@@ -0,0 +1,456 @@
|
||||
/**
|
||||
* Device Type Definition File
|
||||
*
|
||||
* Device Type: Fibaro Dimmer
|
||||
* File Name: fibaro-dimmer.groovy
|
||||
* Initial Release: 2015-06-00
|
||||
* Author: SmartThings
|
||||
*
|
||||
* Copyright 2015 SmartThings
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
|
||||
* in compliance with the License. You may obtain a copy of the License at:
|
||||
*
|
||||
* http://www.apache.org/licenses/LICENSE-2.0
|
||||
*
|
||||
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
|
||||
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
*/
|
||||
|
||||
metadata {
|
||||
// Automatically generated. Make future change here.
|
||||
definition (name: "Fibaro Dimmer 1", namespace: "smartthings", author: "SmartThings, Elnar Hajiyev") {
|
||||
capability "Switch Level"
|
||||
capability "Actuator"
|
||||
capability "Switch"
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Configuration"
|
||||
|
||||
//Extending Fibaro Dimmer 1 devices with scene attribute
|
||||
attribute "scene", "number"
|
||||
|
||||
command "configureParams"
|
||||
|
||||
fingerprint deviceId: "0x1101", inClusters: "0x72,0x86,0x70,0x85,0x8E,0x26,0x7A,0x27,0x73,0xEF,0x26,0x2B"
|
||||
}
|
||||
|
||||
simulator {
|
||||
status "on": "command: 2003, payload: FF"
|
||||
status "off": "command: 2003, payload: 00"
|
||||
status "09%": "command: 2003, payload: 09"
|
||||
status "10%": "command: 2003, payload: 0A"
|
||||
status "33%": "command: 2003, payload: 21"
|
||||
status "66%": "command: 2003, payload: 42"
|
||||
status "99%": "command: 2003, payload: 63"
|
||||
|
||||
// reply messages
|
||||
reply "2001FF,delay 5000,2602": "command: 2603, payload: FF"
|
||||
reply "200100,delay 5000,2602": "command: 2603, payload: 00"
|
||||
reply "200119,delay 5000,2602": "command: 2603, payload: 19"
|
||||
reply "200132,delay 5000,2602": "command: 2603, payload: 32"
|
||||
reply "20014B,delay 5000,2602": "command: 2603, payload: 4B"
|
||||
reply "200163,delay 5000,2602": "command: 2603, payload: 63"
|
||||
}
|
||||
|
||||
tiles {
|
||||
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){
|
||||
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
|
||||
attributeState "on", label:'${name}', action:"switch.off", icon:"st.switches.switch.on", backgroundColor:"#79b821", nextState:"turningOff"
|
||||
attributeState "off", label:'${name}', action:"switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff", nextState:"turningOn"
|
||||
attributeState "turningOn", label:'${name}', action:"switch.off", icon:"st.switches.switch.on", backgroundColor:"#79b821", nextState:"turningOff"
|
||||
attributeState "turningOff", label:'${name}', action:"switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff", nextState:"turningOn"
|
||||
}
|
||||
tileAttribute ("device.level", key: "SLIDER_CONTROL") {
|
||||
attributeState "level", action:"switch level.setLevel"
|
||||
}
|
||||
}
|
||||
standardTile("refresh", "device.switch", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
|
||||
state "default", label:"", action:"refresh.refresh", icon:"st.secondary.refresh"
|
||||
}
|
||||
standardTile("configureParams", "device.configure", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
|
||||
state "configure", label:'', action:"configureParams", icon:"st.secondary.configure"
|
||||
}
|
||||
|
||||
main(["switch"])
|
||||
details(["switch", "refresh",
|
||||
"levelSliderControl",
|
||||
"configureParams"
|
||||
])
|
||||
}
|
||||
|
||||
preferences {
|
||||
input name: "param1", type: "enum", defaultValue: "255", required: true,
|
||||
options: ["0" : "0",
|
||||
"1" : "1",
|
||||
"2" : "2",
|
||||
"255" : "255"],
|
||||
title: "1. Activate / deactivate functions ALL ON / ALL OFF.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = All ON not active, All OFF not active,\n" +
|
||||
"1 = All ON not active, All OFF active,\n" +
|
||||
"2 = All ON active, All OFF not active,\n" +
|
||||
"255 = All ON active, All OFF active.\n" +
|
||||
"Default value: 255."
|
||||
|
||||
input name: "param6", type: "number", range: "0..2", defaultValue: "0", required: true,
|
||||
title: "6. Sending commands to control devices assigned to 1st association group (key no. 1).\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = commands are sent when device is turned on and off.\n" +
|
||||
"1 = commands are sent when device is turned off. Enabling device does not send control commands. Double-clicking key sends 'turn on' command, dimmers memorize the last saved state (e.g. 50% brightness).\n" +
|
||||
"2 = commands are sent when device is turned off. Enabling device does not send control commands. Double-clicking key sends 'turn on' command and dimmers are set to 100% brightness.\n" +
|
||||
"Default value: 1.\n\n" +
|
||||
"NOTE: Parameter 15 value must be set to 1 to work properly. This activates the double-click functionality - dimmer/roller shutter control."
|
||||
|
||||
input name: "param7", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "7. Checking the device status before sending a control frame from the key no. 2.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = Device status is not checked.\n" +
|
||||
"1 = Device status is checked.\n" +
|
||||
"Default value: 1.\n\n" +
|
||||
"Info: Key no. 2 is not represented by any physical device expect of devices on association list. " +
|
||||
"This functionality prevents of lack of reaction on pressing key no. 2 through polling devices from list one by one and checking thier actual states.\n" +
|
||||
"It is not possible to check the device status before sending a control frame from the key no. 2 if roller blind switch is chosen in parameter 14 (value 2)\n" +
|
||||
"If devices state is checked before sending asociation then parameter 19 should be set to value 0."
|
||||
|
||||
input name: "param8", type: "number", range: "1..99", defaultValue: "1", required: true,
|
||||
title: "8. The percentage of a dimming step at automatic control.\n" +
|
||||
"Available settings: 1-99\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param9", type: "number", range: "1..255", defaultValue: "5", required: true,
|
||||
title: "9. Time of manually moving the Dimmer between the extreme dimming values.\n" +
|
||||
"Available settings: 1-255 (10ms – 2.5s)\n" +
|
||||
"Default value: 5."
|
||||
|
||||
input name: "param10", type: "number", range: "0..255", defaultValue: "1", required: true,
|
||||
title: "10. Time of Automatic moving the Dimmer between the extreme dimming values.\n" +
|
||||
"Available settings: 0-255 (0ms – 2.5s)\n" +
|
||||
"0 - this value disables the smooth change in light intensity\n" +
|
||||
"Default value: 1.\n\n" +
|
||||
"NOTE value 0 is required for inductive and capacitive devices unsuitable for dimming, (e.g. fluorescent lamps , motors etc.)."
|
||||
|
||||
input name: "param11", type: "number", range: "1..99", defaultValue: "1", required: true,
|
||||
title: "11. The percentage of a dimming step at manual control.\n" +
|
||||
"Available settings: 1-99\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param12", type: "number", range: "2..99", defaultValue: "99", required: true,
|
||||
title: "12. Maximum Dimmer level control.\n" +
|
||||
"Available settings: 2-99\n" +
|
||||
"Default value: 99."
