Compare commits

..

18 Commits

Author SHA1 Message Date
jackchi
8197097e1d Revert "Added health-check for FortrezZ Siren Strobe Alarm"
This reverts commit 7a7a08ea6e.
2017-04-06 14:15:08 -07:00
Vinay Rao
36fe6428ab Merge pull request #1878 from SmartThingsCommunity/master
Rolling up master to staging
2017-04-04 14:42:18 -07:00
Vinay Rao
2bc44e0205 Merge pull request #1877 from SmartThingsCommunity/staging
Rolling down staging to master
2017-04-04 14:41:02 -07:00
Vinay Rao
24d079db7c Merge pull request #1876 from SmartThingsCommunity/revert-1870-revert-phase2
Revert "[CHF-571] [CHF-568] Revert untested Health Check on Keen Home EcoNet"
2017-04-04 14:39:37 -07:00
Vinay Rao
283ed425d8 Merge pull request #1875 from SmartThingsCommunity/revert-1872-revert-harmony
CHF-574 Revert "Revert "Added health-check for Logitech Harmony Hub""
2017-04-04 14:39:10 -07:00
Vinay Rao
1545707ae3 Revert "[CHF-571] [CHF-568] Revert untested Health Check on Keen Home EcoNet" 2017-04-04 14:38:54 -07:00
Vinay Rao
2fd8cf1416 Revert "Revert "Added health-check for Logitech Harmony Hub"" 2017-04-04 14:38:11 -07:00
Vinay Rao
fe4a5239c7 Merge pull request #1869 from SmartThingsCommunity/staging
Rolling down staging to master
2017-04-03 15:59:49 -07:00
Vinay Rao
ec781b18be Merge pull request #1865 from CosmicPuppy/ActionTiles-Wattvision-CapabilitySensor-Patch
To Wattvision power metering Sensor DTH, added Capability "Sensor"
2017-04-03 03:08:10 -07:00
CosmicPuppy
43bedd41a8 To Wattvision power metering Sensor DTH, added Capability "Sensor" per http://docs.smartthings.com/en/latest/device-type-developers-guide/overview.html?highlight=sensor%20actuator#actuator-and-sensor. 2017-04-03 00:21:11 -07:00
Jack Chi
f75e8a6b2d Merge pull request #1853 from parijatdas/zigbee_lock
[CHF-557] Health Check ZigBee Lock
2017-04-02 09:50:44 -07:00
Parijat Das
515fab9fa4 Added health-check for Zigbee Lock 2017-03-30 17:22:43 -07:00
Vinay Rao
100e696d02 Merge pull request #1857 from varzac/fix-humidity-configuration
Support config on both temp-humidty firmwares
2017-03-30 16:58:12 -07:00
Vinay Rao
3e988ce657 Merge pull request #1860 from SmartThingsCommunity/staging
Rolling down staging to master
2017-03-30 15:50:32 -07:00
Zach Varberg
00224c2d0b Support config on both temp-humidty firmwares
This solves an issue with invalid configuration of the reporting for
humidity on the smartsense-temp-humidity-sensor.  This issue was masked
by the fact that the device has a default configuration for reporting
humidity, but the configuration has never been valid as it used an
incorrect dataType for the configuration.

This resolves: https://smartthings.atlassian.net/browse/DPROT-263
This resolves: https://smartthings.atlassian.net/browse/EBF-1205
This resolves: https://smartthings.atlassian.net/browse/DVCSMP-2420
2017-03-30 15:44:40 -05:00
Jack Chi
f05daf2f34 Merge pull request #1538 from pchomal/zwave_metering_dimmer
[CHF-482] Health Check implementation for Z-Wave Metering Dimmer
2017-03-29 14:42:39 -07:00
Piyush Chomal
6fae023f7a Merge branch 'master' into zwave_metering_dimmer 2017-03-22 22:57:47 +05:30
piyush.c
ef8611d2ea [CHF-482]
Health Check implementation for Z-Wave Metering Dimmer
2016-12-22 13:14:35 +05:30
12 changed files with 102 additions and 66 deletions

View File

@@ -11,7 +11,7 @@ metadata {
capability "Sensor"
capability "Temperature Measurement"
capability "Battery"
// capability "Health Check"
capability "Health Check"
command "getLevel"
command "getOnOff"
@@ -476,7 +476,7 @@ def configure() {
// Device-Watch allows 2 check-in misses from device + ping (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
// sendEvent(name: "checkInterval", value: 2 * 10 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
sendEvent(name: "checkInterval", value: 2 * 10 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
// get ZigBee ID by hidden tile because that's the only way we can do it
setZigBeeIdTile()

