Compare commits

...

19 Commits

Author SHA1 Message Date
Vinay Rao
0b81793b0f Merge pull request #2081 from SmartThingsCommunity/staging
Rolling down staging to master
2017-06-09 13:03:54 -07:00
Vinay Rao
16f41bddae Merge pull request #2080 from workingmonk/bug/mark_files_deprecated
SLC-82 Marking old connect apps and device types as deprecated
2017-06-09 13:01:45 -07:00
Vinay Rao
117adea586 SLC-82 Marking old connect apps and device types as deprecated 2017-06-09 11:44:06 -07:00
Vinay Rao
783538e36d Merge pull request #2070 from dkirker/ICP-1097
ICP-1097 Fix Sengled Classic default level on pairing
2017-06-08 16:28:50 -07:00
Vinay Rao
320c8918f8 Merge pull request #2075 from lymanepp/master
MSA-2076: Fix debug message
2017-06-07 15:32:43 -07:00
Lyman Epp
0f3656cd12 Fix debug message 2017-06-07 12:22:33 -05:00
Vinay Rao
6110aaa0fa Merge pull request #2074 from SmartThingsCommunity/master
Rolling up master to staging
2017-06-06 12:01:26 -07:00
Vinay Rao
c391ce4b43 Merge pull request #2073 from SmartThingsCommunity/staging
Rolling down staging to master
2017-06-06 11:55:16 -07:00
Vinay Rao
073bac8dac Merge pull request #2069 from larsfinander/DVCSMP-2688_Remove_sending_turningOn_Off_events_staging
DVCSMP-2688 Remove sending turningOn/Off events
2017-06-06 11:50:59 -07:00
Vinay Rao
3c83bfb53b Merge pull request #2071 from SmartThingsCommunity/production
Rolling down production to staging
2017-06-06 11:34:24 -07:00
Donald Kirker
6325101f52 ICP-1097 Fix Sengled Classic default level on pairing
Code brought oever from @varzac commit 8bcbe7b924
Original commit message:

> Fix sengled use of FF for max level
> This works around the fact that sengled element touches can get back
> into a state of reporting an invalid value (of FF) if the physical
> button on the bulb is used to cycle back to the 100% state.  Here we
> interpret FF as FE for sengled and then issue a move to level command to
> put it in a state where it will report FE until the level is changed
> again.
>
> This resolves: https://smartthings.atlassian.net/browse/DVCSMP-2597

While the Classic does not have a physical button, since it does represent 100% as FF we want to always catch this.
2017-06-06 03:29:41 -07:00
Lars Finander
945a972082 DVCSMP-2688 Remove sending turningOn/Off events
-Removed createSwitchEvent()
2017-06-05 16:50:03 -06:00
Tom Manley
b65acdb91f Merge pull request #2060 from varzac/aeon-multisensor-gen5
[DVCSMP-2680] Correctly configure Aeon Multisensor Gen5
2017-06-02 12:02:59 -05:00
Vinay Rao
4067e6e7e2 Merge pull request #2058 from juano2310/jumping_fix
ICP-1124 - Sylvania SMART BR30 RGBW ' s color ticker moving randomly
2017-06-01 17:40:42 -07:00
Zach Varberg
4c6d1eddb2 Correctly configure Aeon Multisensor Gen5
Previously this device had been changed to use configureAfterSecure to
work around the secure inclusion for Z-Wave.  However, support was added
hub side for handling this so it needed to be changed back to using the
normal configure process.

This resolves: https://smartthings.atlassian.net/browse/DVCSMP-2680
2017-06-01 08:28:12 -05:00
Vinay Rao
10d2097ebe Merge pull request #2065 from bflorian/MSA-1951-1-production-fingerprint
MSA-1951 added second Inovelli fingerprint
2017-05-31 17:35:00 -07:00
Bob Florian
d3728d95b2 MSA-1951 added second Inovelli fingerprint 2017-05-31 16:45:55 -07:00
Vinay Rao
b645872d8f Merge pull request #2063 from SmartThingsCommunity/staging
Rolling up staging to production
2017-05-31 13:42:12 -07:00
juano2310
74a35eeddb ICP-1124 - Sylvania SMART BR30 RGBW ' s color ticker moving randomly
state

overwrite: true
2017-05-30 18:18:22 -04:00
17 changed files with 93 additions and 97 deletions