|
||||
|
||||
input name: "param13", type: "number", range: "1..98", defaultValue: "2", required: true,
|
||||
title: "13. Minimum Dimmer level control\n" +
|
||||
"Available settings: 1-98\n" +
|
||||
"Default value: 2.\n\n" +
|
||||
"NOTE: The maximum level may not be lower than the minimum level.\n" +
|
||||
"Recommended values of parameters 12 and 13 (max and min level) for controlling the devices are as follows:\n" +
|
||||
"- AC motors [min 60%, max 99%]\n" +
|
||||
"- fluorescent lamps, fluorescent tubes, LED [min 98%, max 99%] [parameter 10 set to 0]"
|
||||
|
||||
input name: "param14", type: "number", range: "0..2", defaultValue: "0", required: true,
|
||||
title: "14. Switch type. Choose between momentary switch and toggle switch.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = momentary switch,\n" +
|
||||
"1 = toggle switch,\n" +
|
||||
"2 = Roller blind switch (UP / DOWN) - two switch keys operate the Dimmer.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param15", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "15. Double click option (set lightning at 100%).\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = Double click disabled,\n" +
|
||||
"1 = Double click enabled.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param16", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "16. Saving the state of the device after a power failure. The Dimmer will return to the last position before power failure.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = the Dimmer does not save the state after a power failure, it returns to 'off' position,\n" +
|
||||
"1 = the Dimmer saves its state before power failure.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param17", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "17. The function of 3 - way switch, provides the option to double key no. 1. " +
|
||||
"The Dimmer may control two toggle push-buttons or an infinite number of momentary push-buttons.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = the function of 3-way switch is disabled,\n" +
|
||||
"1 = the function of 3-way switch is enabled.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param18", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "18. The function of synchronizing the light level for associated devices. The Dimmer communicates the position to the associated device.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = function disabled,\n" +
|
||||
"1 = function enabled.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param19", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "19. Assigns bistable key status to the device status.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = [On / Off] device changes status on key status change.\n" +
|
||||
"1 = Device status depends on key status: ON when the key is ON, OFF when the key is OFF.\n"
|
||||
"Default value: 0.\n\n" +
|
||||
"Info: Remote control from Fibaro System Is Still Possible. This function is useful When you want display status of external devices, e.g. Motion Sensor, in Fibaro System."
|
||||
|
||||
input name: "param30", type: "number", range: "0..3", defaultValue: "3", required: true,
|
||||
title: "30. Alarm of any type (general alarm, water flooding alarm, smoke alarm: CO, CO2, temperature alarm).\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = DEACTIVATION - the device does not respond to alarm data frames,\n" +
|
||||
"1 = ALARM DIMMER ON - the device turns on after detecting an alarm,\n" +
|
||||
"2 = ALARM DIMMER OFF - the device turns off after detecting an alarm,\n" +
|
||||
"3 = ALARM FLASHING the device periodically changes its status to the opposite, when it detects an alarm within 10 min."
|
||||
"Default value: 3."
|
||||
|
||||
input name: "param39", type: "number", range: "1..65535", defaultValue: "600", required: true,
|
||||
title: "39. Active flashing alarm time.\n" +
|
||||
"Available settings: [1-65535][ms]\n" +
|
||||
"Default value: 600."
|
||||
|
||||
input name: "param41", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "41. Scene activation functionality.\n" +
|
||||
"The device offers the possibility of sending commands compatible with Command class scene activation. " +
|
||||
"Information is sent to devices assigned to association group no. 3. " +
|
||||
"Controllers such as Home Center 2 are able to interpret such commands and based on these commands they activate scenes, to which specific scene IDs have been assigned. " +
|
||||
"The user may expand the functionality of the button connected to inputs S1 and S2 by distinguishing the actions of keys connected to those inputs. " +
|
||||
"For example: double click would activate the scene “goodnight” and triple click would activate the scene “morning”.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = functionality deactivated,\n" +
|
||||
"1 = functionality activated.\n" +
|
||||
"Default value: 0.\n\n" +
|
||||
"Scene ID is determined as follows:\n" +
|
||||
"Momentary switch:\n" +
|
||||
"Input S1: holding down ID 12 (option inactive in case of roller blind switch), " +
|
||||
"releasing ID 13, double click ID 14 (depends on parameters 15 value - 1 = double click active), " +
|
||||
"triple click ID 15, one click ID 16.\n" +
|
||||
"Input S2: holding down ID 22 (option inactive in case of roller blind switch), " +
|
||||
"releasing ID 23, double click ID 24 (depends on parameters 15 value - 1 = double click active) option inactive in case of roller blind switch, " +
|
||||
"triple click ID 25, one click ID 26.\n\n" +
|
||||
"Toggle switch:\n" +
|
||||
"Input S1: holding down ID 12, releasing ID 13, double click ID 14 (depends on parameters 15 value - 1 = double click active), triple click ID 15. " +
|
||||
"If parameter no. 19 is set to 0: single click ID16 is sent. If parameter no. 19 is set to 1 following IDs are sent: switch from “off” to “on” ID 10, switch from “on” to “off” ID 11.\n" +
|
||||
"Input S2: holding down ID 22, releasing ID 23, double click ID 24, (depends on parameters 15 value - 1 = double click active), triple click ID 25. " +
|
||||
"If parameter no.19 set to 0 (default), then one click ID 26 is sent. If parameter no.19 is set to 1 following IDs are sent: switch from “off” to “on” ID 20, switch from “on” to “off” ID 21.\n\n" +
|
||||
"Roller blind switch:\n" +
|
||||
"Input S1, Turning on the light: switch from “off” to “on” ID 10, double click ID 14 (depends of parameter 15 value 1 - double click functionality), " +
|
||||
"triple click ID 15, brighten ID 17, releasing ID 13.\n" +
|
||||
"Input S2, Turning off the light: switch from “on” to “off” ID 11, triple click ID 25, dim ID 18, releasing ID 13."
|
||||
|
||||
input name: "param20", type: "number", range: "101..170", defaultValue: "110", required: true,
|
||||
title: "ADVANCED FUNCTION\n\n" +
|
||||
"20. The function enabling the change of control impulse length. " +
|
||||
"This function will enable decreasing the minimum level of the Dimmer by extending the control impulse. " +
|
||||
"By changing the minimum level, the user may completely dim LED bulbs. Not all LED bulbs available on the market have the dimming option.\n" +
|
||||
"Available settings:\n" +
|
||||
"Default values: 110 for 50Hz (UK), 101 for 60Hz (USA).\n\n"+
|
||||
"WARNING!\nWrong setting of the function may cause incorrect operation of the Dimmer."
|
||||
|
||||
input name: "paramAssociationGroup1", type: "bool", defaultValue: false, required: true,
|
||||
title: "The Dimmer 1 provides the association of three groups.\n\n" +
|
||||
"1 = 1st group is assigned to key no. 1,\n" +
|
||||
"Default value: true"
|
||||
|
||||
input name: "paramAssociationGroup2", type: "bool", defaultValue: false, required: true,
|
||||
title: "2nd group is assigned to key no. 2\n" +
|
||||
"Default value: true"
|
||||
|
||||
input name: "paramAssociationGroup3", type: "bool", defaultValue: true, required: true,
|
||||
title: "3rd group for controllers such Home Center for state reporting,\n" +
|
||||
"Default value: false"
|
||||
}
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
def item1 = [
|
||||
canBeCurrentState: false,
|
||||
linkText: getLinkText(device),
|
||||
isStateChange: false,
|
||||
displayed: false,
|
||||
descriptionText: description,
|
||||
value: description
|
||||
]
|
||||
def result
|
||||
def cmd = zwave.parse(description, [0x26: 1, 0x70: 2, 072: 2])
|
||||
//log.debug "cmd: ${cmd}"
