mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-09 21:03:00 +00:00
Compare commits
12 Commits
PROD_2017.
...
MSA-1793-3
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
c10d33c6d8 | ||
|
|
51832c8db2 | ||
|
|
f001eb0792 | ||
|
|
7c5734b752 | ||
|
|
2a3c393534 | ||
|
|
91763e7b4d | ||
|
|
1263b72a72 | ||
|
|
bf45430061 | ||
|
|
054ccbeffe | ||
|
|
6e28d83e96 | ||
|
|
2d82b05f90 | ||
|
|
61356ec8a7 |
@@ -0,0 +1,256 @@
|
||||
/**
|
||||
* Besense z-wave Door/window sensor
|
||||
*/
|
||||
|
||||
metadata {
|
||||
definition (name: "BeSense Door/Window Sensor", namespace: "BeSense", author: "BeSense") {
|
||||
capability "Contact Sensor"
|
||||
capability "Sensor"
|
||||
capability "Battery"
|
||||
capability "Configuration"
|
||||
|
||||
fingerprint mfr: "0214", prod: "0002", model: "0001", deviceJoinName: "BeSense Door/window sensor"
|
||||
}
|
||||
|
||||
// simulator metadata
|
||||
simulator {
|
||||
// status messages
|
||||
status "open": "command: 2001, payload: FF"
|
||||
status "closed": "command: 2001, payload: 00"
|
||||
status "wake up": "command: 8407, payload: "
|
||||
}
|
||||
|
||||
// UI tile definitions
|
||||
tiles(scale: 1) {
|
||||
standardTile("contact", "device.contact", width: 3, height: 3, canChangeIcon: true) {
|
||||
state ("open", label: '${name}', icon: "st.contact.contact.open", backgroundColor: "#ea0f46")
|
||||
state ("closed", label: '${name}', icon: "st.contact.contact.closed", backgroundColor: "#27CC73")
|
||||
}
|
||||
valueTile("battery", "device.battery", inactiveLabel: false, decoration: "flat") {
|
||||
state "battery", label:'${currentValue}% battery', unit:""
|
||||
}
|
||||
|
||||
main "contact"
|
||||
details(["contact", "battery"])
|
||||
}
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def result = null
|
||||
if (description.startsWith("Err 106")) {
|
||||
if (state.sec) {
|
||||
log.debug description
|
||||
} else {
|
||||
result = createEvent(
|
||||
descriptionText: "This sensor failed to complete the network security key exchange. If you are unable to control it via SmartThings, you must remove it from your network and add it again.",
|
||||
eventType: "ALERT",
|
||||
name: "secureInclusion",
|
||||
value: "failed",
|
||||
isStateChange: true,
|
||||
)
|
||||
}
|
||||
} else if (description != "updated") {
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x25: 1, 0x30: 1, 0x31: 5, 0x80: 1, 0x84: 1, 0x71: 3, 0x9C: 1])
|
||||
if (cmd) {
|
||||
result = zwaveEvent(cmd)
|
||||
}
|
||||
}
|
||||
log.debug "parsed '$description' to $result"
|
||||
return result
|
||||
}
|
||||
|
||||
def updated() {
|
||||
def cmds = []
|
||||
if (!state.MSR) {
|
||||
cmds = [
|
||||
command(zwave.manufacturerSpecificV2.manufacturerSpecificGet()),
|
||||
"delay 1200",
|
||||
zwave.wakeUpV1.wakeUpNoMoreInformation().format()
|
||||
]
|
||||
} else if (!state.lastbat) {
|
||||
cmds = []
|
||||
} else {
|
||||
cmds = [zwave.wakeUpV1.wakeUpNoMoreInformation().format()]
|
||||
}
|
||||
response(cmds)
|
||||
}
|
||||
|
||||
def configure() {
|
||||
commands([
|
||||
zwave.manufacturerSpecificV2.manufacturerSpecificGet(),
|
||||
zwave.batteryV1.batteryGet()
|
||||
], 6000)
|
||||
}
|
||||
|
||||
def sensorValueEvent(value) {
|
||||
if (value) {
|
||||
