mirror of
https://github.com/mtan93/SmartThingsPublic.git
synced 2026-03-09 13:21:53 +00:00
Compare commits
22 Commits
PROD_2016.
...
MSA-1542-1
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
a9aee8fd96 | ||
|
|
5c015cf678 | ||
|
|
cf1a46e309 | ||
|
|
1ff77dc608 | ||
|
|
afbec02217 | ||
|
|
434a72bd13 | ||
|
|
3fba7c9422 | ||
|
|
b63d4a9156 | ||
|
|
6eb29ad019 | ||
|
|
711cdc3ebf | ||
|
|
f58a1ef589 | ||
|
|
db5237ca33 | ||
|
|
7791c68a8a | ||
|
|
db4140ffd6 | ||
|
|
723ef7e7e6 | ||
|
|
84c72de640 | ||
|
|
570454e6c3 | ||
|
|
a5d95fb025 | ||
|
|
50696902cf | ||
|
|
409658e899 | ||
|
|
1068a553f5 | ||
|
|
bbdf9ff02a |
2
devicetypes/smartthings/dimmer-switch.src/.st-ignore
Normal file
2
devicetypes/smartthings/dimmer-switch.src/.st-ignore
Normal file
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
45
devicetypes/smartthings/dimmer-switch.src/README.md
Normal file
45
devicetypes/smartthings/dimmer-switch.src/README.md
Normal file
@@ -0,0 +1,45 @@
|
||||
# Z-wave Dimmer Switch
|
||||
|
||||
|
||||
|
||||
Works with:
|
||||
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (GE 12724)](http://products.z-wavealliance.org/products/1197)
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (Toggle) (GE 12729)](http://products.z-wavealliance.org/products/1201)
|
||||
* [GE Z-Wave Plug-in Smart Dimmer (GE 12718)](http://products.z-wavealliance.org/products/1191)
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
* [Troubleshooting](#Troubleshooting)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Switch Level** - it's defined to accept two parameters, the level and the rate of dimming
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Indicator** - gives you the ability to set the indicator LED light on a Z-Wave switch
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Polling** - represents that poll() can be implemented for the device
|
||||
* **Refresh** - _refresh()_ command for status updates
|
||||
* **Sensor** - detects sensor events
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
|
||||
## Device Health
|
||||
|
||||
Z-Wave Smart Dimmers (In-Wall, In-Wall(Toggle), Plug-In) are polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Check-in interval = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [General Z-Wave Dimmer/Switch Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200955890-Troubleshooting-GE-in-wall-switch-or-dimmer-won-t-respond-to-commands-or-automations-Z-Wave-)
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (GE 12724) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200902600-GE-In-Wall-Paddle-Dimmer-Switch-GE-12724-Z-Wave-)
|
||||
* [GE Z-Wave In-Wall Smart Dimmer (Toggle) (GE 12729) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/207568463-GE-In-Wall-Smart-Toggle-Dimmer-GE-12729-Z-Wave-)
|
||||
* [GE Z-Wave Plug-in Smart Dimmer (GE 12718) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202088474-GE-Plug-In-Smart-Dimmer-GE-12718-Z-Wave-)
|
||||
@@ -20,6 +20,7 @@ metadata {
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Health Check"
|
||||
|
||||
fingerprint mfr:"0063", prod:"4457", deviceJoinName: "Z-Wave Wall Dimmer"
|
||||
fingerprint mfr:"0063", prod:"4944", deviceJoinName: "Z-Wave Wall Dimmer"
|
||||
@@ -82,6 +83,8 @@ metadata {
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
switch (ledIndicator) {
|
||||
case "on":
|
||||
indicatorWhenOn()
|
||||
@@ -215,6 +218,13 @@ def poll() {
|
||||
zwave.switchMultilevelV1.switchMultilevelGet().format()
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
log.debug "refresh() is called"
|
||||
def commands = []
|
||||
|
||||
@@ -21,9 +21,6 @@ metadata {
|
||||
attribute "colorName", "string"
|
||||
|
||||
command "setAdjustedColor"
|
||||
|
||||
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "Gardenspot RGB"
|
||||
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY Gardenspot RGB"
|
||||
}
|
||||
|
||||
// simulator metadata
|
||||
|
||||
@@ -133,7 +133,7 @@ def refresh() {
|
||||
}
|
||||
|
||||
def configure() {
|
||||
onOffConfig() + levelConfig() + powerConfig() + refresh()
|
||||
refresh() + onOffConfig() + levelConfig() + powerConfig()
|
||||
}
|
||||
|
||||
|
||||
|
||||
@@ -146,7 +146,7 @@ def configure() {
|
||||
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
zigbee.onOffConfig(0, 300) + powerConfig() + refresh()
|
||||
refresh() + zigbee.onOffConfig(0, 300) + powerConfig()
|
||||
}
|
||||
|
||||
//power config for devices with min reporting interval as 1 seconds and reporting interval if no activity as 10min (600s)
|
||||
|
||||
@@ -308,16 +308,9 @@ def configure() {
|
||||
// enrolls with default periodic reporting until newer 5 min interval is confirmed
|
||||
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting, IAS CIE, and Bindings."