|
||||
|
||||
if (cmd) {
|
||||
result = createEvent(cmd, item1)
|
||||
}
|
||||
else {
|
||||
item1.displayed = displayed(description, item1.isStateChange)
|
||||
result = [item1]
|
||||
}
|
||||
|
||||
if(result?.descriptionText)
|
||||
log.debug "Parse returned ${result?.descriptionText}"
|
||||
|
||||
result
|
||||
|
||||
}
|
||||
|
||||
def createEvent(physicalgraph.zwave.commands.sceneactivationv1.SceneActivationSet cmd, Map map) {
|
||||
log.debug( "Scene ID: $cmd.sceneId")
|
||||
log.debug( "Dimming Duration: $cmd.dimmingDuration")
|
||||
|
||||
sendEvent(name: "scene", value: "$cmd.sceneId", data: [switchType: "$settings.param20"], descriptionText: "Scene id $cmd.sceneId was activated", isStateChange: true)
|
||||
log.debug( "Scene id $cmd.sceneId was activated" )
|
||||
}
|
||||
|
||||
def createEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd, Map item1) {
|
||||
def result = doCreateEvent(cmd, item1)
|
||||
for (int i = 0; i < result.size(); i++) {
|
||||
result[i].type = "physical"
|
||||
}
|
||||
result
|
||||
}
|
||||
|
||||
def createEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd, Map item1) {
|
||||
def result = doCreateEvent(cmd, item1)
|
||||
for (int i = 0; i < result.size(); i++) {
|
||||
result[i].type = "physical"
|
||||
}
|
||||
result
|
||||
}
|
||||
|
||||
def createEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelStartLevelChange cmd, Map item1) {
|
||||
[]
|
||||
}
|
||||
|
||||
def createEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelStopLevelChange cmd, Map item1) {
|
||||
[response(zwave.basicV1.basicGet())]
|
||||
}
|
||||
|
||||
def createEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelSet cmd, Map item1) {
|
||||
def result = doCreateEvent(cmd, item1)
|
||||
for (int i = 0; i < result.size(); i++) {
|
||||
result[i].type = "physical"
|
||||
}
|
||||
result
|
||||
}
|
||||
|
||||
def createEvent(physicalgraph.zwave.commands.switchmultilevelv1.SwitchMultilevelReport cmd, Map item1) {
|
||||
def result = doCreateEvent(cmd, item1)
|
||||
result[0].descriptionText = "${item1.linkText} is ${item1.value}"
|
||||
result[0].handlerName = cmd.value ? "statusOn" : "statusOff"
|
||||
for (int i = 0; i < result.size(); i++) {
|
||||
result[i].type = "digital"
|
||||
}
|
||||
result
|
||||
}
|
||||
|
||||
def doCreateEvent(physicalgraph.zwave.Command cmd, Map item1) {
|
||||
def result = [item1]
|
||||
|
||||
item1.name = "switch"
|
||||
item1.value = cmd.value ? "on" : "off"
|
||||
item1.handlerName = item1.value
|
||||
item1.descriptionText = "${item1.linkText} was turned ${item1.value}"
|
||||
item1.canBeCurrentState = true
|
||||
item1.isStateChange = isStateChange(device, item1.name, item1.value)
|
||||
item1.displayed = item1.isStateChange
|
||||
|
||||
if (cmd.value >= 5) {
|
||||
def item2 = new LinkedHashMap(item1)
|
||||
item2.name = "level"
|
||||
item2.value = cmd.value as String
|
||||
item2.unit = "%"
|
||||
item2.descriptionText = "${item1.linkText} dimmed ${item2.value} %"
|
||||
item2.canBeCurrentState = true
|
||||
item2.isStateChange = isStateChange(device, item2.name, item2.value)
|
||||
item2.displayed = false
|
||||
result << item2
|
||||
}
|
||||
result
|
||||
}
|
||||
|
||||
def createEvent(physicalgraph.zwave.Command cmd, Map map) {
|
||||
// Handles any Z-Wave commands we aren't interested in
|
||||
log.debug "UNHANDLED COMMAND $cmd"
|
||||
}
|
||||
|
||||
def on() {
|
||||
log.info "on"
|
||||
delayBetween([zwave.basicV1.basicSet(value: 0xFF).format(), zwave.switchMultilevelV1.switchMultilevelGet().format()], 5000)
|
||||
}
|
||||
|
||||
def off() {
|
||||
delayBetween ([zwave.basicV1.basicSet(value: 0x00).format(), zwave.switchMultilevelV1.switchMultilevelGet().format()], 5000)
|
||||
}
|
||||
|
||||
def setLevel(value) {
|
||||
def level = Math.min(value as Integer, 99)
|
||||
delayBetween ([zwave.basicV1.basicSet(value: level).format(), zwave.switchMultilevelV1.switchMultilevelGet().format()], 5000)
|
||||
}
|
||||
|
||||
def setLevel(value, duration) {
|
||||
def level = Math.min(value as Integer, 99)
|
||||
def dimmingDuration = duration < 128 ? duration : 128 + Math.round(duration / 60)
|
||||
zwave.switchMultilevelV2.switchMultilevelSet(value: level, dimmingDuration: dimmingDuration).format()
|
||||
}
|
||||
|
||||
def poll() {
|
||||
zwave.switchMultilevelV1.switchMultilevelGet().format()
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
zwave.switchMultilevelV1.switchMultilevelGet().format()
|
||||
}
|
||||
|
||||
def createEvent(physicalgraph.zwave.commands.configurationv2.ConfigurationReport cmd, Map item1) {
|
||||
|
||||
log.debug "${device.displayName} parameter '${cmd.parameterNumber}' with a byte size of '${cmd.size}' is set to '${cmd.configurationValue}'"
|
||||
|
||||
}
|
||||
|
||||
def configureParams() {
|
||||
log.debug "Configuring ${device.displayName} parameters"
|
||||
def cmds = []
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 1, size: 1, scaledConfigurationValue: param1.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 6, size: 1, scaledConfigurationValue: param6.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 7, size: 1, scaledConfigurationValue: param7.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 8, size: 1, scaledConfigurationValue: param8.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 9, size: 1, scaledConfigurationValue: param9.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 10, size: 1, scaledConfigurationValue: param10.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 11, size: 1, scaledConfigurationValue: param11.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 13, size: 1, scaledConfigurationValue: param13.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 15, size: 1, scaledConfigurationValue: param15.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 16, size: 1, scaledConfigurationValue: param16.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 19, size: 1, scaledConfigurationValue: param19.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 20, size: 1, scaledConfigurationValue: param20.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 30, size: 1, scaledConfigurationValue: param30.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 39, size: 1, scaledConfigurationValue: param39.toInteger()).format()
|
||||
cmds << zwave.configurationV1.configurationSet(parameterNumber: 41, size: 1, scaledConfigurationValue: param41.toInteger()).format()
|
||||
|
||||
// Register for Group 1
|
||||
if(paramAssociationGroup1) {
|
||||
cmds << zwave.associationV2.associationSet(groupingIdentifier:1, nodeId: [zwaveHubNodeId]).format()
|
||||
}
|
||||
else {
|
||||
cmds << zwave.associationV2.associationRemove(groupingIdentifier:1, nodeId: [zwaveHubNodeId]).format()
|
||||
}
|
||||
// Register for Group 2
|
||||
if(paramAssociationGroup2) {
|
||||
cmds << zwave.associationV2.associationSet(groupingIdentifier:2, nodeId: [zwaveHubNodeId]).format()
|
||||
}
|
||||
else {
|
||||
cmds << zwave.associationV2.associationRemove(groupingIdentifier:2, nodeId: [zwaveHubNodeId]).format()
|
||||
}
|
||||
// Register for Group 3
|
||||
if(paramAssociationGroup3) {
|
||||
cmds << zwave.associationV2.associationSet(groupingIdentifier:3, nodeId: [zwaveHubNodeId]).format()
|
||||
}
|
||||
else {
|
||||
cmds << zwave.associationV2.associationRemove(groupingIdentifier:3, nodeId: [zwaveHubNodeId]).format()
|
||||
}
|
||||
|
||||
delayBetween(cmds, 500)
|
||||
}
|
||||
|
||||
def updated() {
|
||||
log.debug "updated()"
|
||||
response(["delay 2000"] + configureParams() + refresh())
|
||||
}
|
||||
@@ -0,0 +1,787 @@
|
||||
/**
|
||||
* Copyright 2015 SmartThings
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
|
||||
* in compliance with the License. You may obtain a copy of the License at:
|
||||
* http://www.apache.org/licenses/LICENSE-2.0
|
||||
*
|
||||
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
|
||||
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*
|
||||
*/
|
||||
metadata {
|
||||
definition (name: "Fibaro Dimmer 2", namespace: "smartthings", author: "Rajiv, Elnar Hajiyev") {
|
||||
capability "Energy Meter"
|
||||
capability "Actuator"
|
||||
capability "Switch"
|
||||
capability "Power Meter"
|
||||
capability "Polling"
|
||||
capability "Refresh"
|
||||
capability "Sensor"
|
||||
capability "Configuration"
|
||||
capability "Switch Level"
|
||||
|
||||
//Extending Fibaro Dimmer 2 devices with scene attribute