createEvent(name: "contact", value: "open", descriptionText: "$device.displayName is open")
|
||||
} else {
|
||||
createEvent(name: "contact", value: "closed", descriptionText: "$device.displayName is closed")
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd)
|
||||
{
|
||||
sensorValueEvent(cmd.value)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd)
|
||||
{
|
||||
sensorValueEvent(cmd.value)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd)
|
||||
{
|
||||
sensorValueEvent(cmd.value)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.sensorbinaryv1.SensorBinaryReport cmd)
|
||||
{
|
||||
sensorValueEvent(cmd.sensorValue)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.sensoralarmv1.SensorAlarmReport cmd)
|
||||
{
|
||||
sensorValueEvent(cmd.sensorState)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.notificationv3.NotificationReport cmd)
|
||||
{
|
||||
def result = []
|
||||
if (cmd.notificationType == 0x06 && cmd.event == 0x16) {
|
||||
result << sensorValueEvent(1)
|
||||
} else if (cmd.notificationType == 0x06 && cmd.event == 0x17) {
|
||||
result << sensorValueEvent(0)
|
||||
} else if (cmd.notificationType == 0x07) {
|
||||
if (cmd.v1AlarmType == 0x07) { // special case for nonstandard messages from Monoprice door/window sensors
|
||||
result << sensorValueEvent(cmd.v1AlarmLevel)
|
||||
} else if (cmd.event == 0x01 || cmd.event == 0x02) {
|
||||
result << sensorValueEvent(1)
|
||||
} else if (cmd.event == 0x03) {
|
||||
result << createEvent(descriptionText: "$device.displayName covering was removed", isStateChange: true)
|
||||
if(!state.MSR) result << response(command(zwave.manufacturerSpecificV2.manufacturerSpecificGet()))
|
||||
} else if (cmd.event == 0x05 || cmd.event == 0x06) {
|
||||
result << createEvent(descriptionText: "$device.displayName detected glass breakage", isStateChange: true)
|
||||
} else if (cmd.event == 0x07) {
|
||||
if(!state.MSR) result << response(command(zwave.manufacturerSpecificV2.manufacturerSpecificGet()))
|
||||
result << createEvent(name: "motion", value: "active", descriptionText:"$device.displayName detected motion")
|
||||
}
|
||||
} else if (cmd.notificationType) {
|
||||
def text = "Notification $cmd.notificationType: event ${([cmd.event] + cmd.eventParameter).join(", ")}"
|
||||
result << createEvent(name: "notification$cmd.notificationType", value: "$cmd.event", descriptionText: text, displayed: false)
|
||||
} else {
|
||||
def value = cmd.v1AlarmLevel == 255 ? "active" : cmd.v1AlarmLevel ?: "inactive"
|
||||
result << createEvent(name: "alarm $cmd.v1AlarmType", value: value, displayed: false)
|
||||
}
|
||||
result
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.wakeupv1.WakeUpNotification cmd)
|
||||
{
|
||||
def event = createEvent(descriptionText: "${device.displayName} woke up", isStateChange: false)
|
||||
def cmds = []
|
||||
if (!state.MSR) {
|
||||
cmds << command(zwave.manufacturerSpecificV2.manufacturerSpecificGet())
|
||||
cmds << "delay 1200"
|
||||
}
|
||||
if (!state.lastbat || now() - state.lastbat > 53*60*60*1000) {
|
||||
cmds << command(zwave.batteryV1.batteryGet())
|
||||
} else {
|
||||
cmds << zwave.wakeUpV1.wakeUpNoMoreInformation().format()
|
||||
}
|
||||
[event, response(cmds)]
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
|
||||