|
||||
def enrollCmds = [
|
||||
"zcl global write 0x500 0x10 0xf0 {${zigbeeEui}}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 1", "delay 500",
|
||||
]
|
||||
|
||||
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
// battery minReport 30 seconds, maxReportTime 6 hrs by default
|
||||
return enrollCmds + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) + refresh() // send refresh cmds as part of config
|
||||
return refresh() + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) // send refresh cmds as part of config
|
||||
}
|
||||
|
||||
def enrollResponse() {
|
||||
|
||||
@@ -323,16 +323,9 @@ def configure() {
|
||||
// enrolls with default periodic reporting until newer 5 min interval is confirmed
|
||||
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting, IAS CIE, and Bindings."
|
||||
|
||||
def enrollCmds = [
|
||||
"zcl global write 0x500 0x10 0xf0 {${zigbeeEui}}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
]
|
||||
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
// battery minReport 30 seconds, maxReportTime 6 hrs by default
|
||||
return enrollCmds + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) + refresh() // send refresh cmds as part of config
|
||||
return refresh() + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) // send refresh cmds as part of config
|
||||
}
|
||||
|
||||
def enrollResponse() {
|
||||
|
||||
@@ -255,13 +255,9 @@ def refresh() {
|
||||
}
|
||||
|
||||
def configure() {
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting, IAS CIE, and Bindings."
|
||||
|
||||
def configCmds = [
|
||||
"zcl global write 0x500 0x10 0xf0 {${zigbeeEui}}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
|
||||
"zdo bind 0x${device.deviceNetworkId} ${endpointId} 1 1 {${device.zigbeeId}} {}", "delay 200",
|
||||
"zcl global send-me-a-report 1 0x20 0x20 30 21600 {01}", //checkin time 6 hrs
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
@@ -270,7 +266,7 @@ def configure() {
|
||||
"zcl global send-me-a-report 0x402 0 0x29 30 3600 {6400}",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500"
|
||||
]
|
||||
return configCmds + refresh() // send refresh cmds as part of config
|
||||
return refresh() + configCmds // send refresh cmds as part of config
|
||||
}
|
||||
|
||||
def enrollResponse() {
|
||||
|
||||
@@ -420,15 +420,14 @@ def configure() {
|
||||
|
||||
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
// battery minReport 30 seconds, maxReportTime 6 hrs by default
|
||||
def configCmds = enrollResponse() +
|
||||
zigbee.batteryConfig() +
|
||||
def configCmds = zigbee.batteryConfig() +
|
||||
zigbee.temperatureConfig(30, 300) +
|
||||
zigbee.configureReporting(0xFC02, 0x0010, 0x18, 10, 3600, 0x01, [mfgCode: manufacturerCode]) +
|
||||
zigbee.configureReporting(0xFC02, 0x0012, 0x29, 1, 3600, 0x0001, [mfgCode: manufacturerCode]) +
|
||||
zigbee.configureReporting(0xFC02, 0x0013, 0x29, 1, 3600, 0x0001, [mfgCode: manufacturerCode]) +
|
||||
zigbee.configureReporting(0xFC02, 0x0014, 0x29, 1, 3600, 0x0001, [mfgCode: manufacturerCode])
|
||||
|
||||
return configCmds + refresh()
|
||||
return refresh() + configCmds
|
||||
}
|
||||
|
||||
private getEndpointId() {
|
||||
|
||||
@@ -277,12 +277,8 @@ def getTemperature(value) {
|
||||
def configure() {
|
||||
sendEvent(name: "checkInterval", value: 7200, displayed: false)
|
||||
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting, IAS CIE, and Bindings."
|
||||
def configCmds = [
|
||||
"zcl global write 0x500 0x10 0xf0 {${zigbeeEui}}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
|
||||
"zdo bind 0x${device.deviceNetworkId} ${endpointId} 1 1 {${device.zigbeeId}} {}", "delay 200",
|
||||
"zcl global send-me-a-report 1 0x20 0x20 30 21600 {01}", //checkin time 6 hrs
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500",
|
||||
@@ -295,7 +291,7 @@ def configure() {
|
||||
"zcl global send-me-a-report 0xFC02 2 0x18 30 3600 {01}",
|
||||
"send 0x${device.deviceNetworkId} 1 ${endpointId}", "delay 500"
|
||||
]
|
||||
return configCmds + refresh() // send refresh cmds as part of config
|
||||
return refresh() + configCmds // send refresh cmds as part of config
|
||||
}
|
||||
|
||||
def enrollResponse() {
|
||||
|
||||
@@ -270,16 +270,11 @@ def configure() {
|
||||
// enrolls with default periodic reporting until newer 5 min interval is confirmed
|
||||
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
String zigbeeEui = swapEndianHex(device.hub.zigbeeEui)
|
||||
log.debug "Configuring Reporting, IAS CIE, and Bindings."