View File

@@ -26,7 +26,9 @@ metadata {
capability "Polling"
capability "Refresh"
capability "Health Check"
fingerprint manufacturer: "015D", prod: "0221", model: "251C"
fingerprint manufacturer: "015D", prod: "0221", model: "251C", deviceJoinName: "Show Home 2-Channel Smart Plug"
fingerprint manufacturer: "0312", prod: "B221", model: "251C", deviceJoinName: "Inovelli 2-Channel Smart Plug"
}
simulator {}
preferences {}

View File

@@ -22,8 +22,6 @@ metadata {
capability "Battery"
capability "Health Check"
command "configureAfterSecure"
fingerprint deviceId: "0x0701", inClusters: "0x5E,0x86,0x72,0x59,0x85,0x73,0x71,0x84,0x80,0x30,0x31,0x70,0x98,0x7A", outClusters:"0x5A"
fingerprint mfr:"0086", prod:"0102", model:"004A", deviceJoinName: "Aeon Labs MultiSensor (Gen 5)"
}
@@ -91,12 +89,12 @@ metadata {
valueTile("battery", "device.battery", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "battery", label:'${currentValue}% battery', unit:""
}
standardTile("configureAfterSecure", "device.configure", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "configure", label:'', action:"configureAfterSecure", icon:"st.secondary.configure"
standardTile("configure", "device.configure", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
state "configure", label:'', action:"configure", icon:"st.secondary.configure"
}
main(["motion", "temperature", "humidity", "illuminance"])
details(["motion", "temperature", "humidity", "illuminance", "battery", "configureAfterSecure"])
details(["motion", "temperature", "humidity", "illuminance", "battery", "configure"])
}
}
@@ -131,8 +129,8 @@ def zwaveEvent(physicalgraph.zwave.commands.wakeupv1.WakeUpNotification cmd)
if (!isConfigured()) {
// we're still in the process of configuring a newly joined device
log.debug("not sending wakeUpNoMoreInformation yet")
result += response(configureAfterSecure())
log.debug("not sending wakeUpNoMoreInformation yet: late configure")
result += response(configure())
} else {
result += response(zwave.wakeUpV1.wakeUpNoMoreInformation())
}
@@ -150,11 +148,6 @@ def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulat
}
}
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityCommandsSupportedReport cmd) {
// log.debug "Received SecurityCommandsSupportedReport"
response(configureAfterSecure())
}
def zwaveEvent(physicalgraph.zwave.commands.batteryv1.BatteryReport cmd) {
def map = [ name: "battery", unit: "%" ]
if (cmd.batteryLevel == 0xFF) {
@@ -226,36 +219,6 @@ def zwaveEvent(physicalgraph.zwave.Command cmd) {
createEvent(descriptionText: cmd.toString(), isStateChange: false)
}
def configureAfterSecure() {
// log.debug "configureAfterSecure()"
def request = [
// send temperature, humidity, and illuminance every 8 minutes
zwave.configurationV1.configurationSet(parameterNumber: 101, size: 4, scaledConfigurationValue: 128|64|32),
zwave.configurationV1.configurationSet(parameterNumber: 111, size: 4, scaledConfigurationValue: 8*60),
// send battery every 20 hours
zwave.configurationV1.configurationSet(parameterNumber: 102, size: 4, scaledConfigurationValue: 1),
zwave.configurationV1.configurationSet(parameterNumber: 112, size: 4, scaledConfigurationValue: 20*60*60),
// send no-motion report 60 seconds after motion stops
zwave.configurationV1.configurationSet(parameterNumber: 3, size: 2, scaledConfigurationValue: 60),
// send binary sensor report instead of basic set for motion
zwave.configurationV1.configurationSet(parameterNumber: 5, size: 1, scaledConfigurationValue: 2),
// disable notification-style motion events
zwave.notificationV3.notificationSet(notificationType: 7, notificationStatus: 0),
zwave.batteryV1.batteryGet(),
zwave.sensorBinaryV2.sensorBinaryGet(sensorType:0x0C)
]
setConfigured()
secureSequence(request) + ["delay 20000", zwave.wakeUpV1.wakeUpNoMoreInformation().format()]
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
@@ -265,7 +228,36 @@ def ping() {
def configure() {
// log.debug "configure()"
//["delay 30000"] + secure(zwave.securityV1.securityCommandsSupportedGet())
def request = []
// send temperature, humidity, and illuminance every 8 minutes
request << zwave.configurationV1.configurationSet(parameterNumber: 101, size: 4, scaledConfigurationValue: 128|64|32)
request << zwave.configurationV1.configurationSet(parameterNumber: 111, size: 4, scaledConfigurationValue: 8*60)
// send battery every 20 hours
request << zwave.configurationV1.configurationSet(parameterNumber: 102, size: 4, scaledConfigurationValue: 1)
request << zwave.configurationV1.configurationSet(parameterNumber: 112, size: 4, scaledConfigurationValue: 20*60*60)
// send no-motion report 60 seconds after motion stops
request << zwave.configurationV1.configurationSet(parameterNumber: 3, size: 2, scaledConfigurationValue: 60)
// send binary sensor report instead of basic set for motion
request << zwave.configurationV1.configurationSet(parameterNumber: 5, size: 1, scaledConfigurationValue: 2)
// Turn on the Multisensor Gen5 PIR sensor
request << zwave.configurationV1.configurationSet(parameterNumber: 4, size: 1, scaledConfigurationValue: 1)
// disable notification-style motion events
request << zwave.notificationV3.notificationSet(notificationType: 7, notificationStatus: 0)
request << zwave.batteryV1.batteryGet()
request << zwave.sensorBinaryV2.sensorBinaryGet(sensorType: 0x0C) //motion
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x01) //temperature
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x03) //illuminance
request << zwave.sensorMultilevelV5.sensorMultilevelGet(sensorType: 0x05) //humidity
setConfigured()
secureSequence(request) + ["delay 20000", zwave.wakeUpV1.wakeUpNoMoreInformation().format()]
}
private setConfigured() {