def map = [ name: "battery", unit: "%" ]
|
||||
if (cmd.batteryLevel == 0xFF) {
|
||||
map.value = 1
|
||||
map.descriptionText = "${device.displayName} has a low battery"
|
||||
map.isStateChange = true
|
||||
} else {
|
||||
map.value = cmd.batteryLevel
|
||||
}
|
||||
state.lastbat = now()
|
||||
[createEvent(map), response(zwave.wakeUpV1.wakeUpNoMoreInformation())]
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerSpecificReport cmd) {
|
||||
def result = []
|
||||
|
||||
def msr = String.format("%04X-%04X-%04X", cmd.manufacturerId, cmd.productTypeId, cmd.productId)
|
||||
log.debug "msr: $msr"
|
||||
updateDataValue("MSR", msr)
|
||||
|
||||
retypeBasedOnMSR()
|
||||
|
||||
result << createEvent(descriptionText: "$device.displayName MSR: $msr", isStateChange: false)
|
||||
|
||||
if (msr == "011A-0601-0901") { // Enerwave motion doesn't always get the associationSet that the hub sends on join
|
||||
result << response(zwave.associationV1.associationSet(groupingIdentifier:1, nodeId:zwaveHubNodeId))
|
||||
} else if (!device.currentState("battery")) {
|
||||
if (msr == "0086-0102-0059") {
|
||||
result << response(zwave.securityV1.securityMessageEncapsulation().encapsulate(zwave.batteryV1.batteryGet()).format())
|
||||
} else {
|
||||
result << response(command(zwave.batteryV1.batteryGet()))
|
||||
}
|
||||
}
|
||||
|
||||
result
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
|
||||
def encapsulatedCommand = cmd.encapsulatedCommand([0x20: 1, 0x25: 1, 0x30: 1, 0x31: 5, 0x80: 1, 0x84: 1, 0x71: 3, 0x9C: 1])
|
||||
// log.debug "encapsulated: $encapsulatedCommand"
|
||||
if (encapsulatedCommand) {
|
||||
state.sec = 1
|
||||
zwaveEvent(encapsulatedCommand)
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
createEvent(descriptionText: "$device.displayName: $cmd", displayed: false)
|
||||
}
|
||||
|
||||
private command(physicalgraph.zwave.Command cmd) {
|
||||
if (state.sec == 1) {
|
||||
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
|
||||
} else {
|
||||
cmd.format()
|
||||
}
|
||||
}
|
||||
|
||||
private commands(commands, delay=200) {
|
||||
delayBetween(commands.collect{ command(it) }, delay)
|
||||
}
|
||||
|
||||
def retypeBasedOnMSR() {
|
||||
switch (state.MSR) {
|
||||
case "0086-0002-002D":
|
||||
log.debug "Changing device type to Z-Wave Water Sensor"
|
||||
setDeviceType("Z-Wave Water Sensor")
|
||||
break
|
||||
case "011F-0001-0001": // Schlage motion
|
||||
case "014A-0001-0001": // Ecolink motion
|
||||
case "014A-0004-0001": // Ecolink motion +
|
||||
case "0060-0001-0002": // Everspring SP814
|
||||
case "0060-0001-0003": // Everspring HSP02
|
||||
case "011A-0601-0901": // Enerwave ZWN-BPC
|
||||
case "0214-0002-0002": // Besense pir or ceiling sensor
|
||||
log.debug "Changing device type to Z-Wave Motion Sensor"
|
||||
setDeviceType("Z-Wave Motion Sensor")
|
||||
break
|
||||
case "013C-0002-000D": // Philio multi +
|
||||
log.debug "Changing device type to 3-in-1 Multisensor Plus (SG)"
|
||||
setDeviceType("3-in-1 Multisensor Plus (SG)")
|
||||
break
|
||||
case "0109-2001-0106": // Vision door/window
|
||||
log.debug "Changing device type to Z-Wave Plus Door/Window Sensor"
|
||||
setDeviceType("Z-Wave Plus Door/Window Sensor")
|
||||
break
|
||||
case "0109-2002-0205": // Vision Motion
|
||||