|
||||
def enrollCmds = [
|
||||
"zcl global write 0x500 0x10 0xf0 {${zigbeeEui}}", "delay 200",
|
||||
"send 0x${device.deviceNetworkId} 1 1", "delay 500",
|
||||
]
|
||||
|
||||
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
// battery minReport 30 seconds, maxReportTime 6 hrs by default
|
||||
return enrollCmds + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) + refresh() // send refresh cmds as part of config
|
||||
return refresh() + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) // send refresh cmds as part of config
|
||||
}
|
||||
|
||||
def enrollResponse() {
|
||||
|
||||
@@ -250,11 +250,7 @@ private Map getTemperatureResult(value) {
|
||||
|
||||
private Map getHumidityResult(value) {
|
||||
log.debug 'Humidity'
|
||||
return [
|
||||
name: 'humidity',
|
||||
value: value,
|
||||
unit: '%'
|
||||
]
|
||||
return value ? [name: 'humidity', value: value, unit: '%'] : [:]
|
||||
}
|
||||
|
||||
/**
|
||||
@@ -267,15 +263,10 @@ def ping() {
|
||||
def refresh()
|
||||
{
|
||||
log.debug "refresh temperature, humidity, and battery"
|
||||
[
|
||||
|
||||
"zcl mfg-code 0xC2DF", "delay 1000",
|
||||
"zcl global read 0xFC45 0", "delay 1000",
|
||||
"send 0x${device.deviceNetworkId} 1 1", "delay 1000",
|
||||
"st rattr 0x${device.deviceNetworkId} 1 0x402 0", "delay 200",
|
||||
"st rattr 0x${device.deviceNetworkId} 1 1 0x20"
|
||||
|
||||
]
|
||||
return zigbee.readAttribute(0xFC45, 0x0000, ["mfgCode": 0xC2DF]) + // Original firmware
|
||||
zigbee.readAttribute(0xFC45, 0x0000, ["mfgCode": 0x104E]) + // New firmware
|
||||
zigbee.readAttribute(0x0402, 0x0000) +
|
||||
zigbee.readAttribute(0x0001, 0x0020)
|
||||
}
|
||||
|
||||
def configure() {
|
||||
@@ -292,7 +283,7 @@ def configure() {
|
||||
|
||||
// temperature minReportTime 30 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
// battery minReport 30 seconds, maxReportTime 6 hrs by default
|
||||
return humidityConfigCmds + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) + refresh() // send refresh cmds as part of config
|
||||
return refresh() + humidityConfigCmds + zigbee.batteryConfig() + zigbee.temperatureConfig(30, 300) // send refresh cmds as part of config
|
||||
}
|
||||
|
||||
private hex(value) {
|
||||
|
||||
@@ -89,14 +89,8 @@ def parse(String description) {
|
||||
}
|
||||
|
||||
private Map parseIasButtonMessage(String description) {
|
||||
int zoneInt = Integer.parseInt((description - "zone status 0x"), 16)
|
||||
if (zoneInt & 0x02) {
|
||||
resultMap = getButtonResult('press')
|
||||
} else {
|
||||
resultMap = getButtonResult('release')
|
||||
}
|
||||
|
||||
return resultMap
|
||||
def zs = zigbee.parseZoneStatus(description)
|
||||
return zs.isAlarm2Set() ? getButtonResult("press") : getButtonResult("release")
|
||||
}
|
||||
|
||||
private Map getBatteryResult(rawValue) {
|
||||
|
||||
@@ -93,5 +93,5 @@ def refresh() {
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.simpleMeteringPowerConfig() + zigbee.electricMeasurementPowerConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.simpleMeteringPowerRefresh() + zigbee.electricMeasurementPowerRefresh()
|
||||
refresh()
|
||||
}
|
||||
|
||||
@@ -107,5 +107,5 @@ def configure() {
|
||||
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh()
|
||||
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.onOffConfig(0, 300) + zigbee.levelConfig()
|
||||
}
|
||||
|
||||
@@ -90,7 +90,7 @@ def configure() {
|
||||
zigbee.configureReporting(CLUSTER_POWER, POWER_ATTR_BATTERY_PERCENTAGE_REMAINING,
|
||||
TYPE_U8, 600, 21600, 0x01)
|
||||
log.info "configure() --- cmds: $cmds"
|
||||
return cmds + refresh() // send refresh cmds as part of config
|
||||
return refresh() + cmds // send refresh cmds as part of config
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
|
||||
@@ -0,0 +1,154 @@
|
||||
/**
|
||||
* Copyright 2016 SmartThings
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
|
||||
* in compliance with the License. You may obtain a copy of the License at:
|
||||
*
|
||||
* http://www.apache.org/licenses/LICENSE-2.0
|
||||
*
|
||||
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
|
||||
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
* Author: SmartThings
|
||||
* Date: 2016-01-19
|
||||
*
|
||||
* This DTH should serve as the generic DTH to handle RGB ZigBee HA devices (For color bulbs with no color temperature)
|
||||
*/
|
||||
|
||||
metadata {
|
||||
definition (name: "ZigBee RGB Bulb", namespace: "smartthings", author: "SmartThings") {
|
||||
|
||||
capability "Actuator"
|
||||
capability "Color Control"
|
||||
capability "Configuration"
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Switch"
|
||||
capability "Switch Level"
|
||||
capability "Health Check"
|
||||
|
||||
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "Gardenspot RGB", deviceJoinName: "OSRAM LIGHTIFY Gardenspot mini RGB"
|
||||
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY Gardenspot RGB", deviceJoinName: "OSRAM LIGHTIFY Gardenspot mini RGB"
|
||||
}
|
||||
|
||||
