mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-09 13:21:53 +00:00
Compare commits
10 Commits
PROD_2016.
...
MSA-1544-1
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
a9aee8fd96 | ||
|
|
5c015cf678 | ||
|
|
cf1a46e309 | ||
|
|
1ff77dc608 | ||
|
|
afbec02217 | ||
|
|
434a72bd13 | ||
|
|
3fba7c9422 | ||
|
|
b63d4a9156 | ||
|
|
6eb29ad019 | ||
|
|
711cdc3ebf |
2
devicetypes/smartthings/dimmer-switch.src/.st-ignore
Normal file
2
devicetypes/smartthings/dimmer-switch.src/.st-ignore
Normal file
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
45
devicetypes/smartthings/dimmer-switch.src/README.md
Normal file
45
devicetypes/smartthings/dimmer-switch.src/README.md
Normal file
@@ -0,0 +1,45 @@
|
||||
# Z-wave Dimmer Switch
|
||||
|
||||
|
||||
|
||||
Works with:
|
||||
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (GE 12724)](http://products.z-wavealliance.org/products/1197)
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (Toggle) (GE 12729)](http://products.z-wavealliance.org/products/1201)
|
||||
* [GE Z-Wave Plug-in Smart Dimmer (GE 12718)](http://products.z-wavealliance.org/products/1191)
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
* [Troubleshooting](#Troubleshooting)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Switch Level** - it's defined to accept two parameters, the level and the rate of dimming
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Indicator** - gives you the ability to set the indicator LED light on a Z-Wave switch
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Polling** - represents that poll() can be implemented for the device
|
||||
* **Refresh** - _refresh()_ command for status updates
|
||||
* **Sensor** - detects sensor events
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
|
||||
## Device Health
|
||||
|
||||
Z-Wave Smart Dimmers (In-Wall, In-Wall(Toggle), Plug-In) are polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Check-in interval = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [General Z-Wave Dimmer/Switch Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200955890-Troubleshooting-GE-in-wall-switch-or-dimmer-won-t-respond-to-commands-or-automations-Z-Wave-)
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (GE 12724) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200902600-GE-In-Wall-Paddle-Dimmer-Switch-GE-12724-Z-Wave-)
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (Toggle) (GE 12729) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/207568463-GE-In-Wall-Smart-Toggle-Dimmer-GE-12729-Z-Wave-)
|
||||
* [GE Z-Wave Plug-in Smart Dimmer (GE 12718) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202088474-GE-Plug-In-Smart-Dimmer-GE-12718-Z-Wave-)
|
||||
@@ -20,6 +20,7 @@ metadata {
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Health Check"
|
||||
|
||||
fingerprint mfr:"0063", prod:"4457", deviceJoinName: "Z-Wave Wall Dimmer"
|
||||
fingerprint mfr:"0063", prod:"4944", deviceJoinName: "Z-Wave Wall Dimmer"
|
||||
@@ -82,6 +83,8 @@ metadata {
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
switch (ledIndicator) {
|
||||
case "on":
|
||||
indicatorWhenOn()
|
||||
@@ -215,6 +218,13 @@ def poll() {
|
||||
zwave.switchMultilevelV1.switchMultilevelGet().format()
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
log.debug "refresh() is called"
|
||||
def commands = []
|
||||
|
||||
@@ -11,6 +11,9 @@
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
*/
|
||||
import groovy.transform.Field
|
||||
|
||||
@Field Boolean hasConfiguredHealthCheck = false
|
||||
|
||||
metadata {
|
||||
definition (name: "ZLL Dimmer Bulb", namespace: "smartthings", author: "SmartThings") {
|
||||
@@ -21,6 +24,7 @@ metadata {
|
||||
capability "Refresh"
|
||||
capability "Switch"
|
||||
capability "Switch Level"
|
||||
capability "Health Check"
|
||||
|
||||
//fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0000,0019"
|
||||
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0019"
|
||||
@@ -96,7 +100,38 @@ def poll() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh()
