Compare commits

...

14 Commits

Author SHA1 Message Date
Vinay Rao
ea3abb26c0 Merge pull request #2088 from SmartThingsCommunity/staging
Rolling up staging to production
2017-06-13 14:10:07 -07:00
Vinay Rao
16f41bddae Merge pull request #2080 from workingmonk/bug/mark_files_deprecated
SLC-82 Marking old connect apps and device types as deprecated
2017-06-09 13:01:45 -07:00
Vinay Rao
117adea586 SLC-82 Marking old connect apps and device types as deprecated 2017-06-09 11:44:06 -07:00
Vinay Rao
783538e36d Merge pull request #2070 from dkirker/ICP-1097
ICP-1097 Fix Sengled Classic default level on pairing
2017-06-08 16:28:50 -07:00
Vinay Rao
6110aaa0fa Merge pull request #2074 from SmartThingsCommunity/master
Rolling up master to staging
2017-06-06 12:01:26 -07:00
Vinay Rao
c391ce4b43 Merge pull request #2073 from SmartThingsCommunity/staging
Rolling down staging to master
2017-06-06 11:55:16 -07:00
Vinay Rao
073bac8dac Merge pull request #2069 from larsfinander/DVCSMP-2688_Remove_sending_turningOn_Off_events_staging
DVCSMP-2688 Remove sending turningOn/Off events
2017-06-06 11:50:59 -07:00
Donald Kirker
6325101f52 ICP-1097 Fix Sengled Classic default level on pairing
Code brought oever from @varzac commit 8bcbe7b924
Original commit message:

> Fix sengled use of FF for max level
> This works around the fact that sengled element touches can get back
> into a state of reporting an invalid value (of FF) if the physical
> button on the bulb is used to cycle back to the 100% state.  Here we
> interpret FF as FE for sengled and then issue a move to level command to
> put it in a state where it will report FE until the level is changed
> again.
>
> This resolves: https://smartthings.atlassian.net/browse/DVCSMP-2597

While the Classic does not have a physical button, since it does represent 100% as FF we want to always catch this.
2017-06-06 03:29:41 -07:00
Lars Finander
945a972082 DVCSMP-2688 Remove sending turningOn/Off events
-Removed createSwitchEvent()
2017-06-05 16:50:03 -06:00
Tom Manley
535fc112de Merge pull request #2055 from jmagnuson/DVCSMP-2537
DVCSMP-2537 Add CRC16 un-encapsulation to Z-Wave switches
2017-06-02 16:36:50 -05:00
Jon Magnuson
a844e85c47 Remove extra comment slash 2017-06-02 16:25:04 -05:00
Vinay Rao
60f6e9c02c Merge pull request #2064 from SmartThingsCommunity/staging
Rolling down staging to master
2017-05-31 13:56:22 -07:00
Jon Magnuson
8aceef9be4 Add CRC16 un-encapsulation to Z-Wave switches
Fixes DVCSMP-2663 and DVCSMP-2537.
2017-05-25 17:07:12 -05:00
Vinay Rao
a1f39849ed Merge pull request #2043 from SmartThingsCommunity/staging
Rolling down staging to master
2017-05-25 10:58:53 -07:00
19 changed files with 165 additions and 51 deletions

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Bose SoundTouch
*

View File

@@ -108,11 +108,20 @@ def updated(){
}
}
def getCommandClassVersions() {
[
0x20: 1, // Basic
0x26: 1, // SwitchMultilevel
0x56: 1, // Crc16Encap
0x70: 1, // Configuration
]
}
def parse(String description) {
def result = null
if (description != "updated") {
log.debug "parse() >> zwave.parse($description)"
def cmd = zwave.parse(description, [0x20: 1, 0x26: 1, 0x70: 1])
def cmd = zwave.parse(description, commandClassVersions)
if (cmd) {
result = zwaveEvent(cmd)
}
@@ -179,6 +188,16 @@ def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelS
[createEvent(name:"switch", value:"on"), response(zwave.switchMultilevelV1.switchMultilevelGet().format())]
}
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
def versions = commandClassVersions
def version = versions[cmd.commandClass as Integer]
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
// Handles all Z-Wave commands we aren't interested in
[:]

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Bloom
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Bridge
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Bulb
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Lux Bulb
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue White Ambiance Bulb
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Copyright 2015 SmartThings
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Copyright 2015 SmartThings
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Copyright 2015 SmartThings
*