// UI tile definitions
|
||||
tiles(scale: 2) {
|
||||
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){
|
||||
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
|
||||
attributeState "on", label:'${name}', action:"switch.off", icon:"st.lights.philips.hue-single", backgroundColor:"#79b821", nextState:"turningOff"
|
||||
attributeState "off", label:'${name}', action:"switch.on", icon:"st.lights.philips.hue-single", backgroundColor:"#ffffff", nextState:"turningOn"
|
||||
attributeState "turningOn", label:'${name}', action:"switch.off", icon:"st.lights.philips.hue-single", backgroundColor:"#79b821", nextState:"turningOff"
|
||||
attributeState "turningOff", label:'${name}', action:"switch.on", icon:"st.lights.philips.hue-single", backgroundColor:"#ffffff", nextState:"turningOn"
|
||||
}
|
||||
tileAttribute ("device.level", key: "SLIDER_CONTROL") {
|
||||
attributeState "level", action:"switch level.setLevel"
|
||||
}
|
||||
tileAttribute ("device.color", key: "COLOR_CONTROL") {
|
||||
attributeState "color", action:"color control.setColor"
|
||||
}
|
||||
}
|
||||
standardTile("refresh", "device.refresh", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
|
||||
state "default", label:"", action:"refresh.refresh", icon:"st.secondary.refresh"
|
||||
}
|
||||
|
||||
main(["switch"])
|
||||
details(["switch", "refresh"])
|
||||
}
|
||||
}
|
||||
|
||||
//Globals
|
||||
private getATTRIBUTE_HUE() { 0x0000 }
|
||||
private getATTRIBUTE_SATURATION() { 0x0001 }
|
||||
private getHUE_COMMAND() { 0x00 }
|
||||
private getSATURATION_COMMAND() { 0x03 }
|
||||
private getCOLOR_CONTROL_CLUSTER() { 0x0300 }
|
||||
|
||||
// Parse incoming device messages to generate events
|
||||
def parse(String description) {
|
||||
log.debug "description is $description"
|
||||
|
||||
def event = zigbee.getEvent(description)
|
||||
if (event) {
|
||||
log.debug event
|
||||
if (event.name=="level" && event.value==0) {}
|
||||
else {
|
||||
sendEvent(event)
|
||||
}
|
||||
}
|
||||
else {
|
||||
def zigbeeMap = zigbee.parseDescriptionAsMap(description)
|
||||
def cluster = zigbee.parse(description)
|
||||
|
||||
if (zigbeeMap?.clusterInt == COLOR_CONTROL_CLUSTER) {
|
||||
if(zigbeeMap.attrInt == ATTRIBUTE_HUE){ //Hue Attribute
|
||||
def hueValue = Math.round(zigbee.convertHexToInt(zigbeeMap.value) / 255 * 100)
|
||||
sendEvent(name: "hue", value: hueValue, descriptionText: "Color has changed")
|
||||
}
|
||||
else if(zigbeeMap.attrInt == ATTRIBUTE_SATURATION){ //Saturation Attribute
|
||||
def saturationValue = Math.round(zigbee.convertHexToInt(zigbeeMap.value) / 255 * 100)
|
||||
sendEvent(name: "saturation", value: saturationValue, descriptionText: "Color has changed", displayed: false)
|
||||
}
|
||||
}
|
||||
else if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07) {
|
||||
if (cluster.data[0] == 0x00){
|
||||
log.debug "ON/OFF REPORTING CONFIG RESPONSE: $cluster"
|
||||
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
else {
|
||||
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
|
||||
}
|
||||
}
|
||||
else {
|
||||
log.info "DID NOT PARSE MESSAGE for description : $description"
|
||||
log.debug zigbeeMap
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
def on() {
|
||||
zigbee.on()
|
||||
}
|
||||
|
||||
def off() {
|
||||
zigbee.off()
|
||||
}
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
return zigbee.onOffRefresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION) + zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE, 0x20, 1, 3600, 0x01) + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION, 0x20, 1, 3600, 0x01)
|
||||
}
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
|
||||
// enrolls with default periodic reporting until newer 5 min interval is confirmed
|
||||
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE, 0x20, 1, 3600, 0x01) + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION, 0x20, 1, 3600, 0x01) + zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION)
|
||||
}
|
||||
|
||||
def setLevel(value) {
|
||||
zigbee.setLevel(value)
|
||||
}
|
||||
|
||||
def setColor(value){
|
||||
log.trace "setColor($value)"
|
||||
zigbee.on() + setHue(value.hue) + "delay 500" + setSaturation(value.saturation)
|
||||
}
|
||||
|
||||
def setHue(value) {
|
||||
def scaledHueValue = zigbee.convertToHexString(Math.round(value * 0xfe / 100.0), 2)
|
||||
zigbee.command(COLOR_CONTROL_CLUSTER, HUE_COMMAND, scaledHueValue, "00", "0500") //payload-> hue value, direction (00-> shortest distance), transition time (1/10th second) (0500 in U16 reads 5)
|
||||
}
|
||||
|
||||
def setSaturation(value) {
|
||||
def scaledSatValue = zigbee.convertToHexString(Math.round(value * 0xfe / 100.0), 2)
|
||||
zigbee.command(COLOR_CONTROL_CLUSTER, SATURATION_COMMAND, scaledSatValue, "0500") + "delay 1000" + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION)
|
||||
}
|
||||
@@ -138,7 +138,7 @@ def ping() {
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