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Bose SoundTouch
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Bloom
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Bridge
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Bulb
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Lux Bulb
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue White Ambiance Bulb
*

View File

@@ -49,6 +49,6 @@ def arrived() {
def departed() {
log.trace "Executing 'arrived'"
log.trace "Executing 'departed'"
sendEvent(name: "presence", value: "not present")
}

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Copyright 2015 SmartThings
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Copyright 2015 SmartThings
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Copyright 2015 SmartThings
*

View File

@@ -66,22 +66,29 @@ def parse(String description) {
else {
sendEvent(event)
}
}
else {
def cluster = zigbee.parse(description)
if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07) {
if (cluster.data[0] == 0x00) {
} else {
def descMap = zigbee.parseDescriptionAsMap(description)
if (descMap && descMap.clusterInt == 0x0006 && descMap.commandInt == 0x07) {
if (descMap.data[0] == "00") {
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
else {
} else {
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
}
}
else {
} else if (device.getDataValue("manufacturer") == "sengled" && descMap && descMap.clusterInt == 0x0008 && descMap.attrInt == 0x0000) {
// This is being done because the sengled element touch/classic incorrectly uses the value 0xFF for the max level.
// Per the ZCL spec for the UINT8 data type 0xFF is an invalid value, and 0xFE should be the max. Here we
// manually handle the invalid attribute value since it will be ignored by getEvent as an invalid value.
// We also set the level of the bulb to 0xFE so future level reports will be 0xFE until it is changed by
// something else.
if (descMap.value.toUpperCase() == "FF") {
descMap.value = "FE"
}
sendHubCommand(zigbee.command(zigbee.LEVEL_CONTROL_CLUSTER, 0x00, "FE0000").collect { new physicalgraph.device.HubAction(it) }, 0)
sendEvent(zigbee.getEventFromAttrData(descMap.clusterInt, descMap.attrInt, descMap.encoding, descMap.value))
} else {
log.warn "DID NOT PARSE MESSAGE for description : $description"
log.debug "${cluster}"
log.debug "${descMap}"
}
}
}

View File

@@ -103,12 +103,12 @@ def parse(String description) {
if (zigbeeMap?.clusterInt == COLOR_CONTROL_CLUSTER) {
if(zigbeeMap.attrInt == ATTRIBUTE_HUE){ //Hue Attribute
def hueValue = Math.round(zigbee.convertHexToInt(zigbeeMap.value) / 0xfe * 100)
sendEvent(name: "hue", value: hueValue, descriptionText: "Color has changed")
state.hueValue = Math.round(zigbee.convertHexToInt(zigbeeMap.value) / 0xfe * 100)
runIn(5, updateColor, [overwrite: true])
}
else if(zigbeeMap.attrInt == ATTRIBUTE_SATURATION){ //Saturation Attribute
def saturationValue = Math.round(zigbee.convertHexToInt(zigbeeMap.value) / 0xfe * 100)
sendEvent(name: "saturation", value: saturationValue, descriptionText: "Color has changed", displayed: false)
state.saturationValue = Math.round(zigbee.convertHexToInt(zigbeeMap.value) / 0xfe * 100)
runIn(5, updateColor, [overwrite: true])
}
}
else if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07) {
@@ -127,6 +127,11 @@ def parse(String description) {
}
}
def updateColor() {
sendEvent(name: "hue", value: state.hueValue, descriptionText: "Color has changed")
sendEvent(name: "saturation", value: state.saturationValue, descriptionText: "Color has changed", displayed: false)
}
def on() {
zigbee.on()
}
@@ -204,9 +209,9 @@ def setColor(value){
log.trace "setColor($value)"
zigbee.on() +
zigbee.command(COLOR_CONTROL_CLUSTER, MOVE_TO_HUE_AND_SATURATION_COMMAND,
getScaledHue(value.hue), getScaledSaturation(value.saturation), "0000") +
zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) +
zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION)
getScaledHue(value.hue), getScaledSaturation(value.saturation), "0000") +
zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION) +
zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE)
}
def setHue(value) {

