Compare commits

...

24 Commits

Author SHA1 Message Date
tech enerlites
0fddbd93ae MSA-1551: metadata {
// Automatically generated. Make future change here.
	definition (name: "Zigbee Dimmer", namespace: "Enerwave", author: "Home Automation") {
		capability "Actuator"
		capability "Switch"
		capability "Sensor"
                capability "Switch Level"
                capability "Refresh"

		fingerprint profileId: "0104", inClusters: "0000,0003,0006,0008", outClusters: "0019"
	}

	// simulator metadata
	simulator {
		// status messages
		status "on": "on/off: 1"
		status "off": "on/off: 0"

		// reply messages
		reply "zcl on-off on": "on/off: 1"
		reply "zcl on-off off": "on/off: 0"
	}

	// UI tile definitions
	tiles {
		standardTile("switch", "device.switch", width: 2, height: 2, canChangeIcon: true) {
                    state "off", label: '${name}', action: "switch.on", icon: "st.switches.switch.off", backgroundColor: "#ffffff"
	            state "on", label: '${name}', action: "switch.off", icon: "st.switches.switch.on", backgroundColor: "#79b821"
		}
                standardTile("refresh", "device.switch", inactiveLabel: false, decoration: "flat") {
                    state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
                }
                controlTile("levelSliderControl", "device.level", "slider", height: 1, width: 3, inactiveLabel: false) {
	            state "level", action:"switch level.setLevel"
		}
                valueTile("level", "device.level", inactiveLabel: false, decoration: "flat") {
		    state "level", label:'${currentValue} %', unit:"%", backgroundColor:"#ffffff"
		}

		main "switch"
		details (["switch","refresh","level","levelSliderControl"])
	}
}

// Parse incoming device messages to generate events
def parse(String description) {
	/*if (description?.startsWith("catchall: 0104 000A")) {
		log.debug "Dropping catchall for SmartPower Outlet"
		return []
	}*/
    log.trace description
    if (description?.startsWith("catchall:")) {
		def msg = zigbee.parse(description)
		log.trace msg
		log.trace "data: $msg.data"
        if(msg.command == 0x01){
        	if(msg.clusterId == 0x0006 && msg.data[0] == 0x00 && msg.data[1] == 0x00){
                def name = "switch" 
                def value = (msg.data[4] != 0 ? "on" : "off") 
                log.debug"name:$name,value:$value"
                def result = createEvent(name: name, value: value)
                return result
            }
        }else if(msg.command == 0x0b && msg.clusterId == 0x0006){
        	def name = "switch" 
            def value = (msg.data[0] != 0 ? "on" : "off") 
            log.debug"name:$name,value:$value"
            def result = createEvent(name: name, value: value)
            return result
        }
	}else if(description?.startsWith("read attr")){
    	def descMap = parseDescriptionAsMap(description)
		log.debug "Read attr: $description"
    	if(descMap.cluster == "0008" && descMap.attrId == "0000"){
        	def name = "level" 
            def value = Integer.parseInt(descMap.value, 16) 
            value = Math.round(value * 100/255)
            log.debug"name:$name,value:$value"
            def result = createEvent(name: name, value: value)
            return result
        }
    }/*else {
    	log.debug "parse description: $description"
		def name = description?.startsWith("on/off: ") ? "switch" : null
		def value = name == "switch" ? (description?.endsWith(" 1") ? "on" : "off") : null
		def result = createEvent(name: name, value: value)
		log.debug "Parse returned ${result?.descriptionText}"
		return result
	}*/
}

def parseDescriptionAsMap(description) {
	(description - "read attr - ").split(",").inject([:]) { map, param ->
		def nameAndValue = param.split(":")
		map += [(nameAndValue[0].trim()):nameAndValue[1].trim()]
	}
}

def refresh() {
	log.debug "refresh()"
    def cmds = []
    cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0006 0x0000"
    cmds << "delay 200"
    cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0008 0x0000"
}