View File

@@ -26,13 +26,13 @@ metadata {
capability "Sensor"
capability "Polling"
capability "Configuration"
// capability "Health Check"
capability "Health Check"
command "open"
command "close"
fingerprint deviceId: "0x1100", inClusters: "0x26,0x72,0x86,0x77,0x80,0x20"
// fingerprint mfr:"0157", prod:"0100", model:"0100", deviceJoinName: "EcoNet Controls Z-Wave Vent"
fingerprint mfr:"0157", prod:"0100", model:"0100", deviceJoinName: "EcoNet Controls Z-Wave Vent"
}
simulator {
@@ -88,7 +88,7 @@ def parse(String description) {
//send the command to stop polling
def updated() {
// Device-Watch simply pings if no device events received for 32min(checkInterval)
// sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
response("poll stop")
}

View File

@@ -7,6 +7,7 @@ metadata {
definition (name: "Logitech Harmony Hub C2C", namespace: "smartthings", author: "SmartThings") {
capability "Media Controller"
capability "Refresh"
capability "Health Check"
command "activityoff"
command "alloff"
@@ -38,6 +39,16 @@ metadata {
}
}
def installed() {
log.debug "installed()"
sendEvent(name: "DeviceWatch-Enroll", value: JsonOutput.toJson([protocol: "cloud", scheme:"untracked"]), displayed: false)
}
def updated() {
log.debug "updated()"
sendEvent(name: "DeviceWatch-Enroll", value: JsonOutput.toJson([protocol: "cloud", scheme:"untracked"]), displayed: false)
}
def startActivity(String activityId) {
log.debug "Executing 'Start Activity'"
log.trace parent.activity("$device.deviceNetworkId-$activityId","start")
@@ -58,6 +69,10 @@ def poll() {
log.trace parent.poll()
}
def ping() {
refresh()
}
def refresh() {
log.debug "Executing 'Refresh'"
log.trace parent.poll()

View File

@@ -135,10 +135,7 @@ def refresh() {
return zigbee.readAttribute(0xFC45, 0x0000, ["mfgCode": 0x104E]) + // New firmware
zigbee.readAttribute(0xFC45, 0x0000, ["mfgCode": 0xC2DF]) + // Original firmware
zigbee.readAttribute(zigbee.TEMPERATURE_MEASUREMENT_CLUSTER, 0x0000) +
zigbee.readAttribute(zigbee.POWER_CONFIGURATION_CLUSTER, 0x0020) +
zigbee.configureReporting(0xFC45, 0x0000, DataType.INT16, 30, 3600, 100) +
zigbee.batteryConfig() +
zigbee.temperatureConfig(30, 300)
zigbee.readAttribute(zigbee.POWER_CONFIGURATION_CLUSTER, 0x0020)
}
def configure() {
@@ -150,5 +147,10 @@ def configure() {
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
// battery minReport 30 seconds, maxReportTime 6 hrs by default
return refresh()
return refresh() +
zigbee.configureReporting(0xFC45, 0x0000, DataType.UINT16, 30, 3600, 100, ["mfgCode": 0x104E]) + // New firmware
zigbee.configureReporting(0xFC45, 0x0000, DataType.UINT16, 30, 3600, 100, ["mfgCode": 0xC2DF]) + // Original firmware
zigbee.batteryConfig() +
zigbee.temperatureConfig(30, 300)
}

View File

@@ -20,6 +20,7 @@ metadata {
definition(name: "Wattvision", namespace: "smartthings", author: "Steve Vlaminck") {
capability "Power Meter"
capability "Refresh"
capability "Sensor"
attribute "powerContent", "string"
}

View File

@@ -0,0 +1,46 @@
# Zigbee Lock
Cloud Execution
Works with:
* [Yale Push Button Deadbolt (YRD210-HA)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-push-button-deadbolt-yrd210)
* [Yale Touchscreen Lever (YRL220-ZB)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-touchscreen-lever-yrl220)
* [Yale Touchscreen Deadbolt (YRD220-HA))](https://www.smartthings.com/works-with-smartthings/door-locks/yale-touchscreen-deadbolt-yrd220)
* [Yale Key Free Touchscreen Deadbolt (YRD240-HA)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-key-free-touchscreen-deadbolt-yrd240)
* [Yale Push Button Lever Lock (YRL210-HA)](https://www.smartthings.com/works-with-smartthings/door-locks/yale-push-button-lever-lock-yrl210)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Battery](#battery-specification)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Lock** - allows for the control of a lock device
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - detects sensor events
* **Battery** - defines device uses a battery
* **Configuration** - _configure()_ command called when device is installed or device preferences updated
* **Health Check** - indicates ability to get device health notifications
## Device Health
Yale Push Button Deadbolt (YRD210-HA) is a Zigbee device and checks in every 1 hour.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*60 + 2)mins = 122 mins.
* __122min__ checkInterval
## Battery Specification
Four AA 1.5V batteries are required.
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the sensor from SmartThings can be found in the following link:
* [Yale Locks Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205138400)