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
return zigbee.levelRefresh()
|
||||
}
|
||||
|
||||
def healthPoll() {
|
||||
log.debug "healthPoll()"
|
||||
def cmds = refresh()
|
||||
cmds.each{ sendHubCommand(new physicalgraph.device.HubAction(it))}
|
||||
}
|
||||
|
||||
def configureHealthCheck() {
|
||||
Integer hcIntervalMinutes = 12
|
||||
if (!hasConfiguredHealthCheck) {
|
||||
log.debug "Configuring Health Check, Reporting"
|
||||
unschedule("healthPoll")
|
||||
runEvery5Minutes("healthPoll")
|
||||
// Device-Watch allows 2 check-in misses from device
|
||||
sendEvent(name: "checkInterval", value: hcIntervalMinutes * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
hasConfiguredHealthCheck = true
|
||||
}
|
||||
}
|
||||
|
||||
def configure() {
|
||||
log.debug "configure()"
|
||||
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh()
|
||||
configureHealthCheck()
|
||||
}
|
||||
|
||||
def updated() {
|
||||
log.debug "updated()"
|
||||
configureHealthCheck()
|
||||
}
|
||||
|
||||
@@ -11,6 +11,9 @@
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
*/
|
||||
import groovy.transform.Field
|
||||
|
||||
@Field Boolean hasConfiguredHealthCheck = false
|
||||
|
||||
metadata {
|
||||
definition (name: "ZLL White Color Temperature Bulb", namespace: "smartthings", author: "SmartThings") {
|
||||
@@ -22,6 +25,7 @@ metadata {
|
||||
capability "Refresh"
|
||||
capability "Switch"
|
||||
capability "Switch Level"
|
||||
capability "Health Check"
|
||||
|
||||
attribute "colorName", "string"
|
||||
command "setGenericName"
|
||||
@@ -96,9 +100,41 @@ def poll() {
|
||||
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh()
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
return zigbee.levelRefresh()
|
||||
}
|
||||
|
||||
def healthPoll() {
|
||||
log.debug "healthPoll()"
|
||||
def cmds = zigbee.onOffRefresh() + zigbee.levelRefresh()
|
||||
cmds.each{ sendHubCommand(new physicalgraph.device.HubAction(it))}
|
||||
}
|
||||
|
||||
def configureHealthCheck() {
|
||||
Integer hcIntervalMinutes = 12
|
||||
if (!hasConfiguredHealthCheck) {
|
||||
log.debug "Configuring Health Check, Reporting"
|
||||
unschedule("healthPoll")
|
||||
runEvery5Minutes("healthPoll")
|
||||
// Device-Watch allows 2 check-in misses from device
|
||||
sendEvent(name: "checkInterval", value: hcIntervalMinutes * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
hasConfiguredHealthCheck = true
|
||||
}
|
||||
}
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
log.debug "configure()"
|
||||
configureHealthCheck()
|
||||
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.colorTemperatureConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh()
|
||||
|
||||
}
|
||||
|
||||
def updated() {
|
||||
log.debug "updated()"
|
||||
configureHealthCheck()
|
||||
}
|
||||
|
||||
def setColorTemperature(value) {
|
||||
|
||||
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
39
devicetypes/smartthings/zwave-switch-generic.src/README.md
Normal file
39
devicetypes/smartthings/zwave-switch-generic.src/README.md
Normal file
@@ -0,0 +1,39 @@
|
||||
# Z-wave Switch
|
||||
|
||||
|
||||
|
||||
Works with:
|
||||
|
||||
* [Leviton Appliance Module (DZPA1-1LW)](https://support.smartthings.com/hc/en-us/articles/205881176-Leviton-Appliance-Module-DZPA1-1LW-)
|
||||
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave)](https://support.smartthings.com/hc/en-us/articles/200903080-GE-Plug-In-Outdoor-Smart-Switch-GE-12720-Z-Wave-)
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Polling** - represents that poll() can be implemented for the device
|
||||
* **Refresh** - _refresh()_ command for status updates
|
||||
* **Sensor** - detects sensor events
|
||||
|
||||
## Device Health
|
||||
|
||||
A Category C5 Leviton Appliance Module (DZPA1-1LW) and GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [Leviton Appliance Module (DZPA1-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205881176-Leviton-Appliance-Module-DZPA1-1LW-)
|
||||
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200903080-GE-Plug-In-Outdoor-Smart-Switch-GE-12720-Z-Wave-)