// Commands to device
def on() {
	log.debug "on()"
    def cmds = []
	cmds << "st cmd 0x${device.deviceNetworkId} 1 6 1 {}"
    cmds << "delay 5000"
    cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0008 0x0000"
}

def off() {
	log.debug "off()"
    def cmds = []
	cmds << "st cmd 0x${device.deviceNetworkId} 1 6 0 {}"
    cmds << "delay 5000"
    cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0008 0x0000"
}

def setLevel(value) {
	log.trace "setLevel($value)"
	def cmds = []

	if (value == 0) {
		sendEvent(name: "switch", value: "off")
		//cmds << "st cmd 0x${device.deviceNetworkId} 1 6 0 {}"
	}
	else if (device.latestValue("switch") == "off") {
        sendEvent(name: "switch", value: "on")
        //cmds << "st cmd 0x${device.deviceNetworkId} 1 6 1 {}"
        
	}
    //def transitionTime = Math.round(Math.abs(((device.currentValue("level")?:0) as int) - (value as int))*0.3)
    //def transitionTime2 = hexString(transitionTime>>8)
    //def transitionTime1 = hexString(transitionTime%256)
	sendEvent(name: "level", value: value)
    def level = hexString(Math.round(value * 255/100))
	cmds << "st cmd 0x${device.deviceNetworkId} 1 8 4 {${level} FFFF}"
    cmds << "delay 5000"
    cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0008 0x0000"

	log.debug cmds
	cmds
}
2016-10-25 11:26:19 -05:00
Kevin Shuk
a9aee8fd96 Merge pull request #1367 from surfous/DVCSMP-2134-2135-ZLL-bulb-hchk2
Add health check for:
* DVCSMP-2134 ZLL white color temperature bulb
* DVCSMP-2135 ZLL dimmer bulb
2016-10-19 22:48:28 -07:00
Kevin Shuk
5c015cf678 DVCSMP-2135 health check ZLL dimmable bulb
* checkInterval set to 12 min (2 misses + leeway)
* configure a healthPoll every 5 min
 * refreshes on/off state, switch level, and white color temperature
 * schedule and set interval from either configure() or updated()
  * but only once per execution
* ping refreshes level setting
2016-10-19 22:40:23 -07:00
Kevin Shuk
cf1a46e309 DVCSMP-2134 health check ZLL white color temp bulb
* checkInterval set to 12 min (2 misses + leeway)
* configure a healthPoll every 5 min
 * refreshes on/off state, switch level, and white color temperature
 * schedule and set interval from either configure() or updated()
  * but only once per execution
* ping refreshes level setting
2016-10-19 22:38:57 -07:00
Jack Chi
1ff77dc608 Merge pull request #1355 from skt123/zwave_switch
[CHF-425] Health Check Implementation for Z-wave switch
2016-10-18 22:53:40 -07:00
Jack Chi
afbec02217 Merge pull request #1281 from parijatdas/leviton
[CHF-404] [CHF-422] Health check for Leviton DZPA1 Plug-in Appliance Module and GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave)
2016-10-18 22:51:44 -07:00
Jack Chi
434a72bd13 Merge pull request #1292 from pchomal/zwave_dimmer
CHF-406
2016-10-18 22:50:14 -07:00
sushant.k1
3fba7c9422 Added Health Check Implementation for following Z-wave switches:
1. Plug-In Smart Switch (GE 12719)
2. In-Wall Smart Outlet (GE 12721)
3. In-Wall Smart Switch (GE 12722)
4. In-Wall Smart Toggle Switch (GE 12727)