zigbee.onOffRefresh() + zigbee.readAttribute(0x0008, 0x00) + zigbee.readAttribute(0x0300, 0x00) + zigbee.readAttribute(0x0300, ATTRIBUTE_COLOR_TEMPERATURE) + zigbee.readAttribute(0x0300, ATTRIBUTE_HUE) + zigbee.readAttribute(0x0300, ATTRIBUTE_SATURATION) + zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.colorTemperatureConfig() + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE, 0x20, 1, 3600, 0x01) + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION, 0x20, 1, 3600, 0x01)
|
||||
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_COLOR_TEMPERATURE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION) + zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.colorTemperatureConfig() + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE, 0x20, 1, 3600, 0x01) + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION, 0x20, 1, 3600, 0x01)
|
||||
}
|
||||
|
||||
def configure() {
|
||||
@@ -148,7 +148,7 @@ def configure() {
|
||||
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.colorTemperatureConfig() + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE, 0x20, 1, 3600, 0x01) + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION, 0x20, 1, 3600, 0x01) + zigbee.readAttribute(0x0006, 0x00) + zigbee.readAttribute(0x0008, 0x00) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, 0x00) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_COLOR_TEMPERATURE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION)
|
||||
refresh()
|
||||
}
|
||||
|
||||
def setColorTemperature(value) {
|
||||
|
||||
@@ -82,5 +82,5 @@ def refresh() {
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
zigbee.onOffConfig() + zigbee.simpleMeteringPowerConfig() + zigbee.electricMeasurementPowerConfig() + zigbee.onOffRefresh() + zigbee.simpleMeteringPowerRefresh() + zigbee.electricMeasurementPowerRefresh()
|
||||
refresh()
|
||||
}
|
||||
|
||||
@@ -78,5 +78,5 @@ def refresh() {
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
zigbee.onOffConfig() + zigbee.onOffRefresh()
|
||||
zigbee.onOffRefresh() + zigbee.onOffConfig()
|
||||
}
|
||||
|
||||
@@ -134,10 +134,5 @@ def refresh() {
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
zigbee.onOffConfig() +
|
||||
zigbee.configureReporting(CLUSTER_POWER, POWER_ATTR_BATTERY_PERCENTAGE_REMAINING, TYPE_U8, 600, 21600, 1) +
|
||||
zigbee.configureReporting(CLUSTER_BASIC, BASIC_ATTR_POWER_SOURCE, TYPE_ENUM8, 5, 21600, 1) +
|
||||
zigbee.onOffRefresh() +
|
||||
zigbee.readAttribute(CLUSTER_BASIC, BASIC_ATTR_POWER_SOURCE) +
|
||||
zigbee.readAttribute(CLUSTER_POWER, POWER_ATTR_BATTERY_PERCENTAGE_REMAINING)
|
||||
refresh()
|
||||
}
|
||||
|
||||
@@ -131,7 +131,7 @@ def configure() {
|
||||
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
|
||||
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
|
||||
zigbee.onOffConfig(0, 300) + zigbee.levelConfig() + zigbee.colorTemperatureConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh()
|
||||
refresh()
|
||||
}
|
||||
|
||||
def setColorTemperature(value) {
|
||||
|
||||
@@ -11,6 +11,9 @@
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
*/
|
||||
import groovy.transform.Field
|
||||
|
||||
@Field Boolean hasConfiguredHealthCheck = false
|
||||
|
||||
metadata {
|
||||
definition (name: "ZLL Dimmer Bulb", namespace: "smartthings", author: "SmartThings") {
|
||||
@@ -21,6 +24,7 @@ metadata {
|
||||
capability "Refresh"
|
||||
capability "Switch"
|
||||
capability "Switch Level"
|
||||
capability "Health Check"
|
||||
|
||||
//fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0000,0019"
|
||||
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0019"
|
||||
@@ -96,7 +100,38 @@ def poll() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh()
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
return zigbee.levelRefresh()
|
||||
}
|
||||
|
||||
def healthPoll() {
|
||||
log.debug "healthPoll()"
|
||||
def cmds = refresh()
|
||||
cmds.each{ sendHubCommand(new physicalgraph.device.HubAction(it))}
|
||||
}
|
||||
|
||||
def configureHealthCheck() {
|
||||
Integer hcIntervalMinutes = 12
|
||||
if (!hasConfiguredHealthCheck) {
|
||||
log.debug "Configuring Health Check, Reporting"
|
||||
unschedule("healthPoll")
|
||||
runEvery5Minutes("healthPoll")
|
||||
// Device-Watch allows 2 check-in misses from device
|
||||
sendEvent(name: "checkInterval", value: hcIntervalMinutes * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
hasConfiguredHealthCheck = true
|
||||
}
|
||||
}
|
||||
|
||||
def configure() {
|
||||
log.debug "configure()"
|
||||
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh()
|
||||
configureHealthCheck()
|
||||
}
|
||||
|
||||
def updated() {
|
||||
log.debug "updated()"
|
||||
configureHealthCheck()
|
||||
}
|
||||
|
||||
134
devicetypes/smartthings/zll-rgb-bulb.src/zll-rgb-bulb.groovy
Normal file
134
devicetypes/smartthings/zll-rgb-bulb.src/zll-rgb-bulb.groovy
Normal file
@@ -0,0 +1,134 @@
|
||||
/**
|
||||
* Copyright 2016 SmartThings
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
|
||||
* in compliance with the License. You may obtain a copy of the License at:
|
||||
*
|
||||
* http://www.apache.org/licenses/LICENSE-2.0
|
||||
*
|
||||
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
|
||||
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
*/
|
||||
|
||||
metadata {
|
||||
definition (name: "ZLL RGB Bulb", namespace: "smartthings", author: "SmartThings") {
|
||||
|
||||
capability "Actuator"
|
||||
capability "Color Control"
|
||||
capability "Configuration"
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Switch"
|
||||
capability "Switch Level"
|
||||
}
|
||||
|
||||
// UI tile definitions
|
||||
tiles(scale: 2) {
|
||||
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){
|
||||
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
|
||||
attributeState "on", label:'${name}', action:"switch.off", icon:"st.lights.philips.hue-single", backgroundColor:"#79b821", nextState:"turningOff"
|
||||
attributeState "off", label:'${name}', action:"switch.on", icon:"st.lights.philips.hue-single", backgroundColor:"#ffffff", nextState:"turningOn"
|
||||
attributeState "turningOn", label:'${name}', action:"switch.off", icon:"st.lights.philips.hue-single", backgroundColor:"#79b821", nextState:"turningOff"
|
||||
attributeState "turningOff", label:'${name}', action:"switch.on", icon:"st.lights.philips.hue-single", backgroundColor:"#ffffff", nextState:"turningOn"
|
||||
}
|
||||
tileAttribute ("device.level", key: "SLIDER_CONTROL") {
|
||||
attributeState "level", action:"switch level.setLevel"
|
||||
}
|
||||
tileAttribute ("device.color", key: "COLOR_CONTROL") {
|
||||
attributeState "color", action:"color control.setColor"
|
||||
}
|
||||
}
|
||||
standardTile("refresh", "device.refresh", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
|
||||
state "default", label:"", action:"refresh.refresh", icon:"st.secondary.refresh"
|
||||
}
|
||||
|
||||
main(["switch"])
|
||||
details(["switch", "refresh"])
|
||||
}
|
||||
}
|
||||
|
||||
//Globals
|
||||
private getATTRIBUTE_HUE() { 0x0000 }
|
||||
private getATTRIBUTE_SATURATION() { 0x0001 }
|
||||
private getHUE_COMMAND() { 0x00 }
|
||||
private getSATURATION_COMMAND() { 0x03 }
|
||||
private getCOLOR_CONTROL_CLUSTER() { 0x0300 }
|
||||
|
||||
// Parse incoming device messages to generate events
|
||||
def parse(String description) {
|
||||
log.debug "description is $description"
|
||||
|
||||
def finalResult = zigbee.getEvent(description)
|
||||
if (finalResult) {
|
||||
log.debug finalResult
|
||||
sendEvent(finalResult)
|
||||
}
|
||||
else {
|
||||
def zigbeeMap = zigbee.parseDescriptionAsMap(description)
|
||||
log.trace "zigbeeMap : $zigbeeMap"
|
||||
|
||||
if (zigbeeMap?.clusterInt == COLOR_CONTROL_CLUSTER) {
|
||||
if(zigbeeMap.attrInt == ATTRIBUTE_HUE){ //Hue Attribute
|
||||
def hueValue = Math.round(zigbee.convertHexToInt(zigbeeMap.value) / 255 * 360)
|
||||
sendEvent(name: "hue", value: hueValue, displayed:false)
|
||||
}
|
||||
else if(zigbeeMap.attrInt == ATTRIBUTE_SATURATION){ //Saturation Attribute
|
||||
def saturationValue = Math.round(zigbee.convertHexToInt(zigbeeMap.value) / 255 * 100)
|
||||
sendEvent(name: "saturation", value: saturationValue, displayed:false)
|
||||
}
|
||||
}
|
||||
else {
|
||||
log.info "DID NOT PARSE MESSAGE for description : $description"
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
def on() {
|
||||
zigbee.on() + ["delay 1500"] + zigbee.onOffRefresh()
|
||||
}
|
||||
|
||||
def off() {
|
||||
zigbee.off() + ["delay 1500"] + zigbee.onOffRefresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
refreshAttributes() + configureAttributes()
|
||||
}
|
||||
|
||||
def poll() {
|
||||
refreshAttributes()
|
||||
}
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
configureAttributes() + refreshAttributes()
|
||||
}
|
||||
|
||||
def configureAttributes() {
|
||||
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE, 0x20, 1, 3600, 0x01) + zigbee.configureReporting(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION, 0x20, 1, 3600, 0x01)
|
||||
}
|
||||
|
||||
def refreshAttributes() {
|
||||
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION)
|
||||
}
|
||||
|
||||
def setLevel(value) {
|
||||
zigbee.setLevel(value) + ["delay 1500"] + zigbee.levelRefresh() //adding refresh because of ZLL bulb not conforming to send-me-a-report
|
||||
}
|
||||
|
||||
def setColor(value){
|
||||
log.trace "setColor($value)"
|
||||
zigbee.on() + setHue(value.hue) + ["delay 300"] + setSaturation(value.saturation) + ["delay 2000"] + refreshAttributes()
|
||||
}
|
||||
|
||||
def setHue(value) {
|
||||
def scaledHueValue = zigbee.convertToHexString(Math.round(value * 0xfe / 100.0), 2)
|
||||
zigbee.command(COLOR_CONTROL_CLUSTER, HUE_COMMAND, scaledHueValue, "00", "0500") + ["delay 1500"] + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) //payload-> hue value, direction (00-> shortest distance), transition time (1/10th second) (0500 in U16 reads 5)
|
||||
}
|
||||
|
||||
def setSaturation(value) {
|
||||
def scaledSatValue = zigbee.convertToHexString(Math.round(value * 0xfe / 100.0), 2)
|
||||