|
||||
attribute "scene", "number"
|
||||
|
||||
command "reset"
|
||||
command "configureAfterSecure"
|
||||
|
||||
fingerprint deviceId: "0x1001", inClusters: "0x5E, 0x20, 0x86, 0x72, 0x26, 0x5A, 0x59, 0x85, 0x73, 0x98, 0x7A, 0x56, 0x70, 0x31, 0x32, 0x8E, 0x60, 0x75, 0x71, 0x27, 0x22, 0xEF, 0x2B"
|
||||
}
|
||||
|
||||
// simulator metadata
|
||||
simulator {
|
||||
status "on": "command: 2003, payload: FF"
|
||||
status "off": "command: 2003, payload: 00"
|
||||
status "09%": "command: 2003, payload: 09"
|
||||
status "10%": "command: 2003, payload: 0A"
|
||||
status "33%": "command: 2003, payload: 21"
|
||||
status "66%": "command: 2003, payload: 42"
|
||||
status "99%": "command: 2003, payload: 63"
|
||||
|
||||
for (int i = 0; i <= 10000; i += 1000) {
|
||||
status "power ${i} W": new physicalgraph.zwave.Zwave().meterV3.meterReport(
|
||||
scaledMeterValue: i, precision: 3, meterType: 4, scale: 2, size: 4).incomingMessage()
|
||||
}
|
||||
for (int i = 0; i <= 100; i += 10) {
|
||||
status "energy ${i} kWh": new physicalgraph.zwave.Zwave().meterV3.meterReport(
|
||||
scaledMeterValue: i, precision: 3, meterType: 0, scale: 0, size: 4).incomingMessage()
|
||||
}
|
||||
|
||||
["FF", "00", "09", "0A", "21", "42", "63"].each { val ->
|
||||
reply "2001$val,delay 100,2602": "command: 2603, payload: $val"
|
||||
}
|
||||
}
|
||||
|
||||
// tile definitions
|
||||
|
||||
tiles(scale: 2) {
|
||||
multiAttributeTile(name:"switch", type: "lighting", width: 6, height: 4, canChangeIcon: true){
|
||||
tileAttribute ("device.switch", key: "PRIMARY_CONTROL") {
|
||||
attributeState "on", label:'${name}', action:"switch.off", icon:"st.switches.switch.on", backgroundColor:"#79b821", nextState:"turningOff"
|
||||
attributeState "off", label:'${name}', action:"switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff", nextState:"turningOn"
|
||||
attributeState "turningOn", label:'${name}', action:"switch.off", icon:"st.switches.switch.on", backgroundColor:"#79b821", nextState:"turningOff"
|
||||
attributeState "turningOff", label:'${name}', action:"switch.on", icon:"st.switches.switch.off", backgroundColor:"#ffffff", nextState:"turningOn"
|
||||
}
|
||||
tileAttribute ("device.level", key: "SLIDER_CONTROL") {
|
||||
attributeState "level", action:"switch level.setLevel"
|
||||
}
|
||||
}
|
||||
valueTile("power", "device.power", decoration: "flat", width: 2, height: 2) {
|
||||
state "default", label:'${currentValue} W'
|
||||
}
|
||||
valueTile("energy", "device.energy", decoration: "flat", width: 2, height: 2) {
|
||||
state "default", label:'${currentValue} kWh'
|
||||
}
|
||||
standardTile("reset", "device.energy", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
|
||||
state "default", label:'reset kWh', action:"reset"
|
||||
}
|
||||
standardTile("configureAfterSecure", "device.configure", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
|
||||
state "configure", label:'', action:"configureAfterSecure", icon:"st.secondary.configure"
|
||||
}
|
||||
standardTile("refresh", "device.power", inactiveLabel: false, decoration: "flat", width: 2, height: 2) {
|
||||
state "default", label:'', action:"refresh.refresh", icon:"st.secondary.refresh"
|
||||
}
|
||||
|
||||
main(["switch","power","energy"])
|
||||
details(["switch","power","energy","configureAfterSecure","refresh","reset"])
|
||||
}
|
||||
|
||||
preferences {
|
||||
def paragraph = "GROUP 0 - The Dimmer 2 behavior - Basic functionalities"
|
||||
input name: "param1", type: "number", range: "1..98", defaultValue: "1", required: true,
|
||||
title: paragraph + "\n\n" +
|
||||
"1. Minimum brightness level. " +
|
||||
"This parameter is set automatically during the calibration process. " +
|
||||
"The parameter can be changed manually after the calibration.\n" +
|
||||
"Available settings: 1-98 - percentage level of brightness.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param2", type: "number", range: "2..99", defaultValue: "99", required: true,
|
||||
title: "2. Maximum brightness level. " +
|
||||
"This parameter is set automatically during the calibration process. " +
|
||||
"The parameter can be changed manually after the calibration.\n" +
|
||||
"Available settings: 2-99 - percentage level of brightness.\n" +
|
||||
"Default value: 99."
|
||||
|
||||
input name: "param3", type: "number", range: "1..99", defaultValue: "1", required: true,
|
||||
title: "3. Incandescence level of dimmable compact fluorescent lamps. " +
|
||||
"Virtual value set as a percentage level between parameters MIN (1%) and MAX (99%). " +
|
||||
"The Dimmer 2 will set to this value after first switch on. " +
|
||||
"It is required for warming up and switching dimmable compact fluorescent lamps and certain types of light sources.\n" +
|
||||
"Available settings: 1-99 - percentage level of brightness.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param4", type: "number", range: "0..255", defaultValue: "0", required: true,
|
||||
title: "4. Incandescence time of dimmable compact fluorescent lamps. " +
|
||||
"This parameter determines the time required for switching compact fluorescent lamps and certain types of light sources. " +
|
||||
"Setting this parameter to 0 will disable the incandescence functionality.\n" +
|
||||
"Available settings: 0-255 (0-25.5s).\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param5", type: "number", range: "1..99", defaultValue: "1", required: true,
|
||||
title: "5. Automatic control - dimming step size. " +
|
||||
"This parameter defines the percentage value of dimming step during the automatic control.\n" +
|
||||
"Available settings: 1-99 - dimming step percentage value.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param6", type: "number", range: "0..255", defaultValue: "1", required: true,
|
||||
title: "6. Automatic control - time of a dimming step. " +
|
||||
"This parameter defines the time of single dimming step set in parameter 5 during the automatic control.\n" +
|
||||
"Available settings: 0-255 (0-2.55s, in 10ms steps).\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param7", type: "number", range: "1..99", defaultValue: "1", required: true,
|
||||
title: "7. Manual control - dimming step size. " +
|
||||
"This parameter defines the percentage value of dimming step during the manual control.\n" +
|
||||
"Available settings: 1-99 - dimming step percentage value.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param8", type: "number", range: "0..255", defaultValue: "5", required: true,
|
||||
title: "8. Manual control - time of a dimming step. " +
|
||||
"This parameter defines the time of single dimming step set in parameter 7 during the manual control.\n" +
|
||||
"Available settings: 0-255 (0-2.55s, in 10ms steps).\n" +
|
||||
"Default value: 5."
|
||||
|
||||
input name: "param9", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "9. State of the device after a power failure. " +
|
||||
"The Dimmer 2 will return to the last state before power failure.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = the Dimmer 2 does not save the state before a power failure, it returns to „off” position,\n" +
|
||||
"1 = the Dimmer 2 restores its state before power failure.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param10", type: "number", range: "0..32767", defaultValue: "0", required: true,
|
||||
title: "10. Timer functionality (auto - off). " +
|
||||
"This parameter allows to automatically switch off the device after specified time from switching on the light source. " +
|
||||
"It may be useful when the Dimmer 2 is installed in the stairway.\n" +
|
||||
"Available settings: 0 - Function disabled,\n1-32767 - time to turn off measured in seconds (1s-9.1h).\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param11", type: "enum", defaultValue: "255", required: true,
|
||||
options: ["0" : "0",
|
||||
"1" : "1",
|
||||
"2" : "2",
|
||||
"255" : "255"],
|
||||
title: "11. ALL ON/ALL OFF function. " +
|
||||
"Parameter allows for activation/deactivation of Z-Wave commands enabling/disabling all devices located in direct range of the main controller.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = All ON not active, All OFF not active,\n" +
|
||||
"1 = All ON not active, All OFF active,\n" +
|
||||
"2 = All ON active, All OFF not active,\n" +
|
||||
"255 = All ON active, All OFF active.\n" +
|
||||
"Default value: 255."