View File

@@ -66,22 +66,29 @@ def parse(String description) {
else {
sendEvent(event)
}
}
else {
def cluster = zigbee.parse(description)
if (cluster && cluster.clusterId == 0x0006 && cluster.command == 0x07) {
if (cluster.data[0] == 0x00) {
} else {
def descMap = zigbee.parseDescriptionAsMap(description)
if (descMap && descMap.clusterInt == 0x0006 && descMap.commandInt == 0x07) {
if (descMap.data[0] == "00") {
log.debug "ON/OFF REPORTING CONFIG RESPONSE: " + cluster
sendEvent(name: "checkInterval", value: 60 * 12, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
}
else {
} else {
log.warn "ON/OFF REPORTING CONFIG FAILED- error code:${cluster.data[0]}"
}
}
else {
} else if (device.getDataValue("manufacturer") == "sengled" && descMap && descMap.clusterInt == 0x0008 && descMap.attrInt == 0x0000) {
// This is being done because the sengled element touch/classic incorrectly uses the value 0xFF for the max level.
// Per the ZCL spec for the UINT8 data type 0xFF is an invalid value, and 0xFE should be the max. Here we
// manually handle the invalid attribute value since it will be ignored by getEvent as an invalid value.
// We also set the level of the bulb to 0xFE so future level reports will be 0xFE until it is changed by
// something else.
if (descMap.value.toUpperCase() == "FF") {
descMap.value = "FE"
}
sendHubCommand(zigbee.command(zigbee.LEVEL_CONTROL_CLUSTER, 0x00, "FE0000").collect { new physicalgraph.device.HubAction(it) }, 0)
sendEvent(zigbee.getEventFromAttrData(descMap.clusterInt, descMap.attrInt, descMap.encoding, descMap.value))
} else {
log.warn "DID NOT PARSE MESSAGE for description : $description"
log.debug "${cluster}"
log.debug "${descMap}"
}
}
}

View File

@@ -88,11 +88,20 @@ def updated(){
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
def getCommandClassVersions() {
[
0x20: 1, // Basic
0x26: 1, // SwitchMultilevel
0x56: 1, // Crc16Encap
0x70: 1, // Configuration
]
}
def parse(String description) {
def result = null
if (description != "updated") {
log.debug "parse() >> zwave.parse($description)"
def cmd = zwave.parse(description, [0x20: 1, 0x26: 1, 0x70: 1])
def cmd = zwave.parse(description, commandClassVersions)
if (cmd) {
result = zwaveEvent(cmd)
}
@@ -159,6 +168,16 @@ def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelS
[createEvent(name:"switch", value:"on"), response(zwave.switchMultilevelV1.switchMultilevelGet().format())]
}
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
def versions = commandClassVersions
def version = versions[cmd.commandClass as Integer]
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
// Handles all Z-Wave commands we aren't interested in
[:]

View File

@@ -85,11 +85,21 @@ metadata {
details(["switch", "power", "energy", "levelSliderControl", "refresh", "reset"])
}
def getCommandClassVersions() {
[
0x20: 1, // Basic
0x26: 3, // SwitchMultilevel
0x56: 1, // Crc16Encap
0x70: 1, // Configuration
0x32: 3, // Meter
]
}
// parse events into attributes
def parse(String description) {
def result = null
if (description != "updated") {
def cmd = zwave.parse(description, [0x20: 1, 0x26: 3, 0x70: 1, 0x32:3])
def cmd = zwave.parse(description, commandClassVersions)
if (cmd) {
result = zwaveEvent(cmd)
log.debug("'$description' parsed to $result")
@@ -124,6 +134,21 @@ def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv3.SwitchMultilevelR
dimmerEvents(cmd)
}
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
def versions = commandClassVersions
def version = versions[cmd.commandClass as Integer]
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
// Handles all Z-Wave commands we aren't interested in
[:]
}
def dimmerEvents(physicalgraph.zwave.Command cmd) {
def result = []
def value = (cmd.value ? "on" : "off")

View File

@@ -89,10 +89,19 @@ def updated() {
} catch (e) { log.debug e }
}
def getCommandClassVersions() {
[
0x20: 1, // Basic
0x32: 1, // SwitchMultilevel
0x56: 1, // Crc16Encap
0x72: 2, // ManufacturerSpecific
]
}
def parse(String description) {
def result = null
if(description == "updated") return
def cmd = zwave.parse(description, [0x20: 1, 0x32: 1, 0x72: 2])
def cmd = zwave.parse(description, commandClassVersions)
if (cmd) {
result = zwaveEvent(cmd)
}
@@ -157,6 +166,16 @@ def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerS
result
}
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
def versions = commandClassVersions
def version = versions[cmd.commandClass as Integer]
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
log.debug "$device.displayName: Unhandled: $cmd"
[:]

View File

@@ -71,9 +71,17 @@ def updated(){
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
def getCommandClassVersions() {
[
0x20: 1, // Basic
0x56: 1, // Crc16Encap
0x70: 1, // Configuration
]
}
def parse(String description) {
def result = null
def cmd = zwave.parse(description, [0x20: 1, 0x70: 1])
def cmd = zwave.parse(description, commandClassVersions)
if (cmd) {
result = createEvent(zwaveEvent(cmd))
}
@@ -120,6 +128,15 @@ def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerS
createEvent([descriptionText: "$device.displayName MSR: $msr", isStateChange: false])
}
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
def versions = commandClassVersions
def version = versions[cmd.commandClass as Integer]
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
// Handles all Z-Wave commands we aren't interested in