log.debug "Changing device type to Z-Wave Plus Motion/Temp Sensor"
|
||||
setDeviceType("Z-Wave Plus Motion/Temp Sensor")
|
||||
break
|
||||
}
|
||||
}
|
||||
@@ -14,6 +14,7 @@ metadata {
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Health Check"
|
||||
capability "Light"
|
||||
}
|
||||
|
||||
simulator {
|
||||
|
||||
@@ -13,6 +13,7 @@ metadata {
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Health Check"
|
||||
capability "Light"
|
||||
}
|
||||
|
||||
simulator {
|
||||
|
||||
@@ -36,6 +36,7 @@ metadata {
|
||||
capability "Switch"
|
||||
capability "Refresh"
|
||||
capability "Contact Sensor"
|
||||
capability "Light"
|
||||
|
||||
attribute "powered", "string"
|
||||
|
||||
|
||||
@@ -23,6 +23,7 @@ Works with:
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Switch Level** - represents current light level, usually 0-100 in percent
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
* **Light** - indicates that the device belongs to Light category.
|
||||
|
||||
## Device Health
|
||||
|
||||
|
||||
@@ -22,6 +22,7 @@ metadata {
|
||||
capability "Switch"
|
||||
capability "Switch Level"
|
||||
capability "Health Check"
|
||||
capability "Light"
|
||||
|
||||
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0B04"
|
||||
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 0702"
|
||||
|
||||
@@ -21,6 +21,7 @@ metadata {
|
||||
capability "Sensor"
|
||||
capability "Switch"
|
||||
capability "Health Check"
|
||||
capability "Light"
|
||||
|
||||
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0B04"
|
||||
fingerprint profileId: "0104", inClusters: "0000, 0003, 0004, 0005, 0006, 0702"
|
||||
|
||||
@@ -6,6 +6,12 @@ Works with:
|
||||
|
||||
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW)](https://www.smartthings.com/works-with-smartthings/outlets/leviton-plug-in-lamp-dimmer-module)
|
||||
* [Leviton Universal Dimmer (DZMX1-LZ)](https://www.smartthings.com/works-with-smartthings/switches-and-dimmers/leviton-universal-dimmer)
|
||||
* [Leviton 1000W Incandescent Dimmer](https://www.smartthings.com/works-with-smartthings/leviton/leviton-1000w-incandescent-dimmer)
|
||||
* [Leviton 600W Incandescent Dimmer](https://www.smartthings.com/works-with-smartthings/leviton/leviton-600w-incandescent-dimmer)
|
||||
* [Enerwave In-Wall Dimmer](https://www.smartthings.com/works-with-smartthings/enerwave/enerwave-in-wall-dimmer-zw500d)
|
||||
* [Leviton 3-Speed Fan Controller](https://www.smartthings.com/works-with-smartthings/leviton/leviton-3-speed-fan-controller)
|
||||
* [Leviton Magnetic Low Voltage Dimmer](https://www.smartthings.com/works-with-smartthings/leviton/leviton-magnetic-low-voltage-dimmer)
|
||||
* [Remotec Technology Plug-In Dimmer](https://www.smartthings.com/works-with-smartthings/remotec-technology/remotec-technology-plug-in-dimmer)
|
||||
|
||||
## Table of contents
|
||||
|
||||
@@ -40,4 +46,9 @@ If the device doesn't pair when trying from the SmartThings mobile app, it is po
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [Leviton Plug-in Lamp Dimmer Module (DZPD3-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
|
||||
* [Leviton Universal Dimmer (DZMX1-LZ) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
|
||||
* [Leviton Universal Dimmer (DZMX1-LZ) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