|
||||
|
||||
input name: "param13", type: "number", range: "0..2", defaultValue: "0", required: true,
|
||||
title: "13. Force auto-calibration. " +
|
||||
"Changing value of this parameter will force the calibration process. " +
|
||||
"During the calibration parameter is set to 1 or 2 and switched to 0 upon completion.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = readout,\n" +
|
||||
"1 = force auto-calibration of the load without FIBARO Bypass 2,\n" +
|
||||
"2 = force auto-calibration of the load with FIBARO Bypass 2.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param15", type: "number", range: "0..99", defaultValue: "30", required: true,
|
||||
title: "15. Burnt out bulb detection. " +
|
||||
"Function based on the sudden power variation of a specific value, interpreted as a LOAD ERROR.\n" +
|
||||
"Available settings:\n0 - function disabled,\n" +
|
||||
"1-99 - percentage value of power variation, compared to standard power consumption, measured during the calibration procedure (to be interpreted as load error/burnt out bulb).\n" +
|
||||
"Default value: 30."
|
||||
|
||||
input name: "param16", type: "number", range: "0..255", defaultValue: "5", required: true,
|
||||
title: "16. Time delay of a burnt out bulb (parameter 15) or overload (parameter 39) detection. " +
|
||||
"Time of delay (in seconds) for power variation detection, interpreted as a LOAD ERROR or OVERLOAD detection (too much power connected to the Dimmer 2).\n" +
|
||||
"Available settings:\n0 - detection of a burnt out bulb disabled,\n1-255 - delay time in seconds.\n" +
|
||||
"Default value: 5."
|
||||
|
||||
input name: "param19", type: "number", range: "0..99", defaultValue: "0", required: true,
|
||||
title: "19. Forced switch on brightness level. " +
|
||||
"If the parameter is active, switching on the Dimmer 2 (S1 single click) will always set this brightness level.\n" +
|
||||
"Available settings:\n0 - function disabled,\n1-99 - percentage level of brightness.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
paragraph = "GROUP 20 - Dimmer 2 operation - Switches"
|
||||
input name: "param20", type: "number", range: "0..2", defaultValue: "0", required: true,
|
||||
title: paragraph + "\n\n" +
|
||||
"20. Switch type. " +
|
||||
"Choose between momentary, toggle and roller blind switch.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = momentary switch,\n1 = toggle switch,\n2 = roller blind switch - two switches operate the Dimmer 2 (S1 to brighten, S2 to dim).\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param21", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "21. The value sent to associated devices on single click. " +
|
||||
"This parameter defines the value sent to devices associated with Dimmer 2 after its enabling.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = 0xFF value is sent, which will set associated devices to their last saved state,\n" +
|
||||
"1 = current Dimmer 2 state is sent, which will synchronize brightness level of associated devices (other dimmers for example).\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param22", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "22. Assign toggle switch status to the device status. " +
|
||||
"By default each change of toggle switch position results in action of Dimmer 2 (switch on/off) regardless the physical connection of contacts.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = device changes status on switch status change,\n1 = device status is synchronized with switch status.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param23", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "23. Double click option - set the brightness level to MAX.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = double click disabled,\n" +
|
||||
"1 = double click enabled.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param24", type: "enum", defaultValue: "0", required: true,
|
||||
options: ["0" : "0",
|
||||
"1" : "1",
|
||||
"2" : "2",
|
||||
"4" : "4",
|
||||
"8" : "8",
|
||||
"16" : "16"],
|
||||
title: "24. Command frames sent in 2nd and 3rd association groups (S1 associations). " +
|
||||
"Parameter determines, which actions will not result in sending frames to association groups.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = all actions send to association groups,\n" +
|
||||
"1 = do not send when switching ON (single click),\n" +
|
||||
"2 = do not send when switching OFF (single click),\n" +
|
||||
"4 = do not send when changing dimming level (holding and releasing),\n" +
|
||||
"8 = do not send on double click,\n" +
|
||||
"16 = send 0xFF value on double click.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param25", type: "enum", defaultValue: "0", required: true,
|
||||
options: ["0" : "0",
|
||||
"1" : "1",
|
||||
"2" : "2",
|
||||
"4" : "4",
|
||||
"8" : "8",
|
||||
"16" : "16"],
|
||||
title: "25. Command frames sent in 4th and 5th association groups (S2 associations). " +
|
||||
"Parameter determines, which actions will not result in sending frames to association groups.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = all actions send to association groups,\n" +
|
||||
"1 = do not send when switching ON (single click),\n" +
|
||||
"2 = do not send when switching OFF (single click),\n" +
|
||||
"4 = do not send when changing dimming level (holding and releasing),\n" +
|
||||
"8 = do not send on double click,\n" +
|
||||
"16 = send 0xFF value on double click.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param26", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "26. The function of 3-way switch. " +
|
||||
"Switch no. 2 controls the Dimmer 2 additionally (in 3-way switch mode). Function disabled for parameter 20 set to 2 (roller blind switch).\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = 3-way switch function for S2 disabled,\n" +
|
||||
"1 = 3-way switch function for S2 enabled.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param27", type: "enum", defaultValue: "15", required: true,
|
||||
options: ["0" : "0",
|
||||
"1" : "1",
|
||||
"2" : "2",
|
||||
"4" : "4",
|
||||
"8" : "8",
|
||||
"15" : "15"],
|
||||
title: "27. Associations in Z-Wave network security mode. " +
|
||||
"This parameter defines how commands are sent in speci ed association groups: as secure or non-secure. " +
|
||||
"Parameter is active only in Z-Wave network security mode. It does not apply to 1st lifeline group.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = all groups (II-V) sent as non-secure,\n" +
|
||||
"1 = 2nd group sent as secure,\n" +
|
||||
"2 = 3rd group sent as secure,\n" +
|
||||
"4 = 4th group sent as secure,\n" +
|
||||
"8 = 5th group sent as secure,\n" +
|
||||
"15 = all groups (II-V) sent as secure.\n" +
|
||||
"Default value: 15."
|
||||
|
||||
input name: "param28", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "28. Scene activation functionality.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = functionality deactivated,\n" +
|
||||
"1 = functionality activated.\n" +
|
||||
"Default value: 0.\n\n" +
|
||||
"SCENE ID depends on the switch type configurations.\n" +
|
||||
"Momentary switches:\n" +
|
||||
"SCENE ID: S1 input:\n\t16 : 1 x click\n\t14 : 2 x click\n\t-- : 3 x click\n\t12 : hold\n\t13 : release\n" +
|
||||
"SCENE ID: S2 input:\n\t26 : 1 x click\n\t24 : 2 x click\n\t25 : 3 x click\n\t22 : hold\n\t23 : release\n\n" +
|
||||
"Toggle switches:\n" +
|
||||
"SCENE ID: S1 input:\n\t10 : OFF to ON\n\t11 : ON to OFF\n\t14 : 2 x click\n\t-- : 3 x click\n" +
|
||||
"SCENE ID: S2 input:\n\t20 : OFF to ON\n\t21 : ON to OFF\n\t24 : 2 x click\n\t25 : 3 x click\n\n" +
|
||||
"Roller blinds switches:\n" +
|
||||
"SCENE ID: S1 input:\n\t10 : turn ON (1 x click)\n\t13 : release\n\t14 : 2 x click\n\t-- : 3 x click\n\t17 : brightening\n" +
|
||||
"SCENE ID: S2 input:\n\t11 : turn OFF (1 x click)\n\t13 : release\n\t14 : 2 x click\n\t15 : 3 x click\n\t18 : dimming"
|
||||
|
||||
input name: "param29", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "29. Switch functionality of S1 and S2. " +
|
||||
"This parameter allows for switching the role of keys connected to S1 and S2 without changes in connection.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = standard mode,\n" +
|
||||
"1 = S1 operates as S2, S2 operates as S1.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
paragraph = "GROUP 30 - Dimmer 2 operation - Advanced functionality"
|
||||
input name: "param30", type: "number", range: "0..2", defaultValue: "2", required: true,
|
||||
title: paragraph + "\n\n" +
|
||||
"30. Load control mode. " +
|
||||
"This parameter allows to set the desired load control mode. " +
|
||||
"The de- vice automatically adjusts correct control mode, but the installer may force its change using this parameter. " +
|
||||
"Forced auto-calibration will set this parameter’s value to 2.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = forced leading edge control,\n" +
|
||||
"1 = forced trailing edge control,\n" +
|
||||
"2 = control mode selected automatically (based on auto-calibration).\n" +
|
||||
"Default value: 2."