View File

@@ -89,9 +89,17 @@ def updated(){
}
}
def getCommandClassVersions() {
[
0x20: 1, // Basic
0x56: 1, // Crc16Encap
0x70: 1, // Configuration
]
}
def parse(String description) {
def result = null
def cmd = zwave.parse(description, [0x20: 1, 0x70: 1])
def cmd = zwave.parse(description, commandClassVersions)
if (cmd) {
result = createEvent(zwaveEvent(cmd))
}
@@ -138,6 +146,16 @@ def zwaveEvent(physicalgraph.zwave.commands.manufacturerspecificv2.ManufacturerS
createEvent([descriptionText: "$device.displayName MSR: $msr", isStateChange: false])
}
def zwaveEvent(physicalgraph.zwave.commands.crc16encapv1.Crc16Encap cmd) {
def versions = commandClassVersions
def version = versions[cmd.commandClass as Integer]
def ccObj = version ? zwave.commandClass(cmd.commandClass, version) : zwave.commandClass(cmd.commandClass)
def encapsulatedCommand = ccObj?.command(cmd.command)?.parse(cmd.data)
if (encapsulatedCommand) {
zwaveEvent(encapsulatedCommand)
}
}
def zwaveEvent(physicalgraph.zwave.Command cmd) {
// Handles all Z-Wave commands we aren't interested in

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Bose SoundTouch (Connect)
*

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**
* Hue Service Manager
*
@@ -1083,7 +1085,6 @@ def on(childDevice) {
log.debug "Executing 'on'"
def id = getId(childDevice)
updateInProgress()
createSwitchEvent(childDevice, "on")
put("lights/$id/state", [on: true])
return "Bulb is turning On"
}
@@ -1092,7 +1093,6 @@ def off(childDevice) {
log.debug "Executing 'off'"
def id = getId(childDevice)
updateInProgress()
createSwitchEvent(childDevice, "off")
put("lights/$id/state", [on: false])
return "Bulb is turning Off"
}
@@ -1108,8 +1108,6 @@ def setLevel(childDevice, percent) {
else
level = Math.min(Math.round(percent * 254 / 100), 254)
createSwitchEvent(childDevice, level > 0, percent)
// For Zigbee lights, if level is set to 0 ST just turns them off without changing level
// that means that the light will still be on when on is called next time
// Lets emulate that here
@@ -1128,7 +1126,6 @@ def setSaturation(childDevice, percent) {
// 0 - 254
def level = Math.min(Math.round(percent * 254 / 100), 254)
// TODO should this be done by app only or should we default to on?
createSwitchEvent(childDevice, "on")
put("lights/$id/state", [sat: level, on: true])
return "Setting saturation to $percent"
}
@@ -1140,7 +1137,6 @@ def setHue(childDevice, percent) {
// 0 - 65535
def level = Math.min(Math.round(percent * 65535 / 100), 65535)
// TODO should this be done by app only or should we default to on?
createSwitchEvent(childDevice, "on")
put("lights/$id/state", [hue: level, on: true])
return "Setting hue to $percent"
}
@@ -1151,7 +1147,6 @@ def setColorTemperature(childDevice, huesettings) {
updateInProgress()
// 153 (6500K) to 500 (2000K)
def ct = hueSettings == 6500 ? 153 : Math.round(1000000 / huesettings)
createSwitchEvent(childDevice, "on")
put("lights/$id/state", [ct: ct, on: true])
return "Setting color temperature to $ct"
}
@@ -1210,7 +1205,6 @@ def setColor(childDevice, huesettings) {
if (huesettings.switch == "off")
value.on = false
createSwitchEvent(childDevice, value.on ? "on" : "off")
put("lights/$id/state", value)
return "Setting color to $value"
}
@@ -1322,32 +1316,6 @@ private List getRealHubFirmwareVersions() {
return location.hubs*.firmwareVersionString.findAll { it }
}
/**
* Sends appropriate turningOn/turningOff state events depending on switch or level changes.
*
* @param childDevice device to send event for
* @param setSwitch The new switch state, "on" or "off"
* @param setLevel Optional, switchLevel between 0-100, used if you set level to 0 for example since
* that should generate "off" instead of level change
*/
private void createSwitchEvent(childDevice, setSwitch, setLevel = null) {
if (setLevel == null) {
setLevel = childDevice.device?.currentValue("level")
}
// Create on, off, turningOn or turningOff event as necessary
def currentState = childDevice.device?.currentValue("switch")
if ((currentState == "off" || currentState == "turningOff")) {
if (setSwitch == "on" || setLevel > 0) {
childDevice.sendEvent(name: "switch", value: "turningOn", displayed: false)
}
} else if ((currentState == "on" || currentState == "turningOn")) {
if (setSwitch == "off" || setLevel == 0) {
childDevice.sendEvent(name: "switch", value: "turningOff", displayed: false)
}
}
}
/**
* Return the supported color range for different Hue lights. If model is not specified
* it defaults to the smallest Gamut (B) to ensure that colors set on a mix of devices

View File

@@ -1,3 +1,5 @@
//DEPRECATED. INTEGRATION MOVED TO SUPER LAN CONNECT
/**