View File

@@ -24,6 +24,7 @@ import physicalgraph.zigbee.zcl.DataType
capability "Sensor"
capability "Battery"
capability "Configuration"
capability "Health Check"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0004,0005,0009,0020,0101,0402,0B05,FDBD", outClusters: "000A,0019", manufacturer: "Kwikset", model: "SMARTCODE_DEADBOLT_5", deviceJoinName: "Kwikset 5-Button Deadbolt"
fingerprint profileId: "0104", inClusters: "0000,0001,0003,0004,0005,0009,0020,0101,0402,0B05,FDBD", outClusters: "000A,0019", manufacturer: "Kwikset", model: "SMARTCODE_LEVER_5", deviceJoinName: "Kwikset 5-Button Lever"
@@ -83,6 +84,9 @@ def uninstalled() {
}
def configure() {
// Device-Watch allows 2 check-in misses from device + ping (plus 2 min lag time)
sendEvent(name: "checkInterval", value: 2 * 60 * 60 + 2 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
def cmds =
zigbee.configureReporting(CLUSTER_DOORLOCK, DOORLOCK_ATTR_LOCKSTATE,
DataType.ENUM8, 0, 3600, null) +
@@ -92,6 +96,13 @@ def configure() {
return refresh() + cmds // send refresh cmds as part of config
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
zigbee.readAttribute(CLUSTER_DOORLOCK, DOORLOCK_ATTR_LOCKSTATE)
}
def refresh() {
def cmds =
zigbee.readAttribute(CLUSTER_DOORLOCK, DOORLOCK_ATTR_LOCKSTATE) +

View File

@@ -25,11 +25,13 @@ metadata {
capability "Switch Level"
capability "Sensor"
capability "Actuator"
capability "Health Check"
capability "Light"
command "reset"
fingerprint inClusters: "0x26,0x32"
fingerprint mfr:"0086", prod:"0003", model:"001B", deviceJoinName: "Aeon Labs Micro Smart Dimmer 2E"
}
simulator {
@@ -99,6 +101,9 @@ def parse(String description) {
}
def updated() {
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
response(refresh())
}
@@ -163,6 +168,14 @@ def poll() {
], 1000)
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
log.debug "ping() called"
refresh()
}
def refresh() {
delayBetween([
zwave.switchMultilevelV1.switchMultilevelGet().format(),

View File

@@ -1,42 +0,0 @@
# Z-wave Siren
Cloud Execution
Works with:
* [FortrezZ Siren Strobe Alarm](https://www.smartthings.com/works-with-smartthings/other/fortrezz-water-valve)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Troubleshooting](#troubleshooting)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Alarm** - allows for interacting with devices that serve as alarms
* **Battery** - defines device uses a battery
* **Health Check** - indicates ability to get device health notifications
* **Polling** - represents that poll() can be implemented for the device
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - detects sensor events
* **Switch** - can detect state (possible values: on/off)
## Device Health
FortrezZ Siren Strobe Alarm is polled by the hub.
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
* __32min__ checkInterval
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [FortrezZ Siren Strobe Alarm Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202294760-FortrezZ-Siren-Strobe-Alarm)

View File

@@ -20,7 +20,6 @@ metadata {
capability "Actuator"
capability "Alarm"
capability "Battery"
capability "Health Check"
capability "Polling"
capability "Refresh"
capability "Sensor"
@@ -28,7 +27,6 @@ metadata {
fingerprint inClusters: "0x20,0x25,0x86,0x80,0x85,0x72,0x71"
fingerprint mfr:"0084", prod:"0313", model:"010B", deviceJoinName: "FortrezZ Siren Strobe Alarm"
}
simulator {
@@ -60,11 +58,6 @@ metadata {
}
}
def updated(){
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
def createEvents(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def map = [ name: "battery", unit: "%" ]
if (cmd.batteryLevel == 0xFF) {
@@ -126,13 +119,6 @@ def both() {
on()
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
refresh()
}
def refresh() {
log.debug "sending battery refresh command"
zwave.batteryV1.batteryGet().format()

View File

@@ -511,6 +511,10 @@ def pollResponse(response, data) {
if (ResponseValues) {
def map = [:]
ResponseValues.hubs.each {
// Device-Watch relies on the Logitech Harmony Cloud to get the Device state.
def isAlive = it.value.status
def d = getChildDevice("harmony-${it.key}")
d?.sendEvent(name: "DeviceWatch-DeviceStatus", value: isAlive!=504? "online":"offline", displayed: false, isStateChange: true)
if (it.value.message == "OK") {
map["${it.key}"] = "${it.value.response.data.currentAvActivity},${it.value.response.data.activityStatus}"
def hub = getChildDevice("harmony-${it.key}")