|
||||
* [Leviton 1000W Incandescent Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
|
||||
* [Leviton 600W Incandescent Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
|
||||
* [Leviton 3-Speed Fan Controller Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/206171053-How-to-connect-Leviton-Z-Wave-devices)
|
||||
* [Enerwave In-Wall Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/204854176-How-to-connect-Enerwave-switches-and-dimmers)
|
||||
* [Remotec Technology Plug-In Dimmer Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202295150-Remotec-Technology-Plug-In-Dimmer-ZDS-100-)
|
||||
@@ -20,6 +20,7 @@ metadata {
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Light"
|
||||
|
||||
fingerprint inClusters: "0x26", deviceJoinName: "Z-Wave Dimmer"
|
||||
fingerprint mfr:"001D", prod:"1902", deviceJoinName: "Z-Wave Dimmer"
|
||||
@@ -28,6 +29,8 @@ metadata {
|
||||
fingerprint mfr:"001D", prod:"1001", model:"0334", deviceJoinName: "Leviton 3-Speed Fan Controller"
|
||||
fingerprint mfr:"001D", prod:"0602", model:"0334", deviceJoinName: "Leviton Magnetic Low Voltage Dimmer"
|
||||
fingerprint mfr:"001D", prod:"0401", model:"0334", deviceJoinName: "Leviton 600W Incandescent Dimmer"
|
||||
fingerprint mfr:"0111", prod:"8200", model:"0200", deviceJoinName: "Remotec Technology Plug-In Dimmer"
|
||||
fingerprint mfr:"1104", prod:"001D", model:"0501", deviceJoinName: "Leviton 1000W Incandescant Dimmer"
|
||||
}
|
||||
|
||||
simulator {
|
||||
|
||||
@@ -25,6 +25,7 @@ metadata {
|
||||
capability "Switch Level"
|
||||
capability "Sensor"
|
||||
capability "Actuator"
|
||||
capability "Light"
|
||||
|
||||
command "reset"
|
||||
|
||||
|
||||
@@ -21,6 +21,7 @@ metadata {
|
||||
capability "Refresh"
|
||||
capability "Configuration"
|
||||
capability "Sensor"
|
||||
capability "Light"
|
||||
|
||||
command "reset"
|
||||
|
||||
|
||||
@@ -19,6 +19,7 @@ metadata {
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Light"
|
||||
|
||||
fingerprint inClusters: "0x25", deviceJoinName: "Z-Wave Switch"
|
||||
fingerprint mfr:"001D", prod:"1A02", model:"0334", deviceJoinName: "Leviton Appliance Module"
|
||||
@@ -26,6 +27,8 @@ metadata {
|
||||
fingerprint mfr:"001D", prod:"1D04", model:"0334", deviceJoinName: "Leviton Outlet"
|
||||
fingerprint mfr:"001D", prod:"1C02", model:"0334", deviceJoinName: "Leviton Switch"
|
||||
fingerprint mfr:"001D", prod:"0301", model:"0334", deviceJoinName: "Leviton 15A Switch"
|
||||
fingerprint mfr:"001D", prod:"0F01", model:"0334", deviceJoinName: "Leviton 5A Incandescent Switch"
|
||||
fingerprint mfr:"001D", prod:"1603", model:"0334", deviceJoinName: "Leviton 15A Split Duplex Receptacle"
|
||||
fingerprint mfr:"011A", prod:"0101", model:"0102", deviceJoinName: "Enerwave On/Off Switch"
|
||||
fingerprint mfr:"011A", prod:"0101", model:"0603", deviceJoinName: "Enerwave Duplex Receptacle"
|
||||
}
|
||||
|
||||
@@ -20,6 +20,7 @@ metadata {
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Health Check"
|
||||
capability "Light"
|
||||
|
||||
fingerprint mfr:"0063", prod:"4952", deviceJoinName: "Z-Wave Wall Switch"
|
||||
fingerprint mfr:"0063", prod:"5257", deviceJoinName: "Z-Wave Wall Switch"
|
||||
|
||||
Reference in New Issue
Block a user