // Ecolink motion +
case "0060-0001-0002": // Everspring SP814
case "0060-0001-0003": // Everspring HSP02
case "011A-0601-0901": // Enerwave ZWN-BPC
case "0214-0002-0002": // Besense pir or ceiling sensor
log.debug "Changing device type to Z-Wave Motion Sensor"
setDeviceType("Z-Wave Motion Sensor")
break
case "013C-0002-000D": // Philio multi +
log.debug "Changing device type to 3-in-1 Multisensor Plus (SG)"
setDeviceType("3-in-1 Multisensor Plus (SG)")
break
case "0109-2001-0106": // Vision door/window
log.debug "Changing device type to Z-Wave Plus Door/Window Sensor"
setDeviceType("Z-Wave Plus Door/Window Sensor")
break
case "0109-2002-0205": // Vision Motion
log.debug "Changing device type to Z-Wave Plus Motion/Temp Sensor"
setDeviceType("Z-Wave Plus Motion/Temp Sensor")
break
}
}

View File

@@ -14,6 +14,7 @@ metadata {
capability "Refresh"
capability "Sensor"
capability "Health Check"
capability "Light"
}
simulator {

View File

@@ -13,6 +13,7 @@ metadata {
capability "Refresh"
capability "Sensor"
capability "Health Check"
capability "Light"
}
simulator {

View File

@@ -36,6 +36,7 @@ metadata {
capability "Switch"
capability "Refresh"
capability "Contact Sensor"
capability "Light"
attribute "powered", "string"

View File

@@ -23,6 +23,7 @@ Works with:
* **Switch** - can detect state (possible values: on/off)
* **Switch Level** - represents current light level, usually 0-100 in percent
* **Health Check** - indicates ability to get device health notifications
* **Light** - indicates that the device belongs to Light category.
## Device Health

View File

@@ -22,6 +22,7 @@ metadata {
capability "Switch"
capability "Switch Level"
capability "Health Check"
capability "Light"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B04"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702"

View File

@@ -21,6 +21,7 @@ metadata {
capability "Sensor"
capability "Switch"
capability "Health Check"
capability "Light"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0B04"
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0702"

View File

@@ -6,6 +6,12 @@ Works with:
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW)](https://www.smartthings.com/works-with-smartthings/outlets/leviton-plug-in-lamp-dimmer-module)
* [Leviton Universal Dimmer (DZMX1-LZ)](https://www.smartthings.com/works-with-smartthings/switches-and-dimmers/leviton-universal-dimmer)
* [Leviton 1000W Incandescent Dimmer](https://www.smartthings.com/works-with-smartthings/leviton/leviton-1000w-incandescent-dimmer)
* [Leviton 600W Incandescent Dimmer](https://www.smartthings.com/works-with-smartthings/leviton/leviton-600w-incandescent-dimmer)
* [Enerwave In-Wall Dimmer](https://www.smartthings.com/works-with-smartthings/enerwave/enerwave-in-wall-dimmer-zw500d)
* [Leviton 3-Speed Fan Controller](https://www.smartthings.com/works-with-smartthings/leviton/leviton-3-speed-fan-controller)
* [Leviton Magnetic Low Voltage Dimmer](https://www.smartthings.com/works-with-smartthings/leviton/leviton-magnetic-low-voltage-dimmer)
* [Remotec Technology Plug-In Dimmer](https://www.smartthings.com/works-with-smartthings/remotec-technology/remotec-technology-plug-in-dimmer)
## Table of contents
@@ -40,4 +46,9 @@ If the device doesn't pair when trying from the SmartThings mobile app, it is po
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton Universal Dimmer (DZMX1-LZ) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton Universal Dimmer (DZMX1-LZ) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton 1000W Incandescent Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton 600W Incandescent Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Leviton 3-Speed Fan Controller Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
* [Enerwave In-Wall Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/204854176-How-to-connect-Enerwave-switches-and-dimmers)
* [Remotec Technology Plug-In Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202295150-Remotec-Technology-Plug-In-Dimmer-ZDS-100-)

View File

@@ -20,6 +20,7 @@ metadata {
capability "Polling"
capability "Refresh"
capability "Sensor"
capability "Light"
fingerprint inClusters: "0x26", deviceJoinName: "Z-Wave Dimmer"
fingerprint mfr:"001D", prod:"1902", deviceJoinName: "Z-Wave Dimmer"
@@ -28,6 +29,8 @@ metadata {
fingerprint mfr:"001D", prod:"1001", model:"0334", deviceJoinName: "Leviton 3-Speed Fan Controller"
fingerprint mfr:"001D", prod:"0602", model:"0334", deviceJoinName: "Leviton Magnetic Low Voltage Dimmer"
fingerprint mfr:"001D", prod:"0401", model:"0334", deviceJoinName: "Leviton 600W Incandescent Dimmer"
fingerprint mfr:"0111", prod:"8200", model:"0200", deviceJoinName: "Remotec Technology Plug-In Dimmer"
fingerprint mfr:"1104", prod:"001D", model:"0501", deviceJoinName: "Leviton 1000W Incandescant Dimmer"
}
simulator {

View File

@@ -25,6 +25,7 @@ metadata {
capability "Switch Level"
capability "Sensor"
capability "Actuator"
capability "Light"
command "reset"

View File

@@ -21,6 +21,7 @@ metadata {
capability "Refresh"
capability "Configuration"
capability "Sensor"
capability "Light"
command "reset"

View File

@@ -19,6 +19,7 @@ metadata {
capability "Polling"
capability "Refresh"
capability "Sensor"
capability "Light"
fingerprint inClusters: "0x25", deviceJoinName: "Z-Wave Switch"
fingerprint mfr:"001D", prod:"1A02", model:"0334", deviceJoinName: "Leviton Appliance Module"
@@ -26,6 +27,8 @@ metadata {
fingerprint mfr:"001D", prod:"1D04", model:"0334", deviceJoinName: "Leviton Outlet"
fingerprint mfr:"001D", prod:"1C02", model:"0334", deviceJoinName: "Leviton Switch"
fingerprint mfr:"001D", prod:"0301", model:"0334", deviceJoinName: "Leviton 15A Switch"
fingerprint mfr:"001D", prod:"0F01", model:"0334", deviceJoinName: "Leviton 5A Incandescent Switch"
fingerprint mfr:"001D", prod:"1603", model:"0334", deviceJoinName: "Leviton 15A Split Duplex Receptacle"
fingerprint mfr:"011A", prod:"0101", model:"0102", deviceJoinName: "Enerwave On/Off Switch"
fingerprint mfr:"011A", prod:"0101", model:"0603", deviceJoinName: "Enerwave Duplex Receptacle"
}

View File

@@ -20,6 +20,7 @@ metadata {
capability "Refresh"
capability "Sensor"
capability "Health Check"
capability "Light"
fingerprint mfr:"0063", prod:"4952", deviceJoinName: "Z-Wave Wall Switch"
fingerprint mfr:"0063", prod:"5257", deviceJoinName: "Z-Wave Wall Switch"