|
||||
|
||||
input name: "param32", type: "number", range: "0..2", defaultValue: "2", required: true,
|
||||
title: "32. On/Off mode. " +
|
||||
"This mode is necessary while connecting non-dimmable light sources. " +
|
||||
"Setting this parameter to 1 automatically ignores brightening/dimming time settings. " +
|
||||
"Forced auto-calibration will set this parameter’s value to 2.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = on/off mode disabled (dimming is possible),\n" +
|
||||
"1 = on/off mode enabled (dimming is not possible),\n" +
|
||||
"2 = mode selected automatically.\n" +
|
||||
"Default value: 2."
|
||||
|
||||
input name: "param34", type: "number", range: "0..2", defaultValue: "1", required: true,
|
||||
title: "34. Soft-Start functionality. " +
|
||||
"Time required to warm up the lament of halogen bulb.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = no soft-start,\n" +
|
||||
"1 = short soft-start (0.1s),\n" +
|
||||
"2 = long soft-start (0.5s).\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param35", type: "number", range: "0..4", defaultValue: "1", required: true,
|
||||
title: "35. Auto-calibration after power on. " +
|
||||
"This parameter determines the trigger of auto-calibration procedure, e.g. power on, load error, etc.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No auto-calibration of the load after power on,\n" +
|
||||
"1 = Auto-calibration performed after first power on,\n" +
|
||||
"2 = Auto-calibration performed after each power on,\n" +
|
||||
"3 = Auto-calibration performed after first power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb), if parameter 37 is set to 1 also after alarms: SURGE (Dimmer 2 output overvoltage) and OVERCURRENT (Dimmer 2 output overcurrent),\n" +
|
||||
"4 = Auto-calibration performed after each power on or after each LOAD ERROR alarm (no load, load failure, burnt out bulb), if parameter 37 is set to 1 also after alarms: SURGE (Dimmer 2 output overvoltage) and OVERCURRENT (Dimmer 2 output overcurrent).\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param37", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "37. Behaviour of the Dimmer 2 after OVERCURRENT or SURGE. " +
|
||||
"Occuring of errors related to surge or overcurrent results in turning off the output to prevent possible malfunction. " +
|
||||
"By default the device performs three attempts to turn on the load (useful in case of momentary, short failures of the power supply).\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = device permanently disabled until re-ena- bling by command or external switch,\n" +
|
||||
"1 = three attempts to turn on the load.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param39", type: "number", range: "0..350", defaultValue: "250", required: true,
|
||||
title: "39. Power limit - OVERLOAD. " +
|
||||
"Reaching the defined value will result in turning off the load. " +
|
||||
"Additional apparent power limit of 350VA is active by default.\n" +
|
||||
"Available settings:\n0 - functionality disabled,\n1-350 - 1-350W.\n" +
|
||||
"Default value: 250."
|
||||
|
||||
paragraph = "GROUP 40 - Dimmer 2 operation - Alarms"
|
||||
input name: "param40", type: "number", range: "0..3", defaultValue: "3", required: true,
|
||||
title: paragraph + "\n\n" +
|
||||
"40. Response to General Purpose Alarm.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No reaction,\n" +
|
||||
"1 = Turn on the load,\n" +
|
||||
"2 = Turn off the load,\n" +
|
||||
"3 = Load blinking.\n" +
|
||||
"Default value: 3."
|
||||
|
||||
input name: "param41", type: "number", range: "0..3", defaultValue: "2", required: true,
|
||||
title: "41. Response to Water Flooding Alarm.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No reaction,\n" +
|
||||
"1 = Turn on the load,\n" +
|
||||
"2 = Turn off the load,\n" +
|
||||
"3 = Load blinking.\n" +
|
||||
"Default value: 2."
|
||||
|
||||
input name: "param42", type: "number", range: "0..3", defaultValue: "3", required: true,
|
||||
title: "42. Response to Smoke, CO or CO2 Alarm.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No reaction,\n" +
|
||||
"1 = Turn on the load,\n" +
|
||||
"2 = Turn off the load,\n" +
|
||||
"3 = Load blinking.\n" +
|
||||
"Default value: 3."
|
||||
|
||||
input name: "param43", type: "number", range: "0..3", defaultValue: "1", required: true,
|
||||
title: "43. Response to Temperature Alarm.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No reaction,\n" +
|
||||
"1 = Turn on the load,\n" +
|
||||
"2 = Turn off the load,\n" +
|
||||
"3 = Load blinking.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param44", type: "number", range: "1..32767", defaultValue: "600", required: true,
|
||||
title: "44. Time of alarm state.\n" +
|
||||
"Available settings: 1-32767 (1-32767 seconds).\n" +
|
||||
"Default value: 600."
|
||||
|
||||
paragraph = "Alarm settings - reports"
|
||||
input name: "param45", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: paragraph + "\n\n" +
|
||||
"45. OVERLOAD alarm report (load power consumption too high).\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No reaction,\n" +
|
||||
"1 = Send an alarm frame.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param46", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "46. LOAD ERROR alarm report (no load, load failure, burnt out bulb).\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No reaction,\n" +
|
||||
"1 = Send an alarm frame.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param47", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "47. OVERCURRENT alarm report (short circuit, burnt out bulb causing overcurrent).\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No reaction,\n" +
|
||||
"1 = Send an alarm frame.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param48", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "48. SURGE alarm report (Dimmer 2 output overvoltage).\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No reaction,\n" +
|
||||
"1 = Send an alarm frame.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
input name: "param49", type: "number", range: "0..1", defaultValue: "1", required: true,
|
||||
title: "49. OVERHEAT (critical temperature) and VOLTAGE DROP (low voltage) alarm report.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = No reaction,\n" +
|
||||
"1 = Send an alarm frame.\n" +
|
||||
"Default value: 1."
|
||||
|
||||
paragraph = "GROUP 50 - Active power and energy reports"
|
||||
input name: "param50", type: "number", range: "0..100", defaultValue: "10", required: true,
|
||||
title: paragraph + "\n\n" +
|
||||
"50. Active power reports. " +
|
||||
"The parameter defines the power level change that will result in a new power report being sent. " +
|
||||
"The value is a percentage of the previous report.\n" +
|
||||
"Available settings:\n0 - power reports disabled,\n1-100 (1-100%) - power report threshold.\n" +
|
||||
"Default value: 10."
|
||||
|
||||
input name: "param52", type: "number", range: "0..32767", defaultValue: "3600", required: true,
|
||||
title: "52. Periodic active power and energy reports. " +
|
||||
"Parameter 52 defines a time period between consecutive reports. Timer is reset and counted from zero after each report.\n" +
|
||||
"Available settings:\n0 - periodic reports disabled,\n1-32767 (1-32767 seconds).\n" +
|
||||
"Default value: 3600."
|
||||
|
||||
input name: "param53", type: "number", range: "0..255", defaultValue: "10", required: true,
|
||||
title: "53. Energy reports. " +
|
||||
"Energy level change which will result in sending a new energy report.\n" +
|
||||
"Available settings:\n0 - energy reports disabled,\n1-255 (0.01-2.55 kWh) - report triggering threshold.\n" +
|
||||
"Default value: 10."
|
||||
|
||||
input name: "param54", type: "number", range: "0..1", defaultValue: "0", required: true,
|
||||
title: "54. Self-measurement. " +
|
||||
"The Dimmer 2 may include active power and energy consumed by itself in reports sent to the main controller.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = Self-measurement inactive,\n" +
|
||||
"1 = Self-measurement active.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param58", type: "number", range: "0..2", defaultValue: "0", required: true,
|
||||
title: "58. Method of calculating the active power. This parameter defines how to calculate active power. " +
|
||||
"It is useful in a case of 2-wire connection with light sources other than resistive.\n" +
|
||||
"Available settings:\n" +
|
||||
"0 = measurement based on the standard algorithm,\n" +
|
||||
"1 = approximation based on the calibration data,\n" +
|
||||
"2 = approximation based on the control angle.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "param59", type: "number", range: "0..500", defaultValue: "0", required: true,
|
||||
title: "59. Approximated power at the maximum brightness level. " +
|
||||
"This parameter determines the approximate value of the power that will be reported by the device at its maximum brightness level.\n" +
|
||||
"Available settings: 0-500 (0-500W) - power consumed by the load at the maximum brightness level.\n" +
|
||||
"Default value: 0."