Added Health Check Implementation for following Z-wave switches:
1. Plug-In Smart Switch (GE 12719)
2. In-Wall Smart Outlet (GE 12721)
3. In-Wall Smart Switch (GE 12722)
4. In-Wall Smart Toggle Switch (GE 12727)
2016-10-19 10:18:38 +05:30
piyush.c
b63d4a9156 CHF-406
Updated HealthCheck Implementation for Z-wave Dimmer (GE 12718, GE 12724, GE 12729) with checkInterval of 32min
2016-10-19 10:06:38 +05:30
Parijat Das
6eb29ad019 Added health check for Leviton DZPA1 Plug-in Appliance Module and GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) along with the README.md 2016-10-19 08:45:53 +05:30
Vinay Rao
711cdc3ebf Merge pull request #1370 from SmartThingsCommunity/staging
Rolling down staging hotfix to master
2016-10-18 18:48:17 -07:00
Vinay Rao
f58a1ef589 Merge pull request #1369 from workingmonk/bug/osram_name
DVCSMP-1447 adding missing deviceJoinName in the generic dth
2016-10-18 18:47:35 -07:00
Vinay Rao
db5237ca33 adding missing deviceJoinName in the generic dth 2016-10-18 18:45:27 -07:00
Vinay Rao
7791c68a8a Merge pull request #1364 from SmartThingsCommunity/master
Rolling up master to staging
2016-10-18 14:40:53 -07:00
Vinay Rao
db4140ffd6 Merge pull request #1363 from SmartThingsCommunity/staging
Rolling down staging hotfix to master
2016-10-18 14:39:44 -07:00
Vinay Rao
ac422076c8 Merge pull request #1361 from SmartThingsCommunity/production
Rolling down production hotfix to staging
2016-10-18 14:02:37 -07:00
Lars Finander
c11c146690 Merge pull request #1349 from larsfinander/DVCSMP-2131_Philips_Hue_Handle_invalid_username_staging
DVCSMP-2131 Philips Hue: Handle case if bridge username becomes invalid
2016-10-18 10:39:02 -06:00
Lars Finander
9a5d506668 DVCSMP-2131 Philips Hue: Handle case if bridge username becomes invalid 2016-10-14 16:18:51 -06:00
Vinay Rao
9dac541473 Merge pull request #1338 from jackchi/health-checkInterval-value-fix
[CHF-417] Fix for onOffConfig older periodic values
2016-10-11 16:22:12 -07:00
jackchi
a6cc506803 [CHF-417] Fix for onOffConfig older periodic values 2016-10-11 16:18:06 -07:00
Vinay Rao
aba8a7ad4b Merge pull request #1337 from SmartThingsCommunity/master
Rolling up master to staging
2016-10-11 14:18:00 -07:00
Vinay Rao
b4c912ab80 Merge pull request #1336 from SmartThingsCommunity/staging
Rolling up staging to production for deploy
2016-10-11 13:23:51 -07:00
Vinay Rao
9f5eb7b85a Merge pull request #1316 from SmartThingsCommunity/staging
Rolling up staging to prod for deployment
2016-10-04 14:41:53 -07:00
Vinay Rao
aae7f23a22 Merge pull request #1302 from SmartThingsCommunity/staging
Rolling up staging for production deployment
2016-09-27 14:14:57 -07:00
18 changed files with 429 additions and 17 deletions

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,45 @@
# Z-wave Dimmer Switch
Works with:
* [GE Z-Wave In-Wall Smart Dimmer (GE 12724)](http://products.z-wavealliance.org/products/1197)
* [GE Z-Wave In-Wall Smart Dimmer (Toggle) (GE 12729)](http://products.z-wavealliance.org/products/1201)
* [GE Z-Wave Plug-in Smart Dimmer (GE 12718)](http://products.z-wavealliance.org/products/1191)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Troubleshooting](#Troubleshooting)
## Capabilities
* **Switch Level** - it's defined to accept two parameters, the level and the rate of dimming
* **Actuator** - represents that a Device has commands
* **Indicator** - gives you the ability to set the indicator LED light on a Z-Wave switch
* **Switch** - can detect state (possible values: on/off)
* **Polling** - represents that poll() can be implemented for the device
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - detects sensor events
* **Health Check** - indicates ability to get device health notifications
## Device Health
Z-Wave Smart Dimmers (In-Wall, In-Wall(Toggle), Plug-In) are polled by the hub.
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
Check-in interval = 32 mins.
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [General Z-Wave Dimmer/Switch Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200955890-Troubleshooting-GE-in-wall-switch-or-dimmer-won-t-respond-to-commands-or-automations-Z-Wave-)
* [GE Z-Wave In-Wall Smart Dimmer (GE 12724) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200902600-GE-In-Wall-Paddle-Dimmer-Switch-GE-12724-Z-Wave-)
* [GE Z-Wave In-Wall Smart Dimmer (Toggle) (GE 12729) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/207568463-GE-In-Wall-Smart-Toggle-Dimmer-GE-12729-Z-Wave-)
* [GE Z-Wave Plug-in Smart Dimmer (GE 12718) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/202088474-GE-Plug-In-Smart-Dimmer-GE-12718-Z-Wave-)