|
||||
@@ -14,12 +14,15 @@
|
||||
metadata {
|
||||
definition (name: "Z-Wave Switch Generic", namespace: "smartthings", author: "SmartThings") {
|
||||
capability "Actuator"
|
||||
capability "Health Check"
|
||||
capability "Switch"
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
|
||||
fingerprint inClusters: "0x25", deviceJoinName: "Z-Wave Switch"
|
||||
fingerprint mfr:"001D", prod:"1A02", deviceJoinName: "Z-Wave Switch"
|
||||
fingerprint mfr:"0063", prod:"4F50", deviceJoinName: "Z-Wave Switch"
|
||||
}
|
||||
|
||||
// simulator metadata
|
||||
@@ -50,6 +53,11 @@ metadata {
|
||||
}
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for checkInterval duration of 32min = 2 * 15min + 2min lag time
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def result = null
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x70: 1])
|
||||
@@ -126,6 +134,13 @@ def poll() {
|
||||
])
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
delayBetween([
|
||||
zwave.switchBinaryV1.switchBinaryGet().format(),
|
||||
|
||||
2
devicetypes/smartthings/zwave-switch.src/.st-ignore
Normal file
2
devicetypes/smartthings/zwave-switch.src/.st-ignore
Normal file
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
49
devicetypes/smartthings/zwave-switch.src/README.md
Normal file
49
devicetypes/smartthings/zwave-switch.src/README.md
Normal file
@@ -0,0 +1,49 @@
|
||||
# Z-Wave Switch
|
||||
|
||||
|
||||
Works with:
|
||||
|
||||
* [GE Z-Wave Plug-In Smart Switch (12719)](http://products.z-wavealliance.org/products/1193)
|
||||
* [GE Z-Wave In-Wall Smart Outlet (12721)](http://products.z-wavealliance.org/products/1195)
|
||||
* [GE Z-Wave In-Wall Smart Switch (12722)](http://products.z-wavealliance.org/products/1196)
|
||||
* [GE Z-Wave In-Wall Smart Toggle Switch (12727)](http://products.z-wavealliance.org/products/1200)
|
||||
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
* [Troubleshooting](#Troubleshooting)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Indicator** - gives you the ability to set the indicator LED light on a Z-Wave switch
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Polling** - represents that poll() can be implemented for the device
|
||||
* **Refresh** - _refresh()_ command for status updates
|
||||
* **Sensor** - detects sensor events
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
|
||||
## Device Health
|
||||
|
||||
Z-Wave Switches (Plug-In, In-Wall(Toggle Switch, Switch, Outlet)) are polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [General Z-Wave Dimmer/Switch Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200955890-Troubleshooting-GE-in-wall-switch-or-dimmer-won-t-respond-to-commands-or-automations-Z-Wave-)
|
||||
* [GE Z-Wave Plug-In Smart Switch (12719) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200903070-GE-Plug-In-Smart-Switch-GE-12719-Z-Wave)
|
||||
* [GE Z-Wave In-Wall Smart Outlet (12721) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200903020-GE-In-Wall-Smart-Outlet-GE-12721-Z-Wave)
|
||||
* [GE Z-Wave In-Wall Smart Switch (12722) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200902540-GE-In-Wall-Smart-Switch-GE-12722-Z-Wave)
|
||||
* [GE Z-Wave In-Wall Smart Toggle Switch (12727) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/207568933-GE-In-Wall-Smart-Toggle-Switch-GE-12727-Z-Wave)
|
||||
|
||||
|
||||
@@ -19,6 +19,7 @@ metadata {
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Health Check"
|
||||
|
||||
fingerprint mfr:"0063", prod:"4952", deviceJoinName: "Z-Wave Wall Switch"
|
||||
fingerprint mfr:"0063", prod:"5257", deviceJoinName: "Z-Wave Wall Switch"
|
||||
@@ -64,6 +65,8 @@ metadata {
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
switch (ledIndicator) {
|
||||
case "on":
|
||||
indicatorWhenOn()
|
||||
@@ -156,6 +159,13 @@ def poll() {
|
||||
])
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
**/
|
||||
def ping() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
delayBetween([
|
||||
zwave.switchBinaryV1.switchBinaryGet().format(),
|
||||
|
||||
Reference in New Issue
Block a user