zigbee.command(COLOR_CONTROL_CLUSTER, SATURATION_COMMAND, scaledSatValue, "0500") + ["delay 1500"] + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION) //payload-> sat value, transition time
|
||||
}
|
||||
@@ -123,7 +123,7 @@ def configureAttributes() {
|
||||
}
|
||||
|
||||
def refreshAttributes() {
|
||||
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh() + zigbee.readAttribute(0x0300, 0x00) + zigbee.readAttribute(0x0300, ATTRIBUTE_HUE) + zigbee.readAttribute(0x0300, ATTRIBUTE_SATURATION)
|
||||
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh() + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION)
|
||||
}
|
||||
|
||||
def setColorTemperature(value) {
|
||||
@@ -141,10 +141,10 @@ def setColor(value){
|
||||
|
||||
def setHue(value) {
|
||||
def scaledHueValue = zigbee.convertToHexString(Math.round(value * 0xfe / 100.0), 2)
|
||||
zigbee.command(COLOR_CONTROL_CLUSTER, HUE_COMMAND, scaledHueValue, "00", "0500") //payload-> hue value, direction (00-> shortest distance), transition time (1/10th second) (0500 in U16 reads 5)
|
||||
zigbee.command(COLOR_CONTROL_CLUSTER, HUE_COMMAND, scaledHueValue, "00", "0500") + ["delay 1500"] + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_HUE) //payload-> hue value, direction (00-> shortest distance), transition time (1/10th second) (0500 in U16 reads 5)
|
||||
}
|
||||
|
||||
def setSaturation(value) {
|
||||
def scaledSatValue = zigbee.convertToHexString(Math.round(value * 0xfe / 100.0), 2)
|
||||
zigbee.command(COLOR_CONTROL_CLUSTER, SATURATION_COMMAND, scaledSatValue, "0500") //payload-> sat value, transition time
|
||||
zigbee.command(COLOR_CONTROL_CLUSTER, SATURATION_COMMAND, scaledSatValue, "0500") + ["delay 1500"] + zigbee.readAttribute(COLOR_CONTROL_CLUSTER, ATTRIBUTE_SATURATION) //payload-> sat value, transition time
|
||||
}
|
||||
|
||||
@@ -11,6 +11,9 @@
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
*/
|
||||
import groovy.transform.Field
|
||||
|
||||
@Field Boolean hasConfiguredHealthCheck = false
|
||||
|
||||
metadata {
|
||||
definition (name: "ZLL White Color Temperature Bulb", namespace: "smartthings", author: "SmartThings") {
|
||||
@@ -22,6 +25,7 @@ metadata {
|
||||
capability "Refresh"
|
||||
capability "Switch"
|
||||
capability "Switch Level"
|
||||
capability "Health Check"
|
||||
|
||||
attribute "colorName", "string"
|
||||
command "setGenericName"
|
||||
@@ -96,9 +100,41 @@ def poll() {
|
||||
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh()
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
return zigbee.levelRefresh()
|
||||
}
|
||||
|
||||
def healthPoll() {
|
||||
log.debug "healthPoll()"
|
||||
def cmds = zigbee.onOffRefresh() + zigbee.levelRefresh()
|
||||
cmds.each{ sendHubCommand(new physicalgraph.device.HubAction(it))}
|
||||
}
|
||||
|
||||
def configureHealthCheck() {
|
||||
Integer hcIntervalMinutes = 12
|
||||
if (!hasConfiguredHealthCheck) {
|
||||
log.debug "Configuring Health Check, Reporting"
|
||||
unschedule("healthPoll")
|
||||
runEvery5Minutes("healthPoll")
|
||||
// Device-Watch allows 2 check-in misses from device
|
||||
sendEvent(name: "checkInterval", value: hcIntervalMinutes * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
|
||||
hasConfiguredHealthCheck = true
|
||||
}
|
||||
}
|
||||
|
||||
def configure() {
|
||||
log.debug "Configuring Reporting and Bindings."
|
||||
log.debug "configure()"
|
||||
configureHealthCheck()
|
||||
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.colorTemperatureConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh()
|
||||
|
||||
}
|
||||
|
||||
def updated() {
|
||||
log.debug "updated()"
|
||||
configureHealthCheck()
|
||||
}
|
||||
|
||||
def setColorTemperature(value) {
|
||||
|
||||
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
39
devicetypes/smartthings/zwave-switch-generic.src/README.md
Normal file
39
devicetypes/smartthings/zwave-switch-generic.src/README.md
Normal file
@@ -0,0 +1,39 @@
|
||||
# Z-wave Switch
|
||||
|
||||
|
||||
|
||||
Works with:
|
||||
|
||||
* [Leviton Appliance Module (DZPA1-1LW)](https://support.smartthings.com/hc/en-us/articles/205881176-Leviton-Appliance-Module-DZPA1-1LW-)
|
||||
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave)](https://support.smartthings.com/hc/en-us/articles/200903080-GE-Plug-In-Outdoor-Smart-Switch-GE-12720-Z-Wave-)
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Polling** - represents that poll() can be implemented for the device
|
||||
* **Refresh** - _refresh()_ command for status updates
|
||||
* **Sensor** - detects sensor events
|
||||
|
||||
## Device Health
|
||||
|
||||
A Category C5 Leviton Appliance Module (DZPA1-1LW) and GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [Leviton Appliance Module (DZPA1-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205881176-Leviton-Appliance-Module-DZPA1-1LW-)
|
||||
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200903080-GE-Plug-In-Outdoor-Smart-Switch-GE-12720-Z-Wave-)
|
||||
@@ -14,12 +14,15 @@
|
||||
metadata {
|