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Bose SoundTouch (Connect)
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Service Manager
*
@@ -1083,7 +1085,6 @@ def on(childDevice) {
log.debug "Executing 'on'"
def id = getId(childDevice)
updateInProgress()
createSwitchEvent(childDevice, "on")
put("lights/$id/state", [on: true])
return "Bulb is turning On"
}
@@ -1092,7 +1093,6 @@ def off(childDevice) {
log.debug "Executing 'off'"
def id = getId(childDevice)
updateInProgress()
createSwitchEvent(childDevice, "off")
put("lights/$id/state", [on: false])
return "Bulb is turning Off"
}
@@ -1108,8 +1108,6 @@ def setLevel(childDevice, percent) {
else
level = Math.min(Math.round(percent * 254 / 100), 254)
createSwitchEvent(childDevice, level > 0, percent)
// For Zigbee lights, if level is set to 0 ST just turns them off without changing level
// that means that the light will still be on when on is called next time
// Lets emulate that here
@@ -1128,7 +1126,6 @@ def setSaturation(childDevice, percent) {
// 0 - 254
def level = Math.min(Math.round(percent * 254 / 100), 254)
// TODO should this be done by app only or should we default to on?
createSwitchEvent(childDevice, "on")
put("lights/$id/state", [sat: level, on: true])
return "Setting saturation to $percent"
}
@@ -1140,7 +1137,6 @@ def setHue(childDevice, percent) {
// 0 - 65535
def level = Math.min(Math.round(percent * 65535 / 100), 65535)
// TODO should this be done by app only or should we default to on?
createSwitchEvent(childDevice, "on")
put("lights/$id/state", [hue: level, on: true])
return "Setting hue to $percent"
}
@@ -1151,7 +1147,6 @@ def setColorTemperature(childDevice, huesettings) {
updateInProgress()
// 153 (6500K) to 500 (2000K)
def ct = hueSettings == 6500 ? 153 : Math.round(1000000 / huesettings)
createSwitchEvent(childDevice, "on")
put("lights/$id/state", [ct: ct, on: true])
return "Setting color temperature to $ct"
}
@@ -1210,7 +1205,6 @@ def setColor(childDevice, huesettings) {
if (huesettings.switch == "off")
value.on = false
createSwitchEvent(childDevice, value.on ? "on" : "off")
put("lights/$id/state", value)
return "Setting color to $value"
}
@@ -1322,32 +1316,6 @@ private List getRealHubFirmwareVersions() {
return location.hubs*.firmwareVersionString.findAll { it }
}
/**
* Sends appropriate turningOn/turningOff state events depending on switch or level changes.
*
* @param childDevice device to send event for
* @param setSwitch The new switch state, "on" or "off"
* @param setLevel Optional, switchLevel between 0-100, used if you set level to 0 for example since
* that should generate "off" instead of level change
*/
private void createSwitchEvent(childDevice, setSwitch, setLevel = null) {
if (setLevel == null) {
setLevel = childDevice.device?.currentValue("level")
}
// Create on, off, turningOn or turningOff event as necessary
def currentState = childDevice.device?.currentValue("switch")
if ((currentState == "off" || currentState == "turningOff")) {
if (setSwitch == "on" || setLevel > 0) {
childDevice.sendEvent(name: "switch", value: "turningOn", displayed: false)
}
} else if ((currentState == "on" || currentState == "turningOn")) {
if (setSwitch == "off" || setLevel == 0) {
childDevice.sendEvent(name: "switch", value: "turningOff", displayed: false)
}
}
}
/**
* Return the supported color range for different Hue lights. If model is not specified
* it defaults to the smallest Gamut (B) to ensure that colors set on a mix of devices

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Copyright 2015 SmartThings
*