View File

@@ -20,6 +20,7 @@ metadata {
capability "Polling"
capability "Refresh"
capability "Sensor"
capability "Health Check"
fingerprint mfr:"0063", prod:"4457", deviceJoinName: "Z-Wave Wall Dimmer"
fingerprint mfr:"0063", prod:"4944", deviceJoinName: "Z-Wave Wall Dimmer"
@@ -82,6 +83,8 @@ metadata {
}
def updated(){
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
switch (ledIndicator) {
case "on":
indicatorWhenOn()
@@ -215,6 +218,13 @@ def poll() {
zwave.switchMultilevelV1.switchMultilevelGet().format()
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
refresh()
}
def refresh() {
log.debug "refresh() is called"
def commands = []

View File

@@ -0,0 +1,148 @@
metadata {
// Automatically generated. Make future change here.
definition (name: "MY Zigbee Dimmer255", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Switch"
capability "Sensor"
capability "Switch Level"
capability "Refresh"
fingerprint profileId: "0104", inClusters: "0000,0003,0006,0008", outClusters: "0019"
}
// simulator metadata
simulator {
// status messages
status "on": "on/off: 1"
status "off": "on/off: 0"
// reply messages
reply "zcl on-off on": "on/off: 1"
reply "zcl on-off off": "on/off: 0"
}
// UI tile definitions
tiles {
standardTile("switch", "device.switch", width: 2, height: 2, canChangeIcon: true) {
state "off", label: '${name}', action: "switch.on", icon: "st.switches.switch.off", backgroundColor: "#ffffff"
state "on", label: '${name}', action: "switch.off", icon: "st.switches.switch.on", backgroundColor: "#79b821"
}
standardTile("refresh", "device.switch", inactiveLabel: false, decoration: "flat") {
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
}
controlTile("levelSliderControl", "device.level", "slider", height: 1, width: 3, inactiveLabel: false) {
state "level", action:"switch level.setLevel"
}
valueTile("level", "device.level", inactiveLabel: false, decoration: "flat") {
state "level", label:'${currentValue} %', unit:"%", backgroundColor:"#ffffff"
}
main "switch"
details (["switch","refresh","level","levelSliderControl"])
}
}
// Parse incoming device messages to generate events
def parse(String description) {
/*if (description?.startsWith("catchall: 0104 000A")) {
log.debug "Dropping catchall for SmartPower Outlet"
return []
}*/
log.trace description
if (description?.startsWith("catchall:")) {
def msg = zigbee.parse(description)
log.trace msg
log.trace "data: $msg.data"
if(msg.command == 0x01){
if(msg.clusterId == 0x0006 && msg.data[0] == 0x00 && msg.data[1] == 0x00){
def name = "switch"
def value = (msg.data[4] != 0 ? "on" : "off")
log.debug"name:$name,value:$value"
def result = createEvent(name: name, value: value)
return result
}
}else if(msg.command == 0x0b && msg.clusterId == 0x0006){
def name = "switch"
def value = (msg.data[0] != 0 ? "on" : "off")
log.debug"name:$name,value:$value"
def result = createEvent(name: name, value: value)
return result
}
}else if(description?.startsWith("read attr")){
def descMap = parseDescriptionAsMap(description)
log.debug "Read attr: $description"
if(descMap.cluster == "0008" && descMap.attrId == "0000"){
def name = "level"
def value = Integer.parseInt(descMap.value, 16)
value = Math.round(value * 100/255)