||||
definition (name: "Z-Wave Switch Generic", namespace: "smartthings", author: "SmartThings") {
|
||||
capability "Actuator"
|
||||
capability "Health Check"
|
||||
capability "Switch"
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
|
||||
fingerprint inClusters: "0x25", deviceJoinName: "Z-Wave Switch"
|
||||
fingerprint mfr:"001D", prod:"1A02", deviceJoinName: "Z-Wave Switch"
|
||||
fingerprint mfr:"0063", prod:"4F50", deviceJoinName: "Z-Wave Switch"
|
||||
}
|
||||
|
||||
// simulator metadata
|
||||
@@ -50,6 +53,11 @@ metadata {
|
||||
}
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for checkInterval duration of 32min = 2 * 15min + 2min lag time
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def result = null
|
||||
def cmd = zwave.parse(description, [0x20: 1, 0x70: 1])
|
||||
@@ -126,6 +134,13 @@ def poll() {
|
||||
])
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
* */
|
||||
def ping() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
delayBetween([
|
||||
zwave.switchBinaryV1.switchBinaryGet().format(),
|
||||
|
||||
2
devicetypes/smartthings/zwave-switch.src/.st-ignore
Normal file
2
devicetypes/smartthings/zwave-switch.src/.st-ignore
Normal file
@@ -0,0 +1,2 @@
|
||||
.st-ignore
|
||||
README.md
|
||||
49
devicetypes/smartthings/zwave-switch.src/README.md
Normal file
49
devicetypes/smartthings/zwave-switch.src/README.md
Normal file
@@ -0,0 +1,49 @@
|
||||
# Z-Wave Switch
|
||||
|
||||
|
||||
Works with:
|
||||
|
||||
* [GE Z-Wave Plug-In Smart Switch (12719)](http://products.z-wavealliance.org/products/1193)
|
||||
* [GE Z-Wave In-Wall Smart Outlet (12721)](http://products.z-wavealliance.org/products/1195)
|
||||
* [GE Z-Wave In-Wall Smart Switch (12722)](http://products.z-wavealliance.org/products/1196)
|
||||
* [GE Z-Wave In-Wall Smart Toggle Switch (12727)](http://products.z-wavealliance.org/products/1200)
|
||||
|
||||
|
||||
## Table of contents
|
||||
|
||||
* [Capabilities](#capabilities)
|
||||
* [Health](#device-health)
|
||||
* [Troubleshooting](#Troubleshooting)
|
||||
|
||||
## Capabilities
|
||||
|
||||
* **Actuator** - represents that a Device has commands
|
||||
* **Indicator** - gives you the ability to set the indicator LED light on a Z-Wave switch
|
||||
* **Switch** - can detect state (possible values: on/off)
|
||||
* **Polling** - represents that poll() can be implemented for the device
|
||||
* **Refresh** - _refresh()_ command for status updates
|
||||
* **Sensor** - detects sensor events
|
||||
* **Health Check** - indicates ability to get device health notifications
|
||||
|
||||
## Device Health
|
||||
|
||||
Z-Wave Switches (Plug-In, In-Wall(Toggle Switch, Switch, Outlet)) are polled by the hub.
|
||||
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
|
||||
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
|
||||
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
|
||||
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
|
||||
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
|
||||
|
||||
|
||||
## Troubleshooting
|
||||
|
||||
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
|
||||
Pairing needs to be tried again by placing the device closer to the hub.
|
||||
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
|
||||
* [General Z-Wave Dimmer/Switch Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200955890-Troubleshooting-GE-in-wall-switch-or-dimmer-won-t-respond-to-commands-or-automations-Z-Wave-)
|
||||
* [GE Z-Wave Plug-In Smart Switch (12719) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200903070-GE-Plug-In-Smart-Switch-GE-12719-Z-Wave)
|
||||
* [GE Z-Wave In-Wall Smart Outlet (12721) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200903020-GE-In-Wall-Smart-Outlet-GE-12721-Z-Wave)
|
||||
* [GE Z-Wave In-Wall Smart Switch (12722) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200902540-GE-In-Wall-Smart-Switch-GE-12722-Z-Wave)
|
||||
* [GE Z-Wave In-Wall Smart Toggle Switch (12727) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/207568933-GE-In-Wall-Smart-Toggle-Switch-GE-12727-Z-Wave)
|
||||
|
||||
|
||||
@@ -19,6 +19,7 @@ metadata {
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Health Check"
|
||||
|
||||
fingerprint mfr:"0063", prod:"4952", deviceJoinName: "Z-Wave Wall Switch"
|
||||
fingerprint mfr:"0063", prod:"5257", deviceJoinName: "Z-Wave Wall Switch"
|
||||
@@ -64,6 +65,8 @@ metadata {
|
||||
}
|
||||
|
||||
def updated(){
|
||||
// Device-Watch simply pings if no device events received for 32min(checkInterval)
|
||||
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
|
||||
switch (ledIndicator) {
|
||||
case "on":
|
||||
indicatorWhenOn()
|
||||
@@ -156,6 +159,13 @@ def poll() {
|
||||
])
|
||||
}
|
||||
|
||||
/**
|
||||
* PING is used by Device-Watch in attempt to reach the Device
|
||||
**/
|
||||
def ping() {
|
||||
refresh()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
delayBetween([
|
||||
zwave.switchBinaryV1.switchBinaryGet().format(),
|
||||
|
||||
Reference in New Issue
Block a user