|
||||
|
||||
input name: "paramAssociationGroup1", type: "bool", defaultValue: true, required: true,
|
||||
title: "The Dimmer 2 provides the association of five groups.\n\n" +
|
||||
"1st Association Group „Lifeline”,\n" +
|
||||
"Default value: true"
|
||||
|
||||
input name: "paramAssociationGroup2", type: "bool", defaultValue: true, required: true,
|
||||
title: "2nd Association Group „On/Off (S1)”,\n" +
|
||||
"Default value: true"
|
||||
|
||||
input name: "paramAssociationGroup3", type: "bool", defaultValue: false, required: true,
|
||||
title: "3rd Association Group „Dimmer (S1)”,\n" +
|
||||
"Default value: false"
|
||||
|
||||
input name: "paramAssociationGroup4", type: "bool", defaultValue: false, required: true,
|
||||
title: "4th Association Group „On/Off (S2)”,\n" +
|
||||
"Default value: false"
|
||||
|
||||
input name: "paramAssociationGroup5", type: "bool", defaultValue: false, required: true,
|
||||
title: "5th Association Group „Dimmer (S2)”.\n" +
|
||||
"Default value: false"
|
||||
}
|
||||
}
|
||||
|
||||
def parse(String description) {
|
||||
log.trace(description)
|
||||
log.debug("RAW command: $description")
|
||||
def result = null
|
||||
|
||||
if (description != "updated") {
|
||||
def cmd = zwave.parse(description.replace("98C1", "9881"), [0x20: 1, 0x26: 3, 0x32: 3, 0x25: 1, 0x98: 1, 0x70: 1, 0x85: 2, 0x9B: 1, 0x90: 1, 0x73: 1, 0x30: 1, 0x28: 1, 0x72: 1])
|
||||
if (cmd) {
|
||||
result = zwaveEvent(cmd)
|
||||
}
|
||||
}
|
||||
log.debug "Parsed '${description}' to ${result.inspect()}"
|
||||
return result
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.sceneactivationv1.SceneActivationSet cmd) {
|
||||
log.debug( "Scene ID: $cmd.sceneId")
|
||||
log.debug( "Dimming Duration: $cmd.dimmingDuration")
|
||||
|
||||
sendEvent(name: "scene", value: "$cmd.sceneId", data: [switchType: "$settings.param20"], descriptionText: "Scene id $cmd.sceneId was activated", isStateChange: true)
|
||||
log.debug( "Scene id $cmd.sceneId was activated" )
|
||||
}
|
||||
|
||||
// Devices that support the Security command class can send messages in an encrypted form;
|
||||
// they arrive wrapped in a SecurityMessageEncapsulation command and must be unencapsulated
|
||||
def zwaveEvent(physicalgraph.zwave.commands.securityv1.SecurityMessageEncapsulation cmd) {
|
||||
log.trace(cmd)
|
||||
def encapsulatedCommand = cmd.encapsulatedCommand([0x20: 1, 0x26: 3, 0x32: 3, 0x25: 1, 0x98: 1, 0x70: 1, 0x85: 2, 0x9B: 1, 0x90: 1, 0x73: 1, 0x30: 1, 0x28: 1, 0x72: 1]) // can specify command class versions here like in zwave.parse
|
||||
if (encapsulatedCommand) {
|
||||
return zwaveEvent(encapsulatedCommand)
|
||||
} else {
|
||||
log.warn "Unable to extract encapsulated cmd from $cmd"
|
||||
createEvent(descriptionText: cmd.toString())
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicReport cmd) {
|
||||
log.trace(cmd)
|
||||
dimmerEvents(cmd)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.basicv1.BasicSet cmd) {
|
||||
log.trace(cmd)
|
||||
//dimmerEvents(cmd)
|
||||
}
|
||||
def zwaveEvent(physicalgraph.zwave.commands.switchmultilevelv3.SwitchMultilevelReport cmd) {
|
||||
log.trace(cmd)
|
||||
dimmerEvents(cmd)
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.switchbinaryv1.SwitchBinaryReport cmd)
|
||||
{
|
||||
log.trace(cmd)
|
||||
dimmerEvents(cmd)
|
||||
}
|
||||
|
||||
|
||||
def dimmerEvents(physicalgraph.zwave.Command cmd) {
|
||||
log.trace(cmd)
|
||||
def result = []
|
||||
def value = (cmd.value ? "on" : "off")
|
||||
def switchEvent = createEvent(name: "switch", value: value, descriptionText: "$device.displayName was turned $value")
|
||||
result << switchEvent
|
||||
if (cmd.value) {
|
||||
result << createEvent(name: "level", value: cmd.value, unit: "%")
|
||||
}
|
||||
if (switchEvent.isStateChange) {
|
||||
result << response(["delay 3000", zwave.meterV2.meterGet(scale: 2).format()])
|
||||
}
|
||||
return result
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.commands.meterv3.MeterReport cmd) {
|
||||
log.trace(cmd)
|
||||
if (cmd.meterType == 1) {
|
||||
if (cmd.scale == 0) {
|
||||
return createEvent(name: "energy", value: cmd.scaledMeterValue, unit: "kWh")
|
||||
} else if (cmd.scale == 1) {
|
||||
return createEvent(name: "energy", value: cmd.scaledMeterValue, unit: "kVAh")
|
||||
} else if (cmd.scale == 2) {
|
||||
return createEvent(name: "power", value: Math.round(cmd.scaledMeterValue), unit: "W")
|
||||
} else {
|
||||
return createEvent(name: "electric", value: cmd.scaledMeterValue, unit: ["pulses", "V", "A", "R/Z", ""][cmd.scale - 3])
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
def zwaveEvent(physicalgraph.zwave.Command cmd) {
|
||||
log.trace(cmd)
|
||||
log.debug "No handler for $cmd"
|
||||
// Handles all Z-Wave commands we aren't interested in
|
||||
createEvent(descriptionText: cmd.toString(), isStateChange: false)
|
||||
}
|
||||
|
||||
|
||||
def on() {
|
||||
log.trace("on")
|
||||
secureSequence([
|
||||
zwave.basicV1.basicSet(value: 0xFF),
|
||||
zwave.switchMultilevelV1.switchMultilevelGet()
|
||||
])
|
||||
}
|
||||
|
||||
def off() {
|
||||
log.trace("off")
|
||||
secureSequence([
|
||||
zwave.basicV1.basicSet(value: 0x00),
|
||||
zwave.switchMultilevelV1.switchMultilevelGet()
|
||||
])
|
||||
}
|
||||
|
||||
def poll() {
|
||||
log.trace("poll")
|
||||
secureSequence([
|
||||
zwave.meterV2.meterGet(scale: 0),
|
||||
zwave.meterV2.meterGet(scale: 2)
|
||||
])
|
||||
}
|
||||
|
||||
def refresh() {
|
||||
log.trace("trace")
|
||||
secureSequence([
|
||||
zwave.meterV2.meterGet(scale: 0),
|
||||
zwave.meterV2.meterGet(scale: 2)
|
||||
])
|
||||
}
|
||||
|
||||
def reset() {
|
||||
log.trace("reset")
|
||||
return secureSequence([
|
||||
zwave.switchMultilevelV1.switchMultilevelGet(),
|
||||
zwave.meterV2.meterReset(),
|
||||
zwave.meterV2.meterGet(scale: 0),
|
||||
zwave.meterV2.meterGet(scale: 2)
|
||||
])
|
||||
}
|
||||
|
||||
def setLevel(level) {
|
||||
log.trace("setlevel")
|
||||
if(level > 99) level = 99
|
||||
secureSequence([
|
||||
zwave.basicV1.basicSet(value: level),
|
||||
zwave.switchMultilevelV1.switchMultilevelGet()
|
||||
], 5000)
|
||||
}
|
||||
|
||||
def configureAfterSecure() {
|
||||
log.debug "configureAfterSecure()"
|
||||
def cmds = secureSequence([
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 1, size: 1, scaledConfigurationValue: param1.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 2, size: 1, scaledConfigurationValue: param2.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 3, size: 1, scaledConfigurationValue: param3.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 4, size: 2, scaledConfigurationValue: param4.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 5, size: 1, scaledConfigurationValue: param5.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 6, size: 2, scaledConfigurationValue: param6.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 7, size: 1, scaledConfigurationValue: param7.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 8, size: 2, scaledConfigurationValue: param8.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 9, size: 1, scaledConfigurationValue: param9.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 10, size: 2, scaledConfigurationValue: param10.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 11, size: 2, scaledConfigurationValue: param11.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 13, size: 1, scaledConfigurationValue: param13.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 15, size: 1, scaledConfigurationValue: param15.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 16, size: 2, scaledConfigurationValue: param16.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 19, size: 1, scaledConfigurationValue: param19.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 20, size: 1, scaledConfigurationValue: param20.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 21, size: 1, scaledConfigurationValue: param21.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 22, size: 1, scaledConfigurationValue: param22.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 23, size: 1, scaledConfigurationValue: param23.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 24, size: 1, scaledConfigurationValue: param24.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 25, size: 1, scaledConfigurationValue: param25.