log.debug"name:$name,value:$value"
def result = createEvent(name: name, value: value)
return result
}
}/*else {
log.debug "parse description: $description"
def name = description?.startsWith("on/off: ") ? "switch" : null
def value = name == "switch" ? (description?.endsWith(" 1") ? "on" : "off") : null
def result = createEvent(name: name, value: value)
log.debug "Parse returned ${result?.descriptionText}"
return result
}*/
}
def parseDescriptionAsMap(description) {
(description - "read attr - ").split(",").inject([:]) { map, param ->
def nameAndValue = param.split(":")
map += [(nameAndValue[0].trim()):nameAndValue[1].trim()]
}
}
def refresh() {
log.debug "refresh()"
def cmds = []
cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0006 0x0000"
cmds << "delay 200"
cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0008 0x0000"
}
// Commands to device
def on() {
log.debug "on()"
def cmds = []
cmds << "st cmd 0x${device.deviceNetworkId} 1 6 1 {}"
cmds << "delay 5000"
cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0008 0x0000"
}
def off() {
log.debug "off()"
def cmds = []
cmds << "st cmd 0x${device.deviceNetworkId} 1 6 0 {}"
cmds << "delay 5000"
cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0008 0x0000"
}
def setLevel(value) {
log.trace "setLevel($value)"
def cmds = []
if (value == 0) {
sendEvent(name: "switch", value: "off")
//cmds << "st cmd 0x${device.deviceNetworkId} 1 6 0 {}"
}
else if (device.latestValue("switch") == "off") {
sendEvent(name: "switch", value: "on")
//cmds << "st cmd 0x${device.deviceNetworkId} 1 6 1 {}"
}
//def transitionTime = Math.round(Math.abs(((device.currentValue("level")?:0) as int) - (value as int))*0.3)
//def transitionTime2 = hexString(transitionTime>>8)
//def transitionTime1 = hexString(transitionTime%256)
sendEvent(name: "level", value: value)
def level = hexString(Math.round(value * 255/100))
cmds << "st cmd 0x${device.deviceNetworkId} 1 8 4 {${level} FFFF}"
cmds << "delay 5000"
cmds << "st rattr 0x${device.deviceNetworkId} 1 0x0008 0x0000"
log.debug cmds
cmds
}

View File

@@ -143,7 +143,7 @@ def refresh() {
def configure() {
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
refresh() + zigbee.onOffConfig(0, 300) + powerConfig()

View File

@@ -104,7 +104,7 @@ def configure() {
log.debug "Configuring Reporting and Bindings."
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.onOffConfig(0, 300) + zigbee.levelConfig()

View File

@@ -28,8 +28,8 @@ metadata {
capability "Switch Level"
capability "Health Check"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "Gardenspot RGB"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY Gardenspot RGB"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "Gardenspot RGB", deviceJoinName: "OSRAM LIGHTIFY Gardenspot mini RGB"
fingerprint profileId: "0104", inClusters: "0000,0003,0004,0005,0006,0008,0300,0B04,FC0F", outClusters: "0019", manufacturer: "OSRAM", model: "LIGHTIFY Gardenspot RGB", deviceJoinName: "OSRAM LIGHTIFY Gardenspot mini RGB"
}
// UI tile definitions

View File

@@ -145,7 +145,7 @@ def configure() {
log.debug "Configuring Reporting and Bindings."
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
refresh()

View File

@@ -128,7 +128,7 @@ def configure() {
log.debug "Configuring Reporting and Bindings."
// Device-Watch allows 3 check-in misses from device (plus 1 min lag time)
// enrolls with default periodic reporting until newer 5 min interval is confirmed
sendEvent(name: "checkInterval", value: 3 * 60 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
sendEvent(name: "checkInterval", value: 3 * 10 * 60 + 1 * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
// OnOff minReportTime 0 seconds, maxReportTime 5 min. Reporting interval if no activity
refresh()

View File

@@ -11,6 +11,9 @@
* for the specific language governing permissions and limitations under the License.
*
*/
import groovy.transform.Field
@Field Boolean hasConfiguredHealthCheck = false
metadata {
definition (name: "ZLL Dimmer Bulb", namespace: "smartthings", author: "SmartThings") {
@@ -21,6 +24,7 @@ metadata {
capability "Refresh"
capability "Switch"
capability "Switch Level"
capability "Health Check"
//fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0000,0019"
fingerprint profileId: "C05E", inClusters: "0000, 0003, 0004, 0005, 0006, 0008, 1000", outClusters: "0019"
@@ -96,7 +100,38 @@ def poll() {
refresh()
}
def configure() {
log.debug "Configuring Reporting and Bindings."
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh()
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
return zigbee.levelRefresh()
}
def healthPoll() {
log.debug "healthPoll()"
def cmds = refresh()
cmds.each{ sendHubCommand(new physicalgraph.device.HubAction(it))}
}
def configureHealthCheck() {
Integer hcIntervalMinutes = 12
if (!hasConfiguredHealthCheck) {
log.debug "Configuring Health Check, Reporting"
unschedule("healthPoll")
runEvery5Minutes("healthPoll")
// Device-Watch allows 2 check-in misses from device
sendEvent(name: "checkInterval", value: hcIntervalMinutes * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
hasConfiguredHealthCheck = true
}
}
def configure() {
log.debug "configure()"
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh()
configureHealthCheck()
}
def updated() {
log.debug "updated()"
configureHealthCheck()
}

View File

@@ -11,6 +11,9 @@
* for the specific language governing permissions and limitations under the License.
*
*/
import groovy.transform.Field
@Field Boolean hasConfiguredHealthCheck = false
metadata {
definition (name: "ZLL White Color Temperature Bulb", namespace: "smartthings", author: "SmartThings") {
@@ -22,6 +25,7 @@ metadata {
capability "Refresh"
capability "Switch"
capability "Switch Level"
capability "Health Check"
attribute "colorName", "string"
command "setGenericName"
@@ -96,9 +100,41 @@ def poll() {
zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh()
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
return zigbee.levelRefresh()
}
def healthPoll() {
log.debug "healthPoll()"
def cmds = zigbee.onOffRefresh() + zigbee.levelRefresh()
cmds.each{ sendHubCommand(new physicalgraph.device.HubAction(it))}
}
def configureHealthCheck() {
Integer hcIntervalMinutes = 12
if (!hasConfiguredHealthCheck) {
log.debug "Configuring Health Check, Reporting"
unschedule("healthPoll")
runEvery5Minutes("healthPoll")
// Device-Watch allows 2 check-in misses from device
sendEvent(name: "checkInterval", value: hcIntervalMinutes * 60, displayed: false, data: [protocol: "zigbee", hubHardwareId: device.hub.hardwareID])
hasConfiguredHealthCheck = true
}
}
def configure() {
log.debug "Configuring Reporting and Bindings."
log.debug "configure()"
configureHealthCheck()
zigbee.onOffConfig() + zigbee.levelConfig() + zigbee.colorTemperatureConfig() + zigbee.onOffRefresh() + zigbee.levelRefresh() + zigbee.colorTemperatureRefresh()
}
def updated() {
log.debug "updated()"
configureHealthCheck()
}
def setColorTemperature(value) {