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 26, size: 1, scaledConfigurationValue: param26.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 27, size: 1, scaledConfigurationValue: param27.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 28, size: 1, scaledConfigurationValue: param28.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 29, size: 1, scaledConfigurationValue: param29.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 30, size: 1, scaledConfigurationValue: param30.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 32, size: 1, scaledConfigurationValue: param32.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 34, size: 1, scaledConfigurationValue: param34.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 35, size: 1, scaledConfigurationValue: param35.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 37, size: 1, scaledConfigurationValue: param37.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 39, size: 2, scaledConfigurationValue: param39.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 40, size: 1, scaledConfigurationValue: param40.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 41, size: 1, scaledConfigurationValue: param41.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 42, size: 1, scaledConfigurationValue: param42.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 43, size: 1, scaledConfigurationValue: param43.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 44, size: 2, scaledConfigurationValue: param44.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 45, size: 1, scaledConfigurationValue: param45.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 46, size: 1, scaledConfigurationValue: param46.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 47, size: 1, scaledConfigurationValue: param47.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 48, size: 1, scaledConfigurationValue: param48.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 49, size: 1, scaledConfigurationValue: param49.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 50, size: 1, scaledConfigurationValue: param50.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 52, size: 2, scaledConfigurationValue: param52.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 53, size: 2, scaledConfigurationValue: param53.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 54, size: 1, scaledConfigurationValue: param54.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 58, size: 1, scaledConfigurationValue: param58.toInteger()),
|
||||
zwave.configurationV1.configurationSet(parameterNumber: 59, size: 2, scaledConfigurationValue: param59.toInteger())
|
||||
])
|
||||
|
||||
// Register for Group 1
|
||||
if(paramAssociationGroup1) {
|
||||
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:1, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
else {
|
||||
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:1, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
// Register for Group 2
|
||||
if(paramAssociationGroup2) {
|
||||
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:2, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
else {
|
||||
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:2, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
// Register for Group 3
|
||||
if(paramAssociationGroup3) {
|
||||
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:3, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
else {
|
||||
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:3, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
// Register for Group 4
|
||||
if(paramAssociationGroup4) {
|
||||
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:4, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
else {
|
||||
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:4, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
// Register for Group 5
|
||||
if(paramAssociationGroups5) {
|
||||
cmds << secure(zwave.associationV2.associationSet(groupingIdentifier:5, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
else {
|
||||
cmds << secure(zwave.associationV2.associationRemove(groupingIdentifier:5, nodeId: [zwaveHubNodeId]))
|
||||
}
|
||||
|
||||
cmds
|
||||
}
|
||||
|
||||
def configure() {
|
||||
// Wait until after the secure exchange for this
|
||||
log.debug "configure()"
|
||||
}
|
||||
|
||||
def updated() {
|
||||
log.debug "updated()"
|
||||
response(["delay 2000"] + configureAfterSecure() + refresh())
|
||||
}
|
||||
|
||||
private secure(physicalgraph.zwave.Command cmd) {
|
||||
log.trace(cmd)
|
||||
zwave.securityV1.securityMessageEncapsulation().encapsulate(cmd).format()
|
||||
}
|
||||
|
||||
private secureSequence(commands, delay=200) {
|
||||
log.debug "$commands"
|
||||
delayBetween(commands.collect{ secure(it) }, delay)
|
||||
}
|
||||
@@ -0,0 +1,88 @@
|
||||
/**
|
||||
* Copyright 2015 SmartThings
|
||||
*
|
||||
* Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except
|
||||
* in compliance with the License. You may obtain a copy of the License at:
|
||||
*
|
||||
* http://www.apache.org/licenses/LICENSE-2.0
|
||||
*
|
||||
* Unless required by applicable law or agreed to in writing, software distributed under the License is distributed
|
||||
* on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License
|
||||
* for the specific language governing permissions and limitations under the License.
|
||||
*/
|
||||
definition(
|
||||
name: "Fibaro Dimmer Scenes",
|
||||
namespace: "My Apps",
|
||||
author: "Elnar Hajiyev",
|
||||
description: "Smart app that allows to control switches with changes of Fibaro Dimmer Scenes.",
|
||||
category: "Convenience",
|
||||
iconUrl: "https://s3.amazonaws.com/smartapp-icons/Meta/light_outlet.png",
|
||||
iconX2Url: "https://s3.amazonaws.com/smartapp-icons/Meta/light_outlet@2x.png"
|
||||
)
|
||||
|
||||
preferences {
|
||||
section("Listen to scenes from this Fibaro Dimmer devices...") {
|
||||
input "fibaroDevicesSet", "capability.switch", title: "Fibaro Dimmers?", multiple: true, required: true
|
||||
}
|
||||
section("When any of these scenes are activated...") {
|
||||
input "scenesSet1", "enum", title: "Fibaro Dimmer scenes (set 1)?", multiple: true, required: false,
|
||||
options: ["10","11","12","13", "14", "15", "16", "17", "18", "20", "21", "22", "23", "24", "25", "26"]
|
||||
}
|
||||
section("Turn on all of these switches") {
|
||||
input "switchesSet1", "capability.switch", multiple: true, required: false
|
||||
}
|
||||
section("When any of these scenes are activated...") {
|
||||
input "scenesSet2", "enum", title: "Fibaro Dimmer scenes (set 2)?", multiple: true, required: false,
|
||||
options: ["10","11","12","13", "14", "15", "16", "17", "18", "20", "21", "22", "23", "24", "25", "26"]
|
||||
}
|
||||
section("Turn off all of these switches") {
|
||||
input "switchesSet2", "capability.switch", multiple: true, required: false
|
||||
}
|
||||
section("When any of these scenes are activated...") {
|
||||
input "scenesSet3", "enum", title: "Fibaro Dimmer scenes (set 3)?", multiple: true, required: false,
|
||||
options: ["10","11","12","13", "14", "15", "16", "17", "18", "20", "21", "22", "23", "24", "25", "26"]
|
||||
}
|
||||
section("Toggle all of these switches") {
|
||||
input "switchesSet3", "capability.switch", multiple: true, required: false
|
||||
}
|
||||
}
|
||||
|
||||
def installed()
|
||||
{
|
||||
subscribe(fibaroDevicesSet, "scene", sceneHandler, [filterEvents: false])
|
||||
}
|
||||
|
||||
def updated()
|
||||
{
|
||||
unsubscribe()
|
||||
subscribe(fibaroDevicesSet, "scene", sceneHandler, [filterEvents: false])
|
||||
}
|
||||
|
||||
def sceneHandler(evt) {
|
||||
log.debug evt.value
|
||||
log.debug evt.data
|
||||
|
||||
if(scenesSet1 && scenesSet1.contains(evt.value)) {
|
||||
switchesSet1.on()
|
||||
}
|
||||
else if(scenesSet2 && scenesSet2.contains(evt.value)) {
|
||||
switchesSet2.off()
|
||||
}
|
||||
else if(scenesSet3 && scenesSet3.contains(evt.value)) {
|
||||
toggle(switchesSet3)
|
||||
}
|
||||
}
|
||||
|
||||
def toggle(devices) {
|
||||
log.debug "toggle: $devices = ${devices*.currentValue('switch')}"
|
||||
|
||||
if (devices*.currentValue('switch').contains('off')) {
|
||||
devices.on()
|
||||
}
|
||||
else if (devices*.currentValue('switch').contains('on')) {
|
||||
devices.off()
|
||||
}
|
||||
else {
|
||||
devices.on()
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user