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,39 @@
# Z-wave Switch
Works with:
* [Leviton Appliance Module (DZPA1-1LW)](https://support.smartthings.com/hc/en-us/articles/205881176-Leviton-Appliance-Module-DZPA1-1LW-)
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave)](https://support.smartthings.com/hc/en-us/articles/200903080-GE-Plug-In-Outdoor-Smart-Switch-GE-12720-Z-Wave-)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Health Check** - indicates ability to get device health notifications
* **Switch** - can detect state (possible values: on/off)
* **Polling** - represents that poll() can be implemented for the device
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - detects sensor events
## Device Health
A Category C5 Leviton Appliance Module (DZPA1-1LW) and GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) polled by the hub.
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [Leviton Appliance Module (DZPA1-1LW) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/205881176-Leviton-Appliance-Module-DZPA1-1LW-)
* [GE Plug-In Outdoor Smart Switch (GE 12720) (Z-Wave) Troubleshooting Tips](https://support.smartthings.com/hc/en-us/articles/200903080-GE-Plug-In-Outdoor-Smart-Switch-GE-12720-Z-Wave-)

View File

@@ -14,12 +14,15 @@
metadata {
definition (name: "Z-Wave Switch Generic", namespace: "smartthings", author: "SmartThings") {
capability "Actuator"
capability "Health Check"
capability "Switch"
capability "Polling"
capability "Refresh"
capability "Sensor"
fingerprint inClusters: "0x25", deviceJoinName: "Z-Wave Switch"
fingerprint mfr:"001D", prod:"1A02", deviceJoinName: "Z-Wave Switch"
fingerprint mfr:"0063", prod:"4F50", deviceJoinName: "Z-Wave Switch"
}
// simulator metadata
@@ -50,6 +53,11 @@ metadata {
}
}
def updated(){
// Device-Watch simply pings if no device events received for checkInterval duration of 32min = 2 * 15min + 2min lag time
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
}
def parse(String description) {
def result = null
def cmd = zwave.parse(description, [0x20: 1, 0x70: 1])
@@ -126,6 +134,13 @@ def poll() {
])
}
/**
* PING is used by Device-Watch in attempt to reach the Device
* */
def ping() {
refresh()
}
def refresh() {
delayBetween([
zwave.switchBinaryV1.switchBinaryGet().format(),

View File

@@ -0,0 +1,2 @@
.st-ignore
README.md

View File

@@ -0,0 +1,49 @@
# Z-Wave Switch
Works with:
* [GE Z-Wave Plug-In Smart Switch (12719)](http://products.z-wavealliance.org/products/1193)
* [GE Z-Wave In-Wall Smart Outlet (12721)](http://products.z-wavealliance.org/products/1195)
* [GE Z-Wave In-Wall Smart Switch (12722)](http://products.z-wavealliance.org/products/1196)
* [GE Z-Wave In-Wall Smart Toggle Switch (12727)](http://products.z-wavealliance.org/products/1200)
## Table of contents
* [Capabilities](#capabilities)
* [Health](#device-health)
* [Troubleshooting](#Troubleshooting)
## Capabilities
* **Actuator** - represents that a Device has commands
* **Indicator** - gives you the ability to set the indicator LED light on a Z-Wave switch
* **Switch** - can detect state (possible values: on/off)
* **Polling** - represents that poll() can be implemented for the device
* **Refresh** - _refresh()_ command for status updates
* **Sensor** - detects sensor events
* **Health Check** - indicates ability to get device health notifications
## Device Health
Z-Wave Switches (Plug-In, In-Wall(Toggle Switch, Switch, Outlet)) are polled by the hub.
As of hubCore version 0.14.38 the hub sends up reports every 15 minutes regardless of whether the state changed.
Device-Watch allows 2 check-in misses from device plus some lag time. So Check-in interval = (2*15 + 2)mins = 32 mins.
Not to mention after going OFFLINE when the device is plugged back in, it might take a considerable amount of time for
the device to appear as ONLINE again. This is because if this listening device does not respond to two poll requests in a row,
it is not polled for 5 minutes by the hub. This can delay up the process of being marked ONLINE by quite some time.
## Troubleshooting
If the device doesn't pair when trying from the SmartThings mobile app, it is possible that the device is out of range.
Pairing needs to be tried again by placing the device closer to the hub.
Instructions related to pairing, resetting and removing the device from SmartThings can be found in the following link:
* [General Z-Wave Dimmer/Switch Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200955890-Troubleshooting-GE-in-wall-switch-or-dimmer-won-t-respond-to-commands-or-automations-Z-Wave-)
* [GE Z-Wave Plug-In Smart Switch (12719) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200903070-GE-Plug-In-Smart-Switch-GE-12719-Z-Wave)
* [GE Z-Wave In-Wall Smart Outlet (12721) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200903020-GE-In-Wall-Smart-Outlet-GE-12721-Z-Wave)
* [GE Z-Wave In-Wall Smart Switch (12722) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/200902540-GE-In-Wall-Smart-Switch-GE-12722-Z-Wave)
* [GE Z-Wave In-Wall Smart Toggle Switch (12727) Troubleshooting](https://support.smartthings.com/hc/en-us/articles/207568933-GE-In-Wall-Smart-Toggle-Switch-GE-12727-Z-Wave)

View File

@@ -19,6 +19,7 @@ metadata {
capability "Polling"
capability "Refresh"
capability "Sensor"
capability "Health Check"
fingerprint mfr:"0063", prod:"4952", deviceJoinName: "Z-Wave Wall Switch"
fingerprint mfr:"0063", prod:"5257", deviceJoinName: "Z-Wave Wall Switch"
@@ -64,6 +65,8 @@ metadata {
}
def updated(){
// Device-Watch simply pings if no device events received for 32min(checkInterval)
sendEvent(name: "checkInterval", value: 2 * 15 * 60 + 2 * 60, displayed: false, data: [protocol: "zwave", hubHardwareId: device.hub.hardwareID])
switch (ledIndicator) {
case "on":
indicatorWhenOn()
@@ -156,6 +159,13 @@ def poll() {
])
}
/**
* PING is used by Device-Watch in attempt to reach the Device
**/
def ping() {
refresh()
}
def refresh() {
delayBetween([
zwave.switchBinaryV1.switchBinaryGet().format(),

View File

@@ -37,7 +37,10 @@ preferences {
def mainPage() {
def bridges = bridgesDiscovered()
if (state.username && bridges) {
if (state.refreshUsernameNeeded) {
return bridgeLinking()
} else if (state.username && bridges) {
return bulbDiscovery()
} else {
return bridgeDiscovery()
@@ -102,13 +105,22 @@ def bridgeLinking() {
def nextPage = ""
def title = "Linking with your Hue"
def paragraphText
def paragraphText
if (selectedHue) {
if (state.refreshUsernameNeeded) {
paragraphText = "The current Hue username is invalid.\n\nPlease press the button on your Hue Bridge to re-link. "
} else {
paragraphText = "Press the button on your Hue Bridge to setup a link. "
} else {
paragraphText = "You haven't selected a Hue Bridge, please Press \"Done\" and select one before clicking next."
}
}
} else {
paragraphText = "You haven't selected a Hue Bridge, please Press \"Done\" and select one before clicking next."
}
if (state.username) { //if discovery worked
if (state.refreshUsernameNeeded) {
state.refreshUsernameNeeded = false
// Issue one poll with new username to cancel local polling with old username
poll()
}
nextPage = "bulbDiscovery"
title = "Success!"
paragraphText = "Linking to your hub was a success! Please click 'Next'!"
@@ -915,8 +927,15 @@ private handleCommandResponse(body) {
updates[childDeviceNetworkId]."$eventType" = v
}
}
} else if (payload.error) {
log.warn "Error returned from Hue bridge error = ${body?.error}"
} else if (payload?.error) {
log.warn "Error returned from Hue bridge, error = ${payload?.error}"
// Check for unauthorized user
if (payload?.error?.type?.value == 1) {
log.error "Hue username is not valid"
state.refreshUsernameNeeded = true
state.username = null
